Files
librenms-librenms/tests/data/cmts.json
T
TheGreatDoc 8c610326e3 Added SNR Sensor to CMTS Arris (#8840)
DO NOT DELETE THIS TEXT

#### Please note

> Please read this information carefully. You can run `./scripts/pre-commit.php` to check your code before submitting.

- [X ] Have you followed our [code guidelines?](http://docs.librenms.org/Developing/Code-Guidelines/)

#### Testers

If you would like to test this pull request then please run: `./scripts/github-apply <pr_id>`, i.e `./scripts/github-apply 5926`
2018-06-23 21:57:59 +01:00

1326 lines
59 KiB
JSON

{
"os": {
"discovery": {
"devices": [
{
"sysName": "<private>",
"sysObjectID": ".1.3.6.1.4.1.4998.2.1",
"sysDescr": "CMTS_V08.02.00.97, <<HW_REV: 3.0; VENDOR: ARRIS; BOOTR: V00.01.00>>",
"sysContact": null,
"version": null,
"hardware": "",
"features": null,
"location": null,
"os": "cmts",
"type": "network",
"serial": null,
"icon": "arris.svg"
}
]
},
"poller": {
"devices": [
{
"sysName": "<private>",
"sysObjectID": ".1.3.6.1.4.1.4998.2.1",
"sysDescr": "CMTS_V08.02.00.97, <<HW_REV: 3.0; VENDOR: ARRIS; BOOTR: V00.01.00>>",
"sysContact": "<private>",
"version": "08.02.00.97",
"hardware": "C4",
"features": null,
"location": "<private>",
"os": "cmts",
"type": "network",
"serial": null,
"icon": "arris.svg"
}
]
}
},
"sensors": {
"discovery": {
"sensors": [
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.721433",
"sensor_index": "docsIfSigQSignalNoise.721433",
"sensor_type": "cmts",
"sensor_descr": "Channel NF Plasa - cable 10/- upstream 0.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "29.1",
"sensor_limit": "30.555",
"sensor_limit_warn": null,
"sensor_limit_low": "27.645",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.721441",
"sensor_index": "docsIfSigQSignalNoise.721441",
"sensor_type": "cmts",
"sensor_descr": "Channel NF Miguel H. - cable 10/- upstream 1.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "33.1",
"sensor_limit": "34.755",
"sensor_limit_warn": null,
"sensor_limit_low": "31.445",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.721449",
"sensor_index": "docsIfSigQSignalNoise.721449",
"sensor_type": "cmts",
"sensor_descr": "Channel NF Cuba - cable 10/- upstream 2.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "42",
"sensor_limit": "44.1",
"sensor_limit_warn": null,
"sensor_limit_low": "39.9",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.721457",
"sensor_index": "docsIfSigQSignalNoise.721457",
"sensor_type": "cmts",
"sensor_descr": "Channel NF Cano 1 - 1 - cable 10/- upstream 3.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "25.9",
"sensor_limit": "27.195",
"sensor_limit_warn": null,
"sensor_limit_low": "24.605",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.721465",
"sensor_index": "docsIfSigQSignalNoise.721465",
"sensor_type": "cmts",
"sensor_descr": "Channel NF Cano 1 - 2 - cable 10/- upstream 4.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "25.8",
"sensor_limit": "27.09",
"sensor_limit_warn": null,
"sensor_limit_low": "24.51",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.721473",
"sensor_index": "docsIfSigQSignalNoise.721473",
"sensor_type": "cmts",
"sensor_descr": "Channel NF Cano 2 - 1 - cable 10/- upstream 5.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "30.4",
"sensor_limit": "31.92",
"sensor_limit_warn": null,
"sensor_limit_low": "28.88",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.721481",
"sensor_index": "docsIfSigQSignalNoise.721481",
"sensor_type": "cmts",
"sensor_descr": "Channel NF Cano 2 - 2 - cable 10/- upstream 6.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "21.8",
"sensor_limit": "22.89",
"sensor_limit_warn": null,
"sensor_limit_low": "20.71",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.721489",
"sensor_index": "docsIfSigQSignalNoise.721489",
"sensor_type": "cmts",
"sensor_descr": "Channel Acequion - cable 10/- upstream 7.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "24.3",
"sensor_limit": "25.515",
"sensor_limit_warn": null,
"sensor_limit_low": "23.085",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.721497",
"sensor_index": "docsIfSigQSignalNoise.721497",
"sensor_type": "cmts",
"sensor_descr": "Channel Acequion 2 - cable 10/- upstream 8.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "27.4",
"sensor_limit": "28.77",
"sensor_limit_warn": null,
"sensor_limit_low": "26.03",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.721505",
"sensor_index": "docsIfSigQSignalNoise.721505",
"sensor_type": "cmts",
"sensor_descr": "Channel Acequion 3 - cable 10/- upstream 9.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "34",
"sensor_limit": "35.7",
"sensor_limit_warn": null,
"sensor_limit_low": "32.3",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.721513",
"sensor_index": "docsIfSigQSignalNoise.721513",
"sensor_type": "cmts",
"sensor_descr": "Channel NF TST, Reyes, Monjas - 4 - cable 10/- upstream 10.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "0",
"sensor_limit": "0",
"sensor_limit_warn": null,
"sensor_limit_low": "0",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.721521",
"sensor_index": "docsIfSigQSignalNoise.721521",
"sensor_type": "cmts",
"sensor_descr": "Channel NF TST, Reyes, Monjas - 5 - cable 10/- upstream 11.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "0",
"sensor_limit": "0",
"sensor_limit_warn": null,
"sensor_limit_low": "0",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.786969",
"sensor_index": "docsIfSigQSignalNoise.786969",
"sensor_type": "cmts",
"sensor_descr": "Channel Rojo, Dr., M.Rafa - 1 - cable 11/- upstream 0.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "30.4",
"sensor_limit": "31.92",
"sensor_limit_warn": null,
"sensor_limit_low": "28.88",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.786977",
"sensor_index": "docsIfSigQSignalNoise.786977",
"sensor_type": "cmts",
"sensor_descr": "Channel Rojo, Dr., M.Rafa - 2 - cable 11/- upstream 1.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "29.4",
"sensor_limit": "30.87",
"sensor_limit_warn": null,
"sensor_limit_low": "27.93",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.786985",
"sensor_index": "docsIfSigQSignalNoise.786985",
"sensor_type": "cmts",
"sensor_descr": "Channel Rojo, Dr., M.Rafa - 3 - cable 11/- upstream 2.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "28.2",
"sensor_limit": "29.61",
"sensor_limit_warn": null,
"sensor_limit_low": "26.79",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.786993",
"sensor_index": "docsIfSigQSignalNoise.786993",
"sensor_type": "cmts",
"sensor_descr": "Channel Rojo, Dr., M.Rafa - 4 - cable 11/- upstream 3.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "20.6",
"sensor_limit": "21.63",
"sensor_limit_warn": null,
"sensor_limit_low": "19.57",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.787001",
"sensor_index": "docsIfSigQSignalNoise.787001",
"sensor_type": "cmts",
"sensor_descr": "Channel Rojo, Dr., M.Rafa - 5 - cable 11/- upstream 4.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "26.8",
"sensor_limit": "28.14",
"sensor_limit_warn": null,
"sensor_limit_low": "25.46",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.787009",
"sensor_index": "docsIfSigQSignalNoise.787009",
"sensor_type": "cmts",
"sensor_descr": "Channel Rojo, Dr., M.Rafa - 6 - cable 11/- upstream 5.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "26.9",
"sensor_limit": "28.245",
"sensor_limit_warn": null,
"sensor_limit_low": "25.555",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.787017",
"sensor_index": "docsIfSigQSignalNoise.787017",
"sensor_type": "cmts",
"sensor_descr": "Channel Rojo, Dr., M.Rafa - 7 - cable 11/- upstream 6.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "26.6",
"sensor_limit": "27.93",
"sensor_limit_warn": null,
"sensor_limit_low": "25.27",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.787025",
"sensor_index": "docsIfSigQSignalNoise.787025",
"sensor_type": "cmts",
"sensor_descr": "Channel NF TST - 3 - cable 11/- upstream 7.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "27.1",
"sensor_limit": "28.455",
"sensor_limit_warn": null,
"sensor_limit_low": "25.745",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.787033",
"sensor_index": "docsIfSigQSignalNoise.787033",
"sensor_type": "cmts",
"sensor_descr": "Channel NF Reyes - 1 - cable 11/- upstream 8.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "28.8",
"sensor_limit": "30.24",
"sensor_limit_warn": null,
"sensor_limit_low": "27.36",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.787041",
"sensor_index": "docsIfSigQSignalNoise.787041",
"sensor_type": "cmts",
"sensor_descr": "Channel NF Reyes - 2 - cable 11/- upstream 9.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "28.5",
"sensor_limit": "29.925",
"sensor_limit_warn": null,
"sensor_limit_low": "27.075",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.787049",
"sensor_index": "docsIfSigQSignalNoise.787049",
"sensor_type": "cmts",
"sensor_descr": "Channel NF TST - 1 - cable 11/- upstream 10.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "26.4",
"sensor_limit": "27.72",
"sensor_limit_warn": null,
"sensor_limit_low": "25.08",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.787057",
"sensor_index": "docsIfSigQSignalNoise.787057",
"sensor_type": "cmts",
"sensor_descr": "Channel NF TST - 2 - cable 11/- upstream 11.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "27.7",
"sensor_limit": "29.085",
"sensor_limit_warn": null,
"sensor_limit_low": "26.315",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.787065",
"sensor_index": "docsIfSigQSignalNoise.787065",
"sensor_type": "cmts",
"sensor_descr": "Channel Las Canas, Tejera - 1 - cable 11/- upstream 12.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "31.8",
"sensor_limit": "33.39",
"sensor_limit_warn": null,
"sensor_limit_low": "30.21",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.787073",
"sensor_index": "docsIfSigQSignalNoise.787073",
"sensor_type": "cmts",
"sensor_descr": "Channel Las Canas, Tejera - 2 - cable 11/- upstream 13.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "32.3",
"sensor_limit": "33.915",
"sensor_limit_warn": null,
"sensor_limit_low": "30.685",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.787081",
"sensor_index": "docsIfSigQSignalNoise.787081",
"sensor_type": "cmts",
"sensor_descr": "Channel Las Canas, Tejera - 3 - cable 11/- upstream 14.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "32.2",
"sensor_limit": "33.81",
"sensor_limit_warn": null,
"sensor_limit_low": "30.59",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.787089",
"sensor_index": "docsIfSigQSignalNoise.787089",
"sensor_type": "cmts",
"sensor_descr": "Channel Las Canas, Tejera - 4 - cable 11/- upstream 15.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "32.6",
"sensor_limit": "34.23",
"sensor_limit_warn": null,
"sensor_limit_low": "30.97",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.787097",
"sensor_index": "docsIfSigQSignalNoise.787097",
"sensor_type": "cmts",
"sensor_descr": "Channel Las Canas, Tejera - 5 - cable 11/- upstream 16.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "34.8",
"sensor_limit": "36.54",
"sensor_limit_warn": null,
"sensor_limit_low": "33.06",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.787105",
"sensor_index": "docsIfSigQSignalNoise.787105",
"sensor_type": "cmts",
"sensor_descr": "Channel Las Canas, Tejera - 6 - cable 11/- upstream 17.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "36.8",
"sensor_limit": "38.64",
"sensor_limit_warn": null,
"sensor_limit_low": "34.96",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.787113",
"sensor_index": "docsIfSigQSignalNoise.787113",
"sensor_type": "cmts",
"sensor_descr": "Channel NF C.S.E. - cable 11/- upstream 18.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "37",
"sensor_limit": "38.85",
"sensor_limit_warn": null,
"sensor_limit_low": "35.15",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.787121",
"sensor_index": "docsIfSigQSignalNoise.787121",
"sensor_type": "cmts",
"sensor_descr": "Channel NF C.S.E. - cable 11/- upstream 19.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "35.9",
"sensor_limit": "37.695",
"sensor_limit_warn": null,
"sensor_limit_low": "34.105",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.787129",
"sensor_index": "docsIfSigQSignalNoise.787129",
"sensor_type": "cmts",
"sensor_descr": "Channel NF Cura - cable 11/- upstream 20.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "0",
"sensor_limit": "0",
"sensor_limit_warn": null,
"sensor_limit_low": "0",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.787137",
"sensor_index": "docsIfSigQSignalNoise.787137",
"sensor_type": "cmts",
"sensor_descr": "Channel NF Cura - cable 11/- upstream 21.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "0",
"sensor_limit": "0",
"sensor_limit_warn": null,
"sensor_limit_low": "0",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.787145",
"sensor_index": "docsIfSigQSignalNoise.787145",
"sensor_type": "cmts",
"sensor_descr": "Channel OOS - cable 11/- upstream 22.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "0",
"sensor_limit": "0",
"sensor_limit_warn": null,
"sensor_limit_low": "0",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.787153",
"sensor_index": "docsIfSigQSignalNoise.787153",
"sensor_type": "cmts",
"sensor_descr": "Channel OOS - cable 11/- upstream 23.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "0",
"sensor_limit": "0",
"sensor_limit_warn": null,
"sensor_limit_low": "0",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.852505",
"sensor_index": "docsIfSigQSignalNoise.852505",
"sensor_type": "cmts",
"sensor_descr": "Channel NF Mar Baltico - cable 12/- upstream 0.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "31.7",
"sensor_limit": "33.285",
"sensor_limit_warn": null,
"sensor_limit_low": "30.115",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.852513",
"sensor_index": "docsIfSigQSignalNoise.852513",
"sensor_type": "cmts",
"sensor_descr": "Channel NF 4 Vientos 1 - cable 12/- upstream 1.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "37.4",
"sensor_limit": "39.27",
"sensor_limit_warn": null,
"sensor_limit_low": "35.53",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.852521",
"sensor_index": "docsIfSigQSignalNoise.852521",
"sensor_type": "cmts",
"sensor_descr": "Channel NF 4 Vientos 2 - cable 12/- upstream 2.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "37.4",
"sensor_limit": "39.27",
"sensor_limit_warn": null,
"sensor_limit_low": "35.53",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.852529",
"sensor_index": "docsIfSigQSignalNoise.852529",
"sensor_type": "cmts",
"sensor_descr": "Channel NF NF Monjas 1 - cable 12/- upstream 3.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "33.9",
"sensor_limit": "35.595",
"sensor_limit_warn": null,
"sensor_limit_low": "32.205",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.852537",
"sensor_index": "docsIfSigQSignalNoise.852537",
"sensor_type": "cmts",
"sensor_descr": "Channel NF NF Monjas 2 - cable 12/- upstream 4.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "34.2",
"sensor_limit": "35.91",
"sensor_limit_warn": null,
"sensor_limit_low": "32.49",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.852545",
"sensor_index": "docsIfSigQSignalNoise.852545",
"sensor_type": "cmts",
"sensor_descr": "Channel NF Mar Baltico 2 - cable 12/- upstream 5.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "28.5",
"sensor_limit": "29.925",
"sensor_limit_warn": null,
"sensor_limit_low": "27.075",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.852553",
"sensor_index": "docsIfSigQSignalNoise.852553",
"sensor_type": "cmts",
"sensor_descr": "Channel NF Domti - cable 12/- upstream 6.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "28.1",
"sensor_limit": "29.505",
"sensor_limit_warn": null,
"sensor_limit_low": "26.695",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.852561",
"sensor_index": "docsIfSigQSignalNoise.852561",
"sensor_type": "cmts",
"sensor_descr": "Channel NF Aro - cable 12/- upstream 7.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "35.8",
"sensor_limit": "37.59",
"sensor_limit_warn": null,
"sensor_limit_low": "34.01",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.852569",
"sensor_index": "docsIfSigQSignalNoise.852569",
"sensor_type": "cmts",
"sensor_descr": "Channel NF Aro 2 - cable 12/- upstream 8.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "35.7",
"sensor_limit": "37.485",
"sensor_limit_warn": null,
"sensor_limit_low": "33.915",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.852577",
"sensor_index": "docsIfSigQSignalNoise.852577",
"sensor_type": "cmts",
"sensor_descr": "Channel NF Domti 2 - cable 12/- upstream 9.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "29.2",
"sensor_limit": "30.66",
"sensor_limit_warn": null,
"sensor_limit_low": "27.74",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.852585",
"sensor_index": "docsIfSigQSignalNoise.852585",
"sensor_type": "cmts",
"sensor_descr": "Channel NF Cura 1 - cable 12/- upstream 10.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "28.1",
"sensor_limit": "29.505",
"sensor_limit_warn": null,
"sensor_limit_low": "26.695",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "snr",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.2.1.10.127.1.1.4.1.5.852593",
"sensor_index": "docsIfSigQSignalNoise.852593",
"sensor_type": "cmts",
"sensor_descr": "Channel NF Cura 2 - cable 12/- upstream 11.0",
"sensor_divisor": "10",
"sensor_multiplier": "1",
"sensor_current": "28.3",
"sensor_limit": "29.715",
"sensor_limit_warn": null,
"sensor_limit_low": "26.885",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "temperature",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.4.1.4998.1.1.10.1.4.2.1.29.1.11",
"sensor_index": "1.11",
"sensor_type": "cmts",
"sensor_descr": "CAM (0D, 12U)",
"sensor_divisor": "1",
"sensor_multiplier": "1",
"sensor_current": "32",
"sensor_limit": "100",
"sensor_limit_warn": null,
"sensor_limit_low": "22",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "temperature",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.4.1.4998.1.1.10.1.4.2.1.29.1.12",
"sensor_index": "1.12",
"sensor_type": "cmts",
"sensor_descr": "CAM (0D, 24U)",
"sensor_divisor": "1",
"sensor_multiplier": "1",
"sensor_current": "33",
"sensor_limit": "100",
"sensor_limit_warn": null,
"sensor_limit_low": "23",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "temperature",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.4.1.4998.1.1.10.1.4.2.1.29.1.13",
"sensor_index": "1.13",
"sensor_type": "cmts",
"sensor_descr": "CAM (0D, 12U)",
"sensor_divisor": "1",
"sensor_multiplier": "1",
"sensor_current": "43",
"sensor_limit": "100",
"sensor_limit_warn": null,
"sensor_limit_low": "33",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "temperature",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.4.1.4998.1.1.10.1.4.2.1.29.1.15",
"sensor_index": "1.15",
"sensor_type": "cmts",
"sensor_descr": "CAM (16D, 0U)",
"sensor_divisor": "1",
"sensor_multiplier": "1",
"sensor_current": "34",
"sensor_limit": "90",
"sensor_limit_warn": null,
"sensor_limit_low": "24",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "temperature",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.4.1.4998.1.1.10.1.4.2.1.29.1.16",
"sensor_index": "1.16",
"sensor_type": "cmts",
"sensor_descr": "CAM (16D, 0U)",
"sensor_divisor": "1",
"sensor_multiplier": "1",
"sensor_current": "35",
"sensor_limit": "90",
"sensor_limit_warn": null,
"sensor_limit_low": "25",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "temperature",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.4.1.4998.1.1.10.1.4.2.1.29.1.18",
"sensor_index": "1.18",
"sensor_type": "cmts",
"sensor_descr": "RCM A",
"sensor_divisor": "1",
"sensor_multiplier": "1",
"sensor_current": "38",
"sensor_limit": "90",
"sensor_limit_warn": null,
"sensor_limit_low": "28",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": "0",
"sensor_class": "temperature",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.4.1.4998.1.1.10.1.4.2.1.29.1.20",
"sensor_index": "1.20",
"sensor_type": "cmts",
"sensor_descr": "SCM A",
"sensor_divisor": "1",
"sensor_multiplier": "1",
"sensor_current": "25",
"sensor_limit": "80",
"sensor_limit_warn": null,
"sensor_limit_low": "15",
"sensor_limit_low_warn": null,
"sensor_alert": "1",
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
}
],
"state_indexes": []
},
"poller": "matches discovery"
},
"bgp-peers": {
"discovery": {
"devices": [
{
"bgpLocalAs": null
}
],
"bgpPeers": [],
"bgpPeers_cbgp": []
},
"poller": "matches discovery"
}
}