Files
librenms-librenms/mibs/telco-systems/binox/PRVT-STORM-CTL-MIB
Tony Murray 11147d3bbf Major Processors rewrite (#8066)
* Extract DiscoveryItem and move some things to better places.
Extract model class
Fix up model construction.  I have problem with construction...
Makeshift model working.  Switch constructor to factory.  discover() and create()
Support legacy discovery.
Remove uneeded custom pollers
Remove netonix custom detection as we try ucd on all os now.
Add a few yaml procs.  Fix a couple things.
More processor discovery conversions
Move Calix e7 to standard hrProcessorLoad, but it doesn't fully implement the HR-MIB, move things around to make it work.
Add a few yaml procs.  Fix a couple things. Correct some stupid mib stuff.
Move more, drop php 5.3
Add netscaler which uses string indexes.  Port fiberhome to yaml and use skip_values
More conversions.  BroadcomProcessorUsage Trait
Serveriron and Ironware share some mibs.  Create a common abstract os for them.
Add yaml support for mib specification in each data entry
Make legacy discover_processor() set 0 for hrDeviceIndex

Untangle Dell switch OS processors

Use use shared OS for groups if they don't have a specific group.
fix silly mib mistake

Make index optional

Move HR and UCD to Traits and out of Processor.

* forgot to update the fortiswitch index

* Make sgos and avaya-ers match the old index.

* fix comware test data

* fix merge errors

* fix dsm and remove pointless empty modules

* file not found exception is in the wrong place.

* Updated processor development docs
2018-02-05 07:39:13 -06:00

169 lines
5.7 KiB
Plaintext

-- *********************************************************************
-- **
-- ** BATM Advanced Communications.
-- **
-- *********************************************************************
-- ** Filename: PRVT-STORM-CTL-MIB.mib
-- ** Project: T-Metro Switches.
-- ** Purpose: Private MIB
-- *********************************************************************
-- (c) Copyright, 2009, BATM Advanced Communications. All rights reserved.
-- WARNING:
--
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
--
-- This file is the property of BATM Advanced Communications and contains
-- proprietary and confidential information. This file is made
-- available to authorized BATM customers on the express
-- condition that neither it, nor any of the information contained
-- therein, shall be disclosed to third parties or be used for any
-- purpose other than to replace, modify or upgrade firmware and/or
-- software components of BATM manufactured equipment within the
-- authorized customer's network, and that such transfer be
-- completed in accordance with the instructions provided by
-- BATM. Any other use is strictly prohibited.
--
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
--
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE.
--
-- ----------------------------------------------------------------------------
PRVT-STORM-CTL-MIB DEFINITIONS ::= BEGIN
IMPORTS
ifIndex
FROM IF-MIB
switch
FROM PRVT-SWITCH-MIB
MODULE-IDENTITY, OBJECT-TYPE, Unsigned32
FROM SNMPv2-SMI
RowStatus, TEXTUAL-CONVENTION, TruthValue
FROM SNMPv2-TC;
prvtStormCtlMIB MODULE-IDENTITY
LAST-UPDATED "201006210000Z"
ORGANIZATION
"BATM Advanced Communication"
CONTACT-INFO
"BATM/Telco Systems Support team
Email:
For North America: techsupport@telco.com
For North Europe: support@batm.de, info@batm.de
For the rest of the world: techsupport@telco.com"
DESCRIPTION
"The MIB module for managing storm control."
REVISION "201006210000Z"
DESCRIPTION
"Initial version."
::= { switch 171 }
RateThresholdType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"A rate threshold in packets per seconds."
SYNTAX Unsigned32
prvtStormCtlMIBObjects OBJECT IDENTIFIER
::= { prvtStormCtlMIB 1 }
prvtStrmCtlPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtStrmCtlPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of interfaces that have storm control functionality configured."
::= { prvtStormCtlMIBObjects 1 }
prvtStrmCtlPortEntry OBJECT-TYPE
SYNTAX PrvtStrmCtlPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in prvtStrmCtlPortTable."
INDEX { ifIndex }
::= { prvtStrmCtlPortTable 1 }
PrvtStrmCtlPortEntry ::= SEQUENCE {
prvtStrmCtlPortRowStatus RowStatus,
prvtStrmCtlPortShutdown TruthValue
}
prvtStrmCtlPortRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The RowStatus for this port."
::= { prvtStrmCtlPortEntry 1 }
prvtStrmCtlPortShutdown OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Set to 'false' to enable storm control functionality on this port."
::= { prvtStrmCtlPortEntry 3 }
prvtStrmCtlPortTrafficTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtStrmCtlPortTrafficEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of traffic-type specific configuration for each interface.
Currently, only one traffic type is supported per interface."
::= { prvtStormCtlMIBObjects 3 }
prvtStrmCtlPortTrafficEntry OBJECT-TYPE
SYNTAX PrvtStrmCtlPortTrafficEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in prvtStrmCtlPortTrafficTable."
INDEX { ifIndex, prvtStrmCtlPortTrafficType }
::= { prvtStrmCtlPortTrafficTable 1 }
PrvtStrmCtlPortTrafficEntry ::= SEQUENCE {
prvtStrmCtlPortTrafficType INTEGER,
prvtStrmCtlPortTrafficRowStatus RowStatus,
prvtStrmCtlPortTrafficThreshold RateThresholdType
}
prvtStrmCtlPortTrafficType OBJECT-TYPE
SYNTAX INTEGER { all(0), unknown(1), multicast(2), broadcast(4) }
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The type of traffic to which this row applies "
::= { prvtStrmCtlPortTrafficEntry 1 }
prvtStrmCtlPortTrafficRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The RowStatus for this traffic type."
::= { prvtStrmCtlPortTrafficEntry 2 }
prvtStrmCtlPortTrafficThreshold OBJECT-TYPE
SYNTAX RateThresholdType
UNITS "packets-per-second"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The threshold at which, when exceeded, traffic will undergo
storm control action for this port and traffic type."
::= { prvtStrmCtlPortTrafficEntry 3 }