mirror of
https://github.com/librenms/librenms.git
synced 2024-10-07 16:52:45 +00:00
* mempools to modern module quick hacky hrstorage port * port ucd-snmp-mib to Mempools * Populate DB for ucd Prep for yaml * initial yaml attempt * more complex conversions fixes to YamlDiscovery, make leading $ optional and allow mib::oid format * walk full tables and skip values normalize percentages above 100 * handle precent only ones (specify total as 100) * Move default polling out of YamlMempoolsDiscovery * fixes * Update test data hrstorage should be correct. * perc_warn for hrstorage * Host Resources, record buffer, cached, and shared * Host Resources is always better, don't do both HR and UCD * fix unix, include warning levels * variable size * consolidate skip_values * define mempools schema * number instead of integer * more schema refactor * one more skip_values reference * throw error for invalid oid translation aos6 * a* and Cisco * updated test data * update almost all hrstorage data files * b* * c* with test data use standard cache for hrStorage * use cache for storage module too * hand bsnmp properly * bdcom * exclude total oid from yaml so it is not polled May add a way to ignore this behavior and poll it, but I don't know if that is needed. * automatically handle percent only values * ciscowlc * only poll used or free if we have used, free, and total. * fix skipping * the dlinkoning fix find value when value "name" is numeric * support numeric oids * dnos/ftos attempt * I guess we can't filter on total > 0 * edgecos * e* * f WIP * f* * gwd (aka g*) * h* + procurve * i* * j* * m* * support 0% used memory (however unlikely) * n* * CISCO-PROCESS-MIB memory, share cache with processors module * ignore mempools with invalid total * p* * quanta * r* fix raisecom mibs terribly broken * s-z * style fixes * Move VRP back to PHP and make it actually work * fix zynos * update schema * Update Cisco processor data for description bug fixes * fix comware processors * comware mempools with memory size default precision to 1 * sophos-xg updated data * hrstorage use ram size for buffers, cache, and shared * Show memory available instead of free in device overview * UCD, use same rrd format, store available instead of free in the db. * Calculate availability for HOST-RESOURCES-MIB * Convert UCD to standard polling * rename old rrd files * initial graph work * graph WIP * Graph looking decent * Graph looking decent for hr * remove old ucd_graph code * handle availability mempool more graph cleanup * color adjustments * remove accidental free calculation * Update test data and fix corner cases * fis pfsense * update schema * add default value for mempool_class * fix whitespace * update schema * update schema correctly * one more time * fortigate_1500d-sensors missing oids * Update docs. * fix indent * add implements MempoolsDiscovery explicitly to OS * remove ucd_memory graph references remove unused device_memory graph * remove unused functions * set devices with mempools to rediscover to prevent/minimize gaps * use a subquery * add overview graph * port health mempools table * Update device mempool * only show overview if multiple * Don't override user set warn percentages in discovery * fix missed usage * fix style * Safety check to not rename rrd files incorrectly if migration has not been run. * Fix overview percent bar and represent available and used on the bar * missed an item to convert to mempool_class * percent on the wrong side
604 lines
25 KiB
JSON
604 lines
25 KiB
JSON
{
|
|
"os": {
|
|
"discovery": {
|
|
"devices": [
|
|
{
|
|
"sysName": "<private>",
|
|
"sysObjectID": ".1.3.6.1.4.1.8886.18.4.10",
|
|
"sysDescr": "ROAP Version ISCOM5508-EPSC_ROAP_2.61.3(a)_20161019.(Compiled Oct 19 2016, 19:12:24)",
|
|
"sysContact": null,
|
|
"version": "8.2.29_20180611",
|
|
"hardware": "RAX711-C-DC/D-02 version A.02",
|
|
"features": null,
|
|
"os": "raisecom",
|
|
"type": "network",
|
|
"serial": "123002030702S18B08S0001G",
|
|
"icon": "raisecom.png",
|
|
"location": "<private>"
|
|
}
|
|
]
|
|
},
|
|
"poller": {
|
|
"devices": [
|
|
{
|
|
"sysName": "<private>",
|
|
"sysObjectID": ".1.3.6.1.4.1.8886.18.4.10",
|
|
"sysDescr": "ROAP Version ISCOM5508-EPSC_ROAP_2.61.3(a)_20161019.(Compiled Oct 19 2016, 19:12:24)",
|
|
"sysContact": "<private>",
|
|
"version": "8.2.29_20180611",
|
|
"hardware": "RAX711-C-DC/D-02 version A.02",
|
|
"features": null,
|
|
"os": "raisecom",
|
|
"type": "network",
|
|
"serial": "123002030702S18B08S0001G",
|
|
"icon": "raisecom.png",
|
|
"location": "<private>"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
"processors": {
|
|
"discovery": {
|
|
"processors": [
|
|
{
|
|
"entPhysicalIndex": 0,
|
|
"hrDeviceIndex": 0,
|
|
"processor_oid": ".1.3.6.1.4.1.8886.1.1.1.3.1.2.1.2.5",
|
|
"processor_index": "3",
|
|
"processor_type": "raisecom",
|
|
"processor_usage": 3,
|
|
"processor_descr": "Processor",
|
|
"processor_precision": 1,
|
|
"processor_perc_warn": 75
|
|
}
|
|
]
|
|
},
|
|
"poller": {
|
|
"processors": [
|
|
{
|
|
"entPhysicalIndex": 0,
|
|
"hrDeviceIndex": 0,
|
|
"processor_oid": ".1.3.6.1.4.1.8886.1.1.1.3.1.2.1.2.5",
|
|
"processor_index": "3",
|
|
"processor_type": "raisecom",
|
|
"processor_usage": 4,
|
|
"processor_descr": "Processor",
|
|
"processor_precision": 1,
|
|
"processor_perc_warn": 75
|
|
}
|
|
]
|
|
}
|
|
},
|
|
"sensors": {
|
|
"discovery": {
|
|
"sensors": [
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "fanspeed",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.8886.1.1.5.2.2.1.2.1",
|
|
"sensor_index": "1",
|
|
"sensor_type": "raisecom",
|
|
"sensor_descr": "Fan 1 Speed",
|
|
"group": null,
|
|
"sensor_divisor": 1,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": 7440,
|
|
"sensor_limit": 10000,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": 0,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"state_name": null
|
|
},
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "fanspeed",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.8886.1.1.5.2.2.1.2.2",
|
|
"sensor_index": "2",
|
|
"sensor_type": "raisecom",
|
|
"sensor_descr": "Fan 2 Speed",
|
|
"group": null,
|
|
"sensor_divisor": 1,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": 7620,
|
|
"sensor_limit": 10000,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": 0,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"state_name": null
|
|
},
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "fanspeed",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.8886.1.1.5.2.2.1.2.3",
|
|
"sensor_index": "3",
|
|
"sensor_type": "raisecom",
|
|
"sensor_descr": "Fan 3 Speed",
|
|
"group": null,
|
|
"sensor_divisor": 1,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": 7800,
|
|
"sensor_limit": 10000,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": 0,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"state_name": null
|
|
},
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "fanspeed",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.8886.1.1.5.2.2.1.2.4",
|
|
"sensor_index": "4",
|
|
"sensor_type": "raisecom",
|
|
"sensor_descr": "Fan 4 Speed",
|
|
"group": null,
|
|
"sensor_divisor": 1,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": 7920,
|
|
"sensor_limit": 10000,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": 0,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"state_name": null
|
|
},
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "state",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.8886.1.2.1.3.0",
|
|
"sensor_index": "0",
|
|
"sensor_type": "raisecomConfigLoadState",
|
|
"sensor_descr": "Config 0 Load State",
|
|
"group": null,
|
|
"sensor_divisor": 1,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": 3,
|
|
"sensor_limit": null,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": null,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"state_name": "raisecomConfigLoadState"
|
|
},
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "state",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.8886.1.1.5.2.2.1.3.1",
|
|
"sensor_index": "1",
|
|
"sensor_type": "raisecomFanMonitorStateTable",
|
|
"sensor_descr": "Fan 1 State",
|
|
"group": null,
|
|
"sensor_divisor": 1,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": 1,
|
|
"sensor_limit": null,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": null,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"state_name": "raisecomFanMonitorStateTable"
|
|
},
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "state",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.8886.1.1.5.2.2.1.3.2",
|
|
"sensor_index": "2",
|
|
"sensor_type": "raisecomFanMonitorStateTable",
|
|
"sensor_descr": "Fan 2 State",
|
|
"group": null,
|
|
"sensor_divisor": 1,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": 1,
|
|
"sensor_limit": null,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": null,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"state_name": "raisecomFanMonitorStateTable"
|
|
},
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "state",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.8886.1.1.5.2.2.1.3.3",
|
|
"sensor_index": "3",
|
|
"sensor_type": "raisecomFanMonitorStateTable",
|
|
"sensor_descr": "Fan 3 State",
|
|
"group": null,
|
|
"sensor_divisor": 1,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": 1,
|
|
"sensor_limit": null,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": null,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"state_name": "raisecomFanMonitorStateTable"
|
|
},
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "state",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.8886.1.1.5.2.2.1.3.4",
|
|
"sensor_index": "4",
|
|
"sensor_type": "raisecomFanMonitorStateTable",
|
|
"sensor_descr": "Fan 4 State",
|
|
"group": null,
|
|
"sensor_divisor": 1,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": 1,
|
|
"sensor_limit": null,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": null,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"state_name": "raisecomFanMonitorStateTable"
|
|
},
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "state",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.8886.1.24.2.1.1.6.1",
|
|
"sensor_index": "1",
|
|
"sensor_type": "raisecomPowerMonitorStateTable",
|
|
"sensor_descr": "Power Supply 1 State",
|
|
"group": null,
|
|
"sensor_divisor": 1,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": 2,
|
|
"sensor_limit": null,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": null,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"state_name": "raisecomPowerMonitorStateTable"
|
|
},
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "state",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.8886.1.24.2.1.1.6.2",
|
|
"sensor_index": "2",
|
|
"sensor_type": "raisecomPowerMonitorStateTable",
|
|
"sensor_descr": "Power Supply 2 State",
|
|
"group": null,
|
|
"sensor_divisor": 1,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": 2,
|
|
"sensor_limit": null,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": null,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"state_name": "raisecomPowerMonitorStateTable"
|
|
},
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "temperature",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.8886.1.1.4.2.1.0",
|
|
"sensor_index": "0",
|
|
"sensor_type": "raisecomTemperatureValue",
|
|
"sensor_descr": "System Temperature",
|
|
"group": null,
|
|
"sensor_divisor": 1,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": 33,
|
|
"sensor_limit": 53,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": 23,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"state_name": null
|
|
},
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "voltage",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.8886.1.1.4.3.1.1.3.1",
|
|
"sensor_index": "1",
|
|
"sensor_type": "raisecom",
|
|
"sensor_descr": "Voltage 1 (mV)",
|
|
"group": null,
|
|
"sensor_divisor": 1000,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": 3.266,
|
|
"sensor_limit": 3.7559,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": 2.7761,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"state_name": null
|
|
},
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "voltage",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.8886.1.1.4.3.1.1.3.2",
|
|
"sensor_index": "2",
|
|
"sensor_type": "raisecom",
|
|
"sensor_descr": "Voltage 2 (mV)",
|
|
"group": null,
|
|
"sensor_divisor": 1000,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": 0.998,
|
|
"sensor_limit": 1.1477,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": 0.8483,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"state_name": null
|
|
},
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "voltage",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.8886.1.1.4.3.1.1.3.3",
|
|
"sensor_index": "3",
|
|
"sensor_type": "raisecom",
|
|
"sensor_descr": "Voltage 3 (mV)",
|
|
"group": null,
|
|
"sensor_divisor": 1000,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": 0.984,
|
|
"sensor_limit": 1.1316,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": 0.8364,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"state_name": null
|
|
},
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "voltage",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.8886.1.1.4.3.1.1.3.4",
|
|
"sensor_index": "4",
|
|
"sensor_type": "raisecom",
|
|
"sensor_descr": "Voltage 4 (mV)",
|
|
"group": null,
|
|
"sensor_divisor": 1000,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": 1.107,
|
|
"sensor_limit": 1.27305,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": 0.94095,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"state_name": null
|
|
},
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "voltage",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.8886.1.1.4.3.1.1.3.5",
|
|
"sensor_index": "5",
|
|
"sensor_type": "raisecom",
|
|
"sensor_descr": "Voltage 5 (mV)",
|
|
"group": null,
|
|
"sensor_divisor": 1000,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": 1.51,
|
|
"sensor_limit": 1.7365,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": 1.2835,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"state_name": null
|
|
},
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "voltage",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.8886.1.1.4.3.1.1.3.6",
|
|
"sensor_index": "6",
|
|
"sensor_type": "raisecom",
|
|
"sensor_descr": "Voltage 6 (mV)",
|
|
"group": null,
|
|
"sensor_divisor": 1000,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": 1.75,
|
|
"sensor_limit": 2.0125,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": 1.4875,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"state_name": null
|
|
}
|
|
],
|
|
"state_indexes": [
|
|
{
|
|
"state_name": "raisecomConfigLoadState",
|
|
"state_descr": "ready",
|
|
"state_draw_graph": 0,
|
|
"state_value": 1,
|
|
"state_generic_value": 1
|
|
},
|
|
{
|
|
"state_name": "raisecomConfigLoadState",
|
|
"state_descr": "running",
|
|
"state_draw_graph": 0,
|
|
"state_value": 2,
|
|
"state_generic_value": 1
|
|
},
|
|
{
|
|
"state_name": "raisecomConfigLoadState",
|
|
"state_descr": "successful",
|
|
"state_draw_graph": 0,
|
|
"state_value": 3,
|
|
"state_generic_value": 0
|
|
},
|
|
{
|
|
"state_name": "raisecomConfigLoadState",
|
|
"state_descr": "failed",
|
|
"state_draw_graph": 0,
|
|
"state_value": 4,
|
|
"state_generic_value": 2
|
|
},
|
|
{
|
|
"state_name": "raisecomFanMonitorStateTable",
|
|
"state_descr": "normal",
|
|
"state_draw_graph": 0,
|
|
"state_value": 1,
|
|
"state_generic_value": 0
|
|
},
|
|
{
|
|
"state_name": "raisecomFanMonitorStateTable",
|
|
"state_descr": "abnormal",
|
|
"state_draw_graph": 0,
|
|
"state_value": 2,
|
|
"state_generic_value": 2
|
|
},
|
|
{
|
|
"state_name": "raisecomPowerMonitorStateTable",
|
|
"state_descr": "offline",
|
|
"state_draw_graph": 0,
|
|
"state_value": 1,
|
|
"state_generic_value": 2
|
|
},
|
|
{
|
|
"state_name": "raisecomPowerMonitorStateTable",
|
|
"state_descr": "online",
|
|
"state_draw_graph": 0,
|
|
"state_value": 2,
|
|
"state_generic_value": 0
|
|
},
|
|
{
|
|
"state_name": "raisecomPowerMonitorStateTable",
|
|
"state_descr": "power-on",
|
|
"state_draw_graph": 0,
|
|
"state_value": 3,
|
|
"state_generic_value": 0
|
|
}
|
|
]
|
|
},
|
|
"poller": "matches discovery"
|
|
},
|
|
"mempools": {
|
|
"discovery": {
|
|
"mempools": [
|
|
{
|
|
"mempool_index": "0",
|
|
"entPhysicalIndex": null,
|
|
"mempool_type": "raisecom",
|
|
"mempool_class": "system",
|
|
"mempool_precision": 1,
|
|
"mempool_descr": "Memory",
|
|
"mempool_perc": 83,
|
|
"mempool_perc_oid": null,
|
|
"mempool_used": 666763263,
|
|
"mempool_used_oid": null,
|
|
"mempool_free": 138543105,
|
|
"mempool_free_oid": ".1.3.6.1.4.1.8886.1.1.3.2.2.0",
|
|
"mempool_total": 805306368,
|
|
"mempool_total_oid": null,
|
|
"mempool_largestfree": null,
|
|
"mempool_lowestfree": null,
|
|
"mempool_deleted": 0,
|
|
"mempool_perc_warn": 90
|
|
}
|
|
]
|
|
},
|
|
"poller": "matches discovery"
|
|
}
|
|
}
|