mirror of
				https://github.com/librenms/librenms.git
				synced 2024-10-07 16:52:45 +00:00 
			
		
		
		
	git-svn-id: http://www.observium.org/svn/observer/trunk@1645 61d68cd4-352d-0410-923a-c4978735b2b8
		
			
				
	
	
		
			6262 lines
		
	
	
		
			197 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
			
		
		
	
	
			6262 lines
		
	
	
		
			197 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
OPT-IF-MIB DEFINITIONS ::= BEGIN
 | 
						|
 | 
						|
IMPORTS
 | 
						|
    MODULE-IDENTITY, OBJECT-TYPE, Gauge32, Integer32,
 | 
						|
      Unsigned32, transmission
 | 
						|
          FROM SNMPv2-SMI
 | 
						|
    TEXTUAL-CONVENTION, RowPointer, RowStatus, TruthValue
 | 
						|
          FROM SNMPv2-TC
 | 
						|
    SnmpAdminString
 | 
						|
          FROM SNMP-FRAMEWORK-MIB
 | 
						|
    MODULE-COMPLIANCE, OBJECT-GROUP
 | 
						|
          FROM SNMPv2-CONF
 | 
						|
    ifIndex
 | 
						|
          FROM IF-MIB;
 | 
						|
 | 
						|
--  This is the MIB module for the OTN Interface objects.
 | 
						|
 | 
						|
optIfMibModule MODULE-IDENTITY
 | 
						|
    LAST-UPDATED "200308130000Z"
 | 
						|
    ORGANIZATION "IETF AToM MIB Working Group"
 | 
						|
    CONTACT-INFO
 | 
						|
       "WG charter:
 | 
						|
          http://www.ietf.org/html.charters/atommib-charter.html
 | 
						|
 | 
						|
        Mailing Lists:
 | 
						|
           General Discussion: atommib@research.telcordia.com
 | 
						|
           To Subscribe: atommib-request@research.telcordia.com
 | 
						|
        Editor: Hing-Kam Lam
 | 
						|
        Postal: Lucent Technologies, Room 4C-616
 | 
						|
                101 Crawfords Corner Road
 | 
						|
                Holmdel, NJ 07733
 | 
						|
           Tel: +1 732 949 8338
 | 
						|
         Email: hklam@lucent.com"
 | 
						|
    DESCRIPTION
 | 
						|
       "The MIB module to describe pre-OTN and OTN interfaces.
 | 
						|
 | 
						|
        Copyright (C) The Internet Society (2003).  This version
 | 
						|
        of this MIB module is part of RFC 3591;  see the RFC
 | 
						|
        itself for full legal notices."
 | 
						|
    REVISION  "200308130000Z"
 | 
						|
    DESCRIPTION
 | 
						|
       "Initial version, published as RFC 3591."
 | 
						|
    ::={ transmission 133 }
 | 
						|
 | 
						|
-- textual conventions
 | 
						|
 | 
						|
OptIfAcTI ::= TEXTUAL-CONVENTION
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The trace identifier (TI) accepted at the receiver."
 | 
						|
  SYNTAX  OCTET STRING (SIZE(64))
 | 
						|
 | 
						|
OptIfBitRateK ::= TEXTUAL-CONVENTION
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the index 'k' that is used to
 | 
						|
     represent a supported bit rate and the different
 | 
						|
     versions of OPUk, ODUk and OTUk.
 | 
						|
     Allowed values of k are defined in ITU-T G.709.
 | 
						|
     Currently allowed values in G.709 are:
 | 
						|
        k=1 represents an approximate bit rate of 2.5 Gbit/s,
 | 
						|
        k=2 represents an approximate bit rate of 10 Gbit/s,
 | 
						|
        k=3 represents an approximate bit rate of 40 Gbit/s."
 | 
						|
  SYNTAX  Integer32
 | 
						|
 | 
						|
OptIfDEGM ::= TEXTUAL-CONVENTION
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the threshold level for declaring a Degraded Signal
 | 
						|
     defect (dDEG).  A dDEG shall be declared if OptIfDEGM
 | 
						|
     consecutive bad PM Seconds are detected."
 | 
						|
  SYNTAX  Unsigned32 (2..10)
 | 
						|
 | 
						|
OptIfDEGThr ::= TEXTUAL-CONVENTION
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the threshold level for declaring a performance
 | 
						|
     monitoring (PM) Second to be bad.  A PM Second is declared bad if
 | 
						|
     the percentage of detected errored blocks in that second is
 | 
						|
     greater than or equal to OptIfDEGThr."
 | 
						|
  SYNTAX  Unsigned32 (1..100)
 | 
						|
 | 
						|
OptIfDirectionality ::= TEXTUAL-CONVENTION
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the directionality of an entity."
 | 
						|
  SYNTAX  INTEGER {
 | 
						|
    sink(1),
 | 
						|
    source(2),
 | 
						|
    bidirectional(3)
 | 
						|
    }
 | 
						|
 | 
						|
OptIfSinkOrSource ::= TEXTUAL-CONVENTION
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the directionality of an entity
 | 
						|
     that is allowed only to be a source or sink."
 | 
						|
  SYNTAX  INTEGER {
 | 
						|
    sink(1),
 | 
						|
    source(2)
 | 
						|
    }
 | 
						|
 | 
						|
OptIfExDAPI ::= TEXTUAL-CONVENTION
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The Destination Access Point Identifier (DAPI)
 | 
						|
     expected by the receiver."
 | 
						|
  SYNTAX  OCTET STRING (SIZE(16))
 | 
						|
 | 
						|
OptIfExSAPI ::= TEXTUAL-CONVENTION
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The Source Access Point Identifier (SAPI)
 | 
						|
     expected by the receiver."
 | 
						|
  SYNTAX  OCTET STRING (SIZE(16))
 | 
						|
 | 
						|
OptIfIntervalNumber ::= TEXTUAL-CONVENTION
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Uniquely identifies a 15-minute interval.  The interval
 | 
						|
     identified by 1 is the most recently completed interval, and
 | 
						|
     the interval identified by n is the interval immediately
 | 
						|
     preceding the one identified by n-1."
 | 
						|
  SYNTAX  Unsigned32 (1..96)
 | 
						|
 | 
						|
OptIfTIMDetMode ::= TEXTUAL-CONVENTION
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the mode of the Trace Identifier Mismatch (TIM)
 | 
						|
     Detection function."
 | 
						|
  SYNTAX  INTEGER {
 | 
						|
    off(1),
 | 
						|
    dapi(2),
 | 
						|
    sapi(3),
 | 
						|
    both(4)
 | 
						|
    }
 | 
						|
 | 
						|
OptIfTxTI ::= TEXTUAL-CONVENTION
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The trace identifier (TI) transmitted."
 | 
						|
  SYNTAX  OCTET STRING (SIZE(64))
 | 
						|
 | 
						|
-- object groups
 | 
						|
 | 
						|
optIfObjects OBJECT IDENTIFIER ::= { optIfMibModule 1 }
 | 
						|
optIfConfs OBJECT IDENTIFIER ::= { optIfMibModule 2 }
 | 
						|
 | 
						|
optIfOTMn OBJECT IDENTIFIER ::= { optIfObjects 1 }
 | 
						|
optIfPerfMon OBJECT IDENTIFIER ::= { optIfObjects 2 }
 | 
						|
optIfOTSn OBJECT IDENTIFIER ::= { optIfObjects 3 }
 | 
						|
optIfOMSn OBJECT IDENTIFIER ::= { optIfObjects 4 }
 | 
						|
optIfOChGroup OBJECT IDENTIFIER ::= { optIfObjects 5 }
 | 
						|
optIfOCh OBJECT IDENTIFIER ::= { optIfObjects 6 }
 | 
						|
 | 
						|
optIfOTUk OBJECT IDENTIFIER ::= { optIfObjects 7 }
 | 
						|
optIfODUk OBJECT IDENTIFIER ::= { optIfObjects 8 }
 | 
						|
optIfODUkT OBJECT IDENTIFIER ::= { optIfObjects 9 }
 | 
						|
 | 
						|
optIfGroups OBJECT IDENTIFIER ::= { optIfConfs 1 }
 | 
						|
optIfCompl OBJECT IDENTIFIER ::= { optIfConfs 2 }
 | 
						|
 | 
						|
-- the optIfOTMn group
 | 
						|
-- This group defines the OTM structure information of an
 | 
						|
-- optical interface.
 | 
						|
 | 
						|
-- OTMn Table
 | 
						|
 | 
						|
optIfOTMnTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfOTMnEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of OTMn structure information."
 | 
						|
  ::= { optIfOTMn 1 }
 | 
						|
 | 
						|
optIfOTMnEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfOTMnEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains the OTMn structure
 | 
						|
     information of an optical interface."
 | 
						|
  INDEX  { ifIndex }
 | 
						|
  ::= { optIfOTMnTable 1 }
 | 
						|
 | 
						|
OptIfOTMnEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfOTMnOrder         Unsigned32,
 | 
						|
    optIfOTMnReduced       TruthValue,
 | 
						|
    optIfOTMnBitRates      BITS,
 | 
						|
    optIfOTMnInterfaceType SnmpAdminString,
 | 
						|
    optIfOTMnTcmMax        Unsigned32,
 | 
						|
    optIfOTMnOpticalReach  INTEGER
 | 
						|
    }
 | 
						|
 | 
						|
optIfOTMnOrder OBJECT-TYPE
 | 
						|
  SYNTAX  Unsigned32 (1..900)
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "This object indicates the order of the OTM, which
 | 
						|
     represents the maximum number of wavelengths that can be
 | 
						|
     supported at the bit rate(s) supported on the interface."
 | 
						|
  ::= { optIfOTMnEntry 1 }
 | 
						|
 | 
						|
optIfOTMnReduced OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "This object indicates whether a reduced or full
 | 
						|
     functionality is supported at the interface.  A value of
 | 
						|
     true means reduced.  A value of false means full."
 | 
						|
  ::= { optIfOTMnEntry 2 }
 | 
						|
 | 
						|
optIfOTMnBitRates OBJECT-TYPE
 | 
						|
  SYNTAX  BITS { bitRateK1(0), bitRateK2(1), bitRateK3(2) }
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "This attribute is a bit map representing the bit
 | 
						|
     rate or set of bit rates supported on the interface.
 | 
						|
     The meaning of each bit position is as follows:
 | 
						|
       bitRateK1(0) is set if the 2.5 Gbit/s rate is supported
 | 
						|
       bitRateK2(1) is set if the 10 Gbit/s rate is supported
 | 
						|
       bitRateK3(2) is set if the 40 Gbit/s rate is supported
 | 
						|
     Note that each bit position corresponds to one possible
 | 
						|
     value of the type OptIfBitRateK.
 | 
						|
     The default value of this attribute is system specific."
 | 
						|
  ::= { optIfOTMnEntry 3 }
 | 
						|
 | 
						|
optIfOTMnInterfaceType OBJECT-TYPE
 | 
						|
  SYNTAX  SnmpAdminString
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "This object identifies the type of interface.  The value of
 | 
						|
     this attribute will affect the behavior of the OTM with
 | 
						|
     respect to presence/absence of OTM Overhead Signal (OOS)
 | 
						|
     processing and TCM activation.  For an IrDI interface,
 | 
						|
     there is no OOS processing and TCM activation is limited
 | 
						|
     to n levels as specified by a TCM level threshold.
 | 
						|
 | 
						|
     This object contains two fields that are separated by
 | 
						|
     whitespace.  The possible values are:
 | 
						|
          field 1: one of the 4-character ASCII strings
 | 
						|
                    'IrDI' or 'IaDI'
 | 
						|
          field 2: free-form text consisting of printable
 | 
						|
                   UTF-8 encoded characters
 | 
						|
 | 
						|
     Note that field 2 is optional.  If it is not present then there
 | 
						|
     is no requirement for trailing whitespace after field 1.
 | 
						|
 | 
						|
     The default values are as follows:
 | 
						|
          field 1:  'IaDI'
 | 
						|
          field 2: an empty string."
 | 
						|
 | 
						|
  ::= { optIfOTMnEntry 4 }
 | 
						|
 | 
						|
optIfOTMnTcmMax OBJECT-TYPE
 | 
						|
  SYNTAX  Unsigned32 (0..6)
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "This object identifies the maximum number of TCM
 | 
						|
     levels allowed for any Optical Channel contained
 | 
						|
     in this OTM.  A new TCM activation will be rejected
 | 
						|
     if the requested level is greater than the threshold.
 | 
						|
     If InterfaceType object specifies a type of 'IaDI'
 | 
						|
     for this OTM, then this attribute is irrelevant.
 | 
						|
 | 
						|
     Possible values:  unsigned integers in the range
 | 
						|
                       from 0 to 6 inclusive.
 | 
						|
     Default value:    3."
 | 
						|
 | 
						|
  ::= { optIfOTMnEntry 5 }
 | 
						|
 | 
						|
optIfOTMnOpticalReach OBJECT-TYPE
 | 
						|
  SYNTAX  INTEGER { intraOffice(1), shortHaul(2), longHaul(3),
 | 
						|
                    veryLongHaul(4), ultraLongHaul(5) }
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "This object indicates the length the optical signal
 | 
						|
     may travel before requiring termination or regeneration.
 | 
						|
     The meaning of the enumeration are:
 | 
						|
       intraOffice(1)  - intra-office (as defined in ITU-T G.957)
 | 
						|
       shortHaul(2)    - short haul (as defined in ITU-T G.957)
 | 
						|
       longHaul(3)     - long haul (as defined in ITU-T G.957)
 | 
						|
       veryLongHaul(4) - very long haul (as defined in ITU-T G.691)
 | 
						|
       ultraLongHaul(5)- ultra long haul (as defined in ITU-T G.691)"
 | 
						|
  ::= { optIfOTMnEntry 6 }
 | 
						|
 | 
						|
-- the optIfPerfMon group
 | 
						|
-- This group defines performance monitoring objects for all
 | 
						|
-- layers.
 | 
						|
 | 
						|
-- PM interval table
 | 
						|
 | 
						|
optIfPerfMonIntervalTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfPerfMonIntervalEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of 15-minute performance monitoring interval
 | 
						|
     information."
 | 
						|
  ::= { optIfPerfMon 1 }
 | 
						|
 | 
						|
optIfPerfMonIntervalEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfPerfMonIntervalEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains 15-minute performance
 | 
						|
     monitoring interval information of an interface."
 | 
						|
  INDEX  { ifIndex }
 | 
						|
  ::= { optIfPerfMonIntervalTable 1 }
 | 
						|
 | 
						|
OptIfPerfMonIntervalEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfPerfMonCurrentTimeElapsed   Gauge32,
 | 
						|
    optIfPerfMonCurDayTimeElapsed    Gauge32,
 | 
						|
    optIfPerfMonIntervalNumIntervals         Unsigned32,
 | 
						|
    optIfPerfMonIntervalNumInvalidIntervals  Unsigned32
 | 
						|
    }
 | 
						|
 | 
						|
optIfPerfMonCurrentTimeElapsed OBJECT-TYPE
 | 
						|
  SYNTAX  Gauge32 (0..900)
 | 
						|
  UNITS  "seconds"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Number of seconds elapsed in the current 15-minute
 | 
						|
     performance monitoring interval.
 | 
						|
     If, for some reason, such as an adjustment in the NE's
 | 
						|
     time-of-day clock, the number of seconds elapsed exceeds
 | 
						|
     the maximum value, then the maximum value will be returned."
 | 
						|
  ::= { optIfPerfMonIntervalEntry 1 }
 | 
						|
 | 
						|
optIfPerfMonCurDayTimeElapsed OBJECT-TYPE
 | 
						|
  SYNTAX  Gauge32 (0..86400)
 | 
						|
  UNITS  "seconds"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Number of seconds elapsed in the current 24-hour interval
 | 
						|
     performance monitoring period.
 | 
						|
     If, for some reason, such as an adjustment in the NE's
 | 
						|
     time-of-day clock, the number of seconds elapsed exceeds
 | 
						|
     the maximum value, then the maximum value will be returned."
 | 
						|
  ::= { optIfPerfMonIntervalEntry 2 }
 | 
						|
 | 
						|
optIfPerfMonIntervalNumIntervals OBJECT-TYPE
 | 
						|
  SYNTAX  Unsigned32 (0..96)
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The number of 15-minute intervals for which performance
 | 
						|
     monitoring data is available.  The number is the same for all
 | 
						|
     the associated sub layers of the interface.
 | 
						|
     An optical interface must be capable of supporting at least
 | 
						|
     n intervals, where n is defined as follows:
 | 
						|
         The minimum value of n is 4.
 | 
						|
         The default of n is 32.
 | 
						|
         The maximum value of n is 96.
 | 
						|
 | 
						|
     The value of this object will be n unless performance
 | 
						|
     monitoring was (re-)started for the interface within the last
 | 
						|
     (n*15) minutes, in which case the value will be the number of
 | 
						|
     complete 15-minute intervals since measurement was
 | 
						|
     (re-)started."
 | 
						|
  ::= { optIfPerfMonIntervalEntry 3 }
 | 
						|
 | 
						|
optIfPerfMonIntervalNumInvalidIntervals OBJECT-TYPE
 | 
						|
  SYNTAX  Unsigned32 (0..96)
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The number of intervals in the range from 0 to
 | 
						|
     optIfPerfMonIntervalNumIntervals for which no performance
 | 
						|
     monitoring data is available and/or the data is invalid."
 | 
						|
  ::= { optIfPerfMonIntervalEntry 4 }
 | 
						|
 | 
						|
-- the optIfOTSn group
 | 
						|
-- This group handles the configuration and performance
 | 
						|
-- monitoring objects for OTS layers.
 | 
						|
 | 
						|
-- OTSn config table
 | 
						|
 | 
						|
optIfOTSnConfigTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfOTSnConfigEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of OTSn configuration information."
 | 
						|
  ::= { optIfOTSn 1 }
 | 
						|
 | 
						|
optIfOTSnConfigEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfOTSnConfigEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains OTSn configuration
 | 
						|
     information of an interface."
 | 
						|
  INDEX  { ifIndex }
 | 
						|
  ::= { optIfOTSnConfigTable 1 }
 | 
						|
 | 
						|
OptIfOTSnConfigEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfOTSnDirectionality              OptIfDirectionality,
 | 
						|
    optIfOTSnAprStatus                   SnmpAdminString,
 | 
						|
    optIfOTSnAprControl                  SnmpAdminString,
 | 
						|
    optIfOTSnTraceIdentifierTransmitted  OptIfTxTI,
 | 
						|
    optIfOTSnDAPIExpected                OptIfExDAPI,
 | 
						|
    optIfOTSnSAPIExpected                OptIfExSAPI,
 | 
						|
    optIfOTSnTraceIdentifierAccepted     OptIfAcTI,
 | 
						|
    optIfOTSnTIMDetMode                  OptIfTIMDetMode,
 | 
						|
    optIfOTSnTIMActEnabled               TruthValue,
 | 
						|
    optIfOTSnCurrentStatus               BITS
 | 
						|
    }
 | 
						|
 | 
						|
optIfOTSnDirectionality OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfDirectionality
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the directionality of the entity."
 | 
						|
  ::= { optIfOTSnConfigEntry 1 }
 | 
						|
 | 
						|
optIfOTSnAprStatus OBJECT-TYPE
 | 
						|
  SYNTAX  SnmpAdminString
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "This attribute indicates the status of the Automatic
 | 
						|
     Power Reduction (APR) function of the entity.  Valid
 | 
						|
     values are 'on' and 'off'."
 | 
						|
  ::= { optIfOTSnConfigEntry 2 }
 | 
						|
 | 
						|
optIfOTSnAprControl OBJECT-TYPE
 | 
						|
  SYNTAX  SnmpAdminString
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "This object is a UTF-8 encoded string that specifies Automatic
 | 
						|
     Power Reduction (APR) control actions requested of this entity
 | 
						|
     (when written) and that returns the current APR control state
 | 
						|
     of this entity (when read).  The values are implementation-defined.
 | 
						|
     Any implementation that instantiates this object must document the
 | 
						|
     set of values that it allows to be written, the set of values
 | 
						|
     that it will return, and what each of those values means."
 | 
						|
  ::= { optIfOTSnConfigEntry 3 }
 | 
						|
 | 
						|
optIfOTSnTraceIdentifierTransmitted OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfTxTI
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The trace identifier transmitted.
 | 
						|
     This object is applicable when optIfOTSnDirectionality has the
 | 
						|
     value source(2) or bidirectional(3).
 | 
						|
     This object does not apply to reduced-capability systems (i.e.,
 | 
						|
     those for which optIfOTMnReduced has the value true(1)) or
 | 
						|
     at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1
 | 
						|
     has the value 'IrDI').
 | 
						|
     If no value is ever set by a management entity for the object
 | 
						|
     optIfOTSnTraceIdentifierTransmitted, system-specific default
 | 
						|
     value will be used.  Any implementation that instantiates this
 | 
						|
     object must document the system-specific default value or how it
 | 
						|
     is derived."
 | 
						|
  ::= { optIfOTSnConfigEntry 4 }
 | 
						|
 | 
						|
optIfOTSnDAPIExpected OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfExDAPI
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The DAPI expected by the receiver.
 | 
						|
     This object is applicable when optIfOTSnDirectionality has the
 | 
						|
     value sink(1) or bidirectional(3).  It has no effect if
 | 
						|
     optIfOTSnTIMDetMode has the value off(1) or sapi(3).
 | 
						|
     This object does not apply to reduced-capability systems (i.e.,
 | 
						|
     those for which optIfOTMnReduced has the value true(1)) or
 | 
						|
     at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1
 | 
						|
     has the value 'IrDI')."
 | 
						|
  ::= { optIfOTSnConfigEntry 5 }
 | 
						|
 | 
						|
optIfOTSnSAPIExpected OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfExSAPI
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The SAPI expected by the receiver.
 | 
						|
     This object is applicable when optIfOTSnDirectionality has the
 | 
						|
     value sink(1) or bidirectional(3).  It has no effect if
 | 
						|
     optIfOTSnTIMDetMode has the value off(1) or dapi(2).
 | 
						|
     This object does not apply to reduced-capability systems (i.e.,
 | 
						|
     those for which optIfOTMnReduced has the value true(1)) or
 | 
						|
     at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1
 | 
						|
     has the value 'IrDI')."
 | 
						|
  ::= { optIfOTSnConfigEntry 6 }
 | 
						|
 | 
						|
optIfOTSnTraceIdentifierAccepted OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfAcTI
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The actual trace identifier received.
 | 
						|
     This object is applicable when optIfOTSnDirectionality has the
 | 
						|
     value sink(1) or bidirectional(3).  Its value is unspecified
 | 
						|
     if optIfOTSnCurrentStatus has either or both of the
 | 
						|
     losO(5) and los(6) bits set.
 | 
						|
     This object does not apply to reduced-capability systems (i.e.,
 | 
						|
     those for which optIfOTMnReduced has the value true(1)) or
 | 
						|
     at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1
 | 
						|
     has the value 'IrDI')."
 | 
						|
  ::= { optIfOTSnConfigEntry 7 }
 | 
						|
 | 
						|
optIfOTSnTIMDetMode OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfTIMDetMode
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the mode of the Trace Identifier Mismatch (TIM)
 | 
						|
     Detection function.  This object is applicable
 | 
						|
     when optIfOTSnDirectionality has the value sink(1)
 | 
						|
     or bidirectional(3).  The default value is off(1).
 | 
						|
     This object does not apply to reduced-capability systems (i.e.,
 | 
						|
     those for which optIfOTMnReduced has the value true(1)) or
 | 
						|
     at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1
 | 
						|
     has the value 'IrDI').
 | 
						|
     The default value of this object is off(1)."
 | 
						|
  ::= { optIfOTSnConfigEntry 8 }
 | 
						|
 | 
						|
optIfOTSnTIMActEnabled OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates whether the Trace Identifier Mismatch (TIM)
 | 
						|
     Consequent Action function is enabled.  This object
 | 
						|
     is applicable when optIfOTSnDirectionality has the
 | 
						|
     value sink(1) or bidirectional(3).  It has no effect
 | 
						|
     when the value of optIfOTSnTIMDetMode is off(1).
 | 
						|
     This object does not apply to reduced-capability systems (i.e.,
 | 
						|
     those for which optIfOTMnReduced has the value true(1)) or
 | 
						|
     at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1
 | 
						|
     has the value 'IrDI').
 | 
						|
     The default value of this object is false(2)."
 | 
						|
  ::= { optIfOTSnConfigEntry 9 }
 | 
						|
 | 
						|
optIfOTSnCurrentStatus OBJECT-TYPE
 | 
						|
  SYNTAX  BITS {
 | 
						|
    bdiP(0),
 | 
						|
    bdiO(1),
 | 
						|
    bdi(2),
 | 
						|
    tim(3),
 | 
						|
    losP(4),
 | 
						|
    losO(5),
 | 
						|
    los(6)
 | 
						|
    }
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the defect condition of the entity, if any.
 | 
						|
     This object is applicable when optIfOTSnDirectionality
 | 
						|
     has the value sink(1) or bidirectional(3).  In
 | 
						|
     reduced-capability systems or at IrDI interfaces
 | 
						|
     the only bit position that may be set is los(6)."
 | 
						|
  ::= { optIfOTSnConfigEntry 10 }
 | 
						|
 | 
						|
-- OTSn sink current table
 | 
						|
-- Contains data for the current 15-minute performance monitoring
 | 
						|
-- interval.
 | 
						|
 | 
						|
optIfOTSnSinkCurrentTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfOTSnSinkCurrentEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of OTSn sink performance monitoring information for
 | 
						|
     the current 15-minute interval."
 | 
						|
  ::= { optIfOTSn 2 }
 | 
						|
 | 
						|
optIfOTSnSinkCurrentEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfOTSnSinkCurrentEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains OTSn sink performance
 | 
						|
     monitoring information of an interface for the current
 | 
						|
     15-minute interval."
 | 
						|
  INDEX  { ifIndex }
 | 
						|
  ::= { optIfOTSnSinkCurrentTable 1 }
 | 
						|
 | 
						|
OptIfOTSnSinkCurrentEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfOTSnSinkCurrentSuspectedFlag             TruthValue,
 | 
						|
    optIfOTSnSinkCurrentInputPower                Integer32,
 | 
						|
    optIfOTSnSinkCurrentLowInputPower             Integer32,
 | 
						|
    optIfOTSnSinkCurrentHighInputPower            Integer32,
 | 
						|
    optIfOTSnSinkCurrentLowerInputPowerThreshold  Integer32,
 | 
						|
    optIfOTSnSinkCurrentUpperInputPowerThreshold  Integer32,
 | 
						|
    optIfOTSnSinkCurrentOutputPower               Integer32,
 | 
						|
    optIfOTSnSinkCurrentLowOutputPower            Integer32,
 | 
						|
    optIfOTSnSinkCurrentHighOutputPower           Integer32,
 | 
						|
    optIfOTSnSinkCurrentLowerOutputPowerThreshold Integer32,
 | 
						|
    optIfOTSnSinkCurrentUpperOutputPowerThreshold Integer32
 | 
						|
    }
 | 
						|
 | 
						|
optIfOTSnSinkCurrentSuspectedFlag OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "If true, the data in this entry may be unreliable."
 | 
						|
  ::= { optIfOTSnSinkCurrentEntry 1 }
 | 
						|
 | 
						|
optIfOTSnSinkCurrentInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The optical power monitored at the input."
 | 
						|
  ::= { optIfOTSnSinkCurrentEntry 2 }
 | 
						|
 | 
						|
optIfOTSnSinkCurrentLowInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest optical power monitored at the input during the
 | 
						|
     current 15-minute interval."
 | 
						|
  ::= { optIfOTSnSinkCurrentEntry 3 }
 | 
						|
 | 
						|
optIfOTSnSinkCurrentHighInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest optical power monitored at the input during the
 | 
						|
     current 15-minute interval."
 | 
						|
  ::= { optIfOTSnSinkCurrentEntry 4 }
 | 
						|
 | 
						|
optIfOTSnSinkCurrentLowerInputPowerThreshold OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lower limit threshold on input power.  If
 | 
						|
     optIfOTSnSinkCurrentInputPower drops to this value or below,
 | 
						|
     a Threshold Crossing Alert (TCA) should be sent."
 | 
						|
  ::= { optIfOTSnSinkCurrentEntry 5 }
 | 
						|
 | 
						|
optIfOTSnSinkCurrentUpperInputPowerThreshold OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The upper limit threshold on input power.  If
 | 
						|
     optIfOTSnSinkCurrentInputPower reaches or exceeds this value,
 | 
						|
     a Threshold Crossing Alert (TCA) should be sent."
 | 
						|
  ::= { optIfOTSnSinkCurrentEntry 6 }
 | 
						|
 | 
						|
optIfOTSnSinkCurrentOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The optical power monitored at the output."
 | 
						|
  ::= { optIfOTSnSinkCurrentEntry 7 }
 | 
						|
 | 
						|
optIfOTSnSinkCurrentLowOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest optical power monitored at the output during the
 | 
						|
     current 15-minute interval."
 | 
						|
  ::= { optIfOTSnSinkCurrentEntry 8 }
 | 
						|
 | 
						|
optIfOTSnSinkCurrentHighOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest optical power monitored at the output during the
 | 
						|
     current 15-minute interval."
 | 
						|
  ::= { optIfOTSnSinkCurrentEntry 9 }
 | 
						|
 | 
						|
optIfOTSnSinkCurrentLowerOutputPowerThreshold OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lower limit threshold on output power.  If
 | 
						|
     optIfOTSnSinkCurrentOutputPower drops to this value or below,
 | 
						|
     a Threshold Crossing Alert (TCA) should be sent."
 | 
						|
  ::= { optIfOTSnSinkCurrentEntry 10 }
 | 
						|
 | 
						|
optIfOTSnSinkCurrentUpperOutputPowerThreshold OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The upper limit threshold on output power.  If
 | 
						|
     optIfOTSnSinkCurrentOutputPower reaches or exceeds this value,
 | 
						|
     a Threshold Crossing Alert (TCA) should be sent."
 | 
						|
  ::= { optIfOTSnSinkCurrentEntry 11 }
 | 
						|
 | 
						|
-- OTSn sink interval table
 | 
						|
-- Contains data for previous 15-minute performance monitoring
 | 
						|
-- intervals.
 | 
						|
 | 
						|
optIfOTSnSinkIntervalTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfOTSnSinkIntervalEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of historical OTSn sink performance monitoring
 | 
						|
     information."
 | 
						|
  ::= { optIfOTSn 3 }
 | 
						|
 | 
						|
optIfOTSnSinkIntervalEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfOTSnSinkIntervalEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains OTSn sink performance
 | 
						|
     monitoring information of an interface during a particular
 | 
						|
     historical interval."
 | 
						|
  INDEX  { ifIndex, optIfOTSnSinkIntervalNumber }
 | 
						|
  ::= { optIfOTSnSinkIntervalTable 1 }
 | 
						|
 | 
						|
OptIfOTSnSinkIntervalEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfOTSnSinkIntervalNumber           OptIfIntervalNumber,
 | 
						|
    optIfOTSnSinkIntervalSuspectedFlag    TruthValue,
 | 
						|
    optIfOTSnSinkIntervalLastInputPower   Integer32,
 | 
						|
    optIfOTSnSinkIntervalLowInputPower    Integer32,
 | 
						|
    optIfOTSnSinkIntervalHighInputPower   Integer32,
 | 
						|
    optIfOTSnSinkIntervalLastOutputPower  Integer32,
 | 
						|
    optIfOTSnSinkIntervalLowOutputPower   Integer32,
 | 
						|
    optIfOTSnSinkIntervalHighOutputPower  Integer32
 | 
						|
 | 
						|
    }
 | 
						|
 | 
						|
optIfOTSnSinkIntervalNumber OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfIntervalNumber
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Uniquely identifies the interval."
 | 
						|
  ::= { optIfOTSnSinkIntervalEntry 1 }
 | 
						|
 | 
						|
optIfOTSnSinkIntervalSuspectedFlag OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "If true, the data in this entry may be unreliable."
 | 
						|
  ::= { optIfOTSnSinkIntervalEntry 2 }
 | 
						|
 | 
						|
optIfOTSnSinkIntervalLastInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The last optical power monitored at the input during the
 | 
						|
     interval."
 | 
						|
  ::= { optIfOTSnSinkIntervalEntry 3 }
 | 
						|
 | 
						|
optIfOTSnSinkIntervalLowInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest optical power monitored at the input during the
 | 
						|
     interval."
 | 
						|
  ::= { optIfOTSnSinkIntervalEntry 4 }
 | 
						|
 | 
						|
 | 
						|
optIfOTSnSinkIntervalHighInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest optical power monitored at the input during the
 | 
						|
     interval."
 | 
						|
  ::= { optIfOTSnSinkIntervalEntry 5 }
 | 
						|
 | 
						|
optIfOTSnSinkIntervalLastOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The last optical power monitored at the output during the
 | 
						|
     interval."
 | 
						|
  ::= { optIfOTSnSinkIntervalEntry 6 }
 | 
						|
 | 
						|
optIfOTSnSinkIntervalLowOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest optical power monitored at the output during the
 | 
						|
     interval."
 | 
						|
  ::= { optIfOTSnSinkIntervalEntry 7 }
 | 
						|
 | 
						|
optIfOTSnSinkIntervalHighOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest optical power monitored at the output during the
 | 
						|
     interval."
 | 
						|
  ::= { optIfOTSnSinkIntervalEntry 8 }
 | 
						|
 | 
						|
-- OTSn sink current day table
 | 
						|
-- Contains data for the current 24-hour performance
 | 
						|
-- monitoring interval.
 | 
						|
 | 
						|
optIfOTSnSinkCurDayTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfOTSnSinkCurDayEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of OTSn sink performance monitoring information for
 | 
						|
     the current 24-hour interval."
 | 
						|
  ::= { optIfOTSn 4 }
 | 
						|
 | 
						|
optIfOTSnSinkCurDayEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfOTSnSinkCurDayEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains OTSn sink performance
 | 
						|
     monitoring information of an interface for the current
 | 
						|
     24-hour interval."
 | 
						|
  INDEX  { ifIndex }
 | 
						|
  ::= { optIfOTSnSinkCurDayTable 1 }
 | 
						|
 | 
						|
OptIfOTSnSinkCurDayEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfOTSnSinkCurDaySuspectedFlag    TruthValue,
 | 
						|
    optIfOTSnSinkCurDayLowInputPower    Integer32,
 | 
						|
    optIfOTSnSinkCurDayHighInputPower   Integer32,
 | 
						|
    optIfOTSnSinkCurDayLowOutputPower   Integer32,
 | 
						|
    optIfOTSnSinkCurDayHighOutputPower  Integer32
 | 
						|
    }
 | 
						|
 | 
						|
optIfOTSnSinkCurDaySuspectedFlag OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "If true, the data in this entry may be unreliable."
 | 
						|
  ::= { optIfOTSnSinkCurDayEntry 1 }
 | 
						|
 | 
						|
optIfOTSnSinkCurDayLowInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest optical power monitored at the input during the
 | 
						|
     current 24-hour interval."
 | 
						|
  ::= { optIfOTSnSinkCurDayEntry 2 }
 | 
						|
 | 
						|
optIfOTSnSinkCurDayHighInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest optical power monitored at the input during the
 | 
						|
     current 24-hour interval."
 | 
						|
  ::= { optIfOTSnSinkCurDayEntry 3 }
 | 
						|
 | 
						|
optIfOTSnSinkCurDayLowOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest optical power monitored at the output during the
 | 
						|
     current 24-hour interval."
 | 
						|
  ::= { optIfOTSnSinkCurDayEntry 4 }
 | 
						|
 | 
						|
optIfOTSnSinkCurDayHighOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest optical power monitored at the output during the
 | 
						|
     current 24-hour interval."
 | 
						|
  ::= { optIfOTSnSinkCurDayEntry 5 }
 | 
						|
 | 
						|
-- OTSn sink previous day table
 | 
						|
-- Contains data for the previous 24-hour performance
 | 
						|
-- monitoring interval.
 | 
						|
 | 
						|
optIfOTSnSinkPrevDayTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfOTSnSinkPrevDayEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of OTSn sink performance monitoring information for
 | 
						|
     the previous 24-hour interval."
 | 
						|
  ::= { optIfOTSn 5 }
 | 
						|
 | 
						|
optIfOTSnSinkPrevDayEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfOTSnSinkPrevDayEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains OTSn sink performance
 | 
						|
     monitoring information of an interface for the previous
 | 
						|
     24-hour interval."
 | 
						|
  INDEX  { ifIndex }
 | 
						|
  ::= { optIfOTSnSinkPrevDayTable 1 }
 | 
						|
 | 
						|
 | 
						|
OptIfOTSnSinkPrevDayEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfOTSnSinkPrevDaySuspectedFlag    TruthValue,
 | 
						|
    optIfOTSnSinkPrevDayLastInputPower   Integer32,
 | 
						|
    optIfOTSnSinkPrevDayLowInputPower    Integer32,
 | 
						|
    optIfOTSnSinkPrevDayHighInputPower   Integer32,
 | 
						|
    optIfOTSnSinkPrevDayLastOutputPower  Integer32,
 | 
						|
    optIfOTSnSinkPrevDayLowOutputPower   Integer32,
 | 
						|
    optIfOTSnSinkPrevDayHighOutputPower  Integer32
 | 
						|
    }
 | 
						|
 | 
						|
optIfOTSnSinkPrevDaySuspectedFlag OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "If true, the data in this entry may be unreliable."
 | 
						|
  ::= { optIfOTSnSinkPrevDayEntry 1 }
 | 
						|
 | 
						|
optIfOTSnSinkPrevDayLastInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The last optical power monitored at the input during the
 | 
						|
     previous 24-hour interval."
 | 
						|
  ::= { optIfOTSnSinkPrevDayEntry 2 }
 | 
						|
 | 
						|
optIfOTSnSinkPrevDayLowInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest optical power monitored at the input during the
 | 
						|
     previous 24-hour interval."
 | 
						|
  ::= { optIfOTSnSinkPrevDayEntry 3 }
 | 
						|
 | 
						|
optIfOTSnSinkPrevDayHighInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest optical power monitored at the input during the
 | 
						|
     previous 24-hour interval."
 | 
						|
  ::= { optIfOTSnSinkPrevDayEntry 4 }
 | 
						|
 | 
						|
 | 
						|
optIfOTSnSinkPrevDayLastOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The last optical power monitored at the output during the
 | 
						|
     previous 24-hour interval."
 | 
						|
  ::= { optIfOTSnSinkPrevDayEntry 5 }
 | 
						|
 | 
						|
optIfOTSnSinkPrevDayLowOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest optical power monitored at the output during the
 | 
						|
     previous 24-hour interval."
 | 
						|
  ::= { optIfOTSnSinkPrevDayEntry 6 }
 | 
						|
 | 
						|
optIfOTSnSinkPrevDayHighOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest optical power monitored at the output during the
 | 
						|
     previous 24-hour interval."
 | 
						|
  ::= { optIfOTSnSinkPrevDayEntry 7 }
 | 
						|
 | 
						|
-- OTSn source current table
 | 
						|
-- Contains data for the current 15-minute performance monitoring
 | 
						|
-- interval.
 | 
						|
 | 
						|
optIfOTSnSrcCurrentTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfOTSnSrcCurrentEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of OTSn source performance monitoring information for
 | 
						|
     the current 15-minute interval."
 | 
						|
  ::= { optIfOTSn 6 }
 | 
						|
 | 
						|
optIfOTSnSrcCurrentEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfOTSnSrcCurrentEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
 | 
						|
 | 
						|
    "A conceptual row that contains OTSn source performance
 | 
						|
     monitoring information of an interface for the current
 | 
						|
     15-minute interval."
 | 
						|
  INDEX  { ifIndex }
 | 
						|
  ::= { optIfOTSnSrcCurrentTable 1 }
 | 
						|
 | 
						|
OptIfOTSnSrcCurrentEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfOTSnSrcCurrentSuspectedFlag              TruthValue,
 | 
						|
    optIfOTSnSrcCurrentOutputPower                Integer32,
 | 
						|
    optIfOTSnSrcCurrentLowOutputPower             Integer32,
 | 
						|
    optIfOTSnSrcCurrentHighOutputPower            Integer32,
 | 
						|
    optIfOTSnSrcCurrentLowerOutputPowerThreshold  Integer32,
 | 
						|
    optIfOTSnSrcCurrentUpperOutputPowerThreshold  Integer32,
 | 
						|
    optIfOTSnSrcCurrentInputPower                 Integer32,
 | 
						|
    optIfOTSnSrcCurrentLowInputPower              Integer32,
 | 
						|
    optIfOTSnSrcCurrentHighInputPower             Integer32,
 | 
						|
    optIfOTSnSrcCurrentLowerInputPowerThreshold   Integer32,
 | 
						|
    optIfOTSnSrcCurrentUpperInputPowerThreshold   Integer32
 | 
						|
    }
 | 
						|
 | 
						|
optIfOTSnSrcCurrentSuspectedFlag OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "If true, the data in this entry may be unreliable."
 | 
						|
  ::= { optIfOTSnSrcCurrentEntry 1 }
 | 
						|
 | 
						|
optIfOTSnSrcCurrentOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The optical power monitored at the output."
 | 
						|
  ::= { optIfOTSnSrcCurrentEntry 2 }
 | 
						|
 | 
						|
optIfOTSnSrcCurrentLowOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest optical power monitored at the output during the
 | 
						|
     current 15-minute interval."
 | 
						|
  ::= { optIfOTSnSrcCurrentEntry 3 }
 | 
						|
 | 
						|
 | 
						|
optIfOTSnSrcCurrentHighOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest optical power monitored at the output during the
 | 
						|
     current 15-minute interval."
 | 
						|
  ::= { optIfOTSnSrcCurrentEntry 4 }
 | 
						|
 | 
						|
optIfOTSnSrcCurrentLowerOutputPowerThreshold OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lower limit threshold on output power.  If
 | 
						|
     optIfOTSnSrcCurrentOutputPower drops to this value or below,
 | 
						|
     a Threshold Crossing Alert (TCA) should be sent."
 | 
						|
  ::= { optIfOTSnSrcCurrentEntry 5 }
 | 
						|
 | 
						|
optIfOTSnSrcCurrentUpperOutputPowerThreshold OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The upper limit threshold on output power.  If
 | 
						|
     optIfOTSnSrcCurrentOutputPower reaches or exceeds this value,
 | 
						|
     a Threshold Crossing Alert (TCA) should be sent."
 | 
						|
  ::= { optIfOTSnSrcCurrentEntry 6 }
 | 
						|
 | 
						|
optIfOTSnSrcCurrentInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The optical power monitored at the input."
 | 
						|
  ::= { optIfOTSnSrcCurrentEntry 7 }
 | 
						|
 | 
						|
optIfOTSnSrcCurrentLowInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
 | 
						|
  DESCRIPTION
 | 
						|
 | 
						|
 | 
						|
    "The lowest optical power monitored at the input during the
 | 
						|
     current 15-minute interval."
 | 
						|
  ::= { optIfOTSnSrcCurrentEntry 8 }
 | 
						|
 | 
						|
optIfOTSnSrcCurrentHighInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest optical power monitored at the input during the
 | 
						|
     current 15-minute interval."
 | 
						|
  ::= { optIfOTSnSrcCurrentEntry 9 }
 | 
						|
 | 
						|
optIfOTSnSrcCurrentLowerInputPowerThreshold OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lower limit threshold on input power.  If
 | 
						|
     optIfOTSnSrcCurrentInputPower drops to this value or below,
 | 
						|
     a Threshold Crossing Alert (TCA) should be sent."
 | 
						|
  ::= { optIfOTSnSrcCurrentEntry 10 }
 | 
						|
 | 
						|
optIfOTSnSrcCurrentUpperInputPowerThreshold OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The upper limit threshold on input power.  If
 | 
						|
     optIfOTSnSrcCurrentInputPower reaches or exceeds this value,
 | 
						|
     a Threshold Crossing Alert (TCA) should be sent."
 | 
						|
  ::= { optIfOTSnSrcCurrentEntry 11 }
 | 
						|
 | 
						|
-- OTSn source interval table
 | 
						|
-- Contains data for previous 15-minute performance monitoring
 | 
						|
-- intervals.
 | 
						|
 | 
						|
optIfOTSnSrcIntervalTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfOTSnSrcIntervalEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of historical OTSn source performance monitoring
 | 
						|
     information."
 | 
						|
  ::= { optIfOTSn 7 }
 | 
						|
 | 
						|
 | 
						|
optIfOTSnSrcIntervalEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfOTSnSrcIntervalEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains OTSn source performance
 | 
						|
     monitoring information of an interface during a particular
 | 
						|
     historical interval."
 | 
						|
  INDEX  { ifIndex, optIfOTSnSrcIntervalNumber }
 | 
						|
  ::= { optIfOTSnSrcIntervalTable 1 }
 | 
						|
 | 
						|
OptIfOTSnSrcIntervalEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfOTSnSrcIntervalNumber           OptIfIntervalNumber,
 | 
						|
    optIfOTSnSrcIntervalSuspectedFlag    TruthValue,
 | 
						|
    optIfOTSnSrcIntervalLastOutputPower  Integer32,
 | 
						|
    optIfOTSnSrcIntervalLowOutputPower   Integer32,
 | 
						|
    optIfOTSnSrcIntervalHighOutputPower  Integer32,
 | 
						|
    optIfOTSnSrcIntervalLastInputPower   Integer32,
 | 
						|
    optIfOTSnSrcIntervalLowInputPower    Integer32,
 | 
						|
    optIfOTSnSrcIntervalHighInputPower   Integer32
 | 
						|
    }
 | 
						|
 | 
						|
optIfOTSnSrcIntervalNumber OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfIntervalNumber
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Uniquely identifies the interval."
 | 
						|
  ::= { optIfOTSnSrcIntervalEntry 1 }
 | 
						|
 | 
						|
optIfOTSnSrcIntervalSuspectedFlag OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "If true, the data in this entry may be unreliable."
 | 
						|
  ::= { optIfOTSnSrcIntervalEntry 2 }
 | 
						|
 | 
						|
optIfOTSnSrcIntervalLastOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The last optical power monitored at the output during the
 | 
						|
     interval."
 | 
						|
  ::= { optIfOTSnSrcIntervalEntry 3 }
 | 
						|
 | 
						|
 | 
						|
optIfOTSnSrcIntervalLowOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest optical power monitored at the output during the
 | 
						|
     interval."
 | 
						|
  ::= { optIfOTSnSrcIntervalEntry 4 }
 | 
						|
 | 
						|
optIfOTSnSrcIntervalHighOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest optical power monitored at the output during the
 | 
						|
     interval."
 | 
						|
  ::= { optIfOTSnSrcIntervalEntry 5 }
 | 
						|
 | 
						|
optIfOTSnSrcIntervalLastInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The last optical power monitored at the input during the
 | 
						|
     interval."
 | 
						|
  ::= { optIfOTSnSrcIntervalEntry 6 }
 | 
						|
 | 
						|
optIfOTSnSrcIntervalLowInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest optical power monitored at the input during the
 | 
						|
     interval."
 | 
						|
  ::= { optIfOTSnSrcIntervalEntry 7 }
 | 
						|
 | 
						|
optIfOTSnSrcIntervalHighInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest optical power monitored at the input during the
 | 
						|
     interval."
 | 
						|
 | 
						|
 | 
						|
  ::= { optIfOTSnSrcIntervalEntry 8 }
 | 
						|
 | 
						|
 | 
						|
-- OTSn source current day table
 | 
						|
-- Contains data for the current 24-hour performance
 | 
						|
-- monitoring interval.
 | 
						|
 | 
						|
optIfOTSnSrcCurDayTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfOTSnSrcCurDayEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of OTSn source performance monitoring information for
 | 
						|
     the current 24-hour interval."
 | 
						|
  ::= { optIfOTSn 8 }
 | 
						|
 | 
						|
optIfOTSnSrcCurDayEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfOTSnSrcCurDayEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains OTSn source performance
 | 
						|
     monitoring information of an interface for the current
 | 
						|
     24-hour interval."
 | 
						|
  INDEX  { ifIndex }
 | 
						|
  ::= { optIfOTSnSrcCurDayTable 1 }
 | 
						|
 | 
						|
OptIfOTSnSrcCurDayEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfOTSnSrcCurDaySuspectedFlag    TruthValue,
 | 
						|
    optIfOTSnSrcCurDayLowOutputPower   Integer32,
 | 
						|
    optIfOTSnSrcCurDayHighOutputPower  Integer32,
 | 
						|
    optIfOTSnSrcCurDayLowInputPower    Integer32,
 | 
						|
    optIfOTSnSrcCurDayHighInputPower   Integer32
 | 
						|
    }
 | 
						|
 | 
						|
optIfOTSnSrcCurDaySuspectedFlag OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "If true, the data in this entry may be unreliable."
 | 
						|
  ::= { optIfOTSnSrcCurDayEntry 1 }
 | 
						|
 | 
						|
optIfOTSnSrcCurDayLowOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest optical power monitored at the output during the
 | 
						|
     current 24-hour interval."
 | 
						|
  ::= { optIfOTSnSrcCurDayEntry 2 }
 | 
						|
 | 
						|
optIfOTSnSrcCurDayHighOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest optical power monitored at the output during the
 | 
						|
     current 24-hour interval."
 | 
						|
  ::= { optIfOTSnSrcCurDayEntry 3 }
 | 
						|
 | 
						|
optIfOTSnSrcCurDayLowInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest optical power monitored at the input during the
 | 
						|
     current 24-hour interval."
 | 
						|
  ::= { optIfOTSnSrcCurDayEntry 4 }
 | 
						|
 | 
						|
optIfOTSnSrcCurDayHighInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest optical power monitored at the input during the
 | 
						|
     current 24-hour interval."
 | 
						|
  ::= { optIfOTSnSrcCurDayEntry 5 }
 | 
						|
 | 
						|
-- OTSn source previous day table
 | 
						|
-- Contains data for the previous 24-hour performance
 | 
						|
-- monitoring interval.
 | 
						|
 | 
						|
optIfOTSnSrcPrevDayTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfOTSnSrcPrevDayEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of OTSn source performance monitoring information for
 | 
						|
     the previous 24-hour interval."
 | 
						|
  ::= { optIfOTSn 9 }
 | 
						|
 | 
						|
 | 
						|
optIfOTSnSrcPrevDayEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfOTSnSrcPrevDayEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains OTSn source performance
 | 
						|
     monitoring information of an interface for the previous
 | 
						|
     24-hour interval."
 | 
						|
  INDEX  { ifIndex }
 | 
						|
  ::= { optIfOTSnSrcPrevDayTable 1 }
 | 
						|
 | 
						|
OptIfOTSnSrcPrevDayEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfOTSnSrcPrevDaySuspectedFlag    TruthValue,
 | 
						|
    optIfOTSnSrcPrevDayLastOutputPower  Integer32,
 | 
						|
    optIfOTSnSrcPrevDayLowOutputPower   Integer32,
 | 
						|
    optIfOTSnSrcPrevDayHighOutputPower  Integer32,
 | 
						|
    optIfOTSnSrcPrevDayLastInputPower   Integer32,
 | 
						|
    optIfOTSnSrcPrevDayLowInputPower    Integer32,
 | 
						|
    optIfOTSnSrcPrevDayHighInputPower   Integer32
 | 
						|
    }
 | 
						|
 | 
						|
optIfOTSnSrcPrevDaySuspectedFlag OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "If true, the data in this entry may be unreliable."
 | 
						|
  ::= { optIfOTSnSrcPrevDayEntry 1 }
 | 
						|
 | 
						|
optIfOTSnSrcPrevDayLastOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The last optical power monitored at the output during the
 | 
						|
     previous 24-hour interval."
 | 
						|
  ::= { optIfOTSnSrcPrevDayEntry 2 }
 | 
						|
 | 
						|
optIfOTSnSrcPrevDayLowOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest optical power monitored at the output during the
 | 
						|
     previous 24-hour interval."
 | 
						|
 | 
						|
 | 
						|
  ::= { optIfOTSnSrcPrevDayEntry 3 }
 | 
						|
 | 
						|
optIfOTSnSrcPrevDayHighOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest optical power monitored at the output during the
 | 
						|
     previous 24-hour interval."
 | 
						|
  ::= { optIfOTSnSrcPrevDayEntry 4 }
 | 
						|
 | 
						|
optIfOTSnSrcPrevDayLastInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The last optical power monitored at the input during the
 | 
						|
     previous 24-hour interval."
 | 
						|
  ::= { optIfOTSnSrcPrevDayEntry 5 }
 | 
						|
 | 
						|
optIfOTSnSrcPrevDayLowInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest optical power monitored at the input during the
 | 
						|
     previous 24-hour interval."
 | 
						|
  ::= { optIfOTSnSrcPrevDayEntry 6 }
 | 
						|
 | 
						|
optIfOTSnSrcPrevDayHighInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest optical power monitored at the input during the
 | 
						|
     previous 24-hour interval."
 | 
						|
  ::= { optIfOTSnSrcPrevDayEntry 7 }
 | 
						|
 | 
						|
 | 
						|
-- the optIfOMSn group
 | 
						|
-- This group handles the configuration and performance monitoring
 | 
						|
-- information for OMS layers.
 | 
						|
 | 
						|
-- OMSn config table
 | 
						|
 | 
						|
optIfOMSnConfigTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfOMSnConfigEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of OMSn configuration information."
 | 
						|
  ::= { optIfOMSn 1 }
 | 
						|
 | 
						|
optIfOMSnConfigEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfOMSnConfigEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains OMSn configuration
 | 
						|
     information of an interface."
 | 
						|
  INDEX  { ifIndex }
 | 
						|
  ::= { optIfOMSnConfigTable 1 }
 | 
						|
 | 
						|
OptIfOMSnConfigEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfOMSnDirectionality OptIfDirectionality,
 | 
						|
    optIfOMSnCurrentStatus  BITS
 | 
						|
    }
 | 
						|
 | 
						|
optIfOMSnDirectionality OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfDirectionality
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the directionality of the entity."
 | 
						|
  ::= { optIfOMSnConfigEntry 1 }
 | 
						|
 | 
						|
optIfOMSnCurrentStatus OBJECT-TYPE
 | 
						|
  SYNTAX  BITS {
 | 
						|
    ssfP(0),
 | 
						|
    ssfO(1),
 | 
						|
    ssf(2),
 | 
						|
    bdiP(3),
 | 
						|
    bdiO(4),
 | 
						|
    bdi(5),
 | 
						|
    losP(6)
 | 
						|
    }
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the defect condition of the entity, if any.
 | 
						|
     This object is applicable only to full capability
 | 
						|
     systems whose interface type is IaDI and for which
 | 
						|
 | 
						|
 | 
						|
     optIfOMSnDirectionality has the value sink(1) or
 | 
						|
     bidirectional(3)."
 | 
						|
  ::= { optIfOMSnConfigEntry 2 }
 | 
						|
 | 
						|
-- OMSn sink current table
 | 
						|
-- Contains data for the current 15-minute performance monitoring
 | 
						|
-- interval.
 | 
						|
 | 
						|
optIfOMSnSinkCurrentTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfOMSnSinkCurrentEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of OMSn sink performance monitoring information for
 | 
						|
     the current 15-minute interval."
 | 
						|
  ::= { optIfOMSn 2 }
 | 
						|
 | 
						|
optIfOMSnSinkCurrentEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfOMSnSinkCurrentEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains OMSn sink performance
 | 
						|
     monitoring information of an interface for the current
 | 
						|
     15-minute interval."
 | 
						|
  INDEX  { ifIndex }
 | 
						|
  ::= { optIfOMSnSinkCurrentTable 1 }
 | 
						|
 | 
						|
OptIfOMSnSinkCurrentEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfOMSnSinkCurrentSuspectedFlag              TruthValue,
 | 
						|
    optIfOMSnSinkCurrentAggregatedInputPower       Integer32,
 | 
						|
    optIfOMSnSinkCurrentLowAggregatedInputPower    Integer32,
 | 
						|
    optIfOMSnSinkCurrentHighAggregatedInputPower   Integer32,
 | 
						|
    optIfOMSnSinkCurrentLowerInputPowerThreshold   Integer32,
 | 
						|
    optIfOMSnSinkCurrentUpperInputPowerThreshold   Integer32,
 | 
						|
    optIfOMSnSinkCurrentOutputPower                Integer32,
 | 
						|
    optIfOMSnSinkCurrentLowOutputPower             Integer32,
 | 
						|
    optIfOMSnSinkCurrentHighOutputPower            Integer32,
 | 
						|
    optIfOMSnSinkCurrentLowerOutputPowerThreshold  Integer32,
 | 
						|
    optIfOMSnSinkCurrentUpperOutputPowerThreshold  Integer32
 | 
						|
    }
 | 
						|
 | 
						|
optIfOMSnSinkCurrentSuspectedFlag OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
 | 
						|
 | 
						|
    "If true, the data in this entry may be unreliable."
 | 
						|
  ::= { optIfOMSnSinkCurrentEntry 1 }
 | 
						|
 | 
						|
optIfOMSnSinkCurrentAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The aggregated optical power of all the DWDM input
 | 
						|
     channels."
 | 
						|
  ::= { optIfOMSnSinkCurrentEntry 2 }
 | 
						|
 | 
						|
optIfOMSnSinkCurrentLowAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest aggregated optical power of all the DWDM input
 | 
						|
     channels during the current 15-minute interval."
 | 
						|
  ::= { optIfOMSnSinkCurrentEntry 3 }
 | 
						|
 | 
						|
optIfOMSnSinkCurrentHighAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest aggregated optical power of all the DWDM input
 | 
						|
     channels during the current 15-minute interval."
 | 
						|
  ::= { optIfOMSnSinkCurrentEntry 4 }
 | 
						|
 | 
						|
optIfOMSnSinkCurrentLowerInputPowerThreshold OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lower limit threshold on aggregated input power.  If
 | 
						|
     optIfOMSnSinkCurrentAggregatedInputPower drops to this value
 | 
						|
     or below, a Threshold Crossing Alert (TCA) should be sent."
 | 
						|
  ::= { optIfOMSnSinkCurrentEntry 5 }
 | 
						|
 | 
						|
optIfOMSnSinkCurrentUpperInputPowerThreshold OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
 | 
						|
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The upper limit threshold on aggregated input power.  If
 | 
						|
     optIfOMSnSinkCurrentAggregatedInputPower reaches or exceeds
 | 
						|
     this value, a Threshold Crossing Alert (TCA) should be sent."
 | 
						|
  ::= { optIfOMSnSinkCurrentEntry 6 }
 | 
						|
 | 
						|
optIfOMSnSinkCurrentOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The optical power monitored at the output."
 | 
						|
  ::= { optIfOMSnSinkCurrentEntry 7 }
 | 
						|
 | 
						|
optIfOMSnSinkCurrentLowOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest optical power monitored at the output
 | 
						|
     during the current 15-minute interval."
 | 
						|
  ::= { optIfOMSnSinkCurrentEntry 8 }
 | 
						|
 | 
						|
optIfOMSnSinkCurrentHighOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest optical power monitored at the output
 | 
						|
     during the current 15-minute interval."
 | 
						|
  ::= { optIfOMSnSinkCurrentEntry 9 }
 | 
						|
 | 
						|
optIfOMSnSinkCurrentLowerOutputPowerThreshold OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lower limit threshold on output power.  If
 | 
						|
     optIfOMSnSinkCurrentOutputPower drops to this value
 | 
						|
     or below, a Threshold Crossing Alert (TCA) should be sent."
 | 
						|
  ::= { optIfOMSnSinkCurrentEntry 10 }
 | 
						|
 | 
						|
optIfOMSnSinkCurrentUpperOutputPowerThreshold OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The upper limit threshold on output power.  If
 | 
						|
     optIfOMSnSinkCurrentOutputPower reaches or exceeds
 | 
						|
     this value, a Threshold Crossing Alert (TCA) should be sent."
 | 
						|
  ::= { optIfOMSnSinkCurrentEntry 11 }
 | 
						|
 | 
						|
-- OMSn sink interval table
 | 
						|
-- Contains data for previous 15-minute performance monitoring
 | 
						|
-- intervals.
 | 
						|
 | 
						|
optIfOMSnSinkIntervalTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfOMSnSinkIntervalEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of historical OMSn sink performance monitoring
 | 
						|
     information."
 | 
						|
  ::= { optIfOMSn 3 }
 | 
						|
 | 
						|
optIfOMSnSinkIntervalEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfOMSnSinkIntervalEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains OMSn sink performance
 | 
						|
     monitoring information of an interface during a particular
 | 
						|
     historical interval."
 | 
						|
  INDEX  { ifIndex, optIfOMSnSinkIntervalNumber }
 | 
						|
  ::= { optIfOMSnSinkIntervalTable 1 }
 | 
						|
 | 
						|
OptIfOMSnSinkIntervalEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfOMSnSinkIntervalNumber                    OptIfIntervalNumber,
 | 
						|
    optIfOMSnSinkIntervalSuspectedFlag             TruthValue,
 | 
						|
    optIfOMSnSinkIntervalLastAggregatedInputPower  Integer32,
 | 
						|
    optIfOMSnSinkIntervalLowAggregatedInputPower   Integer32,
 | 
						|
    optIfOMSnSinkIntervalHighAggregatedInputPower  Integer32,
 | 
						|
    optIfOMSnSinkIntervalLastOutputPower           Integer32,
 | 
						|
    optIfOMSnSinkIntervalLowOutputPower            Integer32,
 | 
						|
    optIfOMSnSinkIntervalHighOutputPower           Integer32
 | 
						|
    }
 | 
						|
 | 
						|
optIfOMSnSinkIntervalNumber OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfIntervalNumber
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Uniquely identifies the interval."
 | 
						|
  ::= { optIfOMSnSinkIntervalEntry 1 }
 | 
						|
 | 
						|
optIfOMSnSinkIntervalSuspectedFlag OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "If true, the data in this entry may be unreliable."
 | 
						|
  ::= { optIfOMSnSinkIntervalEntry 2 }
 | 
						|
 | 
						|
optIfOMSnSinkIntervalLastAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The last aggregated optical power of all the DWDM input
 | 
						|
     channels during the interval."
 | 
						|
  ::= { optIfOMSnSinkIntervalEntry 3 }
 | 
						|
 | 
						|
optIfOMSnSinkIntervalLowAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest aggregated optical power of all the DWDM input
 | 
						|
     channels during the interval."
 | 
						|
  ::= { optIfOMSnSinkIntervalEntry 4 }
 | 
						|
 | 
						|
optIfOMSnSinkIntervalHighAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest aggregated optical power of all the DWDM input
 | 
						|
     channels during the interval."
 | 
						|
  ::= { optIfOMSnSinkIntervalEntry 5 }
 | 
						|
 | 
						|
optIfOMSnSinkIntervalLastOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The last optical power at the output
 | 
						|
     during the interval."
 | 
						|
  ::= { optIfOMSnSinkIntervalEntry 6 }
 | 
						|
 | 
						|
optIfOMSnSinkIntervalLowOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest optical power at the output
 | 
						|
     during the interval."
 | 
						|
  ::= { optIfOMSnSinkIntervalEntry 7 }
 | 
						|
 | 
						|
optIfOMSnSinkIntervalHighOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest optical power at the output
 | 
						|
     during the interval."
 | 
						|
  ::= { optIfOMSnSinkIntervalEntry 8 }
 | 
						|
 | 
						|
-- OMSn sink current day table
 | 
						|
-- Contains data for the current 24-hour performance
 | 
						|
-- monitoring interval.
 | 
						|
 | 
						|
optIfOMSnSinkCurDayTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfOMSnSinkCurDayEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of OMSn sink performance monitoring information for
 | 
						|
     the current 24-hour interval."
 | 
						|
  ::= { optIfOMSn 4 }
 | 
						|
 | 
						|
optIfOMSnSinkCurDayEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfOMSnSinkCurDayEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains OMSn sink performance
 | 
						|
     monitoring information of an interface for the current
 | 
						|
     24-hour interval."
 | 
						|
  INDEX  { ifIndex }
 | 
						|
  ::= { optIfOMSnSinkCurDayTable 1 }
 | 
						|
 | 
						|
OptIfOMSnSinkCurDayEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfOMSnSinkCurDaySuspectedFlag             TruthValue,
 | 
						|
    optIfOMSnSinkCurDayLowAggregatedInputPower   Integer32,
 | 
						|
    optIfOMSnSinkCurDayHighAggregatedInputPower  Integer32,
 | 
						|
    optIfOMSnSinkCurDayLowOutputPower            Integer32,
 | 
						|
    optIfOMSnSinkCurDayHighOutputPower           Integer32
 | 
						|
    }
 | 
						|
 | 
						|
optIfOMSnSinkCurDaySuspectedFlag OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "If true, the data in this entry may be unreliable."
 | 
						|
  ::= { optIfOMSnSinkCurDayEntry 1 }
 | 
						|
 | 
						|
optIfOMSnSinkCurDayLowAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest aggregated optical power of all the DWDM input
 | 
						|
     channels during the current 24-hour interval."
 | 
						|
  ::= { optIfOMSnSinkCurDayEntry 2 }
 | 
						|
 | 
						|
optIfOMSnSinkCurDayHighAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest aggregated optical power of all the DWDM input
 | 
						|
     channels during the current 24-hour interval."
 | 
						|
  ::= { optIfOMSnSinkCurDayEntry 3 }
 | 
						|
 | 
						|
optIfOMSnSinkCurDayLowOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest optical power at the output
 | 
						|
     during the current 24-hour interval."
 | 
						|
  ::= { optIfOMSnSinkCurDayEntry 4 }
 | 
						|
 | 
						|
optIfOMSnSinkCurDayHighOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest  optical power at the output
 | 
						|
     during the current 24-hour interval."
 | 
						|
  ::= { optIfOMSnSinkCurDayEntry 5 }
 | 
						|
 | 
						|
-- OMSn sink previous day table
 | 
						|
-- Contains data for the previous 24-hour performance
 | 
						|
-- monitoring interval.
 | 
						|
 | 
						|
optIfOMSnSinkPrevDayTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfOMSnSinkPrevDayEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of OMSn sink performance monitoring information for
 | 
						|
     the previous 24-hour interval."
 | 
						|
  ::= { optIfOMSn 5 }
 | 
						|
 | 
						|
optIfOMSnSinkPrevDayEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfOMSnSinkPrevDayEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains OMSn sink performance
 | 
						|
     monitoring information of an interface for the previous
 | 
						|
     24-hour interval."
 | 
						|
  INDEX  { ifIndex }
 | 
						|
  ::= { optIfOMSnSinkPrevDayTable 1 }
 | 
						|
 | 
						|
OptIfOMSnSinkPrevDayEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfOMSnSinkPrevDaySuspectedFlag             TruthValue,
 | 
						|
    optIfOMSnSinkPrevDayLastAggregatedInputPower  Integer32,
 | 
						|
    optIfOMSnSinkPrevDayLowAggregatedInputPower   Integer32,
 | 
						|
    optIfOMSnSinkPrevDayHighAggregatedInputPower  Integer32,
 | 
						|
    optIfOMSnSinkPrevDayLastOutputPower           Integer32,
 | 
						|
    optIfOMSnSinkPrevDayLowOutputPower            Integer32,
 | 
						|
    optIfOMSnSinkPrevDayHighOutputPower           Integer32
 | 
						|
    }
 | 
						|
 | 
						|
optIfOMSnSinkPrevDaySuspectedFlag OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "If true, the data in this entry may be unreliable."
 | 
						|
  ::= { optIfOMSnSinkPrevDayEntry 1 }
 | 
						|
 | 
						|
optIfOMSnSinkPrevDayLastAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The last aggregated optical power of all the DWDM input
 | 
						|
     channels during the previous 24-hour interval."
 | 
						|
  ::= { optIfOMSnSinkPrevDayEntry 2 }
 | 
						|
 | 
						|
optIfOMSnSinkPrevDayLowAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest aggregated optical power of all the DWDM input
 | 
						|
     channels during the previous 24-hour interval."
 | 
						|
  ::= { optIfOMSnSinkPrevDayEntry 3 }
 | 
						|
 | 
						|
optIfOMSnSinkPrevDayHighAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest aggregated optical power of all the DWDM input
 | 
						|
     channels during the previous 24-hour interval."
 | 
						|
  ::= { optIfOMSnSinkPrevDayEntry 4 }
 | 
						|
 | 
						|
optIfOMSnSinkPrevDayLastOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The last  optical power at the output
 | 
						|
     during the previous 24-hour interval."
 | 
						|
  ::= { optIfOMSnSinkPrevDayEntry 5 }
 | 
						|
 | 
						|
optIfOMSnSinkPrevDayLowOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest optical power at the output
 | 
						|
     during the previous 24-hour interval."
 | 
						|
  ::= { optIfOMSnSinkPrevDayEntry 6 }
 | 
						|
 | 
						|
optIfOMSnSinkPrevDayHighOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest optical power at the output
 | 
						|
     during the previous 24-hour interval."
 | 
						|
  ::= { optIfOMSnSinkPrevDayEntry 7 }
 | 
						|
 | 
						|
-- OMSn source current table
 | 
						|
-- Contains data for the current 15-minute performance monitoring
 | 
						|
-- interval.
 | 
						|
 | 
						|
optIfOMSnSrcCurrentTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfOMSnSrcCurrentEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of OMSn source performance monitoring information for
 | 
						|
     the current 15-minute interval."
 | 
						|
  ::= { optIfOMSn 6 }
 | 
						|
 | 
						|
optIfOMSnSrcCurrentEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfOMSnSrcCurrentEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains OMSn source performance
 | 
						|
     monitoring information of an interface for the current
 | 
						|
     15-minute interval."
 | 
						|
  INDEX  { ifIndex }
 | 
						|
  ::= { optIfOMSnSrcCurrentTable 1 }
 | 
						|
 | 
						|
OptIfOMSnSrcCurrentEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfOMSnSrcCurrentSuspectedFlag              TruthValue,
 | 
						|
    optIfOMSnSrcCurrentOutputPower                Integer32,
 | 
						|
    optIfOMSnSrcCurrentLowOutputPower             Integer32,
 | 
						|
    optIfOMSnSrcCurrentHighOutputPower            Integer32,
 | 
						|
    optIfOMSnSrcCurrentLowerOutputPowerThreshold  Integer32,
 | 
						|
    optIfOMSnSrcCurrentUpperOutputPowerThreshold  Integer32,
 | 
						|
    optIfOMSnSrcCurrentAggregatedInputPower       Integer32,
 | 
						|
    optIfOMSnSrcCurrentLowAggregatedInputPower    Integer32,
 | 
						|
    optIfOMSnSrcCurrentHighAggregatedInputPower   Integer32,
 | 
						|
    optIfOMSnSrcCurrentLowerInputPowerThreshold   Integer32,
 | 
						|
    optIfOMSnSrcCurrentUpperInputPowerThreshold   Integer32
 | 
						|
    }
 | 
						|
 | 
						|
optIfOMSnSrcCurrentSuspectedFlag OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "If true, the data in this entry may be unreliable."
 | 
						|
  ::= { optIfOMSnSrcCurrentEntry 1 }
 | 
						|
 | 
						|
optIfOMSnSrcCurrentOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The optical power monitored at the output."
 | 
						|
  ::= { optIfOMSnSrcCurrentEntry 2 }
 | 
						|
 | 
						|
optIfOMSnSrcCurrentLowOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest optical power monitored at the output during the
 | 
						|
     current 15-minute interval."
 | 
						|
  ::= { optIfOMSnSrcCurrentEntry 3 }
 | 
						|
 | 
						|
optIfOMSnSrcCurrentHighOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest optical power monitored at the output during the
 | 
						|
     current 15-minute interval."
 | 
						|
  ::= { optIfOMSnSrcCurrentEntry 4 }
 | 
						|
 | 
						|
optIfOMSnSrcCurrentLowerOutputPowerThreshold OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lower limit threshold on output power.  If
 | 
						|
     optIfOMSnSrcCurrentOutputPower drops to this value or below,
 | 
						|
     a Threshold Crossing Alert (TCA) should be sent."
 | 
						|
  ::= { optIfOMSnSrcCurrentEntry 5 }
 | 
						|
 | 
						|
optIfOMSnSrcCurrentUpperOutputPowerThreshold OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The upper limit threshold on output power.  If
 | 
						|
     optIfOMSnSrcCurrentOutputPower reaches or exceeds this value,
 | 
						|
     a Threshold Crossing Alert (TCA) should be sent."
 | 
						|
  ::= { optIfOMSnSrcCurrentEntry 6 }
 | 
						|
 | 
						|
optIfOMSnSrcCurrentAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The aggregated optical power at the input."
 | 
						|
  ::= { optIfOMSnSrcCurrentEntry 7 }
 | 
						|
 | 
						|
optIfOMSnSrcCurrentLowAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest aggregated optical power at the input
 | 
						|
     during the current 15-minute interval."
 | 
						|
  ::= { optIfOMSnSrcCurrentEntry 8 }
 | 
						|
 | 
						|
optIfOMSnSrcCurrentHighAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest aggregated optical power at the input
 | 
						|
     during the current 15-minute interval."
 | 
						|
  ::= { optIfOMSnSrcCurrentEntry 9 }
 | 
						|
 | 
						|
 | 
						|
optIfOMSnSrcCurrentLowerInputPowerThreshold OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lower limit threshold on aggregated input power.  If
 | 
						|
     optIfOMSnSrcCurrentAggregatedInputPower drops to this value
 | 
						|
     or below, a Threshold Crossing Alert (TCA) should be sent."
 | 
						|
  ::= { optIfOMSnSrcCurrentEntry 10 }
 | 
						|
 | 
						|
optIfOMSnSrcCurrentUpperInputPowerThreshold OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The upper limit threshold on aggregated input power.  If
 | 
						|
     optIfOMSnSrcCurrentAggregatedInputPower reaches or exceeds
 | 
						|
     this value, a Threshold Crossing Alert (TCA) should be sent."
 | 
						|
  ::= { optIfOMSnSrcCurrentEntry 11 }
 | 
						|
 | 
						|
 | 
						|
-- OMSn source interval table
 | 
						|
-- Contains data for previous 15-minute performance monitoring
 | 
						|
-- intervals.
 | 
						|
 | 
						|
optIfOMSnSrcIntervalTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfOMSnSrcIntervalEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of historical OMSn source performance monitoring
 | 
						|
     information."
 | 
						|
  ::= { optIfOMSn 7 }
 | 
						|
 | 
						|
optIfOMSnSrcIntervalEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfOMSnSrcIntervalEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains OMSn source performance
 | 
						|
     monitoring information of an interface during a particular
 | 
						|
     historical interval."
 | 
						|
  INDEX  { ifIndex, optIfOMSnSrcIntervalNumber }
 | 
						|
  ::= { optIfOMSnSrcIntervalTable 1 }
 | 
						|
 | 
						|
OptIfOMSnSrcIntervalEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfOMSnSrcIntervalNumber                    OptIfIntervalNumber,
 | 
						|
    optIfOMSnSrcIntervalSuspectedFlag             TruthValue,
 | 
						|
    optIfOMSnSrcIntervalLastOutputPower           Integer32,
 | 
						|
    optIfOMSnSrcIntervalLowOutputPower            Integer32,
 | 
						|
    optIfOMSnSrcIntervalHighOutputPower           Integer32,
 | 
						|
    optIfOMSnSrcIntervalLastAggregatedInputPower  Integer32,
 | 
						|
    optIfOMSnSrcIntervalLowAggregatedInputPower   Integer32,
 | 
						|
    optIfOMSnSrcIntervalHighAggregatedInputPower  Integer32
 | 
						|
    }
 | 
						|
 | 
						|
optIfOMSnSrcIntervalNumber OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfIntervalNumber
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Uniquely identifies the interval."
 | 
						|
  ::= { optIfOMSnSrcIntervalEntry 1 }
 | 
						|
 | 
						|
optIfOMSnSrcIntervalSuspectedFlag OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "If true, the data in this entry may be unreliable."
 | 
						|
  ::= { optIfOMSnSrcIntervalEntry 2 }
 | 
						|
 | 
						|
optIfOMSnSrcIntervalLastOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The last optical power monitored at the output during the
 | 
						|
     interval."
 | 
						|
  ::= { optIfOMSnSrcIntervalEntry 3 }
 | 
						|
 | 
						|
optIfOMSnSrcIntervalLowOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest optical power monitored at the output during the
 | 
						|
     interval."
 | 
						|
  ::= { optIfOMSnSrcIntervalEntry 4 }
 | 
						|
 | 
						|
optIfOMSnSrcIntervalHighOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest optical power monitored at the output during the
 | 
						|
     interval."
 | 
						|
  ::= { optIfOMSnSrcIntervalEntry 5 }
 | 
						|
 | 
						|
optIfOMSnSrcIntervalLastAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The last aggregated optical power at the input
 | 
						|
     during the interval."
 | 
						|
  ::= { optIfOMSnSrcIntervalEntry 6 }
 | 
						|
 | 
						|
optIfOMSnSrcIntervalLowAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest aggregated optical power at the input
 | 
						|
     during the interval."
 | 
						|
  ::= { optIfOMSnSrcIntervalEntry 7 }
 | 
						|
 | 
						|
optIfOMSnSrcIntervalHighAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest aggregated optical power at the input
 | 
						|
     during the interval."
 | 
						|
  ::= { optIfOMSnSrcIntervalEntry 8 }
 | 
						|
 | 
						|
-- OMSn source current day table
 | 
						|
-- Contains data for the current 24-hour performance
 | 
						|
-- monitoring interval.
 | 
						|
 | 
						|
optIfOMSnSrcCurDayTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfOMSnSrcCurDayEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of OMSn source performance monitoring information for
 | 
						|
     the current 24-hour interval."
 | 
						|
  ::= { optIfOMSn 8 }
 | 
						|
 | 
						|
optIfOMSnSrcCurDayEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfOMSnSrcCurDayEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains OMSn source performance
 | 
						|
     monitoring information of an interface for the current
 | 
						|
     24-hour interval."
 | 
						|
  INDEX  { ifIndex }
 | 
						|
  ::= { optIfOMSnSrcCurDayTable 1 }
 | 
						|
 | 
						|
OptIfOMSnSrcCurDayEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfOMSnSrcCurDaySuspectedFlag             TruthValue,
 | 
						|
    optIfOMSnSrcCurDayLowOutputPower            Integer32,
 | 
						|
    optIfOMSnSrcCurDayHighOutputPower           Integer32,
 | 
						|
    optIfOMSnSrcCurDayLowAggregatedInputPower   Integer32,
 | 
						|
    optIfOMSnSrcCurDayHighAggregatedInputPower  Integer32
 | 
						|
    }
 | 
						|
 | 
						|
optIfOMSnSrcCurDaySuspectedFlag OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "If true, the data in this entry may be unreliable."
 | 
						|
  ::= { optIfOMSnSrcCurDayEntry 1 }
 | 
						|
 | 
						|
optIfOMSnSrcCurDayLowOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest optical power monitored at the output during the
 | 
						|
     current 24-hour interval."
 | 
						|
  ::= { optIfOMSnSrcCurDayEntry 2 }
 | 
						|
 | 
						|
optIfOMSnSrcCurDayHighOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest optical power monitored at the output during the
 | 
						|
     current 24-hour interval."
 | 
						|
  ::= { optIfOMSnSrcCurDayEntry 3 }
 | 
						|
 | 
						|
optIfOMSnSrcCurDayLowAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest aggregated optical power at the input
 | 
						|
     during the current 24-hour interval."
 | 
						|
  ::= { optIfOMSnSrcCurDayEntry 4 }
 | 
						|
 | 
						|
optIfOMSnSrcCurDayHighAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest aggregated optical power at the input
 | 
						|
     during the current 24-hour interval."
 | 
						|
  ::= { optIfOMSnSrcCurDayEntry 5 }
 | 
						|
 | 
						|
-- OMSn source previous day table
 | 
						|
-- Contains data for the previous 24-hour performance
 | 
						|
-- monitoring interval.
 | 
						|
 | 
						|
optIfOMSnSrcPrevDayTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfOMSnSrcPrevDayEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of OMSn source performance monitoring information for
 | 
						|
     the previous 24-hour interval."
 | 
						|
  ::= { optIfOMSn 9 }
 | 
						|
 | 
						|
optIfOMSnSrcPrevDayEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfOMSnSrcPrevDayEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains OMSn source performance
 | 
						|
     monitoring information of an interface for the previous
 | 
						|
     24-hour interval."
 | 
						|
  INDEX  { ifIndex }
 | 
						|
  ::= { optIfOMSnSrcPrevDayTable 1 }
 | 
						|
 | 
						|
 | 
						|
OptIfOMSnSrcPrevDayEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfOMSnSrcPrevDaySuspectedFlag             TruthValue,
 | 
						|
    optIfOMSnSrcPrevDayLastOutputPower           Integer32,
 | 
						|
    optIfOMSnSrcPrevDayLowOutputPower            Integer32,
 | 
						|
    optIfOMSnSrcPrevDayHighOutputPower           Integer32,
 | 
						|
    optIfOMSnSrcPrevDayLastAggregatedInputPower  Integer32,
 | 
						|
    optIfOMSnSrcPrevDayLowAggregatedInputPower   Integer32,
 | 
						|
    optIfOMSnSrcPrevDayHighAggregatedInputPower  Integer32
 | 
						|
    }
 | 
						|
 | 
						|
optIfOMSnSrcPrevDaySuspectedFlag OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "If true, the data in this entry may be unreliable."
 | 
						|
  ::= { optIfOMSnSrcPrevDayEntry 1 }
 | 
						|
 | 
						|
optIfOMSnSrcPrevDayLastOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The last optical power monitored at the output during the
 | 
						|
     previous 24-hour interval."
 | 
						|
  ::= { optIfOMSnSrcPrevDayEntry 2 }
 | 
						|
 | 
						|
optIfOMSnSrcPrevDayLowOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest optical power monitored at the output during the
 | 
						|
     previous 24-hour interval."
 | 
						|
  ::= { optIfOMSnSrcPrevDayEntry 3 }
 | 
						|
 | 
						|
optIfOMSnSrcPrevDayHighOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest optical power monitored at the output during the
 | 
						|
     previous 24-hour interval."
 | 
						|
  ::= { optIfOMSnSrcPrevDayEntry 4 }
 | 
						|
 | 
						|
optIfOMSnSrcPrevDayLastAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The last aggregated optical power at the input during the
 | 
						|
     previous 24-hour interval."
 | 
						|
  ::= { optIfOMSnSrcPrevDayEntry 5 }
 | 
						|
 | 
						|
optIfOMSnSrcPrevDayLowAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest aggregated optical power at the input during the
 | 
						|
     previous 24-hour interval."
 | 
						|
  ::= { optIfOMSnSrcPrevDayEntry 6 }
 | 
						|
 | 
						|
optIfOMSnSrcPrevDayHighAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest aggregated optical power at the input during the
 | 
						|
     previous 24-hour interval."
 | 
						|
  ::= { optIfOMSnSrcPrevDayEntry 7 }
 | 
						|
 | 
						|
-- the optIfOChGroup group
 | 
						|
-- This group handles the configuration and performance monitoring
 | 
						|
-- information for OChGroup layers.
 | 
						|
 | 
						|
-- OChGroup config table
 | 
						|
 | 
						|
optIfOChGroupConfigTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfOChGroupConfigEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of OChGroup configuration information."
 | 
						|
  ::= { optIfOChGroup 1 }
 | 
						|
 | 
						|
optIfOChGroupConfigEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfOChGroupConfigEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains OChGroup configuration
 | 
						|
     information of an interface."
 | 
						|
  INDEX  { ifIndex }
 | 
						|
  ::= { optIfOChGroupConfigTable 1 }
 | 
						|
 | 
						|
OptIfOChGroupConfigEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfOChGroupDirectionality OptIfDirectionality
 | 
						|
    }
 | 
						|
 | 
						|
optIfOChGroupDirectionality OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfDirectionality
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the directionality of the entity."
 | 
						|
  ::= { optIfOChGroupConfigEntry 1 }
 | 
						|
 | 
						|
-- OChGroup sink current table
 | 
						|
-- Contains data for the current 15-minute performance monitoring
 | 
						|
-- interval.
 | 
						|
 | 
						|
optIfOChGroupSinkCurrentTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfOChGroupSinkCurrentEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of OChGroup sink performance monitoring information for
 | 
						|
     the current 15-minute interval."
 | 
						|
  ::= { optIfOChGroup 2 }
 | 
						|
 | 
						|
optIfOChGroupSinkCurrentEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfOChGroupSinkCurrentEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains OChGroup sink performance
 | 
						|
     monitoring information of an interface for the current
 | 
						|
     15-minute interval."
 | 
						|
  INDEX  { ifIndex }
 | 
						|
  ::= { optIfOChGroupSinkCurrentTable 1 }
 | 
						|
 | 
						|
OptIfOChGroupSinkCurrentEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfOChGroupSinkCurrentSuspectedFlag              TruthValue,
 | 
						|
    optIfOChGroupSinkCurrentAggregatedInputPower       Integer32,
 | 
						|
    optIfOChGroupSinkCurrentLowAggregatedInputPower    Integer32,
 | 
						|
    optIfOChGroupSinkCurrentHighAggregatedInputPower   Integer32,
 | 
						|
    optIfOChGroupSinkCurrentLowerInputPowerThreshold   Integer32,
 | 
						|
    optIfOChGroupSinkCurrentUpperInputPowerThreshold   Integer32,
 | 
						|
    optIfOChGroupSinkCurrentOutputPower                Integer32,
 | 
						|
    optIfOChGroupSinkCurrentLowOutputPower             Integer32,
 | 
						|
    optIfOChGroupSinkCurrentHighOutputPower            Integer32,
 | 
						|
    optIfOChGroupSinkCurrentLowerOutputPowerThreshold  Integer32,
 | 
						|
    optIfOChGroupSinkCurrentUpperOutputPowerThreshold  Integer32
 | 
						|
    }
 | 
						|
 | 
						|
optIfOChGroupSinkCurrentSuspectedFlag OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "If true, the data in this entry may be unreliable."
 | 
						|
  ::= { optIfOChGroupSinkCurrentEntry 1 }
 | 
						|
 | 
						|
optIfOChGroupSinkCurrentAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The aggregated optical power of all the DWDM input
 | 
						|
     channels in the OChGroup."
 | 
						|
  ::= { optIfOChGroupSinkCurrentEntry 2 }
 | 
						|
 | 
						|
optIfOChGroupSinkCurrentLowAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest aggregated optical power of all the DWDM input
 | 
						|
     channels in the OChGroup during the current 15-minute interval."
 | 
						|
  ::= { optIfOChGroupSinkCurrentEntry 3 }
 | 
						|
 | 
						|
optIfOChGroupSinkCurrentHighAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest aggregated optical power of all the DWDM input
 | 
						|
     channels in the OChGroup during the current 15-minute interval."
 | 
						|
  ::= { optIfOChGroupSinkCurrentEntry 4 }
 | 
						|
 | 
						|
 | 
						|
optIfOChGroupSinkCurrentLowerInputPowerThreshold OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lower limit threshold on aggregated input power.  If
 | 
						|
     optIfOChGroupSinkCurrentAggregatedInputPower drops to this value
 | 
						|
     or below, a Threshold Crossing Alert (TCA) should be sent."
 | 
						|
  ::= { optIfOChGroupSinkCurrentEntry 5 }
 | 
						|
 | 
						|
optIfOChGroupSinkCurrentUpperInputPowerThreshold OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The upper limit threshold on aggregated input power.  If
 | 
						|
     optIfOChGroupSinkCurrentAggregatedInputPower reaches or exceeds
 | 
						|
     this value, a Threshold Crossing Alert (TCA) should be sent."
 | 
						|
  ::= { optIfOChGroupSinkCurrentEntry 6 }
 | 
						|
 | 
						|
optIfOChGroupSinkCurrentOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The optical power monitored at the output
 | 
						|
     in the OChGroup."
 | 
						|
  ::= { optIfOChGroupSinkCurrentEntry 7 }
 | 
						|
 | 
						|
optIfOChGroupSinkCurrentLowOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest optical power monitored at the output
 | 
						|
     in the OChGroup during the current 15-minute interval."
 | 
						|
  ::= { optIfOChGroupSinkCurrentEntry 8 }
 | 
						|
 | 
						|
optIfOChGroupSinkCurrentHighOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest optical power monitored at the output
 | 
						|
     in the OChGroup during the current 15-minute interval."
 | 
						|
  ::= { optIfOChGroupSinkCurrentEntry 9 }
 | 
						|
 | 
						|
optIfOChGroupSinkCurrentLowerOutputPowerThreshold OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lower limit threshold on the output power.  If
 | 
						|
     optIfOChGroupSinkCurrentOutputPower drops to this value
 | 
						|
     or below, a Threshold Crossing Alert (TCA) should be sent."
 | 
						|
  ::= { optIfOChGroupSinkCurrentEntry 10 }
 | 
						|
 | 
						|
optIfOChGroupSinkCurrentUpperOutputPowerThreshold OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The upper limit threshold on the output power.  If
 | 
						|
     optIfOChGroupSinkCurrentOutputPower reaches or exceeds
 | 
						|
     this value, a Threshold Crossing Alert (TCA) should be sent."
 | 
						|
  ::= { optIfOChGroupSinkCurrentEntry 11 }
 | 
						|
 | 
						|
-- OChGroup sink interval table
 | 
						|
-- Contains data for previous 15-minute performance monitoring
 | 
						|
-- intervals.
 | 
						|
 | 
						|
optIfOChGroupSinkIntervalTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfOChGroupSinkIntervalEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of historical OChGroup sink performance monitoring
 | 
						|
     information."
 | 
						|
  ::= { optIfOChGroup 3 }
 | 
						|
 | 
						|
optIfOChGroupSinkIntervalEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfOChGroupSinkIntervalEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains OChGroup sink performance
 | 
						|
     monitoring information of an interface during a particular
 | 
						|
     historical interval."
 | 
						|
  INDEX  { ifIndex, optIfOChGroupSinkIntervalNumber }
 | 
						|
  ::= { optIfOChGroupSinkIntervalTable 1 }
 | 
						|
 | 
						|
OptIfOChGroupSinkIntervalEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
   optIfOChGroupSinkIntervalNumber                  OptIfIntervalNumber,
 | 
						|
   optIfOChGroupSinkIntervalSuspectedFlag            TruthValue,
 | 
						|
   optIfOChGroupSinkIntervalLastAggregatedInputPower Integer32,
 | 
						|
   optIfOChGroupSinkIntervalLowAggregatedInputPower  Integer32,
 | 
						|
   optIfOChGroupSinkIntervalHighAggregatedInputPower Integer32,
 | 
						|
   optIfOChGroupSinkIntervalLastOutputPower          Integer32,
 | 
						|
   optIfOChGroupSinkIntervalLowOutputPower           Integer32,
 | 
						|
   optIfOChGroupSinkIntervalHighOutputPower          Integer32
 | 
						|
   }
 | 
						|
 | 
						|
optIfOChGroupSinkIntervalNumber OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfIntervalNumber
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Uniquely identifies the interval."
 | 
						|
  ::= { optIfOChGroupSinkIntervalEntry 1 }
 | 
						|
 | 
						|
optIfOChGroupSinkIntervalSuspectedFlag OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "If true, the data in this entry may be unreliable."
 | 
						|
  ::= { optIfOChGroupSinkIntervalEntry 2 }
 | 
						|
 | 
						|
optIfOChGroupSinkIntervalLastAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The last aggregated optical power of all the DWDM input
 | 
						|
     channels in the OChGroup during the interval."
 | 
						|
  ::= { optIfOChGroupSinkIntervalEntry 3 }
 | 
						|
 | 
						|
optIfOChGroupSinkIntervalLowAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest aggregated optical power of all the DWDM input
 | 
						|
     channels in the OChGroup during the interval."
 | 
						|
  ::= { optIfOChGroupSinkIntervalEntry 4 }
 | 
						|
 | 
						|
optIfOChGroupSinkIntervalHighAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest aggregated optical power of all the DWDM input
 | 
						|
     channels in the OChGroup during the interval."
 | 
						|
  ::= { optIfOChGroupSinkIntervalEntry 5 }
 | 
						|
 | 
						|
optIfOChGroupSinkIntervalLastOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The last optical power monitored at the output
 | 
						|
     in the OChGroup during the interval."
 | 
						|
  ::= { optIfOChGroupSinkIntervalEntry 6 }
 | 
						|
 | 
						|
optIfOChGroupSinkIntervalLowOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest optical power monitored at the output
 | 
						|
     in the OChGroup during the interval."
 | 
						|
  ::= { optIfOChGroupSinkIntervalEntry 7 }
 | 
						|
 | 
						|
optIfOChGroupSinkIntervalHighOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest optical power monitored at the output
 | 
						|
     in the OChGroup during the interval."
 | 
						|
  ::= { optIfOChGroupSinkIntervalEntry 8 }
 | 
						|
 | 
						|
-- OChGroup sink current day table
 | 
						|
-- Contains data for the current 24-hour performance
 | 
						|
-- monitoring interval.
 | 
						|
 | 
						|
optIfOChGroupSinkCurDayTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfOChGroupSinkCurDayEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of OChGroup sink performance monitoring information for
 | 
						|
     the current 24-hour interval."
 | 
						|
  ::= { optIfOChGroup 4 }
 | 
						|
 | 
						|
optIfOChGroupSinkCurDayEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfOChGroupSinkCurDayEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains OChGroup sink performance
 | 
						|
     monitoring information of an interface for the current
 | 
						|
     24-hour interval."
 | 
						|
  INDEX  { ifIndex }
 | 
						|
  ::= { optIfOChGroupSinkCurDayTable 1 }
 | 
						|
 | 
						|
OptIfOChGroupSinkCurDayEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfOChGroupSinkCurDaySuspectedFlag             TruthValue,
 | 
						|
    optIfOChGroupSinkCurDayLowAggregatedInputPower   Integer32,
 | 
						|
    optIfOChGroupSinkCurDayHighAggregatedInputPower  Integer32,
 | 
						|
    optIfOChGroupSinkCurDayLowOutputPower            Integer32,
 | 
						|
    optIfOChGroupSinkCurDayHighOutputPower           Integer32
 | 
						|
    }
 | 
						|
 | 
						|
optIfOChGroupSinkCurDaySuspectedFlag OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "If true, the data in this entry may be unreliable."
 | 
						|
  ::= { optIfOChGroupSinkCurDayEntry 1 }
 | 
						|
 | 
						|
optIfOChGroupSinkCurDayLowAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest aggregated optical power of all the DWDM input
 | 
						|
     channels in the OChGroup during the current 24-hour interval."
 | 
						|
  ::= { optIfOChGroupSinkCurDayEntry 2 }
 | 
						|
 | 
						|
optIfOChGroupSinkCurDayHighAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest aggregated optical power of all the DWDM input
 | 
						|
     channels in the OChGroup during the current 24-hour interval."
 | 
						|
  ::= { optIfOChGroupSinkCurDayEntry 3 }
 | 
						|
 | 
						|
optIfOChGroupSinkCurDayLowOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest optical power monitored at the output
 | 
						|
     in the OChGroup during the current 24-hour interval."
 | 
						|
  ::= { optIfOChGroupSinkCurDayEntry 4 }
 | 
						|
 | 
						|
optIfOChGroupSinkCurDayHighOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest optical power monitored at the output
 | 
						|
     in the OChGroup during the current 24-hour interval."
 | 
						|
  ::= { optIfOChGroupSinkCurDayEntry 5 }
 | 
						|
 | 
						|
-- OChGroup sink previous day table
 | 
						|
-- Contains data for the previous 24-hour performance
 | 
						|
-- monitoring interval.
 | 
						|
 | 
						|
optIfOChGroupSinkPrevDayTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfOChGroupSinkPrevDayEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of OChGroup sink performance monitoring information for
 | 
						|
     the previous 24-hour interval."
 | 
						|
  ::= { optIfOChGroup 5 }
 | 
						|
 | 
						|
optIfOChGroupSinkPrevDayEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfOChGroupSinkPrevDayEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains OChGroup sink performance
 | 
						|
     monitoring information of an interface for the previous
 | 
						|
     24-hour interval."
 | 
						|
  INDEX  { ifIndex }
 | 
						|
  ::= { optIfOChGroupSinkPrevDayTable 1 }
 | 
						|
 | 
						|
OptIfOChGroupSinkPrevDayEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfOChGroupSinkPrevDaySuspectedFlag             TruthValue,
 | 
						|
    optIfOChGroupSinkPrevDayLastAggregatedInputPower  Integer32,
 | 
						|
    optIfOChGroupSinkPrevDayLowAggregatedInputPower   Integer32,
 | 
						|
    optIfOChGroupSinkPrevDayHighAggregatedInputPower  Integer32,
 | 
						|
    optIfOChGroupSinkPrevDayLastOutputPower           Integer32,
 | 
						|
    optIfOChGroupSinkPrevDayLowOutputPower            Integer32,
 | 
						|
    optIfOChGroupSinkPrevDayHighOutputPower           Integer32
 | 
						|
    }
 | 
						|
 | 
						|
optIfOChGroupSinkPrevDaySuspectedFlag OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "If true, the data in this entry may be unreliable."
 | 
						|
  ::= { optIfOChGroupSinkPrevDayEntry 1 }
 | 
						|
 | 
						|
optIfOChGroupSinkPrevDayLastAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The last aggregated optical power of all the DWDM input
 | 
						|
     channels in the OChGroup during the previous 24-hour interval."
 | 
						|
  ::= { optIfOChGroupSinkPrevDayEntry 2 }
 | 
						|
 | 
						|
optIfOChGroupSinkPrevDayLowAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest aggregated optical power of all the DWDM input
 | 
						|
     channels in the OChGroup during the previous 24-hour interval."
 | 
						|
  ::= { optIfOChGroupSinkPrevDayEntry 3 }
 | 
						|
 | 
						|
optIfOChGroupSinkPrevDayHighAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest aggregated optical power of all the DWDM input
 | 
						|
     channels in the OChGroup during the previous 24-hour interval."
 | 
						|
  ::= { optIfOChGroupSinkPrevDayEntry 4 }
 | 
						|
 | 
						|
optIfOChGroupSinkPrevDayLastOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The last optical power monitored at the output
 | 
						|
     in the OChGroup during the previous 24-hour interval."
 | 
						|
  ::= { optIfOChGroupSinkPrevDayEntry 5 }
 | 
						|
 | 
						|
optIfOChGroupSinkPrevDayLowOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest optical power monitored at the output
 | 
						|
     in the OChGroup during the previous 24-hour interval."
 | 
						|
  ::= { optIfOChGroupSinkPrevDayEntry 6 }
 | 
						|
 | 
						|
optIfOChGroupSinkPrevDayHighOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest optical power monitored at the output
 | 
						|
     in the OChGroup during the previous 24-hour interval."
 | 
						|
  ::= { optIfOChGroupSinkPrevDayEntry 7 }
 | 
						|
 | 
						|
-- OChGroup source current table
 | 
						|
-- Contains data for the current 15-minute performance monitoring
 | 
						|
-- interval.
 | 
						|
 | 
						|
optIfOChGroupSrcCurrentTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfOChGroupSrcCurrentEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of OChGroup source performance monitoring information for
 | 
						|
     the current 15-minute interval."
 | 
						|
  ::= { optIfOChGroup 6 }
 | 
						|
 | 
						|
optIfOChGroupSrcCurrentEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfOChGroupSrcCurrentEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains OChGroup source performance
 | 
						|
     monitoring information of an interface for the current
 | 
						|
     15-minute interval."
 | 
						|
  INDEX  { ifIndex }
 | 
						|
  ::= { optIfOChGroupSrcCurrentTable 1 }
 | 
						|
 | 
						|
OptIfOChGroupSrcCurrentEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfOChGroupSrcCurrentSuspectedFlag              TruthValue,
 | 
						|
    optIfOChGroupSrcCurrentOutputPower                Integer32,
 | 
						|
    optIfOChGroupSrcCurrentLowOutputPower             Integer32,
 | 
						|
    optIfOChGroupSrcCurrentHighOutputPower            Integer32,
 | 
						|
    optIfOChGroupSrcCurrentLowerOutputPowerThreshold  Integer32,
 | 
						|
    optIfOChGroupSrcCurrentUpperOutputPowerThreshold  Integer32,
 | 
						|
    optIfOChGroupSrcCurrentAggregatedInputPower       Integer32,
 | 
						|
    optIfOChGroupSrcCurrentLowAggregatedInputPower    Integer32,
 | 
						|
    optIfOChGroupSrcCurrentHighAggregatedInputPower   Integer32,
 | 
						|
    optIfOChGroupSrcCurrentLowerInputPowerThreshold   Integer32,
 | 
						|
    optIfOChGroupSrcCurrentUpperInputPowerThreshold   Integer32
 | 
						|
    }
 | 
						|
 | 
						|
optIfOChGroupSrcCurrentSuspectedFlag OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "If true, the data in this entry may be unreliable."
 | 
						|
  ::= { optIfOChGroupSrcCurrentEntry 1 }
 | 
						|
 | 
						|
optIfOChGroupSrcCurrentOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The optical power monitored at the output."
 | 
						|
  ::= { optIfOChGroupSrcCurrentEntry 2 }
 | 
						|
 | 
						|
optIfOChGroupSrcCurrentLowOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest optical power monitored at the output during the
 | 
						|
     current 15-minute interval."
 | 
						|
  ::= { optIfOChGroupSrcCurrentEntry 3 }
 | 
						|
 | 
						|
optIfOChGroupSrcCurrentHighOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest optical power monitored at the output during the
 | 
						|
     current 15-minute interval."
 | 
						|
  ::= { optIfOChGroupSrcCurrentEntry 4 }
 | 
						|
 | 
						|
optIfOChGroupSrcCurrentLowerOutputPowerThreshold OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lower limit threshold on output power.  If
 | 
						|
     optIfOChGroupSrcCurrentOutputPower drops to this value or below,
 | 
						|
     a Threshold Crossing Alert (TCA) should be sent."
 | 
						|
  ::= { optIfOChGroupSrcCurrentEntry 5 }
 | 
						|
 | 
						|
optIfOChGroupSrcCurrentUpperOutputPowerThreshold OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The upper limit threshold on output power.  If
 | 
						|
     optIfOChGroupSrcCurrentOutputPower reaches or exceeds this value,
 | 
						|
     a Threshold Crossing Alert (TCA) should be sent."
 | 
						|
  ::= { optIfOChGroupSrcCurrentEntry 6 }
 | 
						|
 | 
						|
optIfOChGroupSrcCurrentAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The aggregated optical power monitored at the input."
 | 
						|
  ::= { optIfOChGroupSrcCurrentEntry 7 }
 | 
						|
 | 
						|
optIfOChGroupSrcCurrentLowAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest aggregated optical power monitored at the input
 | 
						|
     during the current 15-minute interval."
 | 
						|
  ::= { optIfOChGroupSrcCurrentEntry 8 }
 | 
						|
 | 
						|
optIfOChGroupSrcCurrentHighAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest aggregated optical power monitored at the input
 | 
						|
     during the current 15-minute interval."
 | 
						|
  ::= { optIfOChGroupSrcCurrentEntry 9 }
 | 
						|
 | 
						|
optIfOChGroupSrcCurrentLowerInputPowerThreshold OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lower limit threshold on input power.  If
 | 
						|
     optIfOChGroupSrcCurrentAggregatedInputPower drops to this value
 | 
						|
     or below, a Threshold Crossing Alert (TCA) should be sent."
 | 
						|
  ::= { optIfOChGroupSrcCurrentEntry 10 }
 | 
						|
 | 
						|
optIfOChGroupSrcCurrentUpperInputPowerThreshold OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The upper limit threshold on input power.  If
 | 
						|
     optIfOChGroupSrcCurrentAggregatedInputPower reaches or exceeds
 | 
						|
     this value, a Threshold Crossing Alert (TCA) should be sent."
 | 
						|
  ::= { optIfOChGroupSrcCurrentEntry 11 }
 | 
						|
 | 
						|
-- OChGroup source interval table
 | 
						|
-- Contains data for previous 15-minute performance monitoring
 | 
						|
-- intervals.
 | 
						|
 | 
						|
optIfOChGroupSrcIntervalTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfOChGroupSrcIntervalEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of historical OChGroup source performance monitoring
 | 
						|
     information."
 | 
						|
  ::= { optIfOChGroup 7 }
 | 
						|
 | 
						|
optIfOChGroupSrcIntervalEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfOChGroupSrcIntervalEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains OChGroup source performance
 | 
						|
     monitoring information of an interface during a particular
 | 
						|
     historical interval."
 | 
						|
  INDEX  { ifIndex, optIfOChGroupSrcIntervalNumber }
 | 
						|
  ::= { optIfOChGroupSrcIntervalTable 1 }
 | 
						|
 | 
						|
OptIfOChGroupSrcIntervalEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
   optIfOChGroupSrcIntervalNumber                   OptIfIntervalNumber,
 | 
						|
   optIfOChGroupSrcIntervalSuspectedFlag             TruthValue,
 | 
						|
   optIfOChGroupSrcIntervalLastOutputPower           Integer32,
 | 
						|
   optIfOChGroupSrcIntervalLowOutputPower            Integer32,
 | 
						|
   optIfOChGroupSrcIntervalHighOutputPower           Integer32,
 | 
						|
   optIfOChGroupSrcIntervalLastAggregatedInputPower  Integer32,
 | 
						|
   optIfOChGroupSrcIntervalLowAggregatedInputPower   Integer32,
 | 
						|
   optIfOChGroupSrcIntervalHighAggregatedInputPower  Integer32
 | 
						|
   }
 | 
						|
 | 
						|
optIfOChGroupSrcIntervalNumber OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfIntervalNumber
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Uniquely identifies the interval."
 | 
						|
  ::= { optIfOChGroupSrcIntervalEntry 1 }
 | 
						|
 | 
						|
optIfOChGroupSrcIntervalSuspectedFlag OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "If true, the data in this entry may be unreliable."
 | 
						|
  ::= { optIfOChGroupSrcIntervalEntry 2 }
 | 
						|
 | 
						|
optIfOChGroupSrcIntervalLastOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The last optical power monitored at the output during the
 | 
						|
     interval."
 | 
						|
  ::= { optIfOChGroupSrcIntervalEntry 3 }
 | 
						|
 | 
						|
optIfOChGroupSrcIntervalLowOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest optical power monitored at the output during the
 | 
						|
     interval."
 | 
						|
  ::= { optIfOChGroupSrcIntervalEntry 4 }
 | 
						|
 | 
						|
optIfOChGroupSrcIntervalHighOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest optical power monitored at the output during the
 | 
						|
     interval."
 | 
						|
  ::= { optIfOChGroupSrcIntervalEntry 5 }
 | 
						|
 | 
						|
optIfOChGroupSrcIntervalLastAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The last aggregated optical power monitored at the input
 | 
						|
     during the interval."
 | 
						|
  ::= { optIfOChGroupSrcIntervalEntry 6 }
 | 
						|
 | 
						|
optIfOChGroupSrcIntervalLowAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest aggregated optical power monitored at the input
 | 
						|
     during the interval."
 | 
						|
  ::= { optIfOChGroupSrcIntervalEntry 7 }
 | 
						|
 | 
						|
optIfOChGroupSrcIntervalHighAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest aggregated optical power monitored at the input
 | 
						|
     during the interval."
 | 
						|
  ::= { optIfOChGroupSrcIntervalEntry 8 }
 | 
						|
 | 
						|
-- OChGroup source current day table
 | 
						|
-- Contains data for the current 24-hour performance
 | 
						|
-- monitoring interval.
 | 
						|
 | 
						|
optIfOChGroupSrcCurDayTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfOChGroupSrcCurDayEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of OChGroup source performance monitoring information for
 | 
						|
     the current 24-hour interval."
 | 
						|
  ::= { optIfOChGroup 8 }
 | 
						|
 | 
						|
optIfOChGroupSrcCurDayEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfOChGroupSrcCurDayEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains OChGroup source performance
 | 
						|
     monitoring information of an interface for the current
 | 
						|
     24-hour interval."
 | 
						|
  INDEX  { ifIndex }
 | 
						|
  ::= { optIfOChGroupSrcCurDayTable 1 }
 | 
						|
 | 
						|
OptIfOChGroupSrcCurDayEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfOChGroupSrcCurDaySuspectedFlag             TruthValue,
 | 
						|
    optIfOChGroupSrcCurDayLowOutputPower            Integer32,
 | 
						|
    optIfOChGroupSrcCurDayHighOutputPower           Integer32,
 | 
						|
    optIfOChGroupSrcCurDayLowAggregatedInputPower   Integer32,
 | 
						|
    optIfOChGroupSrcCurDayHighAggregatedInputPower  Integer32
 | 
						|
    }
 | 
						|
 | 
						|
optIfOChGroupSrcCurDaySuspectedFlag OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "If true, the data in this entry may be unreliable."
 | 
						|
  ::= { optIfOChGroupSrcCurDayEntry 1 }
 | 
						|
 | 
						|
optIfOChGroupSrcCurDayLowOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest optical power monitored at the output during the
 | 
						|
     current 24-hour interval."
 | 
						|
  ::= { optIfOChGroupSrcCurDayEntry 2 }
 | 
						|
 | 
						|
optIfOChGroupSrcCurDayHighOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest optical power monitored at the output during the
 | 
						|
     current 24-hour interval."
 | 
						|
  ::= { optIfOChGroupSrcCurDayEntry 3 }
 | 
						|
 | 
						|
optIfOChGroupSrcCurDayLowAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest aggregated optical power monitored at the input
 | 
						|
     during the current 24-hour interval."
 | 
						|
  ::= { optIfOChGroupSrcCurDayEntry 4 }
 | 
						|
 | 
						|
optIfOChGroupSrcCurDayHighAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest aggregated optical power monitored at the input
 | 
						|
     during the current 24-hour interval."
 | 
						|
  ::= { optIfOChGroupSrcCurDayEntry 5 }
 | 
						|
 | 
						|
-- OChGroup source previous day table
 | 
						|
-- Contains data for the previous 24-hour performance
 | 
						|
-- monitoring interval.
 | 
						|
 | 
						|
optIfOChGroupSrcPrevDayTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfOChGroupSrcPrevDayEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of OChGroup source performance monitoring information for
 | 
						|
     the previous 24-hour interval."
 | 
						|
  ::= { optIfOChGroup 9 }
 | 
						|
 | 
						|
optIfOChGroupSrcPrevDayEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfOChGroupSrcPrevDayEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains OChGroup source performance
 | 
						|
     monitoring information of an interface for the previous
 | 
						|
     24-hour interval."
 | 
						|
  INDEX  { ifIndex }
 | 
						|
  ::= { optIfOChGroupSrcPrevDayTable 1 }
 | 
						|
 | 
						|
OptIfOChGroupSrcPrevDayEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfOChGroupSrcPrevDaySuspectedFlag             TruthValue,
 | 
						|
    optIfOChGroupSrcPrevDayLastOutputPower           Integer32,
 | 
						|
    optIfOChGroupSrcPrevDayLowOutputPower            Integer32,
 | 
						|
    optIfOChGroupSrcPrevDayHighOutputPower           Integer32,
 | 
						|
    optIfOChGroupSrcPrevDayLastAggregatedInputPower  Integer32,
 | 
						|
    optIfOChGroupSrcPrevDayLowAggregatedInputPower   Integer32,
 | 
						|
    optIfOChGroupSrcPrevDayHighAggregatedInputPower  Integer32
 | 
						|
    }
 | 
						|
 | 
						|
optIfOChGroupSrcPrevDaySuspectedFlag OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "If true, the data in this entry may be unreliable."
 | 
						|
  ::= { optIfOChGroupSrcPrevDayEntry 1 }
 | 
						|
 | 
						|
optIfOChGroupSrcPrevDayLastOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The last optical power monitored at the output during the
 | 
						|
     previous 24-hour interval."
 | 
						|
  ::= { optIfOChGroupSrcPrevDayEntry 2 }
 | 
						|
 | 
						|
optIfOChGroupSrcPrevDayLowOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest optical power monitored at the output during the
 | 
						|
     previous 24-hour interval."
 | 
						|
  ::= { optIfOChGroupSrcPrevDayEntry 3 }
 | 
						|
 | 
						|
optIfOChGroupSrcPrevDayHighOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest optical power monitored at the output during the
 | 
						|
     previous 24-hour interval."
 | 
						|
  ::= { optIfOChGroupSrcPrevDayEntry 4 }
 | 
						|
 | 
						|
optIfOChGroupSrcPrevDayLastAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The last aggregated optical power monitored at the input
 | 
						|
     during the previous 24-hour interval."
 | 
						|
  ::= { optIfOChGroupSrcPrevDayEntry 5 }
 | 
						|
 | 
						|
optIfOChGroupSrcPrevDayLowAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest aggregated optical power monitored at the input
 | 
						|
     during the previous 24-hour interval."
 | 
						|
  ::= { optIfOChGroupSrcPrevDayEntry 6 }
 | 
						|
 | 
						|
optIfOChGroupSrcPrevDayHighAggregatedInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest aggregated optical power monitored at the input
 | 
						|
     during the previous 24-hour interval."
 | 
						|
  ::= { optIfOChGroupSrcPrevDayEntry 7 }
 | 
						|
 | 
						|
-- the optIfOCh group
 | 
						|
-- This group handles the configuration and
 | 
						|
-- performance monitoring information for OCh layers.
 | 
						|
 | 
						|
-- OCh config table
 | 
						|
 | 
						|
optIfOChConfigTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfOChConfigEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of OCh configuration information."
 | 
						|
  ::= { optIfOCh 1 }
 | 
						|
 | 
						|
optIfOChConfigEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfOChConfigEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains OCh configuration
 | 
						|
     information of an interface."
 | 
						|
  INDEX  { ifIndex }
 | 
						|
  ::= { optIfOChConfigTable 1 }
 | 
						|
 | 
						|
OptIfOChConfigEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfOChDirectionality     OptIfDirectionality,
 | 
						|
    optIfOChCurrentStatus      BITS
 | 
						|
    }
 | 
						|
 | 
						|
optIfOChDirectionality OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfDirectionality
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the directionality of the entity."
 | 
						|
  ::= { optIfOChConfigEntry 1 }
 | 
						|
 | 
						|
optIfOChCurrentStatus OBJECT-TYPE
 | 
						|
  SYNTAX  BITS {
 | 
						|
    losP(0),
 | 
						|
    los(1),
 | 
						|
    oci(2),
 | 
						|
    ssfP(3),
 | 
						|
    ssfO(4),
 | 
						|
    ssf(5)
 | 
						|
    }
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the defect condition of the entity, if any.
 | 
						|
     This object is applicable when optIfOChDirectionality
 | 
						|
     has the value sink(1) or bidirectional(3).
 | 
						|
     In full-capability systems the bit position los(1) is not used.
 | 
						|
     In reduced-capability systems or at IrDI interfaces only
 | 
						|
     the bit positions los(1) and ssfP(3) are used."
 | 
						|
  ::= { optIfOChConfigEntry 2 }
 | 
						|
 | 
						|
-- OCh sink current table
 | 
						|
-- Contains data for the current 15-minute performance monitoring
 | 
						|
-- interval.
 | 
						|
 | 
						|
optIfOChSinkCurrentTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfOChSinkCurrentEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of OCh sink performance monitoring information for
 | 
						|
     the current 15-minute interval."
 | 
						|
  ::= { optIfOCh 2 }
 | 
						|
 | 
						|
optIfOChSinkCurrentEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfOChSinkCurrentEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains OCh sink performance
 | 
						|
     monitoring information for an interface for the current
 | 
						|
     15-minute interval."
 | 
						|
  INDEX  { ifIndex }
 | 
						|
  ::= { optIfOChSinkCurrentTable 1 }
 | 
						|
 | 
						|
OptIfOChSinkCurrentEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfOChSinkCurrentSuspectedFlag             TruthValue,
 | 
						|
    optIfOChSinkCurrentInputPower                Integer32,
 | 
						|
    optIfOChSinkCurrentLowInputPower             Integer32,
 | 
						|
    optIfOChSinkCurrentHighInputPower            Integer32,
 | 
						|
    optIfOChSinkCurrentLowerInputPowerThreshold  Integer32,
 | 
						|
    optIfOChSinkCurrentUpperInputPowerThreshold  Integer32
 | 
						|
    }
 | 
						|
 | 
						|
optIfOChSinkCurrentSuspectedFlag OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "If true, the data in this entry may be unreliable."
 | 
						|
  ::= { optIfOChSinkCurrentEntry 1 }
 | 
						|
 | 
						|
optIfOChSinkCurrentInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The optical power monitored at the input."
 | 
						|
  ::= { optIfOChSinkCurrentEntry 2 }
 | 
						|
 | 
						|
optIfOChSinkCurrentLowInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest optical power monitored at the input during the
 | 
						|
     current 15-minute interval."
 | 
						|
  ::= { optIfOChSinkCurrentEntry 3 }
 | 
						|
 | 
						|
optIfOChSinkCurrentHighInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest optical power monitored at the input during the
 | 
						|
     current 15-minute interval."
 | 
						|
  ::= { optIfOChSinkCurrentEntry 4 }
 | 
						|
 | 
						|
optIfOChSinkCurrentLowerInputPowerThreshold OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lower limit threshold on input power.  If
 | 
						|
     optIfOChSinkCurrentInputPower drops to this value or below,
 | 
						|
     a Threshold Crossing Alert (TCA) should be sent."
 | 
						|
  ::= { optIfOChSinkCurrentEntry 5 }
 | 
						|
 | 
						|
optIfOChSinkCurrentUpperInputPowerThreshold OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The upper limit threshold on input power.  If
 | 
						|
     optIfOChSinkCurrentInputPower reaches or exceeds this value,
 | 
						|
     a Threshold Crossing Alert (TCA) should be sent."
 | 
						|
  ::= { optIfOChSinkCurrentEntry 6 }
 | 
						|
 | 
						|
-- OCh sink interval table
 | 
						|
-- Contains data for previous 15-minute performance monitoring
 | 
						|
-- intervals.
 | 
						|
 | 
						|
optIfOChSinkIntervalTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfOChSinkIntervalEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of historical OCh sink performance monitoring
 | 
						|
     information."
 | 
						|
  ::= { optIfOCh 3 }
 | 
						|
 | 
						|
optIfOChSinkIntervalEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfOChSinkIntervalEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains OCh sink performance
 | 
						|
     monitoring information of an interface during a particular
 | 
						|
     historical interval."
 | 
						|
  INDEX  { ifIndex, optIfOChSinkIntervalNumber }
 | 
						|
  ::= { optIfOChSinkIntervalTable 1 }
 | 
						|
 | 
						|
OptIfOChSinkIntervalEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfOChSinkIntervalNumber          OptIfIntervalNumber,
 | 
						|
    optIfOChSinkIntervalSuspectedFlag   TruthValue,
 | 
						|
    optIfOChSinkIntervalLastInputPower  Integer32,
 | 
						|
    optIfOChSinkIntervalLowInputPower   Integer32,
 | 
						|
    optIfOChSinkIntervalHighInputPower  Integer32
 | 
						|
    }
 | 
						|
 | 
						|
optIfOChSinkIntervalNumber OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfIntervalNumber
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Uniquely identifies the interval."
 | 
						|
  ::= { optIfOChSinkIntervalEntry 1 }
 | 
						|
 | 
						|
optIfOChSinkIntervalSuspectedFlag OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "If true, the data in this entry may be unreliable."
 | 
						|
  ::= { optIfOChSinkIntervalEntry 2 }
 | 
						|
 | 
						|
optIfOChSinkIntervalLastInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The last optical power monitored at the input during the
 | 
						|
     interval."
 | 
						|
  ::= { optIfOChSinkIntervalEntry 3 }
 | 
						|
 | 
						|
optIfOChSinkIntervalLowInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest optical power monitored at the input during the
 | 
						|
     interval."
 | 
						|
  ::= { optIfOChSinkIntervalEntry 4 }
 | 
						|
 | 
						|
optIfOChSinkIntervalHighInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest optical power monitored at the input during the
 | 
						|
     interval."
 | 
						|
  ::= { optIfOChSinkIntervalEntry 5 }
 | 
						|
 | 
						|
-- OCh sink current day table
 | 
						|
-- Contains data for the current 24-hour performance
 | 
						|
-- monitoring interval.
 | 
						|
 | 
						|
optIfOChSinkCurDayTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfOChSinkCurDayEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of OCh sink performance monitoring information for
 | 
						|
     the current 24-hour interval."
 | 
						|
  ::= { optIfOCh 4 }
 | 
						|
 | 
						|
optIfOChSinkCurDayEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfOChSinkCurDayEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains OCh sink performance
 | 
						|
     monitoring information of an interface for the current
 | 
						|
     24-hour interval."
 | 
						|
  INDEX  { ifIndex }
 | 
						|
  ::= { optIfOChSinkCurDayTable 1 }
 | 
						|
 | 
						|
OptIfOChSinkCurDayEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfOChSinkCurDaySuspectedFlag   TruthValue,
 | 
						|
    optIfOChSinkCurDayLowInputPower   Integer32,
 | 
						|
    optIfOChSinkCurDayHighInputPower  Integer32
 | 
						|
    }
 | 
						|
 | 
						|
optIfOChSinkCurDaySuspectedFlag OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "If true, the data in this entry may be unreliable."
 | 
						|
  ::= { optIfOChSinkCurDayEntry 1 }
 | 
						|
 | 
						|
optIfOChSinkCurDayLowInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest optical power monitored at the input during the
 | 
						|
     current 24-hour interval."
 | 
						|
  ::= { optIfOChSinkCurDayEntry 2 }
 | 
						|
 | 
						|
optIfOChSinkCurDayHighInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest optical power monitored at the input during the
 | 
						|
     current 24-hour interval."
 | 
						|
  ::= { optIfOChSinkCurDayEntry 3 }
 | 
						|
 | 
						|
-- OCh sink previous day table
 | 
						|
-- Contains data for the previous 24-hour performance
 | 
						|
-- monitoring interval.
 | 
						|
 | 
						|
optIfOChSinkPrevDayTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfOChSinkPrevDayEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of OCh sink performance monitoring information for
 | 
						|
     the previous 24-hour interval."
 | 
						|
  ::= { optIfOCh 5 }
 | 
						|
 | 
						|
optIfOChSinkPrevDayEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfOChSinkPrevDayEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains OCh sink performance
 | 
						|
     monitoring information of an interface for the previous
 | 
						|
     24-hour interval."
 | 
						|
  INDEX  { ifIndex }
 | 
						|
  ::= { optIfOChSinkPrevDayTable 1 }
 | 
						|
 | 
						|
OptIfOChSinkPrevDayEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfOChSinkPrevDaySuspectedFlag   TruthValue,
 | 
						|
    optIfOChSinkPrevDayLastInputPower  Integer32,
 | 
						|
    optIfOChSinkPrevDayLowInputPower   Integer32,
 | 
						|
    optIfOChSinkPrevDayHighInputPower  Integer32
 | 
						|
    }
 | 
						|
 | 
						|
optIfOChSinkPrevDaySuspectedFlag OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "If true, the data in this entry may be unreliable."
 | 
						|
  ::= { optIfOChSinkPrevDayEntry 1 }
 | 
						|
 | 
						|
optIfOChSinkPrevDayLastInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The last optical power monitored at the input during the
 | 
						|
     previous 24-hour interval."
 | 
						|
  ::= { optIfOChSinkPrevDayEntry 2 }
 | 
						|
 | 
						|
optIfOChSinkPrevDayLowInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest optical power monitored at the input during the
 | 
						|
     previous 24-hour interval."
 | 
						|
  ::= { optIfOChSinkPrevDayEntry 3 }
 | 
						|
 | 
						|
optIfOChSinkPrevDayHighInputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest optical power monitored at the input during the
 | 
						|
     previous 24-hour interval."
 | 
						|
  ::= { optIfOChSinkPrevDayEntry 4 }
 | 
						|
 | 
						|
-- OCh source current table
 | 
						|
-- Contains data for the current 15-minute performance monitoring
 | 
						|
-- interval.
 | 
						|
 | 
						|
optIfOChSrcCurrentTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfOChSrcCurrentEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of OCh source performance monitoring information for
 | 
						|
     the current 15-minute interval."
 | 
						|
  ::= { optIfOCh 6 }
 | 
						|
 | 
						|
optIfOChSrcCurrentEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfOChSrcCurrentEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains OCh source performance
 | 
						|
     monitoring information of an interface for the current
 | 
						|
     15-minute interval."
 | 
						|
  INDEX  { ifIndex }
 | 
						|
  ::= { optIfOChSrcCurrentTable 1 }
 | 
						|
 | 
						|
OptIfOChSrcCurrentEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfOChSrcCurrentSuspectedFlag              TruthValue,
 | 
						|
    optIfOChSrcCurrentOutputPower                Integer32,
 | 
						|
    optIfOChSrcCurrentLowOutputPower             Integer32,
 | 
						|
    optIfOChSrcCurrentHighOutputPower            Integer32,
 | 
						|
    optIfOChSrcCurrentLowerOutputPowerThreshold  Integer32,
 | 
						|
    optIfOChSrcCurrentUpperOutputPowerThreshold  Integer32
 | 
						|
    }
 | 
						|
 | 
						|
optIfOChSrcCurrentSuspectedFlag OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "If true, the data in this entry may be unreliable."
 | 
						|
  ::= { optIfOChSrcCurrentEntry 1 }
 | 
						|
 | 
						|
optIfOChSrcCurrentOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The optical power monitored at the output."
 | 
						|
  ::= { optIfOChSrcCurrentEntry 2 }
 | 
						|
 | 
						|
optIfOChSrcCurrentLowOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest optical power monitored at the output during the
 | 
						|
     current 15-minute interval."
 | 
						|
  ::= { optIfOChSrcCurrentEntry 3 }
 | 
						|
 | 
						|
optIfOChSrcCurrentHighOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest optical power monitored at the output during the
 | 
						|
     current 15-minute interval."
 | 
						|
  ::= { optIfOChSrcCurrentEntry 4 }
 | 
						|
 | 
						|
optIfOChSrcCurrentLowerOutputPowerThreshold OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lower limit threshold on output power.  If
 | 
						|
     optIfOChSrcCurrentOutputPower drops to this value or below,
 | 
						|
     a Threshold Crossing Alert (TCA) should be sent."
 | 
						|
  ::= { optIfOChSrcCurrentEntry 5 }
 | 
						|
 | 
						|
optIfOChSrcCurrentUpperOutputPowerThreshold OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The upper limit threshold on output power.  If
 | 
						|
     optIfOChSrcCurrentOutputPower reaches or exceeds this value,
 | 
						|
     a Threshold Crossing Alert (TCA) should be sent."
 | 
						|
  ::= { optIfOChSrcCurrentEntry 6 }
 | 
						|
 | 
						|
-- OCh source interval table
 | 
						|
-- Contains data for previous 15-minute performance monitoring
 | 
						|
-- intervals.
 | 
						|
 | 
						|
optIfOChSrcIntervalTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfOChSrcIntervalEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of historical OCh source performance monitoring
 | 
						|
     information."
 | 
						|
  ::= { optIfOCh 7 }
 | 
						|
 | 
						|
optIfOChSrcIntervalEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfOChSrcIntervalEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains OCh source performance
 | 
						|
     monitoring information of an interface during a particular
 | 
						|
     historical interval."
 | 
						|
  INDEX  { ifIndex, optIfOChSrcIntervalNumber }
 | 
						|
  ::= { optIfOChSrcIntervalTable 1 }
 | 
						|
 | 
						|
OptIfOChSrcIntervalEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfOChSrcIntervalNumber           OptIfIntervalNumber,
 | 
						|
    optIfOChSrcIntervalSuspectedFlag    TruthValue,
 | 
						|
    optIfOChSrcIntervalLastOutputPower  Integer32,
 | 
						|
    optIfOChSrcIntervalLowOutputPower   Integer32,
 | 
						|
    optIfOChSrcIntervalHighOutputPower  Integer32
 | 
						|
    }
 | 
						|
 | 
						|
optIfOChSrcIntervalNumber OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfIntervalNumber
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Uniquely identifies the interval."
 | 
						|
  ::= { optIfOChSrcIntervalEntry 1 }
 | 
						|
 | 
						|
optIfOChSrcIntervalSuspectedFlag OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "If true, the data in this entry may be unreliable."
 | 
						|
  ::= { optIfOChSrcIntervalEntry 2 }
 | 
						|
 | 
						|
optIfOChSrcIntervalLastOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The last optical power monitored at the output during the
 | 
						|
     interval."
 | 
						|
  ::= { optIfOChSrcIntervalEntry 3 }
 | 
						|
 | 
						|
optIfOChSrcIntervalLowOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest optical power monitored at the output during the
 | 
						|
     interval."
 | 
						|
  ::= { optIfOChSrcIntervalEntry 4 }
 | 
						|
 | 
						|
optIfOChSrcIntervalHighOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest optical power monitored at the output during the
 | 
						|
     interval."
 | 
						|
  ::= { optIfOChSrcIntervalEntry 5 }
 | 
						|
 | 
						|
-- OCh source current day table
 | 
						|
-- Contains data for the current 24-hour performance
 | 
						|
-- monitoring interval.
 | 
						|
 | 
						|
optIfOChSrcCurDayTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfOChSrcCurDayEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of OCh source performance monitoring information for
 | 
						|
     the current 24-hour interval."
 | 
						|
  ::= { optIfOCh 8 }
 | 
						|
 | 
						|
optIfOChSrcCurDayEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfOChSrcCurDayEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains OCh source performance
 | 
						|
     monitoring information of an interface for the current
 | 
						|
     24-hour interval."
 | 
						|
  INDEX  { ifIndex }
 | 
						|
  ::= { optIfOChSrcCurDayTable 1 }
 | 
						|
 | 
						|
OptIfOChSrcCurDayEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfOChSrcCurDaySuspectedFlag    TruthValue,
 | 
						|
    optIfOChSrcCurDayLowOutputPower   Integer32,
 | 
						|
    optIfOChSrcCurDayHighOutputPower  Integer32
 | 
						|
    }
 | 
						|
 | 
						|
optIfOChSrcCurDaySuspectedFlag OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "If true, the data in this entry may be unreliable."
 | 
						|
  ::= { optIfOChSrcCurDayEntry 1 }
 | 
						|
 | 
						|
optIfOChSrcCurDayLowOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest optical power monitored at the output during the
 | 
						|
     current 24-hour interval."
 | 
						|
  ::= { optIfOChSrcCurDayEntry 2 }
 | 
						|
 | 
						|
optIfOChSrcCurDayHighOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest optical power monitored at the output during the
 | 
						|
     current 24-hour interval."
 | 
						|
  ::= { optIfOChSrcCurDayEntry 3 }
 | 
						|
 | 
						|
-- OCh source previous day table
 | 
						|
-- Contains data for the previous 24-hour performance
 | 
						|
-- monitoring interval.
 | 
						|
 | 
						|
optIfOChSrcPrevDayTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfOChSrcPrevDayEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of OCh source performance monitoring information for
 | 
						|
     the previous 24-hour interval."
 | 
						|
  ::= { optIfOCh 9 }
 | 
						|
 | 
						|
optIfOChSrcPrevDayEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfOChSrcPrevDayEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains OCh source performance
 | 
						|
     monitoring information of an interface for the previous
 | 
						|
     24-hour interval."
 | 
						|
  INDEX  { ifIndex }
 | 
						|
  ::= { optIfOChSrcPrevDayTable 1 }
 | 
						|
 | 
						|
OptIfOChSrcPrevDayEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfOChSrcPrevDaySuspectedFlag    TruthValue,
 | 
						|
    optIfOChSrcPrevDayLastOutputPower  Integer32,
 | 
						|
    optIfOChSrcPrevDayLowOutputPower   Integer32,
 | 
						|
    optIfOChSrcPrevDayHighOutputPower  Integer32
 | 
						|
    }
 | 
						|
 | 
						|
optIfOChSrcPrevDaySuspectedFlag OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "If true, the data in this entry may be unreliable."
 | 
						|
  ::= { optIfOChSrcPrevDayEntry 1 }
 | 
						|
 | 
						|
optIfOChSrcPrevDayLastOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The last optical power monitored at the output during the
 | 
						|
     previous 24-hour interval."
 | 
						|
  ::= { optIfOChSrcPrevDayEntry 2 }
 | 
						|
 | 
						|
optIfOChSrcPrevDayLowOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The lowest optical power monitored at the output during the
 | 
						|
     previous 24-hour interval."
 | 
						|
  ::= { optIfOChSrcPrevDayEntry 3 }
 | 
						|
 | 
						|
optIfOChSrcPrevDayHighOutputPower OBJECT-TYPE
 | 
						|
  SYNTAX  Integer32
 | 
						|
  UNITS  "0.1 dbm"
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The highest optical power monitored at the output during the
 | 
						|
     previous 24-hour interval."
 | 
						|
  ::= { optIfOChSrcPrevDayEntry 4 }
 | 
						|
 | 
						|
-- the optIfOTUk group
 | 
						|
-- This group handles the configuration
 | 
						|
-- information for OTUk layers.
 | 
						|
 | 
						|
-- OTUk config table
 | 
						|
 | 
						|
optIfOTUkConfigTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfOTUkConfigEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of OTUk configuration information."
 | 
						|
  ::= { optIfOTUk 1 }
 | 
						|
 | 
						|
optIfOTUkConfigEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfOTUkConfigEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains OTUk configuration
 | 
						|
     information of an interface."
 | 
						|
  INDEX  { ifIndex }
 | 
						|
  ::= { optIfOTUkConfigTable 1 }
 | 
						|
 | 
						|
OptIfOTUkConfigEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfOTUkDirectionality              OptIfDirectionality,
 | 
						|
    optIfOTUkBitRateK                    OptIfBitRateK,
 | 
						|
    optIfOTUkTraceIdentifierTransmitted  OptIfTxTI,
 | 
						|
    optIfOTUkDAPIExpected                OptIfExDAPI,
 | 
						|
    optIfOTUkSAPIExpected                OptIfExSAPI,
 | 
						|
    optIfOTUkTraceIdentifierAccepted     OptIfAcTI,
 | 
						|
    optIfOTUkTIMDetMode                  OptIfTIMDetMode,
 | 
						|
    optIfOTUkTIMActEnabled               TruthValue,
 | 
						|
    optIfOTUkDEGThr                      OptIfDEGThr,
 | 
						|
    optIfOTUkDEGM                        OptIfDEGM,
 | 
						|
    optIfOTUkSinkAdaptActive             TruthValue,
 | 
						|
    optIfOTUkSourceAdaptActive           TruthValue,
 | 
						|
    optIfOTUkSinkFECEnabled              TruthValue,
 | 
						|
    optIfOTUkCurrentStatus               BITS
 | 
						|
    }
 | 
						|
 | 
						|
optIfOTUkDirectionality OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfDirectionality
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the directionality of the entity."
 | 
						|
  ::= { optIfOTUkConfigEntry 1 }
 | 
						|
 | 
						|
optIfOTUkBitRateK OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfBitRateK
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the bit rate of the entity."
 | 
						|
  ::= { optIfOTUkConfigEntry 2 }
 | 
						|
 | 
						|
optIfOTUkTraceIdentifierTransmitted OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfTxTI
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The trace identifier transmitted.
 | 
						|
     This object is applicable when optIfOTUkDirectionality
 | 
						|
     has the value source(2) or bidirectional(3).  It must not
 | 
						|
     be instantiated in rows where optIfOTUkDirectionality
 | 
						|
     has the value sink(1).
 | 
						|
     If no value is ever set by a management entity for this
 | 
						|
     object, system-specific default value will be used.
 | 
						|
     Any implementation that instantiates this object must
 | 
						|
     document the system-specific default value or how it
 | 
						|
     is derived."
 | 
						|
  ::= { optIfOTUkConfigEntry 3 }
 | 
						|
 | 
						|
optIfOTUkDAPIExpected OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfExDAPI
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The DAPI expected by the receiver.
 | 
						|
     This object is only applicable to the sink function, i.e.,
 | 
						|
     only when optIfOTUkDirectionality has the value sink(1)
 | 
						|
     or bidirectional(3).  It must not be instantiated in rows
 | 
						|
     where optIfOTUkDirectionality has the value source(2).
 | 
						|
     This object has no effect when optIfOTUkTIMDetMode has
 | 
						|
     the value off(1)."
 | 
						|
  ::= { optIfOTUkConfigEntry 4 }
 | 
						|
 | 
						|
optIfOTUkSAPIExpected OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfExSAPI
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The SAPI expected by the receiver.
 | 
						|
     This object is only applicable to the sink function, i.e.,
 | 
						|
     only when optIfOTUkDirectionality has the value sink(1)
 | 
						|
     or bidirectional(3).  It must not be instantiated in rows
 | 
						|
     where optIfOTUkDirectionality has the value source(2).
 | 
						|
     This object has no effect when optIfOTUkTIMDetMode has
 | 
						|
     the value off(1)."
 | 
						|
  ::= { optIfOTUkConfigEntry 5 }
 | 
						|
 | 
						|
optIfOTUkTraceIdentifierAccepted OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfAcTI
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The actual trace identifier accepted.
 | 
						|
     This object is only applicable to the sink function, i.e.,
 | 
						|
     only when optIfOTUkDirectionality has the value sink(1)
 | 
						|
     or bidirectional(3).  It must not be instantiated in rows
 | 
						|
     where optIfOTUkDirectionality has the value source(2).
 | 
						|
     The value of this object is unspecified when
 | 
						|
     optIfOTUkCurrentStatus indicates a near-end defect
 | 
						|
     (i.e., ssf(3), lof(4), ais(5), lom(6)) that prevents
 | 
						|
     extraction of the trace message."
 | 
						|
  ::= { optIfOTUkConfigEntry 6 }
 | 
						|
 | 
						|
optIfOTUkTIMDetMode OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfTIMDetMode
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the mode of the Trace Identifier Mismatch (TIM)
 | 
						|
     Detection function.
 | 
						|
     This object is only applicable to the sink function, i.e.,
 | 
						|
     only when optIfOTUkDirectionality has the value sink(1)
 | 
						|
     or bidirectional(3).  It must not be instantiated in rows
 | 
						|
     where optIfOTUkDirectionality has the value source(2).
 | 
						|
     The default value of this object is off(1)."
 | 
						|
  ::= { optIfOTUkConfigEntry 7 }
 | 
						|
 | 
						|
optIfOTUkTIMActEnabled OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates whether the Trace Identifier Mismatch (TIM)
 | 
						|
     Consequent Action function is enabled.
 | 
						|
     This object is only applicable to the sink function, i.e.,
 | 
						|
     only when optIfOTUkDirectionality has the value sink(1)
 | 
						|
     or bidirectional(3).  It must not be instantiated in rows
 | 
						|
     where optIfOTUkDirectionality has the value source(2).
 | 
						|
     This object has no effect when optIfOTUkTIMDetMode has
 | 
						|
     the value off(1).
 | 
						|
     The default value of this object is false(2)."
 | 
						|
  ::= { optIfOTUkConfigEntry 8 }
 | 
						|
 | 
						|
optIfOTUkDEGThr OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfDEGThr
 | 
						|
  UNITS   "percentage"
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the threshold level for declaring a performance
 | 
						|
     monitoring (PM) Second to be bad.  A PM Second is declared bad if
 | 
						|
     the percentage of detected errored blocks in that second is
 | 
						|
     greater than or equal to optIfOTUkDEGThr.
 | 
						|
     This object is only applicable to the sink function, i.e.,
 | 
						|
     only when optIfOTUkDirectionality has the value sink(1)
 | 
						|
     or bidirectional(3).  It must not be instantiated in rows
 | 
						|
     where optIfOTUkDirectionality has the value source(2).
 | 
						|
     The default value of this object is Severely Errored Second
 | 
						|
     (SES) Estimator (See ITU-T G.7710)."
 | 
						|
  ::= { optIfOTUkConfigEntry 9 }
 | 
						|
 | 
						|
optIfOTUkDEGM OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfDEGM
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the threshold level for declaring a Degraded Signal
 | 
						|
     defect (dDEG).  A dDEG shall be declared if optIfOTUkDEGM
 | 
						|
     consecutive bad PM Seconds are detected.
 | 
						|
     This object is only applicable to the sink function, i.e.,
 | 
						|
     only when optIfOTUkDirectionality has the value sink(1)
 | 
						|
     or bidirectional(3).  It must not be instantiated in rows
 | 
						|
     where optIfOTUkDirectionality has the value source(2).
 | 
						|
     The default value of this object is 7 (See ITU-T G.7710)."
 | 
						|
  ::= { optIfOTUkConfigEntry 10 }
 | 
						|
 | 
						|
optIfOTUkSinkAdaptActive OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates whether the sink adaptation function is activated or
 | 
						|
     not.
 | 
						|
     This object is only applicable to the sink function, i.e.,
 | 
						|
     only when optIfOTUkDirectionality has the value sink(1)
 | 
						|
     or bidirectional(3).  It must not be instantiated in rows
 | 
						|
     where optIfOTUkDirectionality has the value source(2).
 | 
						|
     The default value of this object is false(2)."
 | 
						|
  ::= { optIfOTUkConfigEntry 11 }
 | 
						|
 | 
						|
optIfOTUkSourceAdaptActive OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates whether the source adaptation function is activated or
 | 
						|
     not.
 | 
						|
     This object is only applicable to the source function, i.e.,
 | 
						|
     only when optIfOTUkDirectionality has the value source(2)
 | 
						|
     or bidirectional(3).  It must not be instantiated in rows
 | 
						|
     where optIfOTUkDirectionality has the value sink(1).
 | 
						|
     The default value of this object is false(2)."
 | 
						|
  ::= { optIfOTUkConfigEntry 12 }
 | 
						|
 | 
						|
optIfOTUkSinkFECEnabled OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "If Forward Error Correction (FEC) is supported, this object
 | 
						|
     indicates whether FEC at the OTUk sink adaptation function is
 | 
						|
     enabled or not.
 | 
						|
     This object is only applicable to the sink function, i.e.,
 | 
						|
     only when optIfOTUkDirectionality has the value sink(1)
 | 
						|
     or bidirectional(3).  It must not be instantiated in rows
 | 
						|
     where optIfOTUkDirectionality has the value source(2).
 | 
						|
     The default value of this object is true(1)."
 | 
						|
  ::= { optIfOTUkConfigEntry 13 }
 | 
						|
 | 
						|
optIfOTUkCurrentStatus OBJECT-TYPE
 | 
						|
  SYNTAX  BITS {
 | 
						|
    tim(0),
 | 
						|
    deg(1),
 | 
						|
    bdi(2),
 | 
						|
    ssf(3),
 | 
						|
    lof(4),
 | 
						|
    ais(5),
 | 
						|
    lom(6)
 | 
						|
    }
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the defect condition of the entity, if any.
 | 
						|
     This object is only applicable to the sink function, i.e.,
 | 
						|
     only when optIfOTUkDirectionality has the value sink(1)
 | 
						|
     or bidirectional(3).  It must not be instantiated in rows
 | 
						|
     where optIfOTUkDirectionality has the value source(2)."
 | 
						|
  ::= { optIfOTUkConfigEntry 14 }
 | 
						|
 | 
						|
-- GCC0 config table
 | 
						|
 | 
						|
optIfGCC0ConfigTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfGCC0ConfigEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of GCC0 configuration information."
 | 
						|
  ::= { optIfOTUk 2 }
 | 
						|
 | 
						|
 | 
						|
optIfGCC0ConfigEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfGCC0ConfigEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains GCC0 configuration
 | 
						|
     information of an interface.  Each instance must
 | 
						|
     correspond to an instance of optIfOTUkConfigEntry.
 | 
						|
     Separate source and/or sink instances may exist
 | 
						|
     for a given ifIndex value, or a single bidirectional
 | 
						|
     instance may exist, but a bidirectional instance may
 | 
						|
     not coexist with a source or sink instance.
 | 
						|
     Instances of this conceptual row persist across
 | 
						|
     agent restarts."
 | 
						|
  INDEX  { ifIndex, optIfGCC0Directionality }
 | 
						|
  ::= { optIfGCC0ConfigTable 1 }
 | 
						|
 | 
						|
OptIfGCC0ConfigEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfGCC0Directionality            OptIfDirectionality,
 | 
						|
    optIfGCC0Application               SnmpAdminString,
 | 
						|
    optIfGCC0RowStatus                 RowStatus
 | 
						|
    }
 | 
						|
 | 
						|
optIfGCC0Directionality OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfDirectionality
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the directionality of the entity.
 | 
						|
     The values source(2) and bidirectional(3) are
 | 
						|
     not allowed if the corresponding instance of
 | 
						|
     optIfOTUkDirectionality has the value sink(1).
 | 
						|
     The values sink(1) and bidirectional(3) are
 | 
						|
     not allowed if the corresponding instance of
 | 
						|
     optIfOTUkDirectionality has the value source(2)."
 | 
						|
  ::= { optIfGCC0ConfigEntry 1 }
 | 
						|
 | 
						|
optIfGCC0Application OBJECT-TYPE
 | 
						|
  SYNTAX  SnmpAdminString
 | 
						|
  MAX-ACCESS  read-create
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the application transported by the GCC0 entity.
 | 
						|
     Example applications are ECC, User data channel.
 | 
						|
 | 
						|
     The value of this object may not be changed when
 | 
						|
     optIfGCC0RowStatus has the value active(1)."
 | 
						|
  ::= { optIfGCC0ConfigEntry 2 }
 | 
						|
 | 
						|
optIfGCC0RowStatus OBJECT-TYPE
 | 
						|
  SYNTAX  RowStatus
 | 
						|
  MAX-ACCESS  read-create
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "This columnar object is used for creating and deleting a
 | 
						|
     conceptual row of the optIfGCC0 config table.
 | 
						|
     It is used to model the addGCC0Access and removeGCC0Access
 | 
						|
     operations of an OTUk_TTP for GCC0 access control as defined
 | 
						|
     in G.874.1.  Setting RowStatus to createAndGo or createAndWait
 | 
						|
     implies addGCC0Access.  Setting RowStatus to destroy implies
 | 
						|
     removeGCC0Access."
 | 
						|
  ::= { optIfGCC0ConfigEntry 3 }
 | 
						|
 | 
						|
-- the optIfODUk group
 | 
						|
-- This group handles the configuration information
 | 
						|
-- for the ODUk layers.
 | 
						|
 | 
						|
-- ODUk config table
 | 
						|
 | 
						|
optIfODUkConfigTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfODUkConfigEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of ODUk configuration information."
 | 
						|
  ::= { optIfODUk 1 }
 | 
						|
 | 
						|
optIfODUkConfigEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfODUkConfigEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains ODUk configuration
 | 
						|
     information of an interface."
 | 
						|
  INDEX  { ifIndex }
 | 
						|
  ::= { optIfODUkConfigTable 1 }
 | 
						|
 | 
						|
OptIfODUkConfigEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfODUkDirectionality              OptIfDirectionality,
 | 
						|
    optIfODUkBitRateK                    OptIfBitRateK,
 | 
						|
    optIfODUkTcmFieldsInUse              BITS,
 | 
						|
    optIfODUkPositionSeqCurrentSize      Unsigned32,
 | 
						|
    optIfODUkTtpPresent                  TruthValue
 | 
						|
    }
 | 
						|
 | 
						|
optIfODUkDirectionality OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfDirectionality
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the directionality of the entity."
 | 
						|
  ::= { optIfODUkConfigEntry 1 }
 | 
						|
 | 
						|
optIfODUkBitRateK OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfBitRateK
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the bit rate of the entity."
 | 
						|
  ::= { optIfODUkConfigEntry 2 }
 | 
						|
 | 
						|
optIfODUkTcmFieldsInUse OBJECT-TYPE
 | 
						|
  SYNTAX  BITS {
 | 
						|
    tcmField1(0),
 | 
						|
    tcmField2(1),
 | 
						|
    tcmField3(2),
 | 
						|
    tcmField4(3),
 | 
						|
    tcmField5(4),
 | 
						|
    tcmField6(5)
 | 
						|
    }
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the TCM field(s) that are currently in use.
 | 
						|
     The positions of the bits correspond to the TCM fields.
 | 
						|
     A bit that is set to 1 means that the corresponding TCM
 | 
						|
     field is used.  This object will be updated when rows are
 | 
						|
     created in or deleted from the optIfODUkTConfigTable, or
 | 
						|
     the optIfODUkTNimConfigTable."
 | 
						|
  ::= { optIfODUkConfigEntry 3 }
 | 
						|
 | 
						|
optIfODUkPositionSeqCurrentSize OBJECT-TYPE
 | 
						|
  SYNTAX  Unsigned32
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "This variable indicates the current size of the position
 | 
						|
     sequence (i.e., number of TCM function and/or GCC12
 | 
						|
     access that have been created in the ODUk interface).
 | 
						|
     When the value of this variable is greater than zero,
 | 
						|
     it means that one or more TCM function and/or GCC12
 | 
						|
     access have been created in the ODUk interface.  In this
 | 
						|
     case, there will be as many rows in the
 | 
						|
     optIfODUkPositionSeqTable as the value of
 | 
						|
     optIfODUkPositionSeqCurrentSize  corresponding to this
 | 
						|
     ODUk interface, one row for each TCM function or GCC12
 | 
						|
     access.  The position of the TCM function and/or
 | 
						|
     GCC12 access within the sequence is indicated by the
 | 
						|
     optIfODUkPositionSeqPosition variable in
 | 
						|
     optIfODUkPositionSeqTable.
 | 
						|
     The optIfODUkPositionSeqTable also provides pointers
 | 
						|
     to the corresponding TCM function (optIfODUkT) and
 | 
						|
     GCC12 access (optIfGCC12) entities."
 | 
						|
  ::= { optIfODUkConfigEntry 4 }
 | 
						|
 | 
						|
optIfODUkTtpPresent OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "This object has the value true(1) if the ifEntry under which
 | 
						|
     it is instantiated contains an ODUk Trail Termination Point,
 | 
						|
     i.e., is the endpoint of an ODUk path.  In that case there
 | 
						|
     will be a corresponding row in the ODUk TTP config table and
 | 
						|
     it will not be possible to create corresponding rows in the
 | 
						|
     ODUk NIM config table.  This object has the value false(2)
 | 
						|
     if the ifEntry under which it is instantiated contains an
 | 
						|
     intermediate ODUk Connection Termination Point.  In that case
 | 
						|
     there is no corresponding row in the ODUk TTP config table,
 | 
						|
     but it will be possible to create corresponding rows in the
 | 
						|
     ODUk NIM config table.  This object also affects the allowable
 | 
						|
     options in rows created in the GCC12 config table and in the
 | 
						|
     ODUkT config table, as specified in the DESCRIPTION clauses
 | 
						|
     of the columns in those tables."
 | 
						|
  ::= { optIfODUkConfigEntry 5 }
 | 
						|
 | 
						|
-- ODUk Trail Termination Point (TTP) config table
 | 
						|
 | 
						|
optIfODUkTtpConfigTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfODUkTtpConfigEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of ODUk TTP configuration information."
 | 
						|
  ::= { optIfODUk 2 }
 | 
						|
 | 
						|
optIfODUkTtpConfigEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfODUkTtpConfigEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains ODUk TTP configuration
 | 
						|
     information of an interface."
 | 
						|
  INDEX  { ifIndex }
 | 
						|
  ::= { optIfODUkTtpConfigTable 1 }
 | 
						|
 | 
						|
OptIfODUkTtpConfigEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfODUkTtpTraceIdentifierTransmitted  OptIfTxTI,
 | 
						|
    optIfODUkTtpDAPIExpected                OptIfExDAPI,
 | 
						|
    optIfODUkTtpSAPIExpected                OptIfExSAPI,
 | 
						|
    optIfODUkTtpTraceIdentifierAccepted     OptIfAcTI,
 | 
						|
    optIfODUkTtpTIMDetMode                  OptIfTIMDetMode,
 | 
						|
    optIfODUkTtpTIMActEnabled               TruthValue,
 | 
						|
    optIfODUkTtpDEGThr                      OptIfDEGThr,
 | 
						|
    optIfODUkTtpDEGM                        OptIfDEGM,
 | 
						|
    optIfODUkTtpCurrentStatus               BITS
 | 
						|
    }
 | 
						|
 | 
						|
optIfODUkTtpTraceIdentifierTransmitted OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfTxTI
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The trace identifier transmitted.
 | 
						|
     This object is applicable when optIfODUkDirectionality
 | 
						|
     has the value source(2) or bidirectional(3).  It must not
 | 
						|
     be instantiated in rows where optIfODUkDirectionality
 | 
						|
     has the value sink(1).
 | 
						|
     If no value is ever set by a management entity for this
 | 
						|
     object, system-specific default value will be used.
 | 
						|
     Any implementation that instantiates this object must
 | 
						|
     document the system-specific default value or how it
 | 
						|
     is derived."
 | 
						|
  ::= { optIfODUkTtpConfigEntry 1 }
 | 
						|
 | 
						|
optIfODUkTtpDAPIExpected OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfExDAPI
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The DAPI expected by the receiver.
 | 
						|
     This object is only applicable to the sink function, i.e.,
 | 
						|
     only when optIfODUkDirectionality has the value sink(1)
 | 
						|
     or bidirectional(3).  It must not be instantiated in rows
 | 
						|
     where optIfODUkDirectionality has the value source(2).
 | 
						|
     This object has no effect when optIfODUkTtpTIMDetMode has
 | 
						|
     the value off(1)."
 | 
						|
  ::= { optIfODUkTtpConfigEntry 2 }
 | 
						|
 | 
						|
optIfODUkTtpSAPIExpected OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfExSAPI
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The SAPI expected by the receiver.
 | 
						|
     This object is only applicable to the sink function, i.e.,
 | 
						|
     only when optIfODUkDirectionality has the value sink(1)
 | 
						|
     or bidirectional(3).  It must not be instantiated in rows
 | 
						|
     where optIfODUkDirectionality has the value source(2).
 | 
						|
     This object has no effect when optIfODUkTtpTIMDetMode has
 | 
						|
     the value off(1)."
 | 
						|
  ::= { optIfODUkTtpConfigEntry 3 }
 | 
						|
 | 
						|
optIfODUkTtpTraceIdentifierAccepted OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfAcTI
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The actual trace identifier accepted.
 | 
						|
     This object is only applicable to the sink function, i.e.,
 | 
						|
     only when optIfODUkDirectionality has the value sink(1)
 | 
						|
     or bidirectional(3).  It must not be instantiated in rows
 | 
						|
     where optIfODUkDirectionality has the value source(2).
 | 
						|
     The value of this object is unspecified when
 | 
						|
     optIfODUkTtpCurrentStatus indicates a near-end defect
 | 
						|
     (i.e., oci(0), lck(1), ssf(5)) that prevents extraction
 | 
						|
     of the trace message."
 | 
						|
  ::= { optIfODUkTtpConfigEntry 4 }
 | 
						|
 | 
						|
optIfODUkTtpTIMDetMode OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfTIMDetMode
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the mode of the Trace Identifier Mismatch (TIM)
 | 
						|
     Detection function.
 | 
						|
     This object is only applicable to the sink function, i.e.,
 | 
						|
     only when optIfODUkDirectionality has the value sink(1)
 | 
						|
     or bidirectional(3).  It must not be instantiated in rows
 | 
						|
     where optIfODUkDirectionality has the value source(2).
 | 
						|
     The default value of this object is off(1)."
 | 
						|
  ::= { optIfODUkTtpConfigEntry 5 }
 | 
						|
 | 
						|
optIfODUkTtpTIMActEnabled OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates whether the Trace Identifier Mismatch (TIM)
 | 
						|
     Consequent Action function is enabled.
 | 
						|
     This object is only applicable to the sink function, i.e.,
 | 
						|
     only when optIfODUkDirectionality has the value sink(1)
 | 
						|
     or bidirectional(3).  It must not be instantiated in rows
 | 
						|
     where optIfODUkDirectionality has the value source(2).
 | 
						|
     This object has no effect when optIfODUkTtpTIMDetMode has
 | 
						|
     the value off(1).
 | 
						|
     The default value of this object is false(2)."
 | 
						|
  ::= { optIfODUkTtpConfigEntry 6 }
 | 
						|
 | 
						|
optIfODUkTtpDEGThr OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfDEGThr
 | 
						|
  UNITS   "percentage"
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the threshold level for declaring a performance
 | 
						|
     monitoring (PM) Second to be bad.  A PM Second is declared bad if
 | 
						|
     the percentage of detected errored blocks in that second is
 | 
						|
     greater than or equal to optIfODUkDEGThr.
 | 
						|
     This object is only applicable to the sink function, i.e.,
 | 
						|
     only when optIfODUkDirectionality has the value sink(1)
 | 
						|
     or bidirectional(3).  It must not be instantiated in rows
 | 
						|
     where optIfODUkDirectionality has the value source(2).
 | 
						|
     The default value of this object is Severely Errored Second
 | 
						|
     (SES) Estimator (See ITU-T G.7710)."
 | 
						|
  ::= { optIfODUkTtpConfigEntry 7 }
 | 
						|
 | 
						|
optIfODUkTtpDEGM OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfDEGM
 | 
						|
  MAX-ACCESS  read-write
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the threshold level for declaring a Degraded Signal
 | 
						|
     defect (dDEG).  A dDEG shall be declared if optIfODUkDEGM
 | 
						|
     consecutive bad PM Seconds are detected.
 | 
						|
     This object is only applicable to the sink function, i.e.,
 | 
						|
     only when optIfODUkDirectionality has the value sink(1)
 | 
						|
     or bidirectional(3).  It must not be instantiated in rows
 | 
						|
     where optIfODUkDirectionality has the value source(2).
 | 
						|
     The default value of this object is 7 (See ITU-T G.7710)."
 | 
						|
  ::= { optIfODUkTtpConfigEntry 8 }
 | 
						|
 | 
						|
optIfODUkTtpCurrentStatus OBJECT-TYPE
 | 
						|
  SYNTAX  BITS {
 | 
						|
    oci(0),
 | 
						|
    lck(1),
 | 
						|
    tim(2),
 | 
						|
    deg(3),
 | 
						|
    bdi(4),
 | 
						|
    ssf(5)
 | 
						|
    }
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the defect condition of the entity, if any.
 | 
						|
     This object is only applicable to the sink function, i.e.,
 | 
						|
     only when optIfODUkDirectionality has the value sink(1)
 | 
						|
     or bidirectional(3).  It must not be instantiated in rows
 | 
						|
     where optIfODUkDirectionality has the value source(2)."
 | 
						|
  ::= { optIfODUkTtpConfigEntry 9 }
 | 
						|
 | 
						|
-- ODUk Position Sequence table
 | 
						|
 | 
						|
optIfODUkPositionSeqTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfODUkPositionSeqEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of ODUk Position Sequence information."
 | 
						|
  ::= { optIfODUk 3 }
 | 
						|
 | 
						|
optIfODUkPositionSeqEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfODUkPositionSeqEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains ODUk position sequence
 | 
						|
     information of an ODUk interface.  The ODUk interface
 | 
						|
     is identified by the ifIndex.  Associated with each
 | 
						|
     ODUk interface there may be one of more conceptual
 | 
						|
     rows in the optIfODUkPositionSeqTable.  Each row
 | 
						|
     represents a TCM or GCC12 access function within the
 | 
						|
     associated ODUk interface.  Rows of the
 | 
						|
     optIfODUkPositionSeqTable table are created/deleted
 | 
						|
     as the result of the creation/deletion of the optIfODUkT
 | 
						|
     or optIfGCC12 entities."
 | 
						|
  INDEX  { ifIndex, optIfODUkPositionSeqIndex }
 | 
						|
  ::= { optIfODUkPositionSeqTable 1 }
 | 
						|
 | 
						|
OptIfODUkPositionSeqEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfODUkPositionSeqIndex            Unsigned32,
 | 
						|
    optIfODUkPositionSeqPosition         Unsigned32,
 | 
						|
    optIfODUkPositionSeqPointer          RowPointer
 | 
						|
    }
 | 
						|
 | 
						|
optIfODUkPositionSeqIndex OBJECT-TYPE
 | 
						|
  SYNTAX  Unsigned32 (1..4294967295)
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "This variable identifies a row in the
 | 
						|
     optIfODUkPositionSeqTable Table.
 | 
						|
     Each row of the optIfODUkPositionSeqTable Table
 | 
						|
     represents a TCM or GCC12 access function within the
 | 
						|
     associated ODUk interface."
 | 
						|
  ::= { optIfODUkPositionSeqEntry 1 }
 | 
						|
 | 
						|
optIfODUkPositionSeqPosition OBJECT-TYPE
 | 
						|
  SYNTAX  Unsigned32
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "This variable indicates the position of the TCM or
 | 
						|
     GCC12 access function within the sequence of TCMs &
 | 
						|
     GCC12 access functions of the associated ODUk
 | 
						|
     interface.  The TCM or GCC12 presented by this row is
 | 
						|
     referenced by the optIfODUkPositionSeqPointer variable."
 | 
						|
  ::= { optIfODUkPositionSeqEntry 2 }
 | 
						|
 | 
						|
optIfODUkPositionSeqPointer OBJECT-TYPE
 | 
						|
  SYNTAX  RowPointer
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "This variable identifies the TCM or GCC12 access function
 | 
						|
     by pointing to the corresponding optIfODUkT or optIfGCC12
 | 
						|
     entity."
 | 
						|
  ::= { optIfODUkPositionSeqEntry 3 }
 | 
						|
 | 
						|
-- ODUk Non-intrusive monitoring (Nim) config table
 | 
						|
 | 
						|
optIfODUkNimConfigTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfODUkNimConfigEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of ODUkNim configuration information."
 | 
						|
  ::= { optIfODUk 4 }
 | 
						|
 | 
						|
optIfODUkNimConfigEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfODUkNimConfigEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains ODUkNim configuration
 | 
						|
     information of an interface.  Each instance must
 | 
						|
     correspond to an instance of optIfODUkConfigEntry
 | 
						|
     for which optIfODUkTtpPresent has the value false(2).
 | 
						|
 | 
						|
     Instances of this conceptual row persist across
 | 
						|
     agent restarts, and read-create columns other
 | 
						|
     than the status column may be modified while the
 | 
						|
     row is active."
 | 
						|
  INDEX  { ifIndex, optIfODUkNimDirectionality }
 | 
						|
  ::= { optIfODUkNimConfigTable 1 }
 | 
						|
 | 
						|
OptIfODUkNimConfigEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfODUkNimDirectionality              OptIfSinkOrSource,
 | 
						|
    optIfODUkNimDAPIExpected                OptIfExDAPI,
 | 
						|
    optIfODUkNimSAPIExpected                OptIfExSAPI,
 | 
						|
    optIfODUkNimTraceIdentifierAccepted     OptIfAcTI,
 | 
						|
    optIfODUkNimTIMDetMode                  OptIfTIMDetMode,
 | 
						|
    optIfODUkNimTIMActEnabled               TruthValue,
 | 
						|
    optIfODUkNimDEGThr                      OptIfDEGThr,
 | 
						|
    optIfODUkNimDEGM                        OptIfDEGM,
 | 
						|
    optIfODUkNimCurrentStatus               BITS,
 | 
						|
    optIfODUkNimRowStatus                   RowStatus
 | 
						|
    }
 | 
						|
 | 
						|
optIfODUkNimDirectionality OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfSinkOrSource
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Specifies the monitor point for the ODUk Path non-intrusive
 | 
						|
     monitoring function.  The value source(2) is not allowed
 | 
						|
     if the corresponding instance of optIfODUkDirectionality
 | 
						|
     has the value sink(1), and the value sink(1) is not allowed
 | 
						|
     if the corresponding instance of optIfODUkDirectionality
 | 
						|
     has the value source(2).  Either the value sink(1) or
 | 
						|
     source(2) is allowed if the corresponding instance of
 | 
						|
     optIfODUkDirectionality has the value bidirectional(3).
 | 
						|
 | 
						|
     The value sink(1) means monitoring at the sink direction
 | 
						|
     path signal of the ODUk CTP.
 | 
						|
 | 
						|
     The value source(2) means monitoring at the source direction
 | 
						|
     path signal of the ODUk CTP.  Monitoring the source direction
 | 
						|
     of an ODUk CTP is necessary in those cases where the ODUk CTP
 | 
						|
     is at an SNCP (Subnetwork Connection Protection) end (e.g., see
 | 
						|
     Figure I.1.2/G.874.1).  If one would like to get the performance
 | 
						|
     of the protected connection, one cannot use the NIM function
 | 
						|
     at both ODUk CTP sinks (before the matrix), instead one should
 | 
						|
     monitor the signal at the source ODUk CTP after the matrix."
 | 
						|
  ::= { optIfODUkNimConfigEntry 1 }
 | 
						|
 | 
						|
optIfODUkNimDAPIExpected OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfExDAPI
 | 
						|
  MAX-ACCESS  read-create
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The DAPI expected by the receiver.
 | 
						|
     This object has no effect if optIfODUkNimTIMDetMode has
 | 
						|
     the value off(1) or sapi(3)."
 | 
						|
  ::= { optIfODUkNimConfigEntry 2 }
 | 
						|
 | 
						|
optIfODUkNimSAPIExpected OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfExSAPI
 | 
						|
  MAX-ACCESS  read-create
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The SAPI expected by the receiver.
 | 
						|
     This object has no effect if optIfODUkNimTIMDetMode has
 | 
						|
     the value off(1) or dapi(2)."
 | 
						|
  ::= { optIfODUkNimConfigEntry 3 }
 | 
						|
 | 
						|
optIfODUkNimTraceIdentifierAccepted OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfAcTI
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The actual trace identifier accepted.  The value of
 | 
						|
     this object is unspecified if optIfODUkNimCurrentStatus
 | 
						|
     has any of the bit positions oci(0), lck(1), or ssf(5)
 | 
						|
     set or if optIfODUkNimRowStatus has any value other
 | 
						|
     than active(1)."
 | 
						|
  ::= { optIfODUkNimConfigEntry 4 }
 | 
						|
 | 
						|
optIfODUkNimTIMDetMode OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfTIMDetMode
 | 
						|
  MAX-ACCESS  read-create
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the mode of the Trace Identifier Mismatch (TIM)
 | 
						|
     Detection function."
 | 
						|
  ::= { optIfODUkNimConfigEntry 5 }
 | 
						|
 | 
						|
optIfODUkNimTIMActEnabled OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-create
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates whether the Trace Identifier Mismatch (TIM)
 | 
						|
     Consequent Action function is enabled."
 | 
						|
  ::= { optIfODUkNimConfigEntry 6 }
 | 
						|
 | 
						|
optIfODUkNimDEGThr OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfDEGThr
 | 
						|
  UNITS   "percentage"
 | 
						|
  MAX-ACCESS  read-create
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the threshold level for declaring a performance
 | 
						|
     monitoring (PM) Second to be bad.  A PM Second is declared bad
 | 
						|
     if the percentage of detected errored blocks in that second is
 | 
						|
     greater than or equal to optIfODUkNimDEGThr."
 | 
						|
  ::= { optIfODUkNimConfigEntry 7 }
 | 
						|
 | 
						|
optIfODUkNimDEGM OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfDEGM
 | 
						|
  MAX-ACCESS  read-create
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the threshold level for declaring a Degraded Signal
 | 
						|
     defect (dDEG).  A dDEG shall be declared if optIfODUkNimDEGM
 | 
						|
     consecutive bad PM Seconds are detected."
 | 
						|
  ::= { optIfODUkNimConfigEntry 8 }
 | 
						|
 | 
						|
optIfODUkNimCurrentStatus OBJECT-TYPE
 | 
						|
  SYNTAX  BITS {
 | 
						|
    oci(0),
 | 
						|
    lck(1),
 | 
						|
    tim(2),
 | 
						|
    deg(3),
 | 
						|
    bdi(4),
 | 
						|
    ssf(5)
 | 
						|
    }
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the defect condition of the entity, if
 | 
						|
     any.  The value of this object is unspecified if
 | 
						|
     optIfODUkNimRowStatus has any value other than
 | 
						|
     active(1)."
 | 
						|
  ::= { optIfODUkNimConfigEntry 9 }
 | 
						|
 | 
						|
optIfODUkNimRowStatus OBJECT-TYPE
 | 
						|
  SYNTAX  RowStatus
 | 
						|
  MAX-ACCESS  read-create
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "This columnar object is used for creating and deleting
 | 
						|
     a conceptual row of the optIfODUkNim config table.
 | 
						|
     It is used to model the activateNim and deactivateNim
 | 
						|
     operations of an OTUk_CTP for non-intrusive monitoring
 | 
						|
     control as defined in G.874.1.  Setting RowStatus to
 | 
						|
     createAndGo or createAndWait implies activateNim.
 | 
						|
     Setting RowStatus to destroy implies deactivateNim."
 | 
						|
  ::= { optIfODUkNimConfigEntry 10 }
 | 
						|
 | 
						|
-- GCC12 config table
 | 
						|
 | 
						|
optIfGCC12ConfigTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfGCC12ConfigEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of GCC12 configuration information.
 | 
						|
     The GCC function processes the GCC overhead bytes passing
 | 
						|
     through them but leave the remainder of the ODUk overhead
 | 
						|
     and payload data alone."
 | 
						|
  ::= { optIfODUk 5 }
 | 
						|
 | 
						|
optIfGCC12ConfigEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfGCC12ConfigEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains GCC12 configuration
 | 
						|
     information of an interface.  Each instance must
 | 
						|
     correspond to an instance of optIfODUkConfigEntry.
 | 
						|
     Separate instances providing GCC1-only access and
 | 
						|
     GCC2-only access may exist for a given ifIndex value,
 | 
						|
     or a single instance providing GCC1 + GCC2 may exist,
 | 
						|
     but a GCC1 + GCC2 instance may not coexist with a
 | 
						|
     GCC1-only or GCC2-only instance.
 | 
						|
 | 
						|
     Instances of this conceptual row persist across agent
 | 
						|
     restarts."
 | 
						|
  INDEX  { ifIndex, optIfGCC12Codirectional, optIfGCC12GCCAccess }
 | 
						|
  ::= { optIfGCC12ConfigTable 1 }
 | 
						|
 | 
						|
 | 
						|
OptIfGCC12ConfigEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfGCC12Codirectional      TruthValue,
 | 
						|
    optIfGCC12GCCAccess          INTEGER,
 | 
						|
    optIfGCC12GCCPassThrough     TruthValue,
 | 
						|
    optIfGCC12Application        SnmpAdminString,
 | 
						|
    optIfGCC12RowStatus          RowStatus
 | 
						|
    }
 | 
						|
 | 
						|
optIfGCC12Codirectional OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the directionality of the GCC12 termination with
 | 
						|
     respect to the associated ODUk CTP.  The value true(1) means
 | 
						|
     that the sink part of the GCC12 extracts COMMS data from the
 | 
						|
     signal at the input to the ODUk CTP sink and the source part
 | 
						|
     of the GCC12 inserts COMMS data into the signal at the output
 | 
						|
     of the ODUk CTP source.  The value false(2) means that the
 | 
						|
     sink part of the GCC12 extracts COMMS data from the signal at
 | 
						|
     the output of the ODUk CTP source and the source part of the
 | 
						|
     GCC12 inserts COMMS data into the signal at the input of the
 | 
						|
     ODUk CTP sink.  This attribute may assume either value when
 | 
						|
     the corresponding instance of optIfODUkTtpPresent has the
 | 
						|
     value false(2).  When the value of the corresponding instance
 | 
						|
     of optIfODUkTtpPresent is true(1) then the only value allowed
 | 
						|
     for this attribute is true(1)."
 | 
						|
  ::= { optIfGCC12ConfigEntry 1 }
 | 
						|
 | 
						|
optIfGCC12GCCAccess OBJECT-TYPE
 | 
						|
  SYNTAX  INTEGER {
 | 
						|
     gcc1 (1),
 | 
						|
     gcc2 (2),
 | 
						|
     gcc1and2 (3)
 | 
						|
   }
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the GCC access represented by the entity."
 | 
						|
  ::= { optIfGCC12ConfigEntry 2 }
 | 
						|
 | 
						|
optIfGCC12GCCPassThrough OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-create
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Controls whether the selected GCC overhead bytes are passed
 | 
						|
     through or modified.  The value true(1) means that the selected
 | 
						|
     GCC overhead bytes are passed through unmodified from the ODUk
 | 
						|
     CTP input to the ODUk CTP output.  The value false(2) means that
 | 
						|
     the selected GCC overhead bytes are set to zero at the ODUk CTP
 | 
						|
     output after the extraction of the COMMS data.  This object has
 | 
						|
     no effect if the corresponding instance of optIfODUkTtpPresent
 | 
						|
     has the value true(1).
 | 
						|
 | 
						|
     The value of this object may not be changed when
 | 
						|
     optIfGCC12RowStatus has the value active(1)."
 | 
						|
  ::= { optIfGCC12ConfigEntry 3 }
 | 
						|
 | 
						|
optIfGCC12Application OBJECT-TYPE
 | 
						|
  SYNTAX  SnmpAdminString
 | 
						|
  MAX-ACCESS  read-create
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the application transported by the GCC12 entity.
 | 
						|
     Example applications are ECC, User data channel.
 | 
						|
 | 
						|
     The value of this object may not be changed when
 | 
						|
     optIfGCC12RowStatus has the value active(1)."
 | 
						|
  ::= { optIfGCC12ConfigEntry 4 }
 | 
						|
 | 
						|
optIfGCC12RowStatus OBJECT-TYPE
 | 
						|
  SYNTAX  RowStatus
 | 
						|
  MAX-ACCESS  read-create
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "This columnar object is used for creating and deleting
 | 
						|
     a conceptual row of the optIfGCC12 config table.  It is
 | 
						|
     used to model the addGCC12Access and removeGCC12Access
 | 
						|
     operations of an ODUk_CTP or ODUk_TTP for GCC12 access
 | 
						|
     control as defined in G.874.1.  Setting RowStatus to
 | 
						|
     createAndGo or createAndWait implies addGCC12Access.
 | 
						|
     Setting RowStatus to destroy implies removeGCC12Access.
 | 
						|
     Successful addition/removal of the GCC12 access function
 | 
						|
     will result in updating the
 | 
						|
     optIfODUkPositionSeqCurrentSize variable and the
 | 
						|
     optIfODUkPositionSeqTable table of the associated
 | 
						|
     ODUk entry in the optIfODUkConfigTable."
 | 
						|
  ::= { optIfGCC12ConfigEntry 5 }
 | 
						|
 | 
						|
-- the optIfODUkT group
 | 
						|
-- This group handles the configuration information
 | 
						|
-- for the ODUkT layers.
 | 
						|
 | 
						|
-- ODUkT config table
 | 
						|
 | 
						|
optIfODUkTConfigTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfODUkTConfigEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of ODUkT configuration information."
 | 
						|
  ::= { optIfODUkT 1 }
 | 
						|
 | 
						|
optIfODUkTConfigEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfODUkTConfigEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains ODUkT configuration
 | 
						|
     information of an interface.  Each instance must
 | 
						|
     correspond to an instance of optIfODUkConfigEntry.
 | 
						|
     Rows in this table are mutually exclusive with rows
 | 
						|
     in the ODUkT NIM config table -- in other words, this
 | 
						|
     row object may not be instantiated for a given pair
 | 
						|
     of ifIndex and TCM field values if a corresponding
 | 
						|
     instance of optIfODUkTNimConfigEntry already exists.
 | 
						|
 | 
						|
     Instances of this conceptual row persist across agent
 | 
						|
     restarts.  Except where noted otherwise, read-create
 | 
						|
     columns other than the status column may be modified
 | 
						|
     while the row is active."
 | 
						|
  INDEX  { ifIndex, optIfODUkTTcmField, optIfODUkTCodirectional }
 | 
						|
  ::= { optIfODUkTConfigTable 1 }
 | 
						|
 | 
						|
OptIfODUkTConfigEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfODUkTTcmField                    Unsigned32,
 | 
						|
    optIfODUkTCodirectional               TruthValue,
 | 
						|
    optIfODUkTTraceIdentifierTransmitted  OptIfTxTI,
 | 
						|
    optIfODUkTDAPIExpected                OptIfExDAPI,
 | 
						|
    optIfODUkTSAPIExpected                OptIfExSAPI,
 | 
						|
    optIfODUkTTraceIdentifierAccepted     OptIfAcTI,
 | 
						|
    optIfODUkTTIMDetMode                  OptIfTIMDetMode,
 | 
						|
    optIfODUkTTIMActEnabled               TruthValue,
 | 
						|
    optIfODUkTDEGThr                      OptIfDEGThr,
 | 
						|
    optIfODUkTDEGM                        OptIfDEGM,
 | 
						|
    optIfODUkTSinkMode                    INTEGER,
 | 
						|
    optIfODUkTSinkLockSignalAdminState    INTEGER,
 | 
						|
    optIfODUkTSourceLockSignalAdminState  INTEGER,
 | 
						|
    optIfODUkTCurrentStatus               BITS,
 | 
						|
    optIfODUkTRowStatus                   RowStatus
 | 
						|
    }
 | 
						|
 | 
						|
 | 
						|
optIfODUkTTcmField OBJECT-TYPE
 | 
						|
  SYNTAX  Unsigned32 (1..6)
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the tandem connection monitoring
 | 
						|
     field of the ODUk OH.  Valid values are
 | 
						|
     integers from 1 to 6."
 | 
						|
  ::= { optIfODUkTConfigEntry 1 }
 | 
						|
 | 
						|
optIfODUkTCodirectional OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the directionality of the ODUkT termination point with
 | 
						|
     respect to the associated ODUk CTP.  The value true(1) means
 | 
						|
     that the sink part of the ODUkT TP extracts TCM data from the
 | 
						|
     signal at the input to the ODUk CTP sink and the source part
 | 
						|
     of the ODUkT TP inserts TCM data into the signal at the output
 | 
						|
     of the ODUk CTP source.  The value false(2) means that the
 | 
						|
     sink part of the ODUkT TP extracts TCM data from the signal at
 | 
						|
     the output of the ODUk CTP source and the source part of the
 | 
						|
     ODUkT TP inserts TCM data into the signal at the input of the
 | 
						|
     ODUk CTP sink.  This attribute may assume either value when
 | 
						|
     the corresponding instance of optIfODUkTtpPresent has the
 | 
						|
     value false(2).  When the value of the corresponding instance
 | 
						|
     of optIfODUkTtpPresent is true(1) then the only value allowed
 | 
						|
     for this attribute is true(1)."
 | 
						|
  ::= { optIfODUkTConfigEntry 2 }
 | 
						|
 | 
						|
optIfODUkTTraceIdentifierTransmitted OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfTxTI
 | 
						|
  MAX-ACCESS  read-create
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The trace identifier transmitted.
 | 
						|
     This object is applicable only to the following three cases.
 | 
						|
       (i) optIfODUkDirectionality has the value bidirectional(3), or
 | 
						|
       (ii) optIfODUkDirectionality has the value sink(1) and
 | 
						|
            optIfODUkTCodirectional has the value false(2), or
 | 
						|
       (iii) optIfODUkDirectionality has the value source(3) and
 | 
						|
             optIfODUkTCodirectional has the value true(1).
 | 
						|
     It must not be instantiated in rows for all other cases."
 | 
						|
  ::= { optIfODUkTConfigEntry 3 }
 | 
						|
 | 
						|
optIfODUkTDAPIExpected OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfExDAPI
 | 
						|
  MAX-ACCESS  read-create
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The DAPI expected by the receiver.
 | 
						|
     This object is applicable only to the following three cases.
 | 
						|
       (i) optIfODUkDirectionality has the value bidirectional(3), or
 | 
						|
       (ii) optIfODUkDirectionality has the value sink(1) and
 | 
						|
            optIfODUkTCodirectional has the value true(1), or
 | 
						|
       (iii) optIfODUkDirectionality has the value source(3) and
 | 
						|
             optIfODUkTCodirectional has the value false(2).
 | 
						|
     It must not be instantiated in rows for all other cases.
 | 
						|
     This object has no effect when optIfODUkTTIMDetMode has
 | 
						|
     the value off(1)."
 | 
						|
  ::= { optIfODUkTConfigEntry 4 }
 | 
						|
 | 
						|
optIfODUkTSAPIExpected OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfExSAPI
 | 
						|
  MAX-ACCESS  read-create
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The SAPI expected by the receiver.
 | 
						|
     This object is applicable only to the following three cases.
 | 
						|
       (i) optIfODUkDirectionality has the value bidirectional(3), or
 | 
						|
       (ii) optIfODUkDirectionality has the value sink(1) and
 | 
						|
            optIfODUkTCodirectional has the value true(1), or
 | 
						|
       (iii) optIfODUkDirectionality has the value source(3) and
 | 
						|
             optIfODUkTCodirectional has the value false(2).
 | 
						|
     It must not be instantiated in rows for all other cases.
 | 
						|
     This object has no effect when optIfODUkTTIMDetMode has
 | 
						|
     the value off(1)."
 | 
						|
  ::= { optIfODUkTConfigEntry 5 }
 | 
						|
 | 
						|
optIfODUkTTraceIdentifierAccepted OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfAcTI
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The actual trace identifier accepted.
 | 
						|
     This object is applicable only to the following three cases.
 | 
						|
       (i) optIfODUkDirectionality has the value bidirectional(3), or
 | 
						|
       (ii) optIfODUkDirectionality has the value sink(1) and
 | 
						|
            optIfODUkTCodirectional has the value true(1), or
 | 
						|
       (iii) optIfODUkDirectionality has the value source(3) and
 | 
						|
             optIfODUkTCodirectional has the value false(2).
 | 
						|
     It must not be instantiated in rows for all other cases.
 | 
						|
     The value of this object is unspecified when
 | 
						|
     optIfODUkTCurrentStatus indicates a near-end defect
 | 
						|
     (i.e., oci(0), lck(1), ssf(5)) that prevents extraction
 | 
						|
     of the trace message."
 | 
						|
  ::= { optIfODUkTConfigEntry 6 }
 | 
						|
 | 
						|
optIfODUkTTIMDetMode OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfTIMDetMode
 | 
						|
  MAX-ACCESS  read-create
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the mode of the Trace Identifier Mismatch (TIM)
 | 
						|
     Detection function.
 | 
						|
     This object is applicable only to the following three cases.
 | 
						|
       (i) optIfODUkDirectionality has the value bidirectional(3), or
 | 
						|
       (ii) optIfODUkDirectionality has the value sink(1) and
 | 
						|
            optIfODUkTCodirectional has the value true(1), or
 | 
						|
       (iii) optIfODUkDirectionality has the value source(3) and
 | 
						|
             optIfODUkTCodirectional has the value false(2).
 | 
						|
     It must not be instantiated in rows for all other cases.
 | 
						|
     The default value of this object is off(1)."
 | 
						|
  ::= { optIfODUkTConfigEntry 7 }
 | 
						|
 | 
						|
optIfODUkTTIMActEnabled OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-create
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates whether the Trace Identifier Mismatch (TIM)
 | 
						|
     Consequent Action function is enabled.
 | 
						|
     This object is applicable only to the following three cases.
 | 
						|
       (i) optIfODUkDirectionality has the value bidirectional(3), or
 | 
						|
       (ii) optIfODUkDirectionality has the value sink(1) and
 | 
						|
            optIfODUkTCodirectional has the value true(1), or
 | 
						|
       (iii) optIfODUkDirectionality has the value source(3) and
 | 
						|
             optIfODUkTCodirectional has the value false(2).
 | 
						|
     It must not be instantiated in rows for all other cases.
 | 
						|
     This object has no effect when optIfODUkTTIMDetMode has
 | 
						|
     the value off(1).
 | 
						|
     The default value of this object is false(2)."
 | 
						|
  ::= { optIfODUkTConfigEntry 8 }
 | 
						|
 | 
						|
optIfODUkTDEGThr OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfDEGThr
 | 
						|
  UNITS   "percentage"
 | 
						|
  MAX-ACCESS  read-create
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the threshold level for declaring a performance
 | 
						|
     monitoring (PM) Second to be bad.  A PM Second is declared bad if
 | 
						|
     the percentage of detected errored blocks in that second is
 | 
						|
     greater than or equal to optIfODUkTDEGThr.
 | 
						|
     This object is applicable only to the following three cases.
 | 
						|
       (i) optIfODUkDirectionality has the value bidirectional(3), or
 | 
						|
       (ii) optIfODUkDirectionality has the value sink(1) and
 | 
						|
            optIfODUkTCodirectional has the value true(1), or
 | 
						|
       (iii) optIfODUkDirectionality has the value source(3) and
 | 
						|
             optIfODUkTCodirectional has the value false(2).
 | 
						|
     It must not be instantiated in rows for all other cases.
 | 
						|
     The default value of this object is Severely Errored Second
 | 
						|
     (SES) Estimator (See ITU-T G.7710)."
 | 
						|
  ::= { optIfODUkTConfigEntry 9 }
 | 
						|
 | 
						|
optIfODUkTDEGM OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfDEGM
 | 
						|
  MAX-ACCESS  read-create
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the threshold level for declaring a Degraded Signal
 | 
						|
     defect (dDEG).  A dDEG shall be declared if optIfODUkTDEGM
 | 
						|
     consecutive bad PM Seconds are detected.
 | 
						|
     This object is applicable only to the following three cases.
 | 
						|
       (i) optIfODUkDirectionality has the value bidirectional(3), or
 | 
						|
       (ii) optIfODUkDirectionality has the value sink(1) and
 | 
						|
            optIfODUkTCodirectional has the value true(1), or
 | 
						|
       (iii) optIfODUkDirectionality has the value source(3) and
 | 
						|
             optIfODUkTCodirectional has the value false(2).
 | 
						|
     It must not be instantiated in rows for all other cases.
 | 
						|
     The default value of this object is 7 (See ITU-T G.7710)."
 | 
						|
  ::= { optIfODUkTConfigEntry 10 }
 | 
						|
 | 
						|
optIfODUkTSinkMode OBJECT-TYPE
 | 
						|
  SYNTAX  INTEGER  {
 | 
						|
    operational (1),
 | 
						|
    monitor (2)
 | 
						|
    }
 | 
						|
  MAX-ACCESS  read-create
 | 
						|
  STATUS      current
 | 
						|
  DESCRIPTION
 | 
						|
    "This variable specifies the TCM mode at the entity.
 | 
						|
     The value operational(1) means that TCM Overhead (TCMOH)
 | 
						|
     processes (see ITU-T G.798) shall be
 | 
						|
     performed and consequent actions for AIS, Trail
 | 
						|
     Signal Fail (TSF), Trail Signal Degraded (TSD) shall be
 | 
						|
     initiated in case of defects.
 | 
						|
     The value monitor(2) means that TCMOH processes shall be
 | 
						|
     performed but consequent actions for AIS, Trail
 | 
						|
     Server Failure (TSF), Trail Server Degraded (TSD) shall _not_ be
 | 
						|
     initiated in case of defects.
 | 
						|
     This object is applicable only when the value of
 | 
						|
     optIfODUkTtpPresent is false(2) and also either one of the
 | 
						|
     following three cases holds:
 | 
						|
       (i) optIfODUkDirectionality has the value bidirectional(3), or
 | 
						|
       (ii) optIfODUkDirectionality has the value sink(1) and
 | 
						|
            optIfODUkTCodirectional has the value true(1), or
 | 
						|
       (iii) optIfODUkDirectionality has the value source(3) and
 | 
						|
             optIfODUkTCodirectional has the value false(2).
 | 
						|
     It must not be instantiated in rows for all other cases."
 | 
						|
  ::= { optIfODUkTConfigEntry 11 }
 | 
						|
 | 
						|
optIfODUkTSinkLockSignalAdminState OBJECT-TYPE
 | 
						|
  SYNTAX  INTEGER {
 | 
						|
    locked(1),
 | 
						|
    normal(2)
 | 
						|
    }
 | 
						|
  MAX-ACCESS  read-create
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Provides the capability to provision the LOCK signal, which
 | 
						|
     is one of the ODUk maintenance signals, at the ODUKT sink.  When
 | 
						|
     a Tandem Connection endpoint is set to admin state locked,
 | 
						|
     it inserts the ODUk-LCK signal in the sink direction.
 | 
						|
 | 
						|
     This object is applicable only when the value of
 | 
						|
     optIfODUkTtpPresent is false(2) and also either one of the
 | 
						|
     following three cases holds:
 | 
						|
       (i) optIfODUkDirectionality has the value bidirectional(3), or
 | 
						|
       (ii) optIfODUkDirectionality has the value sink(1) and
 | 
						|
            optIfODUkTCodirectional has the value true(1), or
 | 
						|
       (iii) optIfODUkDirectionality has the value source(3) and
 | 
						|
             optIfODUkTCodirectional has the value false(2).
 | 
						|
     It must not be instantiated in rows for all other cases."
 | 
						|
  ::= { optIfODUkTConfigEntry 12 }
 | 
						|
 | 
						|
optIfODUkTSourceLockSignalAdminState OBJECT-TYPE
 | 
						|
  SYNTAX  INTEGER {
 | 
						|
    locked(1),
 | 
						|
    normal(2)
 | 
						|
    }
 | 
						|
  MAX-ACCESS  read-create
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Provides the capability to provision the LOCK signal, which
 | 
						|
     is one of the ODUk maintenance signals, at the source.
 | 
						|
     When a Tandem Connection endpoint is set to admin state
 | 
						|
     locked, it inserts the ODUk-LCK signal in the source
 | 
						|
     direction.
 | 
						|
     This object is applicable only when either one of the
 | 
						|
     following three cases holds:
 | 
						|
       (i) optIfODUkDirectionality has the value bidirectional(3), or
 | 
						|
       (ii) optIfODUkDirectionality has the value sink(1) and
 | 
						|
            optIfODUkTCodirectional has the value false(2), or
 | 
						|
       (iii) optIfODUkDirectionality has the value source(3) and
 | 
						|
             optIfODUkTCodirectional has the value true(1).
 | 
						|
     It must not be instantiated in rows for all other cases."
 | 
						|
  ::= { optIfODUkTConfigEntry 13 }
 | 
						|
 | 
						|
optIfODUkTCurrentStatus OBJECT-TYPE
 | 
						|
  SYNTAX  BITS {
 | 
						|
    oci(0),
 | 
						|
    lck(1),
 | 
						|
    tim(2),
 | 
						|
    deg(3),
 | 
						|
    bdi(4),
 | 
						|
    ssf(5)
 | 
						|
    }
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the defect condition of the entity, if any.
 | 
						|
     This object is applicable only when either one of the
 | 
						|
     following three cases holds:
 | 
						|
       (i) optIfODUkDirectionality has the value bidirectional(3), or
 | 
						|
       (ii) optIfODUkDirectionality has the value sink(1) and
 | 
						|
            optIfODUkTCodirectional has the value true(1), or
 | 
						|
       (iii) optIfODUkDirectionality has the value source(3) and
 | 
						|
             optIfODUkTCodirectional has the value false(2).
 | 
						|
     It must not be instantiated in rows for all other cases."
 | 
						|
  ::= { optIfODUkTConfigEntry 14 }
 | 
						|
 | 
						|
optIfODUkTRowStatus OBJECT-TYPE
 | 
						|
  SYNTAX  RowStatus
 | 
						|
  MAX-ACCESS  read-create
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "This columnar object is used for creating and deleting a
 | 
						|
     conceptual row of the optIfODUkT config table.
 | 
						|
     It is used to model the addTCM and removeTCM operations of an
 | 
						|
     ODUk_CTP or ODUk_TTP for Tandem connection monitoring as defined
 | 
						|
     in ITU-T G.874.1.
 | 
						|
     Setting RowStatus to createAndGo or createAndWait implies addTCM.
 | 
						|
     Setting RowStatus to destroy implies removeTCM.
 | 
						|
     Successful addition/removal of TCM will result in updating the
 | 
						|
     optIfODUkTcmFieldsInUse and optIfODUkPositionSeqCurrentSize
 | 
						|
     variables and the optIfODUkPositionSeqTable table of the
 | 
						|
     associated ODUk entry in the optIfODUkConfigTable."
 | 
						|
  ::= { optIfODUkTConfigEntry 15 }
 | 
						|
 | 
						|
-- ODUkT Non-intrusive monitoring (Nim) config table
 | 
						|
 | 
						|
optIfODUkTNimConfigTable OBJECT-TYPE
 | 
						|
  SYNTAX  SEQUENCE OF OptIfODUkTNimConfigEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A table of ODUkTNim configuration information."
 | 
						|
  ::= { optIfODUkT 2 }
 | 
						|
 | 
						|
optIfODUkTNimConfigEntry OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfODUkTNimConfigEntry
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A conceptual row that contains ODUkTNim configuration
 | 
						|
     information of an interface.  Each instance must
 | 
						|
     correspond to an instance of optIfODUkConfigEntry.
 | 
						|
     Rows in this table are mutually exclusive with rows
 | 
						|
     in the ODUkT config table -- in other words, this
 | 
						|
     row object may not be instantiated for a given pair
 | 
						|
     of ifIndex and TCM field values if a corresponding
 | 
						|
     instance of optIfODUkTConfigEntry already exists.
 | 
						|
 | 
						|
     Instances of this conceptual row persist across
 | 
						|
     agent restarts, and read-create columns other
 | 
						|
     than the status column may be modified while the
 | 
						|
     row is active."
 | 
						|
  INDEX  {ifIndex, optIfODUkTNimTcmField, optIfODUkTNimDirectionality}
 | 
						|
  ::= { optIfODUkTNimConfigTable 1 }
 | 
						|
 | 
						|
OptIfODUkTNimConfigEntry ::=
 | 
						|
  SEQUENCE {
 | 
						|
    optIfODUkTNimTcmField                    Unsigned32,
 | 
						|
    optIfODUkTNimDirectionality              OptIfSinkOrSource,
 | 
						|
    optIfODUkTNimDAPIExpected                OptIfExDAPI,
 | 
						|
    optIfODUkTNimSAPIExpected                OptIfExSAPI,
 | 
						|
    optIfODUkTNimTraceIdentifierAccepted     OptIfAcTI,
 | 
						|
    optIfODUkTNimTIMDetMode                  OptIfTIMDetMode,
 | 
						|
    optIfODUkTNimTIMActEnabled               TruthValue,
 | 
						|
    optIfODUkTNimDEGThr                      OptIfDEGThr,
 | 
						|
    optIfODUkTNimDEGM                        OptIfDEGM,
 | 
						|
    optIfODUkTNimCurrentStatus               BITS,
 | 
						|
    optIfODUkTNimRowStatus                   RowStatus
 | 
						|
    }
 | 
						|
 | 
						|
optIfODUkTNimTcmField OBJECT-TYPE
 | 
						|
  SYNTAX  Unsigned32 (1..6)
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the tandem connection monitoring
 | 
						|
     field of the ODUk OH on which non-intrusive monitoring
 | 
						|
     is performed.  Valid values are
 | 
						|
     integers from 1 to 6."
 | 
						|
  ::= { optIfODUkTNimConfigEntry 1 }
 | 
						|
 | 
						|
optIfODUkTNimDirectionality OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfSinkOrSource
 | 
						|
  MAX-ACCESS  not-accessible
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Specifies the monitor point for the ODUk TCM non-intrusive
 | 
						|
     monitoring function.  The value source(2) is not allowed
 | 
						|
     if the corresponding instance of optIfODUkDirectionality
 | 
						|
     has the value sink(1), and the value sink(1) is not allowed
 | 
						|
     if the corresponding instance of optIfODUkDirectionality
 | 
						|
     has the value source(2).  Either the value sink(1) or
 | 
						|
     source(2) is allowed if the corresponding instance of
 | 
						|
     optIfODUkDirectionality has the value bidirectional(3).
 | 
						|
     The value sink(1) means monitoring at the sink direction
 | 
						|
     TCM signal of the ODUk CTP.
 | 
						|
     The value source(2) means monitoring at the source direction
 | 
						|
     path signal of the ODUk CTP."
 | 
						|
  ::= { optIfODUkTNimConfigEntry 2 }
 | 
						|
 | 
						|
optIfODUkTNimDAPIExpected OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfExDAPI
 | 
						|
  MAX-ACCESS  read-create
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The DAPI expected by the receiver.
 | 
						|
     This object has no effect if optIfODUkTNimTIMDetMode has
 | 
						|
     the value off(1) or sapi(3)."
 | 
						|
  ::= { optIfODUkTNimConfigEntry 3 }
 | 
						|
 | 
						|
optIfODUkTNimSAPIExpected OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfExSAPI
 | 
						|
  MAX-ACCESS  read-create
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The SAPI expected by the receiver.
 | 
						|
     This object has no effect if optIfODUkTNimTIMDetMode has
 | 
						|
     the value off(1) or dapi(2)."
 | 
						|
 | 
						|
  ::= { optIfODUkTNimConfigEntry 4 }
 | 
						|
 | 
						|
optIfODUkTNimTraceIdentifierAccepted OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfAcTI
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "The actual trace identifier accepted.  The value of
 | 
						|
     this object is unspecified if optIfODUkTNimCurrentStatus
 | 
						|
     has any of the bit positions oci(0), lck(1), or ssf(5)
 | 
						|
     set or if optIfODUkTNimRowStatus has any value other
 | 
						|
     than active(1)."
 | 
						|
  ::= { optIfODUkTNimConfigEntry 5 }
 | 
						|
 | 
						|
optIfODUkTNimTIMDetMode OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfTIMDetMode
 | 
						|
  MAX-ACCESS  read-create
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the mode of the Trace Identifier Mismatch (TIM)
 | 
						|
     Detection function."
 | 
						|
  ::= { optIfODUkTNimConfigEntry 6 }
 | 
						|
 | 
						|
optIfODUkTNimTIMActEnabled OBJECT-TYPE
 | 
						|
  SYNTAX  TruthValue
 | 
						|
  MAX-ACCESS  read-create
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates whether the Trace Identifier Mismatch (TIM)
 | 
						|
     Consequent Action function is enabled."
 | 
						|
  ::= { optIfODUkTNimConfigEntry 7 }
 | 
						|
 | 
						|
optIfODUkTNimDEGThr OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfDEGThr
 | 
						|
  UNITS   "percentage"
 | 
						|
  MAX-ACCESS  read-create
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the threshold level for declaring a performance
 | 
						|
     monitoring (PM) Second to be bad.  A PM Second is declared bad if
 | 
						|
     the percentage of detected errored blocks in that second is
 | 
						|
     greater than or equal to optIfODUkTNimDEGThr."
 | 
						|
  ::= { optIfODUkTNimConfigEntry 8 }
 | 
						|
 | 
						|
optIfODUkTNimDEGM OBJECT-TYPE
 | 
						|
  SYNTAX  OptIfDEGM
 | 
						|
  MAX-ACCESS  read-create
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the threshold level for declaring a Degraded Signal
 | 
						|
     defect (dDEG).  A dDEG shall be declared if optIfODUkTNimDEGM
 | 
						|
     consecutive bad PM Seconds are detected."
 | 
						|
  ::= { optIfODUkTNimConfigEntry 9 }
 | 
						|
 | 
						|
optIfODUkTNimCurrentStatus OBJECT-TYPE
 | 
						|
  SYNTAX  BITS {
 | 
						|
    oci(0),
 | 
						|
    lck(1),
 | 
						|
    tim(2),
 | 
						|
    deg(3),
 | 
						|
    bdi(4),
 | 
						|
    ssf(5)
 | 
						|
    }
 | 
						|
  MAX-ACCESS  read-only
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "Indicates the defect condition of the entity, if any.
 | 
						|
     The value of this object is unspecified if
 | 
						|
     optIfODUkTNimRowStatus has any value other than
 | 
						|
     active(1)."
 | 
						|
  ::= { optIfODUkTNimConfigEntry 10 }
 | 
						|
 | 
						|
optIfODUkTNimRowStatus OBJECT-TYPE
 | 
						|
  SYNTAX  RowStatus
 | 
						|
  MAX-ACCESS  read-create
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "This columnar object is used for creating and deleting a
 | 
						|
     conceptual row of the optIfODUkTNim config table.
 | 
						|
     It is used to model the addTCM and removeTCM operations of an
 | 
						|
     ODUk_CTP or ODUk_TTP for non-intrusive Tandem connection
 | 
						|
     monitoring as defined in ITU-T G.874.1.
 | 
						|
     Setting RowStatus to createAndGo or createAndWait implies addTCM.
 | 
						|
     Setting RowStatus to destroy implies removeTCM.
 | 
						|
     Successful addition/removal of Nim TCM will result in updating
 | 
						|
     the optIfODUkPositionSeqCurrentSize variable and the
 | 
						|
     optIfODUkPositionSeqTable table of the associated ODUk entry
 | 
						|
     in the optIfODUkConfigTable."
 | 
						|
  ::= { optIfODUkTNimConfigEntry 11 }
 | 
						|
 | 
						|
-- units of conformance
 | 
						|
 | 
						|
optIfOTMnGroup OBJECT-GROUP
 | 
						|
  OBJECTS  {
 | 
						|
    optIfOTMnOrder,
 | 
						|
    optIfOTMnReduced,
 | 
						|
    optIfOTMnBitRates,
 | 
						|
    optIfOTMnInterfaceType,
 | 
						|
    optIfOTMnTcmMax,
 | 
						|
    optIfOTMnOpticalReach
 | 
						|
    }
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A collection of OTMn structure information objects."
 | 
						|
  ::= { optIfGroups 1 }
 | 
						|
 | 
						|
optIfPerfMonGroup OBJECT-GROUP
 | 
						|
  OBJECTS  {
 | 
						|
    optIfPerfMonCurrentTimeElapsed,
 | 
						|
    optIfPerfMonCurDayTimeElapsed,
 | 
						|
    optIfPerfMonIntervalNumIntervals,
 | 
						|
    optIfPerfMonIntervalNumInvalidIntervals
 | 
						|
    }
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A collection of performance monitoring interval objects."
 | 
						|
  ::= { optIfGroups 2 }
 | 
						|
 | 
						|
optIfOTSnCommonGroup OBJECT-GROUP
 | 
						|
  OBJECTS  {
 | 
						|
    optIfOTSnDirectionality
 | 
						|
    }
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A collection of configuration objects
 | 
						|
     applicable to all OTSn interfaces."
 | 
						|
  ::= { optIfGroups 3 }
 | 
						|
 | 
						|
optIfOTSnSourceGroupFull OBJECT-GROUP
 | 
						|
  OBJECTS  {
 | 
						|
    optIfOTSnTraceIdentifierTransmitted
 | 
						|
    }
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A collection of configuration objects
 | 
						|
     applicable to full-functionality/IaDI OTSn
 | 
						|
     interfaces that support source functions."
 | 
						|
  ::= { optIfGroups 4 }
 | 
						|
 | 
						|
optIfOTSnAPRStatusGroup OBJECT-GROUP
 | 
						|
  OBJECTS  {
 | 
						|
    optIfOTSnAprStatus
 | 
						|
    }
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A collection of objects applicable to
 | 
						|
     OTSn interfaces that support Automatic
 | 
						|
     Power Reduction functions."
 | 
						|
  ::= { optIfGroups 5 }
 | 
						|
 | 
						|
optIfOTSnAPRControlGroup OBJECT-GROUP
 | 
						|
  OBJECTS  {
 | 
						|
    optIfOTSnAprControl
 | 
						|
    }
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A collection of objects applicable to
 | 
						|
     OTSn interfaces that provide Automatic
 | 
						|
     Power Reduction control functions."
 | 
						|
  ::= { optIfGroups 6 }
 | 
						|
 | 
						|
optIfOTSnSinkGroupBasic OBJECT-GROUP
 | 
						|
  OBJECTS  {
 | 
						|
    optIfOTSnCurrentStatus
 | 
						|
    }
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A collection of configuration objects
 | 
						|
     applicable to all OTSn interfaces that
 | 
						|
     support sink functions."
 | 
						|
  ::= { optIfGroups 7 }
 | 
						|
 | 
						|
optIfOTSnSinkGroupFull OBJECT-GROUP
 | 
						|
  OBJECTS  {
 | 
						|
    optIfOTSnDAPIExpected,
 | 
						|
    optIfOTSnSAPIExpected,
 | 
						|
    optIfOTSnTraceIdentifierAccepted,
 | 
						|
    optIfOTSnTIMDetMode,
 | 
						|
    optIfOTSnTIMActEnabled
 | 
						|
    }
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A collection of configuration objects
 | 
						|
     applicable to full-functionality/IaDI OTSn
 | 
						|
     interfaces that support sink functions."
 | 
						|
  ::= { optIfGroups 8 }
 | 
						|
 | 
						|
optIfOTSnSinkPreOtnPMGroup OBJECT-GROUP
 | 
						|
  OBJECTS  {
 | 
						|
    optIfOTSnSinkCurrentSuspectedFlag,
 | 
						|
    optIfOTSnSinkCurrentInputPower,
 | 
						|
    optIfOTSnSinkCurrentLowInputPower,
 | 
						|
    optIfOTSnSinkCurrentHighInputPower,
 | 
						|
    optIfOTSnSinkCurrentOutputPower,
 | 
						|
    optIfOTSnSinkCurrentLowOutputPower,
 | 
						|
    optIfOTSnSinkCurrentHighOutputPower,
 | 
						|
    optIfOTSnSinkIntervalSuspectedFlag,
 | 
						|
    optIfOTSnSinkIntervalLastInputPower,
 | 
						|
    optIfOTSnSinkIntervalLowInputPower,
 | 
						|
    optIfOTSnSinkIntervalHighInputPower,
 | 
						|
    optIfOTSnSinkIntervalLastOutputPower,
 | 
						|
    optIfOTSnSinkIntervalLowOutputPower,
 | 
						|
    optIfOTSnSinkIntervalHighOutputPower,
 | 
						|
    optIfOTSnSinkCurDaySuspectedFlag,
 | 
						|
    optIfOTSnSinkCurDayLowInputPower,
 | 
						|
    optIfOTSnSinkCurDayHighInputPower,
 | 
						|
    optIfOTSnSinkCurDayLowOutputPower,
 | 
						|
    optIfOTSnSinkCurDayHighOutputPower,
 | 
						|
    optIfOTSnSinkPrevDaySuspectedFlag,
 | 
						|
    optIfOTSnSinkPrevDayLastInputPower,
 | 
						|
    optIfOTSnSinkPrevDayLowInputPower,
 | 
						|
    optIfOTSnSinkPrevDayHighInputPower,
 | 
						|
    optIfOTSnSinkPrevDayLastOutputPower,
 | 
						|
    optIfOTSnSinkPrevDayLowOutputPower,
 | 
						|
    optIfOTSnSinkPrevDayHighOutputPower
 | 
						|
    }
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A collection of pre-OTN performance monitoring
 | 
						|
     objects applicable to OTSn interfaces that
 | 
						|
     support sink functions."
 | 
						|
  ::= { optIfGroups 9 }
 | 
						|
 | 
						|
optIfOTSnSinkPreOtnPMThresholdGroup OBJECT-GROUP
 | 
						|
  OBJECTS  {
 | 
						|
    optIfOTSnSinkCurrentLowerInputPowerThreshold,
 | 
						|
    optIfOTSnSinkCurrentUpperInputPowerThreshold,
 | 
						|
    optIfOTSnSinkCurrentLowerOutputPowerThreshold,
 | 
						|
    optIfOTSnSinkCurrentUpperOutputPowerThreshold
 | 
						|
    }
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A collection of pre-OTN performance monitoring
 | 
						|
     threshold objects applicable to OTSn interfaces
 | 
						|
     that support sink functions."
 | 
						|
  ::= { optIfGroups 10 }
 | 
						|
 | 
						|
optIfOTSnSourcePreOtnPMGroup OBJECT-GROUP
 | 
						|
  OBJECTS  {
 | 
						|
    optIfOTSnSrcCurrentSuspectedFlag,
 | 
						|
    optIfOTSnSrcCurrentOutputPower,
 | 
						|
    optIfOTSnSrcCurrentLowOutputPower,
 | 
						|
    optIfOTSnSrcCurrentHighOutputPower,
 | 
						|
    optIfOTSnSrcCurrentInputPower,
 | 
						|
    optIfOTSnSrcCurrentLowInputPower,
 | 
						|
    optIfOTSnSrcCurrentHighInputPower,
 | 
						|
    optIfOTSnSrcIntervalSuspectedFlag,
 | 
						|
    optIfOTSnSrcIntervalLastOutputPower,
 | 
						|
    optIfOTSnSrcIntervalLowOutputPower,
 | 
						|
    optIfOTSnSrcIntervalHighOutputPower,
 | 
						|
    optIfOTSnSrcIntervalLastInputPower,
 | 
						|
    optIfOTSnSrcIntervalLowInputPower,
 | 
						|
    optIfOTSnSrcIntervalHighInputPower,
 | 
						|
    optIfOTSnSrcCurDaySuspectedFlag,
 | 
						|
    optIfOTSnSrcCurDayLowOutputPower,
 | 
						|
    optIfOTSnSrcCurDayHighOutputPower,
 | 
						|
    optIfOTSnSrcCurDayLowInputPower,
 | 
						|
    optIfOTSnSrcCurDayHighInputPower,
 | 
						|
    optIfOTSnSrcPrevDaySuspectedFlag,
 | 
						|
    optIfOTSnSrcPrevDayLastOutputPower,
 | 
						|
    optIfOTSnSrcPrevDayLowOutputPower,
 | 
						|
    optIfOTSnSrcPrevDayHighOutputPower,
 | 
						|
    optIfOTSnSrcPrevDayLastInputPower,
 | 
						|
    optIfOTSnSrcPrevDayLowInputPower,
 | 
						|
    optIfOTSnSrcPrevDayHighInputPower
 | 
						|
    }
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A collection of pre-OTN performance monitoring
 | 
						|
     objects applicable to OTSn interfaces that
 | 
						|
     support source functions."
 | 
						|
  ::= { optIfGroups 11 }
 | 
						|
 | 
						|
optIfOTSnSourcePreOtnPMThresholdGroup OBJECT-GROUP
 | 
						|
  OBJECTS  {
 | 
						|
    optIfOTSnSrcCurrentLowerOutputPowerThreshold,
 | 
						|
    optIfOTSnSrcCurrentUpperOutputPowerThreshold,
 | 
						|
    optIfOTSnSrcCurrentLowerInputPowerThreshold,
 | 
						|
    optIfOTSnSrcCurrentUpperInputPowerThreshold
 | 
						|
    }
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A collection of pre-OTN performance monitoring
 | 
						|
     threshold objects applicable to OTSn interfaces
 | 
						|
     that support source functions."
 | 
						|
  ::= { optIfGroups 12 }
 | 
						|
 | 
						|
optIfOMSnCommonGroup OBJECT-GROUP
 | 
						|
  OBJECTS  {
 | 
						|
    optIfOMSnDirectionality
 | 
						|
    }
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A collection of configuration objects
 | 
						|
     applicable to all OMSn interfaces."
 | 
						|
  ::= { optIfGroups 13 }
 | 
						|
 | 
						|
optIfOMSnSinkGroupBasic OBJECT-GROUP
 | 
						|
  OBJECTS  {
 | 
						|
    optIfOMSnCurrentStatus
 | 
						|
    }
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A collection of configuration objects
 | 
						|
     applicable to all OMSn interfaces that
 | 
						|
     support sink functions."
 | 
						|
  ::= { optIfGroups 14 }
 | 
						|
 | 
						|
optIfOMSnSinkPreOtnPMGroup OBJECT-GROUP
 | 
						|
  OBJECTS  {
 | 
						|
    optIfOMSnSinkCurrentSuspectedFlag,
 | 
						|
    optIfOMSnSinkCurrentAggregatedInputPower,
 | 
						|
    optIfOMSnSinkCurrentLowAggregatedInputPower,
 | 
						|
    optIfOMSnSinkCurrentHighAggregatedInputPower,
 | 
						|
    optIfOMSnSinkCurrentOutputPower,
 | 
						|
    optIfOMSnSinkCurrentLowOutputPower,
 | 
						|
    optIfOMSnSinkCurrentHighOutputPower,
 | 
						|
    optIfOMSnSinkIntervalSuspectedFlag,
 | 
						|
    optIfOMSnSinkIntervalLastAggregatedInputPower,
 | 
						|
    optIfOMSnSinkIntervalLowAggregatedInputPower,
 | 
						|
    optIfOMSnSinkIntervalHighAggregatedInputPower,
 | 
						|
    optIfOMSnSinkIntervalLastOutputPower,
 | 
						|
    optIfOMSnSinkIntervalLowOutputPower,
 | 
						|
    optIfOMSnSinkIntervalHighOutputPower,
 | 
						|
    optIfOMSnSinkCurDaySuspectedFlag,
 | 
						|
    optIfOMSnSinkCurDayLowAggregatedInputPower,
 | 
						|
    optIfOMSnSinkCurDayHighAggregatedInputPower,
 | 
						|
    optIfOMSnSinkCurDayLowOutputPower,
 | 
						|
    optIfOMSnSinkCurDayHighOutputPower,
 | 
						|
    optIfOMSnSinkPrevDaySuspectedFlag,
 | 
						|
    optIfOMSnSinkPrevDayLastAggregatedInputPower,
 | 
						|
    optIfOMSnSinkPrevDayLowAggregatedInputPower,
 | 
						|
    optIfOMSnSinkPrevDayHighAggregatedInputPower,
 | 
						|
    optIfOMSnSinkPrevDayLastOutputPower,
 | 
						|
    optIfOMSnSinkPrevDayLowOutputPower,
 | 
						|
    optIfOMSnSinkPrevDayHighOutputPower
 | 
						|
    }
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A collection of pre-OTN performance monitoring
 | 
						|
     objects applicable to OMSn interfaces that
 | 
						|
     support sink functions."
 | 
						|
  ::= { optIfGroups 15 }
 | 
						|
 | 
						|
optIfOMSnSinkPreOtnPMThresholdGroup OBJECT-GROUP
 | 
						|
  OBJECTS  {
 | 
						|
    optIfOMSnSinkCurrentLowerInputPowerThreshold,
 | 
						|
    optIfOMSnSinkCurrentUpperInputPowerThreshold,
 | 
						|
    optIfOMSnSinkCurrentLowerOutputPowerThreshold,
 | 
						|
    optIfOMSnSinkCurrentUpperOutputPowerThreshold
 | 
						|
    }
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A collection of pre-OTN performance monitoring
 | 
						|
     threshold objects applicable to OMSn interfaces
 | 
						|
     that support sink functions."
 | 
						|
  ::= { optIfGroups 16 }
 | 
						|
 | 
						|
optIfOMSnSourcePreOtnPMGroup OBJECT-GROUP
 | 
						|
  OBJECTS  {
 | 
						|
    optIfOMSnSrcCurrentSuspectedFlag,
 | 
						|
    optIfOMSnSrcCurrentOutputPower,
 | 
						|
    optIfOMSnSrcCurrentLowOutputPower,
 | 
						|
    optIfOMSnSrcCurrentHighOutputPower,
 | 
						|
    optIfOMSnSrcCurrentAggregatedInputPower,
 | 
						|
    optIfOMSnSrcCurrentLowAggregatedInputPower,
 | 
						|
    optIfOMSnSrcCurrentHighAggregatedInputPower,
 | 
						|
    optIfOMSnSrcIntervalSuspectedFlag,
 | 
						|
    optIfOMSnSrcIntervalLastOutputPower,
 | 
						|
    optIfOMSnSrcIntervalLowOutputPower,
 | 
						|
    optIfOMSnSrcIntervalHighOutputPower,
 | 
						|
    optIfOMSnSrcIntervalLastAggregatedInputPower,
 | 
						|
    optIfOMSnSrcIntervalLowAggregatedInputPower,
 | 
						|
    optIfOMSnSrcIntervalHighAggregatedInputPower,
 | 
						|
    optIfOMSnSrcCurDaySuspectedFlag,
 | 
						|
    optIfOMSnSrcCurDayLowOutputPower,
 | 
						|
    optIfOMSnSrcCurDayHighOutputPower,
 | 
						|
    optIfOMSnSrcCurDayLowAggregatedInputPower,
 | 
						|
    optIfOMSnSrcCurDayHighAggregatedInputPower,
 | 
						|
    optIfOMSnSrcPrevDaySuspectedFlag,
 | 
						|
    optIfOMSnSrcPrevDayLastOutputPower,
 | 
						|
    optIfOMSnSrcPrevDayLowOutputPower,
 | 
						|
    optIfOMSnSrcPrevDayHighOutputPower,
 | 
						|
    optIfOMSnSrcPrevDayLastAggregatedInputPower,
 | 
						|
    optIfOMSnSrcPrevDayLowAggregatedInputPower,
 | 
						|
    optIfOMSnSrcPrevDayHighAggregatedInputPower
 | 
						|
    }
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A collection of pre-OTN performance monitoring
 | 
						|
     objects applicable to OMSn interfaces that
 | 
						|
     support source functions."
 | 
						|
  ::= { optIfGroups 17 }
 | 
						|
 | 
						|
optIfOMSnSourcePreOtnPMThresholdGroup OBJECT-GROUP
 | 
						|
  OBJECTS  {
 | 
						|
    optIfOMSnSrcCurrentLowerOutputPowerThreshold,
 | 
						|
    optIfOMSnSrcCurrentUpperOutputPowerThreshold,
 | 
						|
    optIfOMSnSrcCurrentLowerInputPowerThreshold,
 | 
						|
    optIfOMSnSrcCurrentUpperInputPowerThreshold
 | 
						|
    }
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A collection of pre-OTN performance monitoring
 | 
						|
     threshold objects applicable to OMSn interfaces that
 | 
						|
     that support source functions."
 | 
						|
  ::= { optIfGroups 18 }
 | 
						|
 | 
						|
optIfOChGroupCommonGroup OBJECT-GROUP
 | 
						|
  OBJECTS  {
 | 
						|
    optIfOChGroupDirectionality
 | 
						|
    }
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A collection of configuration objects
 | 
						|
     applicable to all OChGroup interfaces."
 | 
						|
  ::= { optIfGroups 19 }
 | 
						|
 | 
						|
optIfOChGroupSinkPreOtnPMGroup OBJECT-GROUP
 | 
						|
  OBJECTS  {
 | 
						|
    optIfOChGroupSinkCurrentSuspectedFlag,
 | 
						|
    optIfOChGroupSinkCurrentAggregatedInputPower,
 | 
						|
    optIfOChGroupSinkCurrentLowAggregatedInputPower,
 | 
						|
    optIfOChGroupSinkCurrentHighAggregatedInputPower,
 | 
						|
    optIfOChGroupSinkCurrentOutputPower,
 | 
						|
    optIfOChGroupSinkCurrentLowOutputPower,
 | 
						|
    optIfOChGroupSinkCurrentHighOutputPower,
 | 
						|
    optIfOChGroupSinkIntervalSuspectedFlag,
 | 
						|
    optIfOChGroupSinkIntervalLastAggregatedInputPower,
 | 
						|
    optIfOChGroupSinkIntervalLowAggregatedInputPower,
 | 
						|
    optIfOChGroupSinkIntervalHighAggregatedInputPower,
 | 
						|
    optIfOChGroupSinkIntervalLastOutputPower,
 | 
						|
    optIfOChGroupSinkIntervalLowOutputPower,
 | 
						|
    optIfOChGroupSinkIntervalHighOutputPower,
 | 
						|
    optIfOChGroupSinkCurDaySuspectedFlag,
 | 
						|
    optIfOChGroupSinkCurDayLowAggregatedInputPower,
 | 
						|
    optIfOChGroupSinkCurDayHighAggregatedInputPower,
 | 
						|
    optIfOChGroupSinkCurDayLowOutputPower,
 | 
						|
    optIfOChGroupSinkCurDayHighOutputPower,
 | 
						|
    optIfOChGroupSinkPrevDaySuspectedFlag,
 | 
						|
    optIfOChGroupSinkPrevDayLastAggregatedInputPower,
 | 
						|
    optIfOChGroupSinkPrevDayLowAggregatedInputPower,
 | 
						|
    optIfOChGroupSinkPrevDayHighAggregatedInputPower,
 | 
						|
    optIfOChGroupSinkPrevDayLastOutputPower,
 | 
						|
    optIfOChGroupSinkPrevDayLowOutputPower,
 | 
						|
    optIfOChGroupSinkPrevDayHighOutputPower
 | 
						|
    }
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A collection of pre-OTN performance monitoring
 | 
						|
     objects applicable to OChGroup interfaces that
 | 
						|
     support sink functions."
 | 
						|
  ::= { optIfGroups 20 }
 | 
						|
 | 
						|
optIfOChGroupSinkPreOtnPMThresholdGroup OBJECT-GROUP
 | 
						|
  OBJECTS  {
 | 
						|
    optIfOChGroupSinkCurrentLowerInputPowerThreshold,
 | 
						|
    optIfOChGroupSinkCurrentUpperInputPowerThreshold,
 | 
						|
    optIfOChGroupSinkCurrentLowerOutputPowerThreshold,
 | 
						|
    optIfOChGroupSinkCurrentUpperOutputPowerThreshold
 | 
						|
    }
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A collection of pre-OTN performance monitoring
 | 
						|
     threshold objects applicable to OChGroup interfaces
 | 
						|
     that support sink functions."
 | 
						|
  ::= { optIfGroups 21 }
 | 
						|
 | 
						|
optIfOChGroupSourcePreOtnPMGroup OBJECT-GROUP
 | 
						|
  OBJECTS  {
 | 
						|
    optIfOChGroupSrcCurrentSuspectedFlag,
 | 
						|
    optIfOChGroupSrcCurrentOutputPower,
 | 
						|
    optIfOChGroupSrcCurrentLowOutputPower,
 | 
						|
    optIfOChGroupSrcCurrentHighOutputPower,
 | 
						|
    optIfOChGroupSrcCurrentAggregatedInputPower,
 | 
						|
    optIfOChGroupSrcCurrentLowAggregatedInputPower,
 | 
						|
    optIfOChGroupSrcCurrentHighAggregatedInputPower,
 | 
						|
    optIfOChGroupSrcIntervalSuspectedFlag,
 | 
						|
    optIfOChGroupSrcIntervalLastOutputPower,
 | 
						|
    optIfOChGroupSrcIntervalLowOutputPower,
 | 
						|
    optIfOChGroupSrcIntervalHighOutputPower,
 | 
						|
    optIfOChGroupSrcIntervalLastAggregatedInputPower,
 | 
						|
    optIfOChGroupSrcIntervalLowAggregatedInputPower,
 | 
						|
    optIfOChGroupSrcIntervalHighAggregatedInputPower,
 | 
						|
    optIfOChGroupSrcCurDaySuspectedFlag,
 | 
						|
    optIfOChGroupSrcCurDayLowOutputPower,
 | 
						|
    optIfOChGroupSrcCurDayHighOutputPower,
 | 
						|
    optIfOChGroupSrcCurDayLowAggregatedInputPower,
 | 
						|
    optIfOChGroupSrcCurDayHighAggregatedInputPower,
 | 
						|
    optIfOChGroupSrcPrevDaySuspectedFlag,
 | 
						|
    optIfOChGroupSrcPrevDayLastOutputPower,
 | 
						|
    optIfOChGroupSrcPrevDayLowOutputPower,
 | 
						|
    optIfOChGroupSrcPrevDayHighOutputPower,
 | 
						|
    optIfOChGroupSrcPrevDayLastAggregatedInputPower,
 | 
						|
    optIfOChGroupSrcPrevDayLowAggregatedInputPower,
 | 
						|
    optIfOChGroupSrcPrevDayHighAggregatedInputPower
 | 
						|
    }
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A collection of pre-OTN performance monitoring
 | 
						|
     objects applicable to OChGroup interfaces that
 | 
						|
     support source functions."
 | 
						|
  ::= { optIfGroups 22 }
 | 
						|
 | 
						|
optIfOChGroupSourcePreOtnPMThresholdGroup OBJECT-GROUP
 | 
						|
  OBJECTS  {
 | 
						|
    optIfOChGroupSrcCurrentLowerOutputPowerThreshold,
 | 
						|
    optIfOChGroupSrcCurrentUpperOutputPowerThreshold,
 | 
						|
    optIfOChGroupSrcCurrentLowerInputPowerThreshold,
 | 
						|
    optIfOChGroupSrcCurrentUpperInputPowerThreshold
 | 
						|
    }
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A collection of pre-OTN performance monitoring
 | 
						|
     threshold objects applicable to OChGroup interfaces that
 | 
						|
     that support source functions."
 | 
						|
  ::= { optIfGroups 23 }
 | 
						|
 | 
						|
optIfOChCommonGroup OBJECT-GROUP
 | 
						|
  OBJECTS  {
 | 
						|
    optIfOChDirectionality
 | 
						|
    }
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A collection of configuration objects
 | 
						|
     applicable to all OCh interfaces."
 | 
						|
  ::= { optIfGroups 24 }
 | 
						|
 | 
						|
optIfOChSinkGroupBasic OBJECT-GROUP
 | 
						|
  OBJECTS  {
 | 
						|
    optIfOChCurrentStatus
 | 
						|
    }
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A collection of configuration objects
 | 
						|
     applicable to all OCh interfaces that
 | 
						|
     support sink functions."
 | 
						|
  ::= { optIfGroups 25 }
 | 
						|
 | 
						|
optIfOChSinkPreOtnPMGroup OBJECT-GROUP
 | 
						|
  OBJECTS  {
 | 
						|
    optIfOChSinkCurrentSuspectedFlag,
 | 
						|
    optIfOChSinkCurrentInputPower,
 | 
						|
    optIfOChSinkCurrentLowInputPower,
 | 
						|
    optIfOChSinkCurrentHighInputPower,
 | 
						|
    optIfOChSinkIntervalSuspectedFlag,
 | 
						|
    optIfOChSinkIntervalLastInputPower,
 | 
						|
    optIfOChSinkIntervalLowInputPower,
 | 
						|
    optIfOChSinkIntervalHighInputPower,
 | 
						|
    optIfOChSinkCurDaySuspectedFlag,
 | 
						|
    optIfOChSinkCurDayLowInputPower,
 | 
						|
    optIfOChSinkCurDayHighInputPower,
 | 
						|
    optIfOChSinkPrevDaySuspectedFlag,
 | 
						|
    optIfOChSinkPrevDayLastInputPower,
 | 
						|
    optIfOChSinkPrevDayLowInputPower,
 | 
						|
    optIfOChSinkPrevDayHighInputPower
 | 
						|
     }
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A collection of pre-OTN performance monitoring
 | 
						|
     objects applicable to OCh interfaces that
 | 
						|
     support sink functions."
 | 
						|
  ::= { optIfGroups 26 }
 | 
						|
 | 
						|
optIfOChSinkPreOtnPMThresholdGroup OBJECT-GROUP
 | 
						|
  OBJECTS  {
 | 
						|
    optIfOChSinkCurrentLowerInputPowerThreshold,
 | 
						|
    optIfOChSinkCurrentUpperInputPowerThreshold
 | 
						|
     }
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A collection of pre-OTN performance monitoring
 | 
						|
     threshold objects applicable to OCh interfaces
 | 
						|
     that support sink functions."
 | 
						|
  ::= { optIfGroups 27 }
 | 
						|
 | 
						|
 | 
						|
optIfOChSourcePreOtnPMGroup OBJECT-GROUP
 | 
						|
  OBJECTS  {
 | 
						|
    optIfOChSrcCurrentSuspectedFlag,
 | 
						|
    optIfOChSrcCurrentOutputPower,
 | 
						|
    optIfOChSrcCurrentLowOutputPower,
 | 
						|
    optIfOChSrcCurrentHighOutputPower,
 | 
						|
    optIfOChSrcIntervalSuspectedFlag,
 | 
						|
    optIfOChSrcIntervalLastOutputPower,
 | 
						|
    optIfOChSrcIntervalLowOutputPower,
 | 
						|
    optIfOChSrcIntervalHighOutputPower,
 | 
						|
    optIfOChSrcCurDaySuspectedFlag,
 | 
						|
    optIfOChSrcCurDayLowOutputPower,
 | 
						|
    optIfOChSrcCurDayHighOutputPower,
 | 
						|
    optIfOChSrcPrevDaySuspectedFlag,
 | 
						|
    optIfOChSrcPrevDayLastOutputPower,
 | 
						|
    optIfOChSrcPrevDayLowOutputPower,
 | 
						|
    optIfOChSrcPrevDayHighOutputPower
 | 
						|
     }
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A collection of pre-OTN performance monitoring
 | 
						|
     objects applicable to OCh interfaces that
 | 
						|
     support source functions."
 | 
						|
  ::= { optIfGroups 28 }
 | 
						|
 | 
						|
optIfOChSourcePreOtnPMThresholdGroup OBJECT-GROUP
 | 
						|
  OBJECTS  {
 | 
						|
    optIfOChSrcCurrentLowerOutputPowerThreshold,
 | 
						|
    optIfOChSrcCurrentUpperOutputPowerThreshold
 | 
						|
     }
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A collection of pre-OTN performance monitoring
 | 
						|
     threshold objects applicable to OCh interfaces
 | 
						|
     that support source functions."
 | 
						|
  ::= { optIfGroups 29 }
 | 
						|
 | 
						|
optIfOTUkCommonGroup OBJECT-GROUP
 | 
						|
  OBJECTS  {
 | 
						|
    optIfOTUkDirectionality,
 | 
						|
    optIfOTUkBitRateK
 | 
						|
    }
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A collection of configuration objects
 | 
						|
     applicable to all OTUk interfaces."
 | 
						|
  ::= { optIfGroups 30 }
 | 
						|
 | 
						|
optIfOTUkSourceGroup OBJECT-GROUP
 | 
						|
  OBJECTS  {
 | 
						|
    optIfOTUkTraceIdentifierTransmitted,
 | 
						|
    optIfOTUkSourceAdaptActive
 | 
						|
    }
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A collection of configuration objects
 | 
						|
     applicable to OTUk interfaces that
 | 
						|
     support source functions."
 | 
						|
  ::= { optIfGroups 31 }
 | 
						|
 | 
						|
optIfOTUkSinkGroup OBJECT-GROUP
 | 
						|
  OBJECTS  {
 | 
						|
    optIfOTUkDAPIExpected,
 | 
						|
    optIfOTUkSAPIExpected,
 | 
						|
    optIfOTUkTraceIdentifierAccepted,
 | 
						|
    optIfOTUkTIMDetMode,
 | 
						|
    optIfOTUkTIMActEnabled,
 | 
						|
    optIfOTUkDEGThr,
 | 
						|
    optIfOTUkDEGM,
 | 
						|
    optIfOTUkSinkAdaptActive,
 | 
						|
    optIfOTUkSinkFECEnabled,
 | 
						|
    optIfOTUkCurrentStatus
 | 
						|
    }
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A collection of configuration objects
 | 
						|
     applicable to OTUk interfaces that
 | 
						|
     support sink functions."
 | 
						|
  ::= { optIfGroups 32 }
 | 
						|
 | 
						|
optIfGCC0Group OBJECT-GROUP
 | 
						|
  OBJECTS  {
 | 
						|
    optIfGCC0Application,
 | 
						|
    optIfGCC0RowStatus
 | 
						|
    }
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A collection of GCC0 configuration objects."
 | 
						|
  ::= { optIfGroups 33 }
 | 
						|
 | 
						|
optIfODUkGroup OBJECT-GROUP
 | 
						|
  OBJECTS  {
 | 
						|
    optIfODUkDirectionality,
 | 
						|
    optIfODUkBitRateK,
 | 
						|
    optIfODUkTcmFieldsInUse,
 | 
						|
    optIfODUkPositionSeqCurrentSize,
 | 
						|
    optIfODUkPositionSeqPosition,
 | 
						|
    optIfODUkPositionSeqPointer,
 | 
						|
    optIfODUkTtpPresent
 | 
						|
    }
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A collection of configuration objects
 | 
						|
     applicable to all ODUk interfaces."
 | 
						|
  ::= { optIfGroups 34 }
 | 
						|
 | 
						|
optIfODUkTtpSourceGroup OBJECT-GROUP
 | 
						|
  OBJECTS  {
 | 
						|
    optIfODUkTtpTraceIdentifierTransmitted
 | 
						|
    }
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A collection of configuration objects
 | 
						|
     applicable to all interfaces that support
 | 
						|
     ODUk trail termination source functions."
 | 
						|
  ::= { optIfGroups 35 }
 | 
						|
 | 
						|
optIfODUkTtpSinkGroup OBJECT-GROUP
 | 
						|
  OBJECTS  {
 | 
						|
    optIfODUkTtpDAPIExpected,
 | 
						|
    optIfODUkTtpSAPIExpected,
 | 
						|
    optIfODUkTtpTraceIdentifierAccepted,
 | 
						|
    optIfODUkTtpTIMDetMode,
 | 
						|
    optIfODUkTtpTIMActEnabled,
 | 
						|
    optIfODUkTtpDEGThr,
 | 
						|
    optIfODUkTtpDEGM,
 | 
						|
    optIfODUkTtpCurrentStatus
 | 
						|
    }
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A collection of ODUk configuration objects
 | 
						|
     applicable to all interfaces that support
 | 
						|
     ODUk trail termination sink functions."
 | 
						|
  ::= { optIfGroups 36 }
 | 
						|
 | 
						|
optIfODUkNimGroup OBJECT-GROUP
 | 
						|
  OBJECTS  {
 | 
						|
    optIfODUkNimDAPIExpected,
 | 
						|
    optIfODUkNimSAPIExpected,
 | 
						|
    optIfODUkNimTraceIdentifierAccepted,
 | 
						|
    optIfODUkNimTIMDetMode,
 | 
						|
    optIfODUkNimTIMActEnabled,
 | 
						|
    optIfODUkNimDEGThr,
 | 
						|
    optIfODUkNimDEGM,
 | 
						|
    optIfODUkNimCurrentStatus,
 | 
						|
    optIfODUkNimRowStatus
 | 
						|
    }
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A collection of ODUk Nim configuration objects."
 | 
						|
  ::= { optIfGroups 37 }
 | 
						|
 | 
						|
optIfGCC12Group OBJECT-GROUP
 | 
						|
  OBJECTS  {
 | 
						|
    optIfGCC12GCCPassThrough,
 | 
						|
    optIfGCC12Application,
 | 
						|
    optIfGCC12RowStatus
 | 
						|
    }
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A collection of GCC12 configuration objects."
 | 
						|
  ::= { optIfGroups 38 }
 | 
						|
 | 
						|
optIfODUkTCommonGroup OBJECT-GROUP
 | 
						|
  OBJECTS  {
 | 
						|
    optIfODUkTRowStatus
 | 
						|
    }
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A collection of configuration objects
 | 
						|
     applicable to all ODUkT instances."
 | 
						|
  ::= { optIfGroups 39 }
 | 
						|
 | 
						|
optIfODUkTSourceGroup OBJECT-GROUP
 | 
						|
  OBJECTS  {
 | 
						|
    optIfODUkTTraceIdentifierTransmitted,
 | 
						|
    optIfODUkTSourceLockSignalAdminState
 | 
						|
    }
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A collection of configuration objects
 | 
						|
     applicable to all ODUkT instances
 | 
						|
     that provide source functions."
 | 
						|
  ::= { optIfGroups 40 }
 | 
						|
 | 
						|
optIfODUkTSinkGroup OBJECT-GROUP
 | 
						|
  OBJECTS  {
 | 
						|
    optIfODUkTDAPIExpected,
 | 
						|
    optIfODUkTSAPIExpected,
 | 
						|
    optIfODUkTTraceIdentifierAccepted,
 | 
						|
    optIfODUkTTIMDetMode,
 | 
						|
    optIfODUkTTIMActEnabled,
 | 
						|
    optIfODUkTDEGThr,
 | 
						|
    optIfODUkTDEGM,
 | 
						|
    optIfODUkTCurrentStatus
 | 
						|
    }
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A collection of configuration objects
 | 
						|
     applicable to all ODUkT instances
 | 
						|
     that provide sink functions."
 | 
						|
  ::= { optIfGroups 41 }
 | 
						|
 | 
						|
optIfODUkTSinkGroupCtp OBJECT-GROUP
 | 
						|
  OBJECTS  {
 | 
						|
    optIfODUkTSinkMode,
 | 
						|
    optIfODUkTSinkLockSignalAdminState
 | 
						|
    }
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A collection of configuration objects
 | 
						|
     applicable to ODUkT instances not
 | 
						|
     colocated with an ODUk TTP that
 | 
						|
     provide sink functions."
 | 
						|
  ::= { optIfGroups 42 }
 | 
						|
 | 
						|
optIfODUkTNimGroup OBJECT-GROUP
 | 
						|
  OBJECTS  {
 | 
						|
    optIfODUkTNimDAPIExpected,
 | 
						|
    optIfODUkTNimSAPIExpected,
 | 
						|
    optIfODUkTNimTraceIdentifierAccepted,
 | 
						|
    optIfODUkTNimTIMDetMode,
 | 
						|
    optIfODUkTNimTIMActEnabled,
 | 
						|
    optIfODUkTNimDEGThr,
 | 
						|
    optIfODUkTNimDEGM,
 | 
						|
    optIfODUkTNimCurrentStatus,
 | 
						|
    optIfODUkTNimRowStatus
 | 
						|
    }
 | 
						|
  STATUS  current
 | 
						|
  DESCRIPTION
 | 
						|
    "A collection of ODUkT Nim configuration objects."
 | 
						|
  ::= { optIfGroups 43 }
 | 
						|
 | 
						|
 | 
						|
END
 | 
						|
 |