Files
librenms-librenms/tests/data/fiberhome-switch.json
Tony Murray f2f169ae78 Modernize mempools (#12282)
* mempools to modern module
quick hacky hrstorage port

* port ucd-snmp-mib to Mempools

* Populate DB for ucd
Prep for yaml

* initial yaml attempt

* more complex conversions
fixes to YamlDiscovery, make leading $ optional and allow mib::oid format

* walk full tables and skip values
normalize percentages above 100

* handle precent only ones (specify total as 100)

* Move default polling out of YamlMempoolsDiscovery

* fixes

* Update test data hrstorage should be correct.

* perc_warn for hrstorage

* Host Resources, record buffer, cached, and shared

* Host Resources is always better, don't do both HR and UCD

* fix unix, include warning levels

* variable size

* consolidate skip_values

* define mempools schema

* number instead of integer

* more schema refactor

* one more skip_values reference

* throw error for invalid oid translation
aos6

* a*  and Cisco

* updated test data

* update almost all hrstorage data files

* b*

* c* with test data
use standard cache for hrStorage

* use cache for storage module too

* hand bsnmp properly

* bdcom

* exclude total oid from yaml so it is not polled
May add a way to ignore this behavior and poll it, but I don't know if that is needed.

* automatically handle percent only values

* ciscowlc

* only poll used or free if we have used, free, and total.

* fix skipping

* the dlinkoning
fix find value when value "name" is numeric

* support numeric oids

* dnos/ftos attempt

* I guess we can't filter on total > 0

* edgecos

* e*

* f WIP

* f*

* gwd (aka g*)

* h* + procurve

* i*

* j*

* m*

* support 0% used memory (however unlikely)

* n*

* CISCO-PROCESS-MIB memory, share cache with processors module

* ignore mempools with invalid total

* p*

* quanta

* r*
fix raisecom mibs terribly broken

* s-z

* style fixes

* Move VRP back to PHP and make it actually work

* fix zynos

* update schema

* Update Cisco processor data for description bug fixes

* fix comware processors

* comware mempools with memory size
default precision to 1

* sophos-xg updated data

* hrstorage use ram size for buffers, cache, and shared

* Show memory available instead of free in device overview

* UCD, use same rrd format, store available instead of free in the db.

* Calculate availability for HOST-RESOURCES-MIB

* Convert UCD to standard polling

* rename old rrd files

* initial graph work

* graph WIP

* Graph looking decent

* Graph looking decent for hr

* remove old ucd_graph code

* handle availability mempool
more graph cleanup

* color adjustments

* remove accidental free calculation

* Update test data and fix corner cases

* fis pfsense

* update schema

* add default value for mempool_class

* fix whitespace

* update schema

* update schema correctly

* one more time

* fortigate_1500d-sensors missing oids

* Update docs.

* fix indent

* add implements MempoolsDiscovery explicitly to OS

* remove ucd_memory graph references
remove unused device_memory graph

* remove unused functions

* set devices with mempools to rediscover to prevent/minimize gaps

* use a subquery

* add overview graph

* port health mempools table

* Update device mempool

* only show overview if multiple

* Don't override user set warn percentages in discovery

* fix missed usage

* fix style

* Safety check to not rename rrd files incorrectly if migration has not been run.

* Fix overview percent bar and represent available and used on the bar

* missed an item to convert to mempool_class

* percent on the wrong side
2020-11-23 15:35:35 -06:00

390 lines
16 KiB
JSON

{
"os": {
"discovery": {
"devices": [
{
"sysName": "<private>",
"sysObjectID": ".1.3.6.1.4.1.3807.1.582815",
"sysDescr": "S5800 FHN USP (R) Software, Version V210R240,Hw Version 2.0,Copyrig",
"sysContact": null,
"version": "V210R240",
"hardware": "S5800 FHN USP",
"features": "2.0",
"os": "fiberhome-switch",
"type": "network",
"serial": null,
"icon": "fiberhome.svg",
"location": "<private>"
}
]
},
"poller": {
"devices": [
{
"sysName": "<private>",
"sysObjectID": ".1.3.6.1.4.1.3807.1.582815",
"sysDescr": "S5800 FHN USP (R) Software, Version V210R240,Hw Version 2.0,Copyrig",
"sysContact": "<private>",
"version": "V210R240",
"hardware": "S5800 FHN USP",
"features": "2.0",
"os": "fiberhome-switch",
"type": "network",
"serial": null,
"icon": "fiberhome.svg",
"location": "<private>"
}
]
}
},
"sensors": {
"discovery": {
"sensors": [
{
"sensor_deleted": 0,
"sensor_class": "state",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.4.1.3807.1.8012.1.4.1.1.7.3222475008",
"sensor_index": "3222475008",
"sensor_type": "cpuStatus",
"sensor_descr": "CPU Status",
"group": null,
"sensor_divisor": 1,
"sensor_multiplier": 1,
"sensor_current": 0,
"sensor_limit": null,
"sensor_limit_warn": null,
"sensor_limit_low": null,
"sensor_limit_low_warn": null,
"sensor_alert": 1,
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": "cpuStatus"
},
{
"sensor_deleted": 0,
"sensor_class": "state",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.4.1.3807.1.8012.1.2.1.1.3.1611796736",
"sensor_index": "1611796736",
"sensor_type": "powerState",
"sensor_descr": "Supply Power-1/1",
"group": null,
"sensor_divisor": 1,
"sensor_multiplier": 1,
"sensor_current": 1,
"sensor_limit": null,
"sensor_limit_warn": null,
"sensor_limit_low": null,
"sensor_limit_low_warn": null,
"sensor_alert": 1,
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": "powerState"
},
{
"sensor_deleted": 0,
"sensor_class": "state",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.4.1.3807.1.8012.1.2.1.1.3.1612845312",
"sensor_index": "1612845312",
"sensor_type": "powerState",
"sensor_descr": "Supply Power-1/2",
"group": null,
"sensor_divisor": 1,
"sensor_multiplier": 1,
"sensor_current": 0,
"sensor_limit": null,
"sensor_limit_warn": null,
"sensor_limit_low": null,
"sensor_limit_low_warn": null,
"sensor_alert": 1,
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": "powerState"
},
{
"sensor_deleted": 0,
"sensor_class": "temperature",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.4.1.3807.1.8012.1.6.2.1.5.2148733184",
"sensor_index": "2148733184",
"sensor_type": "fiberhome-switch",
"sensor_descr": "Temper-1/0/1",
"group": null,
"sensor_divisor": 1,
"sensor_multiplier": 1,
"sensor_current": 36,
"sensor_limit": 80,
"sensor_limit_warn": null,
"sensor_limit_low": -10,
"sensor_limit_low_warn": null,
"sensor_alert": 1,
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": 0,
"sensor_class": "voltage",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.4.1.3807.1.8012.1.7.2.1.5.3759345920",
"sensor_index": "3759345920",
"sensor_type": "fiberhome-switch",
"sensor_descr": "Int. Voltage-1/0/1",
"group": null,
"sensor_divisor": 1000,
"sensor_multiplier": 1,
"sensor_current": 11.819,
"sensor_limit": 12.6,
"sensor_limit_warn": null,
"sensor_limit_low": 10.8,
"sensor_limit_low_warn": null,
"sensor_alert": 1,
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": 0,
"sensor_class": "voltage",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.4.1.3807.1.8012.1.7.2.1.5.3760394496",
"sensor_index": "3760394496",
"sensor_type": "fiberhome-switch",
"sensor_descr": "Int. Voltage-1/0/2",
"group": null,
"sensor_divisor": 1000,
"sensor_multiplier": 1,
"sensor_current": 0.998,
"sensor_limit": 1.05,
"sensor_limit_warn": null,
"sensor_limit_low": 0.95,
"sensor_limit_low_warn": null,
"sensor_alert": 1,
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": 0,
"sensor_class": "voltage",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.4.1.3807.1.8012.1.7.2.1.5.3761443072",
"sensor_index": "3761443072",
"sensor_type": "fiberhome-switch",
"sensor_descr": "Int. Voltage-1/0/3",
"group": null,
"sensor_divisor": 1000,
"sensor_multiplier": 1,
"sensor_current": 3.264,
"sensor_limit": 3.465,
"sensor_limit_warn": null,
"sensor_limit_low": 3.135,
"sensor_limit_low_warn": null,
"sensor_alert": 1,
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": 0,
"sensor_class": "voltage",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.4.1.3807.1.8012.1.7.2.1.5.3762491648",
"sensor_index": "3762491648",
"sensor_type": "fiberhome-switch",
"sensor_descr": "Int. Voltage-1/0/4",
"group": null,
"sensor_divisor": 1000,
"sensor_multiplier": 1,
"sensor_current": 2.56,
"sensor_limit": 2.625,
"sensor_limit_warn": null,
"sensor_limit_low": 2.475,
"sensor_limit_low_warn": null,
"sensor_alert": 1,
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": 0,
"sensor_class": "voltage",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.4.1.3807.1.8012.1.7.2.1.5.3763540224",
"sensor_index": "3763540224",
"sensor_type": "fiberhome-switch",
"sensor_descr": "Int. Voltage-1/0/5",
"group": null,
"sensor_divisor": 1000,
"sensor_multiplier": 1,
"sensor_current": 1.792,
"sensor_limit": 1.89,
"sensor_limit_warn": null,
"sensor_limit_low": 1.71,
"sensor_limit_low_warn": null,
"sensor_alert": 1,
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": 0,
"sensor_class": "voltage",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.4.1.3807.1.8012.1.7.2.1.5.3764588800",
"sensor_index": "3764588800",
"sensor_type": "fiberhome-switch",
"sensor_descr": "Int. Voltage-1/0/6",
"group": null,
"sensor_divisor": 1000,
"sensor_multiplier": 1,
"sensor_current": 1.19,
"sensor_limit": 1.26,
"sensor_limit_warn": null,
"sensor_limit_low": 1.14,
"sensor_limit_low_warn": null,
"sensor_alert": 1,
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
}
],
"state_indexes": [
{
"state_name": "cpuStatus",
"state_descr": "Normal",
"state_draw_graph": 0,
"state_value": 0,
"state_generic_value": 0
},
{
"state_name": "cpuStatus",
"state_descr": "Overflow",
"state_draw_graph": 0,
"state_value": 1,
"state_generic_value": 2
},
{
"state_name": "powerState",
"state_descr": "Normal",
"state_draw_graph": 0,
"state_value": 0,
"state_generic_value": 0
},
{
"state_name": "powerState",
"state_descr": "Insufficient",
"state_draw_graph": 0,
"state_value": 1,
"state_generic_value": 2
},
{
"state_name": "powerState",
"state_descr": "Overload",
"state_draw_graph": 0,
"state_value": 2,
"state_generic_value": 2
}
]
},
"poller": "matches discovery"
},
"mempools": {
"discovery": {
"mempools": [
{
"mempool_index": "3490910464",
"entPhysicalIndex": null,
"mempool_type": "fiberhome-switch",
"mempool_class": "system",
"mempool_precision": 1,
"mempool_descr": "Memory-1/0/1",
"mempool_perc": 74,
"mempool_perc_oid": null,
"mempool_used": 65502560,
"mempool_used_oid": ".1.3.6.1.4.1.3807.1.8012.1.5.4.1.7.3490910464",
"mempool_free": 23090592,
"mempool_free_oid": null,
"mempool_total": 88593152,
"mempool_total_oid": null,
"mempool_largestfree": null,
"mempool_lowestfree": null,
"mempool_deleted": 0,
"mempool_perc_warn": 90
},
{
"mempool_index": "3491959040",
"entPhysicalIndex": null,
"mempool_type": "fiberhome-switch",
"mempool_class": "system",
"mempool_precision": 1,
"mempool_descr": "Memory-1/0/2",
"mempool_perc": 67,
"mempool_perc_oid": null,
"mempool_used": 89771840,
"mempool_used_oid": ".1.3.6.1.4.1.3807.1.8012.1.5.4.1.7.3491959040",
"mempool_free": 44445888,
"mempool_free_oid": null,
"mempool_total": 134217728,
"mempool_total_oid": null,
"mempool_largestfree": null,
"mempool_lowestfree": null,
"mempool_deleted": 0,
"mempool_perc_warn": 90
}
]
},
"poller": "matches discovery"
},
"processors": {
"discovery": {
"processors": [
{
"entPhysicalIndex": 0,
"hrDeviceIndex": 0,
"processor_oid": ".1.3.6.1.4.1.3807.1.8012.1.4.1.1.2.3222475008",
"processor_index": "3222475008",
"processor_type": "fiberhome-switch",
"processor_usage": 8,
"processor_descr": "Cpu-1/0/1",
"processor_precision": 100,
"processor_perc_warn": 75
}
]
},
"poller": "matches discovery"
}
}