"os": {
"discovery": {
"devices": [
{
"sysName": "<private>",
"sysObjectID": ".1.3.6.1.4.1.4413",
"sysDescr": "EdgeSwitch 24-Port 250W, 1.0.1.4720839, Linux 3.6.5-f4a26ed5",
"sysContact": null,
"version": null,
"hardware": null,
"features": null,
"location": null,
"os": "edgeswitch",
"type": "network",
"serial": null,
"icon": "ubiquiti.svg"
}
]
},
"poller": {
"devices": [
{
"sysName": "<private>",
"sysObjectID": ".1.3.6.1.4.1.4413",
"sysDescr": "EdgeSwitch 24-Port 250W, 1.0.1.4720839, Linux 3.6.5-f4a26ed5",
"sysContact": "<private>",
"version": "1.0.1.4720839",
"hardware": "EdgeSwitch 24-Port 250W",
"features": null,
"location": "<private>",
"os": "edgeswitch",
"type": "network",
"serial": null,
"icon": "ubiquiti.svg"
}
]
}
},
"processors": {
"discovery": {
"processors": [
{
"entPhysicalIndex": 0,
"hrDeviceIndex": 0,
"processor_oid": ".1.3.6.1.4.1.4413.1.1.1.1.4.9.0",
"processor_index": "0",
"processor_type": "edgeswitch",
"processor_usage": 96,
"processor_descr": "Processor",
"processor_precision": 1,
"processor_perc_warn": 75
}
]
},
"poller": "matches discovery"
},
"sensors": {
"discovery": {
"sensors": [
{
"sensor_deleted": 0,
"sensor_class": "state",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.4.1.4413.1.1.43.1.15.1.2.1",
"sensor_index": "boxServicesTempUnitState.1",
"sensor_type": "boxServicesTempUnitEntry",
"sensor_descr": "Chassis state",
"sensor_divisor": 1,
"sensor_multiplier": 1,
"sensor_current": 1,
"sensor_limit": null,
"sensor_limit_warn": null,
"sensor_limit_low": null,
"sensor_limit_low_warn": null,
"sensor_alert": 1,
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": "boxServicesTempUnitEntry"
},
{
"sensor_deleted": 0,
"sensor_class": "temperature",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.4.1.4413.1.1.43.1.8.1.5.1.0",
"sensor_index": "boxServicesTempSensorTemperature.1.0",
"sensor_type": "edgeswitch",
"sensor_descr": "Temperature 1.0",
"sensor_divisor": 1,
"sensor_multiplier": 1,
"sensor_current": 70,
"sensor_limit": 90,
"sensor_limit_warn": null,
"sensor_limit_low": 60,
"sensor_limit_low_warn": null,
"sensor_alert": 1,
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": 0,
"sensor_class": "temperature",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.4.1.4413.1.1.43.1.8.1.5.1.1",
"sensor_index": "boxServicesTempSensorTemperature.1.1",
"sensor_type": "edgeswitch",
"sensor_descr": "Temperature 1.1",
"sensor_divisor": 1,
"sensor_multiplier": 1,
"sensor_current": 59,
"sensor_limit": 79,
"sensor_limit_warn": null,
"sensor_limit_low": 49,
"sensor_limit_low_warn": null,
"sensor_alert": 1,
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": 0,
"sensor_class": "temperature",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.4.1.4413.1.1.43.1.8.1.5.1.2",
"sensor_index": "boxServicesTempSensorTemperature.1.2",
"sensor_type": "edgeswitch",
"sensor_descr": "Temperature 1.2",
"sensor_divisor": 1,
"sensor_multiplier": 1,
"sensor_current": 66,
"sensor_limit": 86,
"sensor_limit_warn": null,
"sensor_limit_low": 56,
"sensor_limit_low_warn": null,
"sensor_alert": 1,
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
},
{
"sensor_deleted": 0,
"sensor_class": "temperature",
"poller_type": "snmp",
"sensor_oid": ".1.3.6.1.4.1.4413.1.1.43.1.8.1.5.1.3",
"sensor_index": "boxServicesTempSensorTemperature.1.3",
"sensor_type": "edgeswitch",
"sensor_descr": "Temperature 1.3",
"sensor_divisor": 1,
"sensor_multiplier": 1,
"sensor_current": 66,
"sensor_limit": 86,
"sensor_limit_warn": null,
"sensor_limit_low": 56,
"sensor_limit_low_warn": null,
"sensor_alert": 1,
"sensor_custom": "No",
"entPhysicalIndex": null,
"entPhysicalIndex_measured": null,
"sensor_prev": null,
"user_func": null,
"state_name": null
}
],
"state_indexes": [
{
"state_name": "boxServicesTempUnitEntry",
"state_descr": "low",
"state_draw_graph": 1,
"state_value": 0,
"state_generic_value": 1
},
{
"state_name": "boxServicesTempUnitEntry",
"state_descr": "normal",
"state_draw_graph": 1,
"state_value": 1,
"state_generic_value": 0
},
{
"state_name": "boxServicesTempUnitEntry",
"state_descr": "warning",
"state_draw_graph": 1,
"state_value": 2,
"state_generic_value": 1
},
{
"state_name": "boxServicesTempUnitEntry",
"state_descr": "critical",
"state_draw_graph": 1,
"state_value": 3,
"state_generic_value": 2
},
{
"state_name": "boxServicesTempUnitEntry",
"state_descr": "shutdown",
"state_draw_graph": 1,
"state_value": 4,
"state_generic_value": 2
},
{
"state_name": "boxServicesTempUnitEntry",
"state_descr": "notpresent",
"state_draw_graph": 1,
"state_value": 5,
"state_generic_value": 3
},
{
"state_name": "boxServicesTempUnitEntry",
"state_descr": "notoperational",
"state_draw_graph": 1,
"state_value": 6,
"state_generic_value": 2
}
]
},
"poller": "matches discovery"
}
}