CYCLADES-ACS-PM-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
cyACSMgmt
|
|
FROM CYCLADES-ACS-MIB
|
|
OBJECT-TYPE, MODULE-IDENTITY, Integer32
|
|
FROM SNMPv2-SMI
|
|
InterfaceIndex, InterfaceIndexOrZero
|
|
FROM IF-MIB
|
|
DisplayString
|
|
FROM SNMPv2-TC;
|
|
|
|
cyPM MODULE-IDENTITY
|
|
LAST-UPDATED "200508290000Z"
|
|
ORGANIZATION "Cyclades Corporation"
|
|
CONTACT-INFO "postal : Cyclades Corporation
|
|
3541 Gateway Boulevard
|
|
Fremont, CA 94538, USA
|
|
e-mail : Technical Support
|
|
support@cyclades.com"
|
|
DESCRIPTION "This module defines objects of the Proxy for PM "
|
|
REVISION "200508290000Z"
|
|
DESCRIPTION "Changed the Contact-Info"
|
|
REVISION "200310170000Z"
|
|
DESCRIPTION "First Draft"
|
|
::= { cyACSMgmt 5 }
|
|
|
|
cyNumberOfPM OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The total number of PM's connected on the unit"
|
|
::= { cyPM 1 }
|
|
|
|
cyPMTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CyPMEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Allows to read information about each connected PM"
|
|
::= { cyPM 2 }
|
|
|
|
cyPMEntry OBJECT-TYPE
|
|
SYNTAX CyPMEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Information about the connected PM"
|
|
INDEX { cyPMSerialPortNumber }
|
|
::= { cyPMTable 1 }
|
|
|
|
CyPMEntry ::= SEQUENCE {
|
|
cyPMSerialPortNumber InterfaceIndex,
|
|
cyPMNumberOutlets Integer32,
|
|
cyPMNumberUnits Integer32,
|
|
cyPMCurrent DisplayString,
|
|
cyPMVersion DisplayString,
|
|
cyPMTemperature DisplayString,
|
|
cyPMCommand DisplayString
|
|
}
|
|
|
|
cyPMSerialPortNumber OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of the serial port when the PM is connected."
|
|
::= { cyPMEntry 1 }
|
|
|
|
cyPMNumberOutlets OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Number of outlets."
|
|
::= { cyPMEntry 2 }
|
|
|
|
cyPMNumberUnits OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Total number of PM unists that are accessed by this
|
|
serial port."
|
|
::= { cyPMEntry 3 }
|
|
|
|
cyPMCurrent OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current reading for the PM."
|
|
::= { cyPMEntry 4 }
|
|
|
|
cyPMVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The software version of the PM."
|
|
::= { cyPMEntry 5 }
|
|
|
|
cyPMTemperature OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The PM temperature."
|
|
::= { cyPMEntry 6 }
|
|
|
|
cyPMCommand OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..100))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "A character string for the user to send commands to
|
|
PM. He can use it to does the save command.
|
|
Or to list the outlets that need to be turned off,
|
|
or turned on , or cycled or locked or unlocked as a
|
|
group. The command is the first word and is followed
|
|
by a space and the outlet list (otulets commands).
|
|
Valid commands are 'on', 'off', 'cycle', 'lock',
|
|
'unlock', 'save'."
|
|
::= { cyPMEntry 7 }
|
|
|
|
cyPMUnitTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CyPMUnitEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Allow operations on specific PM unit connected"
|
|
::= { cyPM 3 }
|
|
|
|
cyPMUnitEntry OBJECT-TYPE
|
|
SYNTAX CyPMUnitEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Allow operations on outlet"
|
|
INDEX { cyPMSerialPortNumber, cyPMUnitNumber }
|
|
::= { cyPMUnitTable 1 }
|
|
|
|
CyPMUnitEntry ::= SEQUENCE {
|
|
cyPMUnitNumber InterfaceIndex,
|
|
cyPMUnitVersion DisplayString,
|
|
cyPMUnitOutlets Integer32,
|
|
cyPMUnitFirstOutlet Integer32,
|
|
cyPMUnitCurrent Integer32,
|
|
cyPMUnitMaxCurrent Integer32,
|
|
cyPMUnitTemperature Integer32,
|
|
cyPMUnitMaxTemperature Integer32
|
|
}
|
|
|
|
cyPMUnitNumber OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The number of the PM unit in the daisy-chained mode."
|
|
::= { cyPMUnitEntry 1 }
|
|
|
|
cyPMUnitVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The software version of this PM unit."
|
|
::= { cyPMUnitEntry 2 }
|
|
|
|
cyPMUnitOutlets OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Number of outlets of this PM unit."
|
|
::= { cyPMUnitEntry 3 }
|
|
|
|
cyPMUnitFirstOutlet OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Number of the first outlet of this PM unit."
|
|
::= { cyPMUnitEntry 4 }
|
|
|
|
cyPMUnitCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current of this PM unit in AMP.
|
|
The value of this object is the actual current in
|
|
AMP * 10. You need to translate the readed value
|
|
(Ex. : value is 5, the current is 0.5 AMP.)"
|
|
::= { cyPMUnitEntry 5 }
|
|
|
|
cyPMUnitMaxCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Maximum current of this PM unit in AMP.
|
|
The value of this object is the maximum current in
|
|
AMP * 10. You need to translate the readed value
|
|
(Ex. : value is 5, the maximum current is 0.5 AMP.)"
|
|
::= { cyPMUnitEntry 6 }
|
|
|
|
cyPMUnitTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Temperature of this PM unit in Celsius degrees.
|
|
The value of this object is the actual temperature in
|
|
degrees C * 10. You need to translate the readed value
|
|
(Ex. : value is 240, the temperature is 24 Celsius.)
|
|
If the temperature measurement is not installed this
|
|
value will be 0.
|
|
Valid values are 5 to 999 ( 0.5 to 99.9 Celsius)."
|
|
::= { cyPMUnitEntry 7 }
|
|
|
|
cyPMUnitMaxTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Maximum temperature value of this PM unit in Celsius
|
|
degrees. The value of this object is the maximum
|
|
temperature in degrees C * 10. You need to translate
|
|
the readed value(Ex. : value is 240, the maximum
|
|
temperature is 24 Celsius).
|
|
If the temperature measurement is not installed this
|
|
value will be 0.
|
|
Valid values are 5 to 999 ( 0.5 to 99.9 Celsius)."
|
|
::= { cyPMUnitEntry 8 }
|
|
|
|
cyOutletTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CyOutletEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Allow operations on outlet"
|
|
::= { cyPM 4 }
|
|
|
|
cyOutletEntry OBJECT-TYPE
|
|
SYNTAX CyOutletEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Allow operations on outlet"
|
|
INDEX { cyPMSerialPortNumber, cyOutletNumber }
|
|
::= { cyOutletTable 1 }
|
|
|
|
CyOutletEntry ::= SEQUENCE {
|
|
cyOutletNumber InterfaceIndexOrZero,
|
|
cyOutletName DisplayString,
|
|
cyOutletServer DisplayString,
|
|
cyOutletPower INTEGER,
|
|
cyOutletLock INTEGER,
|
|
cyOutletPUInterval Integer32
|
|
}
|
|
|
|
cyOutletNumber OBJECT-TYPE
|
|
SYNTAX InterfaceIndexOrZero
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The outlet number on the PM. Zero is ALL outlets."
|
|
::= { cyOutletEntry 1 }
|
|
|
|
cyOutletName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1 .. 8))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The name given to a particular outlet Maximum size is 8 characters."
|
|
::= { cyOutletEntry 2 }
|
|
|
|
cyOutletServer OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Alias of the Server connected to this outlet ."
|
|
::= { cyOutletEntry 3 }
|
|
|
|
cyOutletPower OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off (0),
|
|
on (1),
|
|
cycle (2),
|
|
unknow (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Getting this object will return the power state of
|
|
the outlet. Valid return states are UNKNOW, OFF and
|
|
ON. Setting this object will change the power state
|
|
of the outlet."
|
|
::= { cyOutletEntry 4 }
|
|
|
|
cyOutletLock OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unlock (0),
|
|
lock (1),
|
|
unknow (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Getting this object will return the lock state of
|
|
the outlet. Setting this object will change the
|
|
lock state of the outlet."
|
|
::= { cyOutletEntry 5 }
|
|
|
|
cyOutletPUInterval OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The power unit interval of this outlet in seconds.
|
|
The value of this object is the actual interval in
|
|
seconds * 10. You need to translate the readed value
|
|
(Ex. : value is 5, the interval is 0.5 seconds.)"
|
|
::= { cyOutletEntry 6 }
|
|
|
|
END
|
|
|