mirror of
https://github.com/librenms/librenms.git
synced 2024-10-07 16:52:45 +00:00
* Extract DiscoveryItem and move some things to better places. Extract model class Fix up model construction. I have problem with construction... Makeshift model working. Switch constructor to factory. discover() and create() Support legacy discovery. Remove uneeded custom pollers Remove netonix custom detection as we try ucd on all os now. Add a few yaml procs. Fix a couple things. More processor discovery conversions Move Calix e7 to standard hrProcessorLoad, but it doesn't fully implement the HR-MIB, move things around to make it work. Add a few yaml procs. Fix a couple things. Correct some stupid mib stuff. Move more, drop php 5.3 Add netscaler which uses string indexes. Port fiberhome to yaml and use skip_values More conversions. BroadcomProcessorUsage Trait Serveriron and Ironware share some mibs. Create a common abstract os for them. Add yaml support for mib specification in each data entry Make legacy discover_processor() set 0 for hrDeviceIndex Untangle Dell switch OS processors Use use shared OS for groups if they don't have a specific group. fix silly mib mistake Make index optional Move HR and UCD to Traits and out of Processor. * forgot to update the fortiswitch index * Make sgos and avaya-ers match the old index. * fix comware test data * fix merge errors * fix dsm and remove pointless empty modules * file not found exception is in the wrong place. * Updated processor development docs
1362 lines
31 KiB
Plaintext
1362 lines
31 KiB
Plaintext
FOUNDRY-SN-IPX-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE,Counter32,Integer32
|
|
FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION
|
|
FROM SNMPv2-TC
|
|
router
|
|
FROM FOUNDRY-SN-ROOT-MIB
|
|
PhysAddress
|
|
FROM FOUNDRY-SN-SWITCH-GROUP-MIB;
|
|
|
|
snIpx MODULE-IDENTITY
|
|
LAST-UPDATED "201006020000Z" -- 04 June 2010
|
|
ORGANIZATION "Brocade Communications Systems, Inc."
|
|
CONTACT-INFO
|
|
"Technical Support Center
|
|
130 Holger Way,
|
|
San Jose, CA 95134
|
|
Email: ipsupport@brocade.com
|
|
Phone: 1-800-752-8061
|
|
URL: www.brocade.com"
|
|
DESCRIPTION
|
|
"Copyright 1996-2010 Brocade Communications Systems, Inc.
|
|
All rights reserved.
|
|
This Brocade Communications Systems SNMP Management Information Base Specification
|
|
embodies Brocade Communications Systems' confidential and proprietary
|
|
intellectual property. Brocade Communications Systems retains all
|
|
title and ownership in the Specification, including any revisions.
|
|
|
|
This Specification is supplied AS IS, and Brocade Communications Systems makes
|
|
no warranty, either express or implied, as to the use,
|
|
operation, condition, or performance of the specification, and any unintended
|
|
consequence it may on the user environment."
|
|
|
|
REVISION "201006020000Z" -- 04 June 2010
|
|
DESCRIPTION
|
|
"Changed the ORGANIZATION, CONTACT-INFO and DESCRIPTION fields."
|
|
|
|
REVISION "200909300000Z" -- September 30, 2009
|
|
DESCRIPTION
|
|
"convert from SMIv1 to SMIv2"
|
|
::= { router 1 }
|
|
-- textual conventions
|
|
|
|
RtrStatus ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
RtrStatus Values
|
|
"
|
|
SYNTAX INTEGER { disabled(0), enabled (1) }
|
|
|
|
|
|
|
|
ClearStatus ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Clear Status Values
|
|
"
|
|
SYNTAX INTEGER { normal(0), clear(1) }
|
|
|
|
|
|
PortIndex ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The bits 0-7 = port number.
|
|
The bits 8-15 = slot number (slot for chassis only).
|
|
ve port format bits 16-24 = 0x01, bits 0-15 = ve number
|
|
loopback port format bits 16-24 = 0x02, bits 0-15= lb number
|
|
"
|
|
SYNTAX Integer32(1..3900)
|
|
|
|
|
|
Action ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Represents a action value such as deny or permit.
|
|
"
|
|
SYNTAX INTEGER { deny(0), permit(1) }
|
|
|
|
NetNumber::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
"
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
|
|
-- SECTION 2: MIB
|
|
|
|
-- Router IPX MIB
|
|
|
|
snIpxGen OBJECT IDENTIFIER ::= { snIpx 1 }
|
|
snIpxCache OBJECT IDENTIFIER ::= { snIpx 2 }
|
|
snIpxRoute OBJECT IDENTIFIER ::= { snIpx 3 }
|
|
snIpxServer OBJECT IDENTIFIER ::= { snIpx 4 }
|
|
snIpxFwdFilter OBJECT IDENTIFIER ::= { snIpx 5 }
|
|
snIpxRipFilter OBJECT IDENTIFIER ::= { snIpx 6 }
|
|
snIpxSapFilter OBJECT IDENTIFIER ::= { snIpx 7 }
|
|
snIpxIfFwdAccess OBJECT IDENTIFIER ::= { snIpx 8 }
|
|
snIpxIfRipAccess OBJECT IDENTIFIER ::= { snIpx 9 }
|
|
snIpxIfSapAccess OBJECT IDENTIFIER ::= { snIpx 10 }
|
|
snIpxPortAddr OBJECT IDENTIFIER ::= { snIpx 11 }
|
|
snIpxPortCounters OBJECT IDENTIFIER ::= { snIpx 12 }
|
|
|
|
-- IPX General MIBs
|
|
|
|
snIpxRoutingMode OBJECT-TYPE
|
|
SYNTAX RtrStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enabled/Disabled System IPX Routing Mode status."
|
|
::= { snIpxGen 1 }
|
|
|
|
snIpxNetBiosFilterMode OBJECT-TYPE
|
|
SYNTAX RtrStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enabled/Disabled NetBios Filter Mode status."
|
|
::= { snIpxGen 2 }
|
|
|
|
|
|
snIpxClearCache OBJECT-TYPE
|
|
SYNTAX ClearStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"clear(1) will clear cache table."
|
|
::= { snIpxGen 3 }
|
|
|
|
snIpxClearRoute OBJECT-TYPE
|
|
SYNTAX ClearStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"clear(1) will clear ipx route table."
|
|
::= { snIpxGen 4 }
|
|
|
|
snIpxClearTrafficCnts OBJECT-TYPE
|
|
SYNTAX ClearStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"clear(1) will clear ipx all traffic counters.
|
|
- snIpxRcvPktsCnt, snIpxFwdPktsCnt,
|
|
snIpxRcvDropPktsCnt, snIpxTxDropPktsCnt,
|
|
snIpxRcvFiltPktsCnt, snIpxTxFiltPktsCnt."
|
|
::= { snIpxGen 5 }
|
|
|
|
|
|
snIpxRcvPktsCnt OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPX incoming packets counter."
|
|
::= { snIpxGen 6 }
|
|
|
|
|
|
snIpxTxPktsCnt OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPX Outgoing packets counter."
|
|
::= { snIpxGen 7 }
|
|
|
|
|
|
snIpxFwdPktsCnt OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPX forwarding packets counter."
|
|
::= { snIpxGen 8 }
|
|
|
|
snIpxRcvDropPktsCnt OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPX receiving drop packets counter."
|
|
::= { snIpxGen 9 }
|
|
|
|
snIpxRcvFiltPktsCnt OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPX receiving filter packets counter."
|
|
::= { snIpxGen 10 }
|
|
|
|
snIpxRipGblFiltList OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(0..32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An IPX RIP Global Filter List. Null value indicates no filter list."
|
|
::= { snIpxGen 11 }
|
|
|
|
snIpxRipFiltOnAllPort OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
valid(1),
|
|
deleteAllInBound(2),
|
|
deleteAllOutBound(3),
|
|
addAllInBound(4),
|
|
addAllOutBound(5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Apply the IPX RIP Global filter list snIpxRipGblFiltList to
|
|
all interfaces. This object is used to add all RIP filter
|
|
lists and delete all RIP filter lists to/from all ports.
|
|
Prior to sending this command, snIpxRipGblFiltList must be ready.
|
|
The values that can be written are:
|
|
deleteAllInBound(2)...delete all in-bound filter lists from all ports.
|
|
deleteAllOutBound(3)..delete all out-bound filter lists from all ports.
|
|
addAllInBound(4)......add all in-bound filter lists to all ports.
|
|
addAllOutBound(5).....add all out-bound filter lists to all ports.
|
|
|
|
If set operation is failed, then a SET with
|
|
value of (2)or(3) returns error 'GenError'.
|
|
Deleted(2)&(3) go away immediately.
|
|
The following values can be returned on reads:
|
|
noSuch(0)...no such operation yet.
|
|
valid(1)....set operation is done and is valid"
|
|
|
|
::= { snIpxGen 12 }
|
|
|
|
snIpxSapGblFiltList OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(0..32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An IPX SAP Global Filter List. Null value indicates no filter list"
|
|
::= { snIpxGen 13 }
|
|
|
|
|
|
snIpxSapFiltOnAllPort OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
valid(1),
|
|
deleteAllInBound(2),
|
|
deleteAllOutBound(3),
|
|
addAllInBound(4),
|
|
addAllOutBound(5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Apply the IPX SAP Global filter list snIpxSapGblFiltList to
|
|
all interfaces. This object is used to add all RIP filter
|
|
lists and delete all SAP filter lists to/from all ports.
|
|
Prior to sending this command, snIpxSapGblFiltList must be ready.
|
|
The values that can be written are:
|
|
deleteAllInBound(2)...delete all in-bound filter lists from all ports.
|
|
deleteAllOutBound(3)..delete all out-bound filter lists from all ports.
|
|
addAllInBound(4)......add all in-bound filter lists to all ports.
|
|
addAllOutBound(5).....add all out-bound filter lists to all ports.
|
|
|
|
If set operation is failed, then a SET with
|
|
value of (2)or(3) returns error 'GenError'.
|
|
Deleted(2)&(3) go away immediately.
|
|
The following values can be returned on reads:
|
|
noSuch(0)...no such operation yet.
|
|
valid(1)....set operation is done and is valid"
|
|
::= { snIpxGen 14 }
|
|
|
|
snIpxTxDropPktsCnt OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPX transmitting drop packets counter."
|
|
::= { snIpxGen 15 }
|
|
|
|
snIpxTxFiltPktsCnt OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPX transmitting filter packets counter."
|
|
::= { snIpxGen 16 }
|
|
|
|
|
|
-- IPX Cache table
|
|
|
|
snIpxCacheTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SnIpxCacheEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPX Cache table."
|
|
::= { snIpxCache 1 }
|
|
|
|
snIpxCacheEntry OBJECT-TYPE
|
|
SYNTAX SnIpxCacheEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the IPX Cache table."
|
|
INDEX { snIpxCacheIndex }
|
|
::= { snIpxCacheTable 1 }
|
|
|
|
SnIpxCacheEntry ::= SEQUENCE {
|
|
snIpxCacheIndex
|
|
Integer32,
|
|
snIpxCacheNetNum
|
|
NetNumber,
|
|
snIpxCacheNode
|
|
PhysAddress,
|
|
snIpxCacheOutFilter
|
|
RtrStatus,
|
|
snIpxCacheEncap
|
|
INTEGER,
|
|
snIpxCachePort
|
|
PortIndex
|
|
}
|
|
|
|
snIpxCacheIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table index for a IPX Cache entry."
|
|
::= { snIpxCacheEntry 1 }
|
|
|
|
|
|
snIpxCacheNetNum OBJECT-TYPE
|
|
SYNTAX NetNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cache Network number."
|
|
::= { snIpxCacheEntry 2 }
|
|
|
|
snIpxCacheNode OBJECT-TYPE
|
|
SYNTAX PhysAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cache Node Number."
|
|
::= { snIpxCacheEntry 3 }
|
|
|
|
snIpxCacheOutFilter OBJECT-TYPE
|
|
SYNTAX RtrStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cache Outbound Filter is ether disabled(0) or enabled(1)."
|
|
::= { snIpxCacheEntry 4 }
|
|
|
|
snIpxCacheEncap OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ethernetII(1),
|
|
ethernet8022(2),
|
|
ethernet8023(3),
|
|
ethernetSnap(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IPX encapsulation frame type."
|
|
::= { snIpxCacheEntry 5 }
|
|
|
|
|
|
snIpxCachePort OBJECT-TYPE
|
|
SYNTAX PortIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPX Router Port number."
|
|
::= { snIpxCacheEntry 6 }
|
|
|
|
|
|
|
|
|
|
-- IPX route table
|
|
|
|
snIpxRouteTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SnIpxRouteEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPX route table."
|
|
::= { snIpxRoute 1 }
|
|
|
|
snIpxRouteEntry OBJECT-TYPE
|
|
SYNTAX SnIpxRouteEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the IPX route table."
|
|
INDEX { snIpxRouteIndex }
|
|
::= { snIpxRouteTable 1 }
|
|
|
|
SnIpxRouteEntry ::= SEQUENCE {
|
|
snIpxRouteIndex
|
|
Integer32,
|
|
snIpxDestNetNum
|
|
NetNumber,
|
|
snIpxFwdRouterNode
|
|
PhysAddress,
|
|
snIpxDestHopCnts
|
|
Integer32,
|
|
snIpxRouteMetric
|
|
Integer32,
|
|
snIpxDestPort
|
|
Integer32
|
|
}
|
|
|
|
snIpxRouteIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table index for a IPX route entry."
|
|
::= { snIpxRouteEntry 1 }
|
|
|
|
snIpxDestNetNum OBJECT-TYPE
|
|
SYNTAX NetNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Destination Network number."
|
|
::= { snIpxRouteEntry 2 }
|
|
|
|
snIpxFwdRouterNode OBJECT-TYPE
|
|
SYNTAX PhysAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Forward Router Node Number."
|
|
::= { snIpxRouteEntry 3 }
|
|
|
|
snIpxDestHopCnts OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of hops to reach the
|
|
destination."
|
|
::= { snIpxRouteEntry 4 }
|
|
|
|
snIpxRouteMetric OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The metrics to next hop router."
|
|
::= { snIpxRouteEntry 5 }
|
|
|
|
snIpxDestPort OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The destination port."
|
|
::= { snIpxRouteEntry 6 }
|
|
|
|
|
|
-- IPX Server table
|
|
|
|
snIpxServerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SnIpxServerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPX Server table."
|
|
::= { snIpxServer 1 }
|
|
|
|
snIpxServerEntry OBJECT-TYPE
|
|
SYNTAX SnIpxServerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the IPX Server table."
|
|
INDEX { snIpxServerIndex }
|
|
::= { snIpxServerTable 1 }
|
|
|
|
SnIpxServerEntry ::= SEQUENCE {
|
|
snIpxServerIndex
|
|
Integer32,
|
|
snIpxServerType
|
|
Integer32,
|
|
snIpxServerNetNum
|
|
NetNumber,
|
|
snIpxServerNode
|
|
PhysAddress,
|
|
snIpxServerSocket
|
|
Integer32,
|
|
snIpxServerHopCnts
|
|
Integer32,
|
|
snIpxServerName
|
|
OCTET STRING
|
|
}
|
|
|
|
snIpxServerIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table index for a IPX Server entry."
|
|
::= { snIpxServerEntry 1 }
|
|
|
|
|
|
snIpxServerType OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPX Server Type."
|
|
::= { snIpxServerEntry 2 }
|
|
|
|
snIpxServerNetNum OBJECT-TYPE
|
|
SYNTAX NetNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Server Network number."
|
|
::= { snIpxServerEntry 3 }
|
|
|
|
snIpxServerNode OBJECT-TYPE
|
|
SYNTAX PhysAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Server Node Number."
|
|
::= { snIpxServerEntry 4 }
|
|
|
|
snIpxServerSocket OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Server Socket Number."
|
|
::= { snIpxServerEntry 5 }
|
|
|
|
snIpxServerHopCnts OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of intervening networks to reach the
|
|
server."
|
|
::= { snIpxServerEntry 6 }
|
|
|
|
|
|
snIpxServerName OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(0..47))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPX Server Name."
|
|
::= { snIpxServerEntry 7 }
|
|
|
|
|
|
|
|
-- IPX Forward Filter table
|
|
|
|
snIpxFwdFilterTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SnIpxFwdFilterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPX Forward Filter table."
|
|
::= { snIpxFwdFilter 1 }
|
|
|
|
snIpxFwdFilterEntry OBJECT-TYPE
|
|
SYNTAX SnIpxFwdFilterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the IPX Forward Filter table."
|
|
INDEX { snIpxFwdFilterIdx }
|
|
::= { snIpxFwdFilterTable 1 }
|
|
|
|
SnIpxFwdFilterEntry ::= SEQUENCE {
|
|
snIpxFwdFilterIdx
|
|
Integer32,
|
|
snIpxFwdFilterAction
|
|
Action,
|
|
snIpxFwdFilterSocket
|
|
Integer32,
|
|
snIpxFwdFilterSrcNet
|
|
NetNumber,
|
|
snIpxFwdFilterSrcNode
|
|
PhysAddress,
|
|
snIpxFwdFilterDestNet
|
|
NetNumber,
|
|
snIpxFwdFilterDestNode
|
|
PhysAddress,
|
|
snIpxFwdFilterRowStatus
|
|
INTEGER
|
|
}
|
|
|
|
snIpxFwdFilterIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The filter ID for a filter entry."
|
|
::= { snIpxFwdFilterEntry 1 }
|
|
|
|
snIpxFwdFilterAction OBJECT-TYPE
|
|
SYNTAX Action
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Action to take if the ipx packet match
|
|
with this filter."
|
|
::= { snIpxFwdFilterEntry 2 }
|
|
|
|
snIpxFwdFilterSocket OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPX Forward Filter Socket Number."
|
|
::= { snIpxFwdFilterEntry 3 }
|
|
|
|
snIpxFwdFilterSrcNet OBJECT-TYPE
|
|
SYNTAX NetNumber
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Source Network Number."
|
|
::= { snIpxFwdFilterEntry 4 }
|
|
|
|
snIpxFwdFilterSrcNode OBJECT-TYPE
|
|
SYNTAX PhysAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Source Node Number."
|
|
::= { snIpxFwdFilterEntry 5 }
|
|
|
|
snIpxFwdFilterDestNet OBJECT-TYPE
|
|
SYNTAX NetNumber
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Destination Network Number."
|
|
::= { snIpxFwdFilterEntry 6 }
|
|
|
|
snIpxFwdFilterDestNode OBJECT-TYPE
|
|
SYNTAX PhysAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Destination Node Number."
|
|
::= { snIpxFwdFilterEntry 7 }
|
|
|
|
snIpxFwdFilterRowStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
invalid(1),
|
|
valid(2),
|
|
delete(3),
|
|
create(4),
|
|
modify(5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to create and
|
|
delete row in the table and control
|
|
if they are used. The values
|
|
that can be written are:
|
|
delete(3)...deletes the row
|
|
create(4)...creates a new row
|
|
modify(5)...modifies an exsisting row
|
|
|
|
If the row exists, then a SET with
|
|
value of create(4) returns error
|
|
'badValue'. Deleted rows go away
|
|
immediately. The following values
|
|
can be returned on reads:
|
|
noSuch(0)...no such row
|
|
invalid(1)...Setting it to 'invalid' has the effect of
|
|
rendering it inoperative..
|
|
valid(2)....the row exists and is valid"
|
|
::= { snIpxFwdFilterEntry 8 }
|
|
|
|
|
|
|
|
-- IPX RIP Filter table
|
|
|
|
snIpxRipFilterTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SnIpxRipFilterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPX RIP Filter table."
|
|
::= { snIpxRipFilter 1 }
|
|
|
|
snIpxRipFilterEntry OBJECT-TYPE
|
|
SYNTAX SnIpxRipFilterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the IPX RIP Filter table."
|
|
INDEX { snIpxRipFilterId }
|
|
::= { snIpxRipFilterTable 1 }
|
|
|
|
SnIpxRipFilterEntry ::= SEQUENCE {
|
|
snIpxRipFilterId
|
|
Integer32,
|
|
snIpxRipFilterAction
|
|
Action,
|
|
snIpxRipFilterNet
|
|
NetNumber,
|
|
snIpxRipFilterMask
|
|
NetNumber,
|
|
snIpxRipFilterRowStatus
|
|
INTEGER
|
|
}
|
|
|
|
snIpxRipFilterId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The filter ID for a filter entry."
|
|
::= { snIpxRipFilterEntry 1 }
|
|
|
|
snIpxRipFilterAction OBJECT-TYPE
|
|
SYNTAX Action
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Action to take if the ipx packet match
|
|
with this filter."
|
|
::= { snIpxRipFilterEntry 2 }
|
|
|
|
snIpxRipFilterNet OBJECT-TYPE
|
|
SYNTAX NetNumber
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPX RIP Filter Network number."
|
|
::= { snIpxRipFilterEntry 3 }
|
|
|
|
snIpxRipFilterMask OBJECT-TYPE
|
|
SYNTAX NetNumber
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPX RIP Filter Network/Subnet Mask."
|
|
::= { snIpxRipFilterEntry 4 }
|
|
|
|
|
|
snIpxRipFilterRowStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
invalid(1),
|
|
valid(2),
|
|
delete(3),
|
|
create(4),
|
|
modify(5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to create and
|
|
delete row in the table and control
|
|
if they are used. The values
|
|
that can be written are:
|
|
delete(3)...deletes the row
|
|
create(4)...creates a new row
|
|
modify(5)...modifies an exsisting row
|
|
|
|
If the row exists, then a SET with
|
|
value of create(4) returns error
|
|
'badValue'. Deleted rows go away
|
|
immediately. The following values
|
|
can be returned on reads:
|
|
noSuch(0)...no such row
|
|
invalid(1)...Setting it to 'invalid' has the effect of
|
|
rendering it inoperative..
|
|
valid(2)....the row exists and is valid"
|
|
::= { snIpxRipFilterEntry 5 }
|
|
|
|
|
|
|
|
-- IPX SAP Filter table
|
|
|
|
snIpxSapFilterTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SnIpxSapFilterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPX SAP Filter table."
|
|
::= { snIpxSapFilter 1 }
|
|
|
|
snIpxSapFilterEntry OBJECT-TYPE
|
|
SYNTAX SnIpxSapFilterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the IPX SAP Filter table."
|
|
INDEX { snIpxSapFilterId }
|
|
::= { snIpxSapFilterTable 1 }
|
|
|
|
SnIpxSapFilterEntry ::= SEQUENCE {
|
|
snIpxSapFilterId
|
|
Integer32,
|
|
snIpxSapFilterAction
|
|
Action,
|
|
snIpxSapFilterType
|
|
Integer32,
|
|
snIpxSapFilterName
|
|
OCTET STRING,
|
|
snIpxSapFilterRowStatus
|
|
INTEGER
|
|
}
|
|
|
|
snIpxSapFilterId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The filter ID for a filter entry."
|
|
::= { snIpxSapFilterEntry 1 }
|
|
|
|
snIpxSapFilterAction OBJECT-TYPE
|
|
SYNTAX Action
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Action to take if the ipx packet match
|
|
with this filter."
|
|
::= { snIpxSapFilterEntry 2 }
|
|
|
|
snIpxSapFilterType OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPX SAP Filter type to be matched."
|
|
::= { snIpxSapFilterEntry 3 }
|
|
|
|
snIpxSapFilterName OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(0..47))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPX SAP Filter Name."
|
|
::= { snIpxSapFilterEntry 4 }
|
|
|
|
|
|
snIpxSapFilterRowStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
invalid(1),
|
|
valid(2),
|
|
delete(3),
|
|
create(4),
|
|
modify(5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to create and
|
|
delete row in the table and control
|
|
if they are used. The values
|
|
that can be written are:
|
|
delete(3)...deletes the row
|
|
create(4)...creates a new row
|
|
modify(5)...modifies an exsisting row
|
|
|
|
If the row exists, then a SET with
|
|
value of create(4) returns error
|
|
'badValue'. Deleted rows go away
|
|
immediately. The following values
|
|
can be returned on reads:
|
|
noSuch(0)...no such row
|
|
invalid(1)...Setting it to 'invalid' has the effect of
|
|
rendering it inoperative..
|
|
valid(2)....the row exists and is valid"
|
|
::= { snIpxSapFilterEntry 5 }
|
|
|
|
|
|
-- IPX IF Forward Access table
|
|
|
|
snIpxIfFwdAccessTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SnIpxIfFwdAccessEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPX IF Forward Access table."
|
|
::= { snIpxIfFwdAccess 1 }
|
|
|
|
snIpxIfFwdAccessEntry OBJECT-TYPE
|
|
SYNTAX SnIpxIfFwdAccessEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the IPX Forward Access table."
|
|
INDEX { snIpxIfFwdAccessPort, snIpxIfFwdAccessDir }
|
|
::= { snIpxIfFwdAccessTable 1 }
|
|
|
|
SnIpxIfFwdAccessEntry ::= SEQUENCE {
|
|
snIpxIfFwdAccessPort
|
|
Integer32,
|
|
snIpxIfFwdAccessDir
|
|
INTEGER,
|
|
snIpxIfFwdAccessFilterList
|
|
OCTET STRING,
|
|
snIpxIfFwdAccessRowStatus
|
|
INTEGER
|
|
}
|
|
|
|
snIpxIfFwdAccessPort OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IPX interface to which the Forward Filter applies."
|
|
::= { snIpxIfFwdAccessEntry 1 }
|
|
|
|
snIpxIfFwdAccessDir OBJECT-TYPE
|
|
SYNTAX INTEGER { in(1), out(2) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The access direction of incoming packet filter
|
|
or outgoing packet filter."
|
|
::= { snIpxIfFwdAccessEntry 2 }
|
|
|
|
snIpxIfFwdAccessFilterList OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(1..32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An IPX IF Forward Filter List."
|
|
::= { snIpxIfFwdAccessEntry 3 }
|
|
|
|
|
|
snIpxIfFwdAccessRowStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
invalid(1),
|
|
valid(2),
|
|
delete(3),
|
|
create(4),
|
|
modify(5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to create and
|
|
delete row in the table and control
|
|
if they are used. The values
|
|
that can be written are:
|
|
delete(3)...deletes the row
|
|
create(4)...creates a new row
|
|
modify(5)...modifies an exsisting row
|
|
|
|
If the row exists, then a SET with
|
|
value of create(4) returns error
|
|
'badValue'. Deleted rows go away
|
|
immediately. The following values
|
|
can be returned on reads:
|
|
noSuch(0)...no such row
|
|
invalid(1)...Setting it to 'invalid' has the effect of
|
|
rendering it inoperative..
|
|
valid(2)....the row exists and is valid"
|
|
::= { snIpxIfFwdAccessEntry 4 }
|
|
|
|
|
|
|
|
-- IPX IF RIP Access table
|
|
|
|
snIpxIfRipAccessTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SnIpxIfRipAccessEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPX IF RIP Access table."
|
|
::= { snIpxIfRipAccess 1 }
|
|
|
|
snIpxIfRipAccessEntry OBJECT-TYPE
|
|
SYNTAX SnIpxIfRipAccessEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the IPX Forward Access table."
|
|
INDEX { snIpxIfRipAccessPort, snIpxIfRipAccessDir }
|
|
::= { snIpxIfRipAccessTable 1 }
|
|
|
|
SnIpxIfRipAccessEntry ::= SEQUENCE {
|
|
snIpxIfRipAccessPort
|
|
Integer32,
|
|
snIpxIfRipAccessDir
|
|
INTEGER,
|
|
snIpxIfRipAccessFilterList
|
|
OCTET STRING,
|
|
snIpxIfRipAccessRowStatus
|
|
INTEGER
|
|
}
|
|
|
|
snIpxIfRipAccessPort OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IPX interface to which the RIP Filter applies."
|
|
::= { snIpxIfRipAccessEntry 1 }
|
|
|
|
snIpxIfRipAccessDir OBJECT-TYPE
|
|
SYNTAX INTEGER { in(1), out(2) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The access direction of incoming packet filter
|
|
or outgoing packet filter."
|
|
::= { snIpxIfRipAccessEntry 2 }
|
|
|
|
snIpxIfRipAccessFilterList OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(1..32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An IPX IF RIP Access Filter List."
|
|
::= { snIpxIfRipAccessEntry 3 }
|
|
|
|
|
|
snIpxIfRipAccessRowStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
invalid(1),
|
|
valid(2),
|
|
delete(3),
|
|
create(4),
|
|
modify(5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to create and
|
|
delete row in the table and control
|
|
if they are used. The values
|
|
that can be written are:
|
|
delete(3)...deletes the row
|
|
create(4)...creates a new row
|
|
modify(5)...modifies an exsisting row
|
|
|
|
If the row exists, then a SET with
|
|
value of create(4) returns error
|
|
'badValue'. Deleted rows go away
|
|
immediately. The following values
|
|
can be returned on reads:
|
|
noSuch(0)...no such row
|
|
invalid(1)...Setting it to 'invalid' has the effect of
|
|
rendering it inoperative..
|
|
valid(2)....the row exists and is valid"
|
|
::= { snIpxIfRipAccessEntry 4 }
|
|
|
|
|
|
-- IPX IF SAP Access table
|
|
|
|
snIpxIfSapAccessTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SnIpxIfSapAccessEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPX IF RIP Access table."
|
|
::= { snIpxIfSapAccess 1 }
|
|
|
|
snIpxIfSapAccessEntry OBJECT-TYPE
|
|
SYNTAX SnIpxIfSapAccessEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the IPX Forward Access table."
|
|
INDEX { snIpxIfSapAccessPort, snIpxIfSapAccessDir }
|
|
::= { snIpxIfSapAccessTable 1 }
|
|
|
|
SnIpxIfSapAccessEntry ::= SEQUENCE {
|
|
snIpxIfSapAccessPort
|
|
Integer32,
|
|
snIpxIfSapAccessDir
|
|
INTEGER,
|
|
snIpxIfSapAccessFilterList
|
|
OCTET STRING,
|
|
snIpxIfSapAccessRowStatus
|
|
INTEGER
|
|
}
|
|
|
|
snIpxIfSapAccessPort OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IPX interface to which the SAP Filter applies."
|
|
::= { snIpxIfSapAccessEntry 1 }
|
|
|
|
snIpxIfSapAccessDir OBJECT-TYPE
|
|
SYNTAX INTEGER { in(1), out(2) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The access direction of incoming packet filter
|
|
or outgoing packet filter."
|
|
::= { snIpxIfSapAccessEntry 2 }
|
|
|
|
snIpxIfSapAccessFilterList OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(1..32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An IPX IF SAP Access Filter List."
|
|
::= { snIpxIfSapAccessEntry 3 }
|
|
|
|
|
|
snIpxIfSapAccessRowStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
invalid(1),
|
|
valid(2),
|
|
delete(3),
|
|
create(4),
|
|
modify(5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to create and
|
|
delete row in the table and control
|
|
if they are used. The values
|
|
that can be written are:
|
|
delete(3)...deletes the row
|
|
create(4)...creates a new row
|
|
modify(5)...modifies an exsisting row
|
|
|
|
If the row exists, then a SET with
|
|
value of create(4) returns error
|
|
'badValue'. Deleted rows go away
|
|
immediately. The following values
|
|
can be returned on reads:
|
|
noSuch(0)...no such row
|
|
invalid(1)...Setting it to 'invalid' has the effect of
|
|
rendering it inoperative..
|
|
valid(2)....the row exists and is valid"
|
|
::= { snIpxIfSapAccessEntry 4 }
|
|
|
|
|
|
-- ipx interface address table
|
|
|
|
snIpxPortAddrTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SnIpxPortAddrEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPX port address table."
|
|
::= { snIpxPortAddr 1 }
|
|
|
|
snIpxPortAddrEntry OBJECT-TYPE
|
|
SYNTAX SnIpxPortAddrEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the IPX Port Address table."
|
|
INDEX { snIpxPortAddrPort, snIpxPortAddrEncap }
|
|
::= { snIpxPortAddrTable 1 }
|
|
|
|
SnIpxPortAddrEntry ::= SEQUENCE {
|
|
snIpxPortAddrPort
|
|
PortIndex,
|
|
snIpxPortAddrEncap
|
|
INTEGER,
|
|
snIpxPortAddrNetNum
|
|
NetNumber,
|
|
snIpxPortAddrRowStatus
|
|
INTEGER,
|
|
snIpxPortAddrNetBiosFilterMode
|
|
RtrStatus
|
|
}
|
|
|
|
|
|
snIpxPortAddrPort OBJECT-TYPE
|
|
SYNTAX PortIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The port index for port address entry."
|
|
::= { snIpxPortAddrEntry 1 }
|
|
|
|
snIpxPortAddrEncap OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ethernet8022(1),
|
|
ethernet8023(2),
|
|
ethernetII(3),
|
|
ethernetSnap(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IPX encapsulation type.
|
|
ethernet8022(1), ethernet8023(2),
|
|
ethernetII(3), ethernetSnap(4)
|
|
Note: Each Network Number can be assigned with one unique Frame type; Otherwise,
|
|
a SNMP-SET error will be returned."
|
|
::= { snIpxPortAddrEntry 2 }
|
|
|
|
snIpxPortAddrNetNum OBJECT-TYPE
|
|
SYNTAX NetNumber
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An unique Network number for the IPX interface port."
|
|
::= { snIpxPortAddrEntry 3 }
|
|
|
|
snIpxPortAddrRowStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
invalid(1),
|
|
valid(2),
|
|
delete(3),
|
|
create(4),
|
|
modify(5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to create and
|
|
delete row in the table and control
|
|
if they are used. The values
|
|
that can be written are:
|
|
delete(3)...deletes the row
|
|
create(4)...creates a new row
|
|
modify(5)...modifies an exsisting row
|
|
|
|
If the row exists, then a SET with
|
|
value of create(4) returns error
|
|
'badValue'. Deleted rows go away
|
|
immediately. The following values
|
|
can be returned on reads:
|
|
noSuch(0)...no such row
|
|
invalid(1)...Setting it to 'invalid' has the effect of
|
|
rendering it inoperative..
|
|
valid(2)....the row exists and is valid"
|
|
::= { snIpxPortAddrEntry 4 }
|
|
|
|
snIpxPortAddrNetBiosFilterMode OBJECT-TYPE
|
|
SYNTAX RtrStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enabled/Disabled NetBios Filter Mode status per Port Address entry."
|
|
::= { snIpxPortAddrEntry 5 }
|
|
|
|
|
|
-- ipx port counters table
|
|
|
|
snIpxPortCountersTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SnIpxPortCountersEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPX port Counters table."
|
|
::= { snIpxPortCounters 1 }
|
|
|
|
snIpxPortCountersEntry OBJECT-TYPE
|
|
SYNTAX SnIpxPortCountersEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the IPX Port Counters table."
|
|
INDEX { snIpxPortCountersPort }
|
|
::= { snIpxPortCountersTable 1 }
|
|
|
|
SnIpxPortCountersEntry ::= SEQUENCE {
|
|
snIpxPortCountersPort
|
|
PortIndex,
|
|
snIpxPortCountersRcvPktsCnt
|
|
Counter32,
|
|
snIpxPortCountersTxPktsCnt
|
|
Counter32,
|
|
snIpxPortCountersFwdPktsCnt
|
|
Counter32,
|
|
snIpxPortCountersRcvDropPktsCnt
|
|
Counter32,
|
|
snIpxPortCountersTxDropPktsCnt
|
|
Counter32,
|
|
snIpxPortCountersRcvFiltPktsCnt
|
|
Counter32,
|
|
snIpxPortCountersTxFiltPktsCnt
|
|
Counter32
|
|
}
|
|
|
|
|
|
snIpxPortCountersPort OBJECT-TYPE
|
|
SYNTAX PortIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The port index for port Counters entry."
|
|
::= { snIpxPortCountersEntry 1 }
|
|
|
|
snIpxPortCountersRcvPktsCnt OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPX incoming packets counter for the interface."
|
|
::= { snIpxPortCountersEntry 2 }
|
|
|
|
|
|
snIpxPortCountersTxPktsCnt OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPX Outgoing packets counter for the interface."
|
|
::= { snIpxPortCountersEntry 3 }
|
|
|
|
|
|
snIpxPortCountersFwdPktsCnt OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPX forwarding packets counter for the interface."
|
|
::= { snIpxPortCountersEntry 4 }
|
|
|
|
snIpxPortCountersRcvDropPktsCnt OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPX receiving drop packets counter for the interface."
|
|
::= { snIpxPortCountersEntry 5 }
|
|
|
|
snIpxPortCountersTxDropPktsCnt OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPX transmitting drop packets counter for the interface."
|
|
::= { snIpxPortCountersEntry 6 }
|
|
|
|
snIpxPortCountersRcvFiltPktsCnt OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPX receiving filter packets counter for the interface."
|
|
::= { snIpxPortCountersEntry 7 }
|
|
|
|
snIpxPortCountersTxFiltPktsCnt OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPX transmitting filter packets counter for the interface."
|
|
::= { snIpxPortCountersEntry 8 }
|
|
|
|
|
|
|
|
END
|
|
|