* Extract DiscoveryItem and move some things to better places. Extract model class Fix up model construction. I have problem with construction... Makeshift model working. Switch constructor to factory. discover() and create() Support legacy discovery. Remove uneeded custom pollers Remove netonix custom detection as we try ucd on all os now. Add a few yaml procs. Fix a couple things. More processor discovery conversions Move Calix e7 to standard hrProcessorLoad, but it doesn't fully implement the HR-MIB, move things around to make it work. Add a few yaml procs. Fix a couple things. Correct some stupid mib stuff. Move more, drop php 5.3 Add netscaler which uses string indexes. Port fiberhome to yaml and use skip_values More conversions. BroadcomProcessorUsage Trait Serveriron and Ironware share some mibs. Create a common abstract os for them. Add yaml support for mib specification in each data entry Make legacy discover_processor() set 0 for hrDeviceIndex Untangle Dell switch OS processors Use use shared OS for groups if they don't have a specific group. fix silly mib mistake Make index optional Move HR and UCD to Traits and out of Processor. * forgot to update the fortiswitch index * Make sgos and avaya-ers match the old index. * fix comware test data * fix merge errors * fix dsm and remove pointless empty modules * file not found exception is in the wrong place. * Updated processor development docs
3562 lines
109 KiB
Plaintext
3562 lines
109 KiB
Plaintext
--
|
|
-- Title: Fibre Channel Switch MIB.
|
|
--
|
|
-- This is specified based on SMIv2, mainly to ensure that the specification
|
|
-- can be parsed easily by off-the-shelf network management product in
|
|
-- the market.
|
|
--
|
|
-- The goal of this mib is to access the any Fibre Channel switch of
|
|
-- Brocade's family by using single SW-MIB file.
|
|
-- This mib file includes the traps for Silkworm Switch.
|
|
-- NOTE: Load BRCD.mib file before loading this mib file.
|
|
--
|
|
|
|
SW-MIB DEFINITIONS ::= BEGIN
|
|
IMPORTS
|
|
DisplayString, TEXTUAL-CONVENTION
|
|
FROM SNMPv2-TC
|
|
Counter32, Integer32, IpAddress,
|
|
OBJECT-TYPE, OBJECT-IDENTITY,
|
|
MODULE-IDENTITY, NOTIFICATION-TYPE
|
|
FROM SNMPv2-SMI
|
|
FcWwn, SwDomainIndex, SwNbIndex, SwSensorIndex,
|
|
SwPortIndex, SwTrunkMaster
|
|
FROM Brocade-TC
|
|
fcSwitch, bcsiModules
|
|
FROM Brocade-REG-MIB
|
|
connUnitPortStatEntry
|
|
FROM FCMGMT-MIB;
|
|
|
|
swMibModule MODULE-IDENTITY
|
|
LAST-UPDATED "200408061830Z" -- Aug 06, 2004 6:30pm
|
|
ORGANIZATION "Brocade Communications Systems, Inc.,"
|
|
CONTACT-INFO "Customer Support Group
|
|
Brocade Communications Systems,
|
|
1745 Technology Drive,
|
|
San Jose, CA 95110 U.S.A
|
|
Tel: +1-408-392-6061
|
|
Fax: +1-408-392-6656
|
|
Email: support@Brocade.COM
|
|
WEB: www.brocade.com"
|
|
|
|
|
|
DESCRIPTION "The MIB module is for Brocade's Fibre Channel Switch.
|
|
Copyright (c) 1996-2003 Brocade Communications Systems, Inc.
|
|
All rights reserved."
|
|
REVISION "200301131430Z" -- Jan 13, 2003 2:30pm
|
|
DESCRIPTION "The initial version of this module."
|
|
REVISION "200307201430Z" -- July 20, 2003 2:30pm
|
|
DESCRIPTION "Added swIDIDMode to the swFabric group."
|
|
REVISION "200404151030Z" -- April 15, 2004 10:30am
|
|
DESCRIPTION "Added object for Trap Severity Level, swFwLastSeverityLevel.
|
|
Added the enumeration swFwResourceFlash for SwFwClassesAreas.
|
|
Deprecated the mib object swEventTrapLevel.
|
|
Updated the description of swGroupId and corrected the spell
|
|
mistakes.
|
|
Obsoleted the swFault Trap.
|
|
Added enumerations four-GB for swFCPortSpeed and unknown,
|
|
other for swFCPortType."
|
|
REVISION "200408061830Z" -- Aug 06, 2004 6:30pm
|
|
DESCRIPTION "Added swFCPortSpecifier object to swFCPortTable."
|
|
REVISION "200504292016Z" -- Apr 29, 2005 8:16pm
|
|
DESCRIPTION "Modified the #SUMMARY and #ARGUMENTS for swFabricWatchTrap"
|
|
REVISION "200601090900Z" -- Jan 09, 2006 9:00am
|
|
DESCRIPTION "1. Modified the description for swPortTrunked
|
|
2. Updated the SW Traps summary and description to
|
|
remove the obsolete varbindings"
|
|
REVISION "200605170900Z" -- May 17, 2006 9:00am
|
|
DESCRIPTION "Added swFCPortFlag object to swFCPortTable"
|
|
REVISION "200701230900Z" -- Jan 23, 2007 9:00am
|
|
DESCRIPTION "Added enumerations eight-GB and ten-GB for swFCPortSpeed"
|
|
REVISION "200706081200Z" -- Jun 8, 2007 12:00pm
|
|
DESCRIPTION "Included swFCPortFlag as an additiional variable binding for
|
|
trap SWFCPortScn"
|
|
REVISION "200706271030Z" -- Jun 27, 2007 10:30am
|
|
DESCRIPTION "Added enumerations octuple and decuple for swNbBaudRate"
|
|
REVISION "200708011220Z" -- Aug 01, 2007 12:20pm
|
|
DESCRIPTION "Added the enumerations swFwEPortUtil and swFwEPortPktl for swFwClassAreaIndex"
|
|
REVISION "200708290442Z" -- Aug 29, 2007 4:42pm
|
|
DESCRIPTION "Added swFCPortBrcdType object to swFCPortTable"
|
|
REVISION "200801290759Z" -- Jan 29, 2008 7:59pm
|
|
DESCRIPTION "Added Toptalker support and swVfId to the swFabric group."
|
|
REVISION "200807170345Z" -- July 17, 2008 3:45pm
|
|
DESCRIPTION "Added swIPv6ChangeTrap, swIPv6Address and swIPv6Status ."
|
|
REVISION "200807240232Z" -- July 24, 2008 2:32pm
|
|
DESCRIPTION "Added swModel to distiguish between 7500 and 7500E switch ."
|
|
REVISION "200807250232Z" -- July 25, 2008 2:32pm
|
|
DESCRIPTION "Added the enumerations swFwPortLr, swFwEPortLr, swFwEPortUtil, swFwEPortPktl,
|
|
swFwFCUPortLr, swFwFOPPortLr for swFwClassAreaIndex."
|
|
REVISION "200809090900Z" -- Sept 09, 2008 9:00pm
|
|
DESCRIPTION "Added swPmgrEventTrap information."
|
|
REVISION "200909280900Z" -- Jan 28, 2009 9:00pm
|
|
DESCRIPTION "Added additional fabric watch threshold in SwFwActs."
|
|
REVISION "200902210900Z" -- Feb 21, 2008 9:00pm
|
|
DESCRIPTION "Added port phy states."
|
|
REVISION "200903300900Z" -- Mar 30, 2009 9:00am
|
|
DESCRIPTION "Added swEventVfId in swEventTable."
|
|
REVISION "200906251200Z" -- Jun 25, 2009 12:00pm
|
|
DESCRIPTION "Removed the version information from Brocade's proprietary MIB file name."
|
|
REVISION "200906290100Z" -- Jun 29, 2009 01:00pm
|
|
DESCRIPTION "Modified swVfid position at the last of swFabric table"
|
|
REVISION "200906301306Z" -- June 30, 2009 1:06pm
|
|
DESCRIPTION "Added swFwCPUMemUsage enumeration under swFwClassAreaIndex."
|
|
REVISION "200906300600Z" -- Jun 30, 2009 06:00pm
|
|
DESCRIPTION "Updated the description of swCpuAction/swMemAction and access of
|
|
swcpuormemoryusage objects and changed the type of swEndDeviceInvalidWord,
|
|
swEndDeviceLinkFailure,swEndDeviceSyncLoss, swEndDeviceSigLoss,
|
|
swEndDeviceProtoErr,swEndDeviceInvalidCRC from integer32 to counter32."
|
|
REVISION "200910300500Z" -- Oct 30, 2009 05:00pm
|
|
DESCRIPTION "Added swFabricReconfigTrap and swFabricSegmentTrap."
|
|
REVISION "200911031306Z" -- Nov 03, 2009 1:06pm
|
|
DESCRIPTION "Removed enum switchReboot from swAdmStatus."
|
|
REVISION "200911051200Z" -- Nov 05, 2009 12:00pm
|
|
DESCRIPTION "Changed swFwCustUnit access to read-only"
|
|
REVISION "200911050500Z" -- Nov 05, 2009 05:00pm
|
|
DESCRIPTION "Added enums swFwEPortTrunkUtil,swFwFCUPortTrunkUtil and
|
|
swFwFOPPortTrunkUtil in SwFwClassesAreas"
|
|
REVISION "200911061130Z" -- Nov 06, 2009 11:30am
|
|
DESCRIPTION "Added swConnUnitExtensionTable and entries for 64 bit
|
|
portstats."
|
|
REVISION "0911301030Z" -- Nov 30, 2009 10:30am
|
|
DESCRIPTION "Added swMemUsageLimit1 and swMemUsageLimit3 under
|
|
swCpuOrMemoryUsage"
|
|
REVISION "0912031730Z" -- Dec 03, 2009 05:30pm
|
|
DESCRIPTION "Added swExttrap as internal trap."
|
|
REVISION "1001301730Z" -- Jan 30, 2010 05:30pm
|
|
DESCRIPTION "Changed the descriptions for swConnUnitExtensionTable as per latest FS."
|
|
|
|
::= { bcsiModules 3 }
|
|
|
|
sw OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "The OID sub-tree for Brocade's Silkworm Series of
|
|
Fibre Channel Switches."
|
|
::= { fcSwitch 1 }
|
|
|
|
sw28k OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "The OID for Brocade's Silkworm 2800 model Fibre Channel
|
|
Switch."
|
|
::= { fcSwitch 2 }
|
|
|
|
sw21kN24k OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "The OID for Brocade's Silkworm 2100 and 2400 series
|
|
model Fibre Channel Switch."
|
|
::= { fcSwitch 3 }
|
|
|
|
sw20x0 OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "The OID for Brocade's Silkworm 20x0 series
|
|
model Fibre Channel Switch."
|
|
::= { fcSwitch 4 }
|
|
|
|
SwSevType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "The event trap level in conjunction with the an event's
|
|
severity level."
|
|
SYNTAX INTEGER {
|
|
none (0),
|
|
critical (1),
|
|
error (2),
|
|
warning (3),
|
|
informational (4),
|
|
debug (5)
|
|
}
|
|
|
|
FcPortFlag ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "Represents the port status for a FC Flag. Currently this will indicate
|
|
if the port is virtual or physical."
|
|
SYNTAX BITS {
|
|
physical (0),
|
|
virtual (1)
|
|
}
|
|
|
|
-- various groups
|
|
swSystem OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "The OID sub-tree for swSystem group."
|
|
::= { sw 1 }
|
|
|
|
swFabric OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "The OID sub-tree for swFabric group."
|
|
::= { sw 2 }
|
|
|
|
swModule OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "The OID sub-tree for swModule group."
|
|
::= { sw 3 }
|
|
|
|
swAgtCfg OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "The OID sub-tree for swAgtCfg group."
|
|
::= { sw 4 }
|
|
|
|
-- { sw 5 } is reserved
|
|
swFCport OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "The OID sub-tree for swFCport group."
|
|
::= { sw 6 }
|
|
|
|
swNs OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "The OID sub-tree for swNs group."
|
|
::= { sw 7 }
|
|
|
|
swEvent OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "The OID sub-tree for swEvent group."
|
|
::= { sw 8 }
|
|
|
|
swFwSystem OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "The OID sub-tree for swFwSystem group."
|
|
::= { sw 10 }
|
|
|
|
swEndDevice OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "The OID sub-tree for swEndDevice group."
|
|
::= { sw 21 }
|
|
|
|
swGroup OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "The OID sub-tree for swGroup group."
|
|
::= { sw 22 }
|
|
|
|
swBlmPerfMnt OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "The OID sub-tree for swBlmPerfMnt (Bloom Performance
|
|
Monitor) group."
|
|
::= { sw 23 }
|
|
|
|
swTrunk OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "The OID sub-tree for swTrunk group."
|
|
::= { sw 24 }
|
|
|
|
swTopTalker OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "The OID sub-tree for TopTalker group."
|
|
::= { sw 25 }
|
|
|
|
swCpuOrMemoryUsage OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "The OID sub-tree for cpu or memory usage group."
|
|
::= { sw 26 }
|
|
|
|
swConnUnitPortStatExtentionTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwConnUnitPortStatEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This represents the Conn unit Port Stats"
|
|
::= { sw 27 }
|
|
|
|
--
|
|
-- the System Group (sw)
|
|
--
|
|
|
|
swCurrentDate OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE (0..64))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The current date information in displayable textual
|
|
format."
|
|
::= { swSystem 1 }
|
|
|
|
swBootDate OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE (0..64))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date and time when the system last booted, in
|
|
displayable textual format."
|
|
::= { swSystem 2 }
|
|
|
|
swFWLastUpdated OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE (0..64))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The information indicates the date when the firmware
|
|
was last updated, in displayable textual format."
|
|
::= { swSystem 3 }
|
|
|
|
swFlashLastUpdated OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE (0..64))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The information indicates the date when the FLASH
|
|
was last updated, in displayable textual format."
|
|
::= { swSystem 4 }
|
|
|
|
swBootPromLastUpdated OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE (0..64))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The information indicates the date when the boot PROM
|
|
was last updated, in displayable textual format."
|
|
::= { swSystem 5 }
|
|
|
|
swFirmwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE (0..24))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The current version of the firwmare."
|
|
::= { swSystem 6 }
|
|
|
|
swOperStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online (1),
|
|
offline (2),
|
|
testing (3),
|
|
faulty (4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The current operational status of the switch.
|
|
The states are as follow:
|
|
o online(1) means the switch is accessible by an external
|
|
Fibre Channel port;
|
|
o offline(2) means the switch is not accessible;
|
|
o testing(3) means the switch is in a built-in test mode
|
|
and is not accessible by an external Fibre Channel port;
|
|
o faulty(4) means the switch is not operational."
|
|
::= { swSystem 7 }
|
|
|
|
swAdmStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online (1),
|
|
offline (2),
|
|
testing (3),
|
|
faulty (4),
|
|
reboot (5),
|
|
fastboot (6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The desired administrative status of the switch.
|
|
A management station may place the switch in a desired
|
|
state by setting this object accordingly. The states
|
|
are as follow:
|
|
o online(1) means set the switch to be accessible by an
|
|
external Fibre Channel port;
|
|
o offline(2) means set the switch to be inaccessible;
|
|
o testing(3) means set the switch to run the built-in test;
|
|
o faulty(4) means set the switch to a 'soft' faulty
|
|
condition;
|
|
o reboot(5) means set the switch to reboot in 1 second.
|
|
o fastboot(6) means set the switch to fastboot in 1 second.
|
|
Fastboot would cause the switch to boot but skip over the
|
|
POST.
|
|
|
|
When the switch is in faulty state, only two states
|
|
can be set: faulty and reboot/fastboot."
|
|
|
|
::= { swSystem 8 }
|
|
|
|
swTelnetShellAdmStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (0),
|
|
terminated (1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The desired administrative status of the Telnet
|
|
shell. By setting it to terminated(1), the current
|
|
Telnet shell task is deleted. When this variable instance
|
|
is read, it reports the value last set through SNMP."
|
|
::= { swSystem 9 }
|
|
|
|
swSsn OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE (0..128))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The soft serial number of the switch."
|
|
::= { swSystem 10 }
|
|
|
|
-- FLASH administration
|
|
-- the next 5 objects are related to firmware or config file management.
|
|
--
|
|
-- The underlying method in the transfer of the firmware or config file
|
|
-- is based on either FTP or remote shell.
|
|
-- If a password is provided, then FTP is used.
|
|
-- If NO password is provided, then remote shell is used.
|
|
--
|
|
-- 2 steps to manage firmware or switch config file in the switch FLASH,
|
|
-- (A1) set swFlashDLHost.0, swFlashDLUser.0 and swFlashDLFile.0 to
|
|
-- appropriate
|
|
-- host IP address in user dot notation (e.g. 192.168.1.7),
|
|
-- user name (e.g. "administrator"), and
|
|
-- file name of the firmware or config file (e.g. "/home/fcswh/v2.2")
|
|
-- respectively;
|
|
-- (A2) set swFlashDLPassword.0 to an appropriate value (e.g. "secret")
|
|
-- if FTP is the desired method of transfer;
|
|
-- (B) set swFlashDLAdmStatus.0 to swFwUpgrade(2), swCfUpload(3),
|
|
-- or swCfDownload(4) accordingly.
|
|
--
|
|
|
|
swFlashDLOperStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (0),
|
|
swCurrent (1),
|
|
swFwUpgraded (2),
|
|
swCfUploaded (3),
|
|
swCfDownloaded (4),
|
|
swFwCorrupted (5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The operational status of the FLASH.
|
|
The operational states are as follow:
|
|
o swCurrent(1) indicates that the FLASH contains the
|
|
current firmware image or config file;
|
|
o swFwUpgraded(2) state indicates that it contains the image
|
|
upgraded from the swFlashDLHost.0.;
|
|
o swCfUploaded(3) state indicates that the switch configuration
|
|
file has been uploaded to the host; and
|
|
o swCfDownloaded(4) state indicates that the switch
|
|
configuration file has been downloaded from the host.
|
|
o swFwCorrupted (5) state indicates that the firmware in the
|
|
FLASH of the switch is corrupted."
|
|
::= { swSystem 11 }
|
|
|
|
swFlashDLAdmStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
swCurrent (1),
|
|
swFwUpgrade (2),
|
|
swCfUpload (3),
|
|
swCfDownload (4),
|
|
swFwCorrupted (5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The desired state of the FLASH.
|
|
A management station may place the FLASH in a desired
|
|
state by setting this object accordingly:
|
|
o swCurrent(1) indicates that the FLASH contains the
|
|
current firmware image or config file;
|
|
o swFwUpgrade(2) means that the firmware in the FLASH is to be
|
|
upgraded from the host specified;
|
|
o swCfUpload(3) means that the switch config file is to be
|
|
uploaded to the host specified; or
|
|
o swCfDownload(4) means that the switch config file is to be
|
|
downloaded from the host specified.
|
|
o swFwCorrupted(5) state indicates that the firmware in the
|
|
FLASH is corrupted. This value is for informational purpose
|
|
only. However, set of swFlashDLAdmStatus to this value is
|
|
not allowed.
|
|
|
|
The host is specified in swFlashDLHost.0. In addition,
|
|
user name is specified in swFlashDLUser.0, and
|
|
the file name specified in swFlashDLFile.0.
|
|
|
|
Reference the user manual on the following commands,
|
|
o firmwareDownload,
|
|
o configUpload, and
|
|
o configDownload."
|
|
::= { swSystem 12 }
|
|
|
|
swFlashDLHost OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE (0..64))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The name or IP address (in dot notation) of the host
|
|
to download or upload a relevant file to the FLASH."
|
|
::= { swSystem 13 }
|
|
|
|
swFlashDLUser OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE (0..64))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The user name on the host to download or upload
|
|
a relevant file to or from the FLASH."
|
|
::= { swSystem 14 }
|
|
|
|
swFlashDLFile OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The name of the file to be downloaded or uploaded."
|
|
::= { swSystem 15 }
|
|
|
|
swFlashDLPassword OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE (0..100))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The password to be used in for FTP transfer of
|
|
files in the download or upload operation."
|
|
::= { swSystem 16 }
|
|
|
|
-- 17..19 are reserved
|
|
|
|
swBeaconOperStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
on (1),
|
|
off (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The current operational status of the switch beacon.
|
|
When the beacon is on, the LEDs on the front panel
|
|
of the switch run alternately from left to right
|
|
and right to left. The color is yellow.
|
|
When the beacon is off, each LED will be in their
|
|
its regular status indicating color and state."
|
|
::= { swSystem 18 }
|
|
|
|
swBeaconAdmStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
on (1),
|
|
off (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The desired status of the switch beacon.
|
|
When the beacon is set to on, the LEDs on the front
|
|
panel of the switch run alternately from left to right
|
|
and right to left. The color is yellow.
|
|
When the beacon is set to off, each LED will be in
|
|
its regular status indicating color and state."
|
|
::= { swSystem 19 }
|
|
|
|
swDiagResult OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sw-ok (1),
|
|
sw-faulty (2),
|
|
sw-embedded-port-fault (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The result of the power-on startup (POST)
|
|
diagnostics."
|
|
::= { swSystem 20 }
|
|
|
|
-- operating environment sensors (temperature, fan, power supply...)
|
|
swNumSensors OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of sensors inside the switch."
|
|
::= { swSystem 21 }
|
|
|
|
swSensorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwSensorEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The table of sensor entries."
|
|
::= { swSystem 22 }
|
|
|
|
swSensorEntry OBJECT-TYPE
|
|
SYNTAX SwSensorEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry of the sensor information."
|
|
INDEX { swSensorIndex }
|
|
::= { swSensorTable 1 }
|
|
|
|
SwSensorEntry ::= SEQUENCE {
|
|
swSensorIndex SwSensorIndex,
|
|
swSensorType INTEGER,
|
|
swSensorStatus INTEGER,
|
|
swSensorValue Integer32,
|
|
swSensorInfo DisplayString
|
|
}
|
|
|
|
swSensorIndex OBJECT-TYPE
|
|
SYNTAX SwSensorIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the sensor."
|
|
::= { swSensorEntry 1 }
|
|
|
|
swSensorType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
temperature (1),
|
|
fan (2),
|
|
power-supply (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the sensor type."
|
|
::= { swSensorEntry 2 }
|
|
|
|
swSensorStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
faulty (2),
|
|
below-min (3),
|
|
nominal (4),
|
|
above-max (5),
|
|
absent (6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The current status of the sensor."
|
|
::= { swSensorEntry 3 }
|
|
|
|
swSensorValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The current value (reading) of the sensor.
|
|
The value, -2147483648, represents an unknown quantity.
|
|
It also means that the sensor does not have the capability to
|
|
measure the actual value. In V2.0, the temperature sensor
|
|
value will be in Celsius; the fan value will be in RPM
|
|
(revolution per minute); and the power supply sensor reading
|
|
will be unknown."
|
|
::= { swSensorEntry 4 }
|
|
|
|
swSensorInfo OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Additional displayable information on the sensor.
|
|
In V2.x, it contains the sensor type and number
|
|
in textual format. For example, 'Temp 3', 'Fan 6'."
|
|
::= { swSensorEntry 5 }
|
|
|
|
-- track changes string scalar
|
|
swTrackChangesInfo OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Track changes string. For trap only"
|
|
::= { swSystem 23 }
|
|
|
|
swID OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of the logical switch (0/1)"
|
|
::= { swSystem 24 }
|
|
|
|
swEtherIPAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IP Address of the Ethernet interface of this logical
|
|
switch."
|
|
::= { swSystem 25 }
|
|
|
|
swEtherIPMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IP Mask of the Ethernet interface of this logical switch."
|
|
::= { swSystem 26}
|
|
|
|
swFCIPAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IP Address of the FC interface of this logical switch."
|
|
::= { swSystem 27 }
|
|
|
|
swFCIPMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IP Mask of the FC interface of this logical switch."
|
|
::= { swSystem 28 }
|
|
|
|
swIPv6Address OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPV6 address."
|
|
::= { swSystem 29 }
|
|
|
|
swIPv6Status OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
tentative (1),
|
|
preferred (2),
|
|
ipdeprecated (3),
|
|
inactive (4)
|
|
}
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The current status of ipv6 address."
|
|
::= { swSystem 30 }
|
|
|
|
swModel OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
switch7500 (1),
|
|
switch7500E (2),
|
|
other (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the switch is 7500 or 7500E ."
|
|
::= { swSystem 31 }
|
|
|
|
swTestString OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(1..255))
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "presence of this string represents test trap."
|
|
::= { swSystem 32 }
|
|
|
|
|
|
--
|
|
-- End of System Group
|
|
--
|
|
|
|
--
|
|
-- Fabric Group
|
|
--
|
|
swDomainID OBJECT-TYPE
|
|
SYNTAX SwDomainIndex
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The current Fibre Channel domain ID of the switch.
|
|
To set a new value, the switch (swAdmStatus) must be in
|
|
offline or testing state."
|
|
::= { swFabric 1 }
|
|
|
|
swPrincipalSwitch OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
yes (1),
|
|
no (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object indicates whether the switch is
|
|
the Principal switch as per FC-SW."
|
|
::= { swFabric 2 }
|
|
|
|
-- swFabric 3..7 are reserved
|
|
|
|
-- (immediate) Neighborhood ISL family
|
|
--
|
|
swNumNbs OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of Inter-Switch Links in the (immediate)
|
|
neighborhood."
|
|
::= { swFabric 8 }
|
|
|
|
swNbTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwNbEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This table contains the ISLs in the immediate
|
|
neighborhood of the switch."
|
|
::= { swFabric 9 }
|
|
|
|
swNbEntry OBJECT-TYPE
|
|
SYNTAX SwNbEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry containing each neighbor ISL parameters."
|
|
INDEX { swNbIndex }
|
|
::= { swNbTable 1 }
|
|
|
|
SwNbEntry ::= SEQUENCE {
|
|
swNbIndex SwNbIndex,
|
|
swNbMyPort SwPortIndex,
|
|
swNbRemDomain SwDomainIndex,
|
|
swNbRemPort SwPortIndex,
|
|
swNbBaudRate INTEGER,
|
|
swNbIslState INTEGER,
|
|
swNbIslCost Integer32,
|
|
swNbRemPortName OCTET STRING
|
|
}
|
|
|
|
swNbIndex OBJECT-TYPE
|
|
SYNTAX SwNbIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the neighbor ISL entry."
|
|
::= { swNbEntry 1 }
|
|
|
|
swNbMyPort OBJECT-TYPE
|
|
SYNTAX SwPortIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This is the port that has an ISL to another switch."
|
|
::= { swNbEntry 2 }
|
|
|
|
swNbRemDomain OBJECT-TYPE
|
|
SYNTAX SwDomainIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This is the Fibre Channel domain on the other end
|
|
of the ISL."
|
|
::= { swNbEntry 3 }
|
|
|
|
swNbRemPort OBJECT-TYPE
|
|
SYNTAX SwPortIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This is the port index on the other end of the ISL."
|
|
::= { swNbEntry 4 }
|
|
|
|
swNbBaudRate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other (1), -- none of below
|
|
oneEighth (2), -- 155 Mbaud
|
|
quarter (4), -- 266 Mbaud
|
|
half (8), -- 532 Mbaud
|
|
full (16), -- 1 Gbaud
|
|
double (32), -- 2 Gbaud
|
|
quadruple (64), -- 4 Gbaud
|
|
octuple (128), -- 8 Gbaud
|
|
decuple (256) -- 10 Gbaud
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The baud rate of the ISL."
|
|
::= { swNbEntry 5 }
|
|
|
|
swNbIslState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sw-down (0),
|
|
sw-init (1),
|
|
sw-internal2 (2),
|
|
sw-internal3 (3),
|
|
sw-internal4 (4),
|
|
sw-active (5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The current state of the ISL.
|
|
The swNbIslState will be 0 when ISL
|
|
is in incompatible state or port is a slave port."
|
|
::= { swNbEntry 6 }
|
|
|
|
swNbIslCost OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The current link cost of the ISL."
|
|
::= { swNbEntry 7 }
|
|
|
|
swNbRemPortName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The World_wide_Name of the remote port."
|
|
::= { swNbEntry 8 }
|
|
|
|
-- Fabric member information
|
|
--
|
|
swFabricMemTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwFabricMemEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This table contains information on the member
|
|
switches of a fabric. This may not be available on
|
|
all versions of Fabric OS."
|
|
::= { swFabric 10 }
|
|
|
|
swFabricMemEntry OBJECT-TYPE
|
|
SYNTAX SwFabricMemEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry containing each switch in the fabric."
|
|
INDEX { swFabricMemWwn }
|
|
::= { swFabricMemTable 1 }
|
|
|
|
SwFabricMemEntry ::= SEQUENCE {
|
|
swFabricMemWwn FcWwn,
|
|
swFabricMemDid SwDomainIndex,
|
|
swFabricMemName DisplayString,
|
|
swFabricMemEIP IpAddress,
|
|
swFabricMemFCIP IpAddress,
|
|
swFabricMemGWIP IpAddress,
|
|
swFabricMemType Integer32,
|
|
swFabricMemShortVersion OCTET STRING
|
|
}
|
|
swFabricMemWwn OBJECT-TYPE
|
|
SYNTAX FcWwn
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the World wide name of the
|
|
member switch."
|
|
::= { swFabricMemEntry 1 }
|
|
|
|
swFabricMemDid OBJECT-TYPE
|
|
SYNTAX SwDomainIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the domain id of the member
|
|
switch."
|
|
::= { swFabricMemEntry 2 }
|
|
|
|
swFabricMemName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the name of the member switch."
|
|
::= { swFabricMemEntry 3 }
|
|
|
|
swFabricMemEIP OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the ethernet IP address
|
|
of the member switch."
|
|
::= { swFabricMemEntry 4 }
|
|
swFabricMemFCIP OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the Fibre Channel IP address
|
|
of the member switch."
|
|
::= { swFabricMemEntry 5 }
|
|
|
|
swFabricMemGWIP OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the Gateway IP address
|
|
of the member switch."
|
|
::= { swFabricMemEntry 6 }
|
|
|
|
swFabricMemType OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the member switch type."
|
|
::= { swFabricMemEntry 7 }
|
|
|
|
swFabricMemShortVersion OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..24))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies Fabric OS version of
|
|
the member switch."
|
|
::= { swFabricMemEntry 8 }
|
|
|
|
swIDIDMode OBJECT-TYPE
|
|
SYNTAX INTEGER { enabled(1), disabled(2) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Status of Insistent Domain ID (IDID) mode. Status
|
|
indicating IDID mode is enabled or not."
|
|
::= { swFabric 11 }
|
|
|
|
swPmgrEventType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
create (0),
|
|
delete (1),
|
|
moveport (2),
|
|
fidchange (3),
|
|
basechange (4),
|
|
vfstatechange(6)
|
|
}
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Indicates Partition manager event type."
|
|
::= { swFabric 12 }
|
|
|
|
swPmgrEventTime OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE (0..64))
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the date and time when this pmgr
|
|
event occurred, in textual format."
|
|
::= { swFabric 13 }
|
|
|
|
swPmgrEventDescr OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE (0..64))
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the textual description of
|
|
the pmgr event."
|
|
::= { swFabric 14 }
|
|
|
|
swVfId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The Virtual fabric id."
|
|
::= { swFabric 15 }
|
|
|
|
--
|
|
-- SNMP Agent Configuration
|
|
--
|
|
|
|
-- swAgtCfg 1..10 are reserved
|
|
|
|
swAgtCmtyTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwAgtCmtyEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table that contains, one entry for each Community,
|
|
the access control and parameters of the Community."
|
|
::= { swAgtCfg 11 }
|
|
|
|
swAgtCmtyEntry OBJECT-TYPE
|
|
SYNTAX SwAgtCmtyEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry containing the Community parameters."
|
|
INDEX { swAgtCmtyIdx }
|
|
::= { swAgtCmtyTable 1 }
|
|
|
|
SwAgtCmtyEntry ::= SEQUENCE {
|
|
swAgtCmtyIdx Integer32,
|
|
swAgtCmtyStr DisplayString,
|
|
swAgtTrapRcp IpAddress,
|
|
swAgtTrapSeverityLevel SwSevType
|
|
}
|
|
|
|
swAgtCmtyIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..6)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the SNMPv1 Community entry."
|
|
::= { swAgtCmtyEntry 1 }
|
|
|
|
swAgtCmtyStr OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE (2..16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This is a Community string supported by the agent.
|
|
If a new value is set successfully, it takes effect
|
|
immediately."
|
|
::= { swAgtCmtyEntry 2 }
|
|
|
|
swAgtTrapRcp OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This is the trap recipient associated with the
|
|
Community. If a new value is set successfully, it takes
|
|
effect immediately."
|
|
::= { swAgtCmtyEntry 3 }
|
|
|
|
swAgtTrapSeverityLevel OBJECT-TYPE
|
|
SYNTAX SwSevType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This is the trap severity level associated with the
|
|
swAgtTrapRcp. The trap severity level in conjunction with
|
|
the an event's severity level. When an event occurs and if its
|
|
severity level is at or below the set value, the SNMP trap is
|
|
sent to configured trap recipients. The severity level is
|
|
limited to particular events. If a new value is set successfully,
|
|
it takes effect immediately."
|
|
::= { swAgtCmtyEntry 4 }
|
|
|
|
--
|
|
-- End of SNMP Agent Configuration Group
|
|
--
|
|
|
|
--
|
|
-- Fibre Channel Port Group
|
|
-- This group contains information about the physical state,
|
|
-- operational status, performance and error statistics of each
|
|
-- Fibre Channel port on the switch. A Fibre Channel port is one which
|
|
-- supports the Fibre Channel protocol. E.g. F_Port, E_Port, FL_Port.
|
|
--
|
|
|
|
swFCPortCapacity OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The maximum number of Fibre Channel ports on this
|
|
switch. It includes G_Port, F_Port, FL_Port and any other
|
|
types of Fibre Channel port."
|
|
::= { swFCport 1 }
|
|
|
|
swFCPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwFCPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table that contains, one entry for each switch port,
|
|
configuration and service parameters of the port."
|
|
::= { swFCport 2 }
|
|
|
|
swFCPortEntry OBJECT-TYPE
|
|
SYNTAX SwFCPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry containing the configuration and service
|
|
parameters of the switch port."
|
|
INDEX { swFCPortIndex }
|
|
::= { swFCPortTable 1 }
|
|
|
|
SwFCPortEntry ::= SEQUENCE {
|
|
swFCPortIndex SwPortIndex,
|
|
swFCPortType INTEGER,
|
|
swFCPortPhyState INTEGER,
|
|
swFCPortOpStatus INTEGER,
|
|
swFCPortAdmStatus INTEGER,
|
|
|
|
swFCPortLinkState INTEGER,
|
|
swFCPortTxType INTEGER,
|
|
|
|
-- the rest is mapped to gstat_t
|
|
swFCPortTxWords Counter32,
|
|
swFCPortRxWords Counter32,
|
|
swFCPortTxFrames Counter32,
|
|
swFCPortRxFrames Counter32,
|
|
swFCPortRxC2Frames Counter32,
|
|
swFCPortRxC3Frames Counter32,
|
|
swFCPortRxLCs Counter32,
|
|
swFCPortRxMcasts Counter32,
|
|
swFCPortTooManyRdys Counter32,
|
|
swFCPortNoTxCredits Counter32,
|
|
swFCPortRxEncInFrs Counter32,
|
|
swFCPortRxCrcs Counter32,
|
|
swFCPortRxTruncs Counter32,
|
|
swFCPortRxTooLongs Counter32,
|
|
swFCPortRxBadEofs Counter32,
|
|
swFCPortRxEncOutFrs Counter32,
|
|
swFCPortRxBadOs Counter32,
|
|
swFCPortC3Discards Counter32,
|
|
swFCPortMcastTimedOuts Counter32,
|
|
swFCPortTxMcasts Counter32,
|
|
|
|
-- LIP statistics
|
|
swFCPortLipIns Counter32,
|
|
swFCPortLipOuts Counter32,
|
|
swFCPortLipLastAlpa OCTET STRING,
|
|
|
|
-- new for V2.1
|
|
swFCPortWwn OCTET STRING,
|
|
|
|
-- new for V3.0
|
|
swFCPortSpeed INTEGER,
|
|
|
|
-- new for Port Name Feature.
|
|
swFCPortName DisplayString,
|
|
|
|
-- new for PortSpecifier Feature.
|
|
swFCPortSpecifier DisplayString,
|
|
|
|
-- new for portFlag Feature.
|
|
swFCPortFlag FcPortFlag,
|
|
|
|
-- Brocade port type.
|
|
swFCPortBrcdType INTEGER
|
|
}
|
|
|
|
swFCPortIndex OBJECT-TYPE
|
|
SYNTAX SwPortIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the switch port index.
|
|
Note that the value of a port index is 1 higher than the
|
|
port number labeled on the front panel.
|
|
E.g. port index 1 correspond to port number 0."
|
|
::= { swFCPortEntry 1 }
|
|
|
|
swFCPortType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
stitch (1),
|
|
flannel (2),
|
|
loom (3),
|
|
bloom (4),
|
|
rdbloom (5),
|
|
wormhole (6),
|
|
other (7),
|
|
unknown (8)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the type of switch port.
|
|
It may be of type stitch(1), flannel(2), loom(3) , bloom(4),rdbloom(5) or wormhole(6)."
|
|
::= { swFCPortEntry 2 }
|
|
|
|
swFCPortPhyState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noCard (1),
|
|
noTransceiver (2),
|
|
laserFault (3),
|
|
noLight (4),
|
|
noSync (5),
|
|
inSync (6),
|
|
portFault (7),
|
|
diagFault (8),
|
|
lockRef (9),
|
|
validating (10),
|
|
invalidModule (11),
|
|
unknown (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the physical state of
|
|
the port:
|
|
noCard(1) no card present in this switch slot;
|
|
noTransceiver(2) no Transceiver module in this port.
|
|
noGbic(2) was used previously. Transceiver
|
|
is the generic name for GBIC, SFP etc.;
|
|
laserFault(3) the module is signaling a laser fault
|
|
(defective Transceiver);
|
|
noLight(4) the module is not receiving light;
|
|
noSync(5) the module is receiving light but is
|
|
out of sync;
|
|
inSync(6) the module is receiving light and is
|
|
in sync;
|
|
portFault(7) the port is marked faulty (defective
|
|
Transceiver, cable or device);
|
|
diagFault(8) the port failed diagnostics (defective
|
|
G_Port or FL_Port card or motherboard);
|
|
lockRef(9) the port is locking to the reference
|
|
signal.
|
|
validating(10) Validation is in progress
|
|
invalidModule(11) Invalid SFP
|
|
unknown(255) unknown.
|
|
"
|
|
::= { swFCPortEntry 3 }
|
|
|
|
swFCPortOpStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (0),
|
|
online (1),
|
|
offline (2),
|
|
testing (3),
|
|
faulty (4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the operational status of
|
|
the port. The online(1) state indicates that user frames
|
|
can be passed. The unknown(0) state indicates that likely
|
|
the port module is physically absent (see swFCPortPhyState)."
|
|
::= { swFCPortEntry 4 }
|
|
|
|
swFCPortAdmStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online (1),
|
|
offline (2),
|
|
testing (3),
|
|
faulty (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The desired state of the port. A management station
|
|
may place the port in a desired state by setting this
|
|
object accordingly. The testing(3) state indicates that
|
|
no user frames can be passed. As the result of
|
|
either explicit management action or per configuration
|
|
information accessible by the switch, swFCPortAdmStatus is
|
|
then changed to either the online(1) or testing(3)
|
|
states, or remains in the offline(2) state."
|
|
::= { swFCPortEntry 5 }
|
|
|
|
swFCPortLinkState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled (1),
|
|
disabled (2),
|
|
loopback (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This object indicates the link state of the port.
|
|
The value may be:
|
|
enabled(1) - port is allowed to participate in the FC-PH
|
|
protocol with its attached port (or ports if it is
|
|
in a FC-AL loop);
|
|
disabled(2) - the port is not allowed to participate in
|
|
the FC-PH protocol with its attached port(s);
|
|
loopback(3) - the port may transmit frames through an
|
|
internal path to verify the health of the transmitter
|
|
and receiver path.
|
|
|
|
Note that when the port's link state changes, its
|
|
operational status (swFCPortOpStatus) will be affected."
|
|
::= { swFCPortEntry 6 }
|
|
|
|
swFCPortTxType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
lw (2),
|
|
sw (3),
|
|
ld (4),
|
|
cu (5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object indicates the media transmitter type of
|
|
the port. The value may be:
|
|
unknown(1) cannot determined to the port driver
|
|
lw(2) long wave laser
|
|
sw(3) short wave laser
|
|
ld(4) long wave LED
|
|
cu(5) copper (electrical)."
|
|
::= { swFCPortEntry 7 }
|
|
|
|
-- counters
|
|
swFCPortTxWords OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object counts the number of Fibre Channel
|
|
words that the port has transmitted."
|
|
::= { swFCPortEntry 11 }
|
|
|
|
swFCPortRxWords OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object counts the number of Fibre Channel
|
|
words that the port has received."
|
|
::= { swFCPortEntry 12 }
|
|
|
|
swFCPortTxFrames OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object counts the number of (Fibre Channel)
|
|
frames that the port has transmitted."
|
|
::= { swFCPortEntry 13 }
|
|
|
|
swFCPortRxFrames OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object counts the number of (Fibre Channel)
|
|
frames that the port has received."
|
|
::= { swFCPortEntry 14 }
|
|
|
|
swFCPortRxC2Frames OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object counts the number of Class 2
|
|
frames that the port has received."
|
|
::= { swFCPortEntry 15 }
|
|
|
|
swFCPortRxC3Frames OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object counts the number of Class 3
|
|
frames that the port has received."
|
|
::= { swFCPortEntry 16 }
|
|
|
|
swFCPortRxLCs OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object counts the number of Link Control
|
|
frames that the port has received."
|
|
::= { swFCPortEntry 17 }
|
|
|
|
swFCPortRxMcasts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object counts the number of Multicast
|
|
frames that the port has received."
|
|
::= { swFCPortEntry 18 }
|
|
|
|
swFCPortTooManyRdys OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object counts the number of times when RDYs
|
|
exceeds the frames received."
|
|
::= { swFCPortEntry 19 }
|
|
|
|
swFCPortNoTxCredits OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object counts the number of times when the
|
|
transmit credit has reached zero."
|
|
::= { swFCPortEntry 20 }
|
|
|
|
swFCPortRxEncInFrs OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object counts the number of encoding error or
|
|
disparity error inside frames received."
|
|
::= { swFCPortEntry 21 }
|
|
|
|
swFCPortRxCrcs OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object counts the number of CRC errors
|
|
detected for frames received."
|
|
::= { swFCPortEntry 22 }
|
|
|
|
swFCPortRxTruncs OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object counts the number of truncated
|
|
frames that the port has received."
|
|
::= { swFCPortEntry 23 }
|
|
|
|
swFCPortRxTooLongs OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object counts the number of received frames that
|
|
are too long."
|
|
::= { swFCPortEntry 24 }
|
|
|
|
swFCPortRxBadEofs OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object counts the number of received frames that
|
|
have bad EOF delimiter."
|
|
::= { swFCPortEntry 25 }
|
|
|
|
swFCPortRxEncOutFrs OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object counts the number of encoding error or
|
|
disparity error outside frames received."
|
|
::= { swFCPortEntry 26 }
|
|
|
|
swFCPortRxBadOs OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object counts the number of invalid Ordered
|
|
Sets received."
|
|
::= { swFCPortEntry 27 }
|
|
|
|
swFCPortC3Discards OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object counts the number of Class 3
|
|
frames that the port has discarded."
|
|
::= { swFCPortEntry 28 }
|
|
|
|
swFCPortMcastTimedOuts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object counts the number of Multicast
|
|
frames that has been timed out."
|
|
::= { swFCPortEntry 29 }
|
|
|
|
swFCPortTxMcasts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object counts the number of Multicast
|
|
frames that has been transmitted."
|
|
::= { swFCPortEntry 30 }
|
|
|
|
-- LIP statistics
|
|
swFCPortLipIns OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object counts the number of Loop Initializations
|
|
that has been initiated by loop devices attached."
|
|
::= { swFCPortEntry 31 }
|
|
|
|
swFCPortLipOuts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object counts the number of Loop Initializations
|
|
that has been initiated by the port."
|
|
::= { swFCPortEntry 32 }
|
|
|
|
swFCPortLipLastAlpa OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object indicates the Physical Address (AL_PA)
|
|
of the loop device that initiated the last
|
|
Loop Initialization."
|
|
::= { swFCPortEntry 33 }
|
|
|
|
swFCPortWwn OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The World_wide_Name of the Fibre Channel port.
|
|
The contents of an instance are in the IEEE extended format
|
|
as specified in FC-PH; the 12-bit port identifier represents
|
|
the port number within the switch."
|
|
::= { swFCPortEntry 34 }
|
|
|
|
swFCPortSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
one-GB (1),
|
|
two-GB (2),
|
|
auto-Negotiate (3),
|
|
four-GB (4),
|
|
eight-GB (5),
|
|
ten-GB (6),
|
|
unknown (7)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The desired baud rate for the port. It can have the
|
|
values of 1GB (1), 2GB (2), Auto-Negotiate (3), 4GB (4), 8GB (5),
|
|
or 10GB (6). Some of the above values may not be supported
|
|
by all type of switches."
|
|
::= { swFCPortEntry 35 }
|
|
|
|
swFCPortName OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "A string indicates the name of the addressed port.
|
|
The names should be persistent across switch reboots.
|
|
Port names do not have to be unique within a switch or
|
|
within a fabric."
|
|
::= { swFCPortEntry 36 }
|
|
|
|
swFCPortSpecifier OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This string indicates the physical port number of the addressed port.
|
|
The format of the string is: <slot>/port, where 'slot' being
|
|
present only for bladed systems.
|
|
"
|
|
::= { swFCPortEntry 37 }
|
|
|
|
-- FC port status flag
|
|
|
|
swFCPortFlag OBJECT-TYPE
|
|
SYNTAX FcPortFlag
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A bit map of port status flags which includes the information of port type.
|
|
Currently this will indicate if the port is virtual or physical."
|
|
::= { swFCPortEntry 38 }
|
|
|
|
swFCPortBrcdType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
other (2),
|
|
fl-port (3), -- public loop
|
|
f-port (4), -- fabric port
|
|
e-port (5), -- fabric expansion port
|
|
g-port (6), -- generic fabric port
|
|
ex-port (7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Brocade port type."
|
|
::= { swFCPortEntry 39 }
|
|
|
|
|
|
--
|
|
-- End of Fibre Channel Port group
|
|
--
|
|
|
|
|
|
|
|
--
|
|
-- The Name Server Database group
|
|
--
|
|
|
|
swNsLocalNumEntry OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of local Name Server entries."
|
|
::= { swNs 1 }
|
|
|
|
swNsLocalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwNsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The table of local Name Server entries."
|
|
::= { swNs 2 }
|
|
|
|
swNsLocalEntry OBJECT-TYPE
|
|
SYNTAX SwNsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry of the local Name Server database."
|
|
INDEX { swNsEntryIndex }
|
|
::= { swNsLocalTable 1 }
|
|
|
|
SwNsEntry ::= SEQUENCE {
|
|
swNsEntryIndex Integer32,
|
|
swNsPortID OCTET STRING,
|
|
swNsPortType INTEGER,
|
|
swNsPortName FcWwn,
|
|
swNsPortSymb OCTET STRING,
|
|
swNsNodeName FcWwn,
|
|
swNsNodeSymb OCTET STRING,
|
|
swNsIPA OCTET STRING,
|
|
swNsIpAddress OCTET STRING,
|
|
swNsCos INTEGER,
|
|
swNsFc4 OCTET STRING,
|
|
swNsIpNxPort OCTET STRING,
|
|
swNsWwn OCTET STRING,
|
|
swNsHardAddr OCTET STRING
|
|
}
|
|
|
|
swNsEntryIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The object identifies the Name Server database entry."
|
|
::= { swNsLocalEntry 1 }
|
|
|
|
swNsPortID OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The object identifies the Fibre Channel port address
|
|
ID of the entry."
|
|
::= { swNsLocalEntry 2 }
|
|
|
|
swNsPortType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
-- unknown (0),
|
|
nPort (1),
|
|
nlPort (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The object identifies the type of port: N_Port,
|
|
NL_Port, etc., for this entry. The type is defined in FC-GS-2."
|
|
::= { swNsLocalEntry 3 }
|
|
|
|
swNsPortName OBJECT-TYPE
|
|
SYNTAX FcWwn
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The object identifies the Fibre Channel World_wide
|
|
Name of the port entry."
|
|
::= { swNsLocalEntry 4 }
|
|
|
|
swNsPortSymb OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The object identifies the contents of a Symbolic Name
|
|
of the port entry. In FC-GS-2, a Symbolic Name consists of
|
|
a byte array of 1 through 255 bytes, and the first byte of the
|
|
array specifies the length of its 'contents'.
|
|
This object variable corresponds to the 'contents' of the
|
|
Symbolic Name, without the first byte."
|
|
::= { swNsLocalEntry 5 }
|
|
|
|
swNsNodeName OBJECT-TYPE
|
|
SYNTAX FcWwn
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The object identifies the Fibre Channel World_wide
|
|
Name of the associated node as defined in FC-GS-2."
|
|
::= { swNsLocalEntry 6 }
|
|
|
|
swNsNodeSymb OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The object identifies the contents of a Symbolic Name
|
|
of the the node associated with the entry. In FC-GS-2,
|
|
a Symbolic Name consists of a byte array of 1 through 255
|
|
bytes, and the first byte of the array specifies the length
|
|
of its 'contents'.
|
|
This object variable corresponds to the 'contents' of the
|
|
Symbolic Name, without the first byte (specifying the length)."
|
|
::= { swNsLocalEntry 7 }
|
|
|
|
swNsIPA OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The object identifies the Initial Process Associator
|
|
of the node for the entry as defined in FC-GS-2."
|
|
::= { swNsLocalEntry 8 }
|
|
|
|
swNsIpAddress OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The object identifies the IP address of the node
|
|
for the entry as defined in FC-GS-2. The format of the address
|
|
is in IPv6."
|
|
::= { swNsLocalEntry 9 }
|
|
|
|
swNsCos OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
-- class-unknown (0),
|
|
class-F (1),
|
|
class-1 (2),
|
|
class-F-1 (3),
|
|
class-2 (4),
|
|
class-F-2 (5),
|
|
class-1-2 (6),
|
|
class-F-1-2 (7),
|
|
class-3 (8),
|
|
class-F-3 (9),
|
|
class-1-3 (10),
|
|
class-F-1-3 (11),
|
|
class-2-3 (12),
|
|
class-F-2-3 (13),
|
|
class-1-2-3 (14),
|
|
class-F-1-2-3 (15)
|
|
-- more to enumerate in future.
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The object identifies the class of services supported
|
|
by the port. The value is a bit-map defined as follows:
|
|
o bit 0 is class F,
|
|
o bit 1 is class 1,
|
|
o bit 2 is class 2,
|
|
o bit 3 is class 3,
|
|
o bit 4 is class 4, etc."
|
|
::= { swNsLocalEntry 10 }
|
|
|
|
swNsFc4 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The object identifies the FC-4s supported
|
|
by the port as defined in FC-GS-2."
|
|
::= { swNsLocalEntry 11 }
|
|
|
|
swNsIpNxPort OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The object identifies IpAddress of the Nx_port for the entry."
|
|
::= { swNsLocalEntry 12 }
|
|
|
|
swNsWwn OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The object identifies the World Wide Name (WWN) of the Fx_port
|
|
for the entry."
|
|
::= { swNsLocalEntry 13 }
|
|
|
|
swNsHardAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(3))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The object identifies the 24-bit hard address of the node
|
|
for the entry."
|
|
::= { swNsLocalEntry 14 }
|
|
|
|
--
|
|
-- End of Fibre Channel Name Server group
|
|
--
|
|
|
|
-- #######################################################################
|
|
--
|
|
-- Event Group - to map the errLog
|
|
--
|
|
-- NOTE
|
|
-- Logically, swEventTable is separate from the error log since it is
|
|
-- essentially a view of the error log within a particular time window.
|
|
-- The value of swEventIndex shall indicate the event number that has
|
|
-- occurred since the switch booted. The value will range from 1 through
|
|
-- 2147383647 (2^31 - 1).
|
|
--
|
|
-- #######################################################################
|
|
|
|
swEventTrapLevel OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none (0),
|
|
critical (1),
|
|
error (2),
|
|
warning (3),
|
|
informational (4),
|
|
debug (5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION "swAgtTrapSeverityLevel, in absence of
|
|
swEventTrapLevel, specifies the Trap Severity Level of each
|
|
defined trap recipient host.
|
|
This object specifies the swEventTrap level in
|
|
conjunction with an event's severity level. When an event
|
|
occurs and if its severity level is at or below the value
|
|
specified by this object instance, the agent will send
|
|
the associated swEventTrap to configured recipients."
|
|
::= { swEvent 1 }
|
|
|
|
-- { swEvent 2..3 are reserved }
|
|
|
|
swEventNumEntries OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of entries in the Event Table."
|
|
::= { swEvent 4 }
|
|
|
|
swEventTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwEventEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The table of event entries."
|
|
::= { swEvent 5 }
|
|
|
|
swEventEntry OBJECT-TYPE
|
|
SYNTAX SwEventEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry of the event table."
|
|
INDEX { swEventIndex }
|
|
|
|
::= { swEventTable 1 }
|
|
|
|
SwEventEntry ::= SEQUENCE {
|
|
swEventIndex Integer32,
|
|
swEventTimeInfo DisplayString,
|
|
swEventLevel INTEGER,
|
|
swEventRepeatCount Integer32,
|
|
swEventDescr DisplayString,
|
|
swEventVfId Integer32
|
|
}
|
|
|
|
swEventIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the event entry."
|
|
::= { swEventEntry 1 }
|
|
|
|
swEventTimeInfo OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE (0..64))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the date and time when this
|
|
event occurred, in textual format."
|
|
::= { swEventEntry 2 }
|
|
|
|
swEventLevel OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
critical (1),
|
|
error (2),
|
|
warning (3),
|
|
informational (4),
|
|
debug (5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the severity level of this
|
|
event entry."
|
|
::= { swEventEntry 3 }
|
|
|
|
swEventRepeatCount OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies how many times this particular
|
|
event has occurred."
|
|
::= { swEventEntry 4 }
|
|
|
|
swEventDescr OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the textual description of
|
|
the event."
|
|
::= { swEventEntry 5 }
|
|
|
|
swEventVfId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the Virtual fabric id."
|
|
::= { swEventEntry 6 }
|
|
|
|
--
|
|
-- End of Fibre Channel Event Group
|
|
--
|
|
|
|
--
|
|
-- swFwSystem
|
|
-- Fabric Watch subsystem
|
|
-- ###########################################################################
|
|
-- Fabric Watch subsystem consists of two tables
|
|
-- SwFwClassAreaEntry contains control information for a particular class/area's
|
|
-- thresholds. These thresholds are contained in SwFwThresholdEntry.
|
|
-- ###########################################################################
|
|
|
|
-- valid action matrix
|
|
-- ###########################################################################
|
|
-- The valid action matrix is arrived out of the combination of the configured
|
|
-- alarm matrix such as Errlog-1(El), SnmpTrap-2(St), PortLogLock-4(Pl),
|
|
-- RapiTrap-8(Rn), EmailAlert-16, PortFencing-32(Pf)
|
|
-- ###########################################################################
|
|
SwFwActs ::= INTEGER {
|
|
swFwNoAction(0),
|
|
swFwErrlog(1),
|
|
swFwSnmptrap(2),
|
|
swFwErrlogSnmptrap(3),
|
|
swFwPortloglock(4),
|
|
swFwErrlogPortloglock(5),
|
|
swFwSnmptrapPortloglock(6),
|
|
swFwErrlogSnmptrapPortloglock(7),
|
|
swFwRn(8),
|
|
swFwElRn(9),
|
|
swFwStRn(10),
|
|
swFwElStRn(11),
|
|
swFwPlRn(12),
|
|
swFwElPlRn(13),
|
|
swFwStPlRn(14),
|
|
swFwElStPlRn(15),
|
|
swFwMailAlert(16),
|
|
swFwMailAlertErrlog(17),
|
|
swFwMailAlertSnmptrap(18),
|
|
swFwMailAlertErrlogSnmptrap(19),
|
|
swFwMailAlertPortloglock(20),
|
|
swFwMailAlertErrlogPortloglock(21),
|
|
swFwMailAlertSnmptrapPortloglock(22),
|
|
swFwMailAlertErrlogSnmptrapPortloglock(23),
|
|
swFwMailAlertRn(24),
|
|
swFwElMailAlertRn(25),
|
|
swFwMailAlertStRn(26),
|
|
swFwMailAlertElStRn(27),
|
|
swFwMailAlertPlRn(28),
|
|
swFwMailAlertElPlRn(29),
|
|
swFwMailAlertStPlRn(30),
|
|
swFwMailAlertElStPlRn(31),
|
|
swFwPf(32),
|
|
swFwElPf(33),
|
|
swFwStPf(34),
|
|
swFwElStPf(35),
|
|
swFwPlPf(36),
|
|
swFwElPlPf(37),
|
|
swFwStPlPf(38),
|
|
swFwElStPlPf(39),
|
|
swFwRnPf(40),
|
|
swFwElRnPf(41),
|
|
swFwStRnPf(42),
|
|
swFwElStRnPf(43),
|
|
swFwPlRnPf(44),
|
|
swFwElPlRnPf(45),
|
|
swFwStPlRnPf(46),
|
|
swFwElStPlRnPf(47),
|
|
swFwMailAlertPf(48),
|
|
swFwMailAlertElPf(49),
|
|
swFwMailAlertStPf(50),
|
|
swFwMailAlertElStPf(51),
|
|
swFwMailAlertPlPf(52),
|
|
swFwMailAlertElPlPf(53),
|
|
swFwMailAlertStPlPf(54),
|
|
swFwMailAlertElStPlPf(55),
|
|
swFwMailAlertRnPf(56),
|
|
swFwMailAlertElRnPf(57),
|
|
swFwMailAlertStRnPf(58),
|
|
swFwMailAlertElStRnPf(59),
|
|
swFwMailAlertPlRnPf(60),
|
|
swFwMailAlertElPlRnPf(61),
|
|
swFwMailAlertStPlRnPf(62),
|
|
swFwMailAlertElStPlRnPf(63)
|
|
}
|
|
|
|
-- variable for threshold values or action matrix level
|
|
SwFwLevels ::= INTEGER {
|
|
swFwReserved(1),
|
|
swFwDefault(2),
|
|
swFwCustom(3)
|
|
}
|
|
|
|
-- classes and areas index
|
|
SwFwClassesAreas ::= INTEGER {
|
|
swFwEnvTemp(1),
|
|
swFwEnvFan(2),
|
|
swFwEnvPs(3),
|
|
swFwTransceiverTemp(4),
|
|
swFwTransceiverRxp(5),
|
|
swFwTransceiverTxp(6),
|
|
swFwTransceiverCurrent(7),
|
|
swFwPortLink(8),
|
|
swFwPortSync(9),
|
|
swFwPortSignal(10),
|
|
swFwPortPe(11),
|
|
swFwPortWords(12),
|
|
swFwPortCrcs(13),
|
|
swFwPortRXPerf(14),
|
|
swFwPortTXPerf(15),
|
|
swFwPortState(16),
|
|
swFwFabricEd(17),
|
|
swFwFabricFr(18),
|
|
swFwFabricDi(19),
|
|
swFwFabricSc(20),
|
|
swFwFabricZc(21),
|
|
swFwFabricFq(22),
|
|
swFwFabricFl(23),
|
|
swFwFabricGs(24),
|
|
swFwEPortLink(25),
|
|
swFwEPortSync(26),
|
|
swFwEPortSignal(27),
|
|
swFwEPortPe(28),
|
|
swFwEPortWords(29),
|
|
swFwEPortCrcs(30),
|
|
swFwEPortRXPerf(31),
|
|
swFwEPortTXPerf(32),
|
|
swFwEPortState(33),
|
|
swFwFCUPortLink(34),
|
|
swFwFCUPortSync(35),
|
|
swFwFCUPortSignal(36),
|
|
swFwFCUPortPe(37),
|
|
swFwFCUPortWords(38),
|
|
swFwFCUPortCrcs(39),
|
|
swFwFCUPortRXPerf(40),
|
|
swFwFCUPortTXPerf(41),
|
|
swFwFCUPortState(42),
|
|
swFwFOPPortLink(43),
|
|
swFwFOPPortSync(44),
|
|
swFwFOPPortSignal(45),
|
|
swFwFOPPortPe(46),
|
|
swFwFOPPortWords(47),
|
|
swFwFOPPortCrcs(48),
|
|
swFwFOPPortRXPerf(49),
|
|
swFwFOPPortTXPerf(50),
|
|
swFwFOPPortState(51),
|
|
swFwPerfALPACRC(52),
|
|
swFwPerfEToECRC(53),
|
|
swFwPerfEToERxCnt(54),
|
|
swFwPerfEToETxCnt(55),
|
|
swFwPerffltCusDef(56),
|
|
swFwTransceiverVoltage(57),
|
|
swFwSecTelnetViolations(58),
|
|
swFwSecHTTPViolations(59),
|
|
swFwSecAPIViolations(60),
|
|
swFwSecRSNMPViolations(61),
|
|
swFwSecWSNMPViolations(62),
|
|
swFwSecSESViolations(63),
|
|
swFwSecMSViolations(64),
|
|
swFwSecSerialViolations(65),
|
|
swFwSecFPViolations(66),
|
|
swFwSecSCCViolations(67),
|
|
swFwSecDCCViolations(68),
|
|
swFwSecLoginViolations(69),
|
|
swFwSecInvalidTS(70),
|
|
swFwSecInvalidSign(71),
|
|
swFwSecInvalidCert(72),
|
|
swFwSecSlapFail(73),
|
|
swFwSecSlapBadPkt(74),
|
|
swFwSecTSOutSync(75),
|
|
swFwSecNoFcs(76),
|
|
swFwSecIncompDB(77),
|
|
swFwSecIllegalCmd(78),
|
|
swFwSAMTotalDownTime(79),
|
|
swFwSAMTotalUpTime(80),
|
|
swFwSAMDurationOfOccur(81),
|
|
swFwSAMFreqOfOccur(82),
|
|
swFwResourceFlash(83),
|
|
swFwEPortUtil(84),
|
|
swFwEPortPktl(85),
|
|
swFwPortLr(86),
|
|
swFwEPortLr(87),
|
|
swFwFCUPortLr(88),
|
|
swFwFOPPortLr(89),
|
|
swFwPortC3Discard(90),
|
|
swFwEPortC3Discard(91),
|
|
swFwFCUPortC3Discard(92),
|
|
swFwFOPPortC3Discard(93),
|
|
swFwVEPortStateChange(94),
|
|
swFwVEPortUtil(95),
|
|
swFwVEPortPktLoss(96),
|
|
swFwEPortTrunkUtil(97),
|
|
swFwFCUPortTrunkUtil(98),
|
|
swFwFOPPortTrunkUtil(99),
|
|
swFwCPUMemUsage(100)
|
|
|
|
}
|
|
|
|
-- write only variable for applying or canceling
|
|
-- values or action matrix changes
|
|
SwFwWriteVals ::= INTEGER {
|
|
swFwCancelWrite(1),
|
|
swFwApplyWrite(2)
|
|
}
|
|
|
|
-- timebase for thresholds
|
|
SwFwTimebase ::= INTEGER {
|
|
swFwTbNone(1),
|
|
swFwTbSec(2),
|
|
swFwTbMin(3),
|
|
swFwTbHour(4),
|
|
swFwTbDay(5)
|
|
}
|
|
|
|
-- status for thresholds
|
|
SwFwStatus ::= INTEGER {
|
|
disabled(1),
|
|
enabled(2)
|
|
}
|
|
|
|
-- possible events available
|
|
SwFwEvent ::= INTEGER {
|
|
started(1),
|
|
changed(2),
|
|
exceeded(3),
|
|
below(4),
|
|
above(5),
|
|
inBetween(6)
|
|
}
|
|
|
|
-- behavior type for thresholds
|
|
SwFwBehavior ::= INTEGER {
|
|
triggered(1),
|
|
continuous(2)
|
|
}
|
|
|
|
-- state type for last events
|
|
SwFwState ::= INTEGER {
|
|
swFwInformative(1),
|
|
swFwNormal(2),
|
|
swFwFaulty(3)
|
|
}
|
|
|
|
-- license state
|
|
SwFwLicense ::= INTEGER {
|
|
swFwLicensed(1),
|
|
swFwNotLicensed(2)
|
|
}
|
|
|
|
-- This is the first of the elements declared for Fabric Watch :
|
|
-- one scalar & two tables
|
|
-- A scalar, swFwFabricWatchLicense is used to tell is if the switch has
|
|
-- proper license for Fabric Watch. Please refer to Fabric Watch
|
|
-- documentation for further information.
|
|
-- One table contains classArea information such as threshold unit string,
|
|
-- time base, low thresholds, etc. The other table contains individual
|
|
-- threshold information such as name, label, last event, etc.
|
|
-- Please refer to Fabric Watch documentation for further information.
|
|
|
|
-- license scalar
|
|
swFwFabricWatchLicense OBJECT-TYPE
|
|
SYNTAX SwFwLicense
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "tells if licensed or not."
|
|
::= { swFwSystem 1 }
|
|
|
|
-- classArea table
|
|
swFwClassAreaTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwFwClassAreaEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The table of classes and areas."
|
|
::= { swFwSystem 2 }
|
|
|
|
swFwClassAreaEntry OBJECT-TYPE
|
|
SYNTAX SwFwClassAreaEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry of the classes and areas."
|
|
INDEX { swFwClassAreaIndex }
|
|
::= { swFwClassAreaTable 1 }
|
|
|
|
SwFwClassAreaEntry ::= SEQUENCE {
|
|
swFwClassAreaIndex SwFwClassesAreas,
|
|
swFwWriteThVals SwFwWriteVals,
|
|
swFwDefaultUnit DisplayString,
|
|
swFwDefaultTimebase SwFwTimebase,
|
|
swFwDefaultLow Integer32,
|
|
swFwDefaultHigh Integer32,
|
|
swFwDefaultBufSize Integer32,
|
|
swFwCustUnit DisplayString,
|
|
swFwCustTimebase SwFwTimebase,
|
|
swFwCustLow Integer32,
|
|
swFwCustHigh Integer32,
|
|
swFwCustBufSize Integer32,
|
|
swFwThLevel SwFwLevels,
|
|
swFwWriteActVals SwFwWriteVals,
|
|
swFwDefaultChangedActs SwFwActs,
|
|
swFwDefaultExceededActs SwFwActs,
|
|
swFwDefaultBelowActs SwFwActs,
|
|
swFwDefaultAboveActs SwFwActs,
|
|
swFwDefaultInBetweenActs SwFwActs,
|
|
swFwCustChangedActs SwFwActs,
|
|
swFwCustExceededActs SwFwActs,
|
|
swFwCustBelowActs SwFwActs,
|
|
swFwCustAboveActs SwFwActs,
|
|
swFwCustInBetweenActs SwFwActs,
|
|
swFwValidActs SwFwActs,
|
|
swFwActLevel SwFwLevels
|
|
}
|
|
|
|
swFwClassAreaIndex OBJECT-TYPE
|
|
SYNTAX SwFwClassesAreas
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the class type."
|
|
::= { swFwClassAreaEntry 1 }
|
|
|
|
-- this variable is used to apply or cancel
|
|
-- changes made to swFwCustUnit, swFwCustTimebase, swFwCustLow,
|
|
-- swFwCustHigh, swFwCustBufSize.
|
|
-- read of this variable will always return cancel.
|
|
swFwWriteThVals OBJECT-TYPE
|
|
SYNTAX SwFwWriteVals
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This object is set to apply the value changes."
|
|
::= { swFwClassAreaEntry 2 }
|
|
|
|
-- {swFwDefaultUnit, swFwDefaultTimebase, swFwDefaultMin, and swFwDefaultMax}
|
|
-- {swFwCustUnit, swFwCustTimebase, swFwCustMin, and swFwCustMax}
|
|
-- are grouped together to be applied to give threshold areas as in
|
|
--- Default and Cust. Which of default, or custom groups applies depends
|
|
--- on swFwThLevel.
|
|
swFwDefaultUnit OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "A Default unit string name for a threshold area."
|
|
::= { swFwClassAreaEntry 3 }
|
|
|
|
swFwDefaultTimebase OBJECT-TYPE
|
|
SYNTAX SwFwTimebase
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "A Default timebase for the current threshold counter."
|
|
::= { swFwClassAreaEntry 4 }
|
|
|
|
swFwDefaultLow OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "A Default low threshold value."
|
|
::= { swFwClassAreaEntry 5 }
|
|
|
|
swFwDefaultHigh OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "A Default high threshold value."
|
|
::= { swFwClassAreaEntry 6 }
|
|
|
|
swFwDefaultBufSize OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "A Default buffer size value."
|
|
::= { swFwClassAreaEntry 7 }
|
|
|
|
swFwCustUnit OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "A custom unit string name for a threshold area."
|
|
::= { swFwClassAreaEntry 8 }
|
|
|
|
swFwCustTimebase OBJECT-TYPE
|
|
SYNTAX SwFwTimebase
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "A custom timebase for the current threshold counter."
|
|
::= { swFwClassAreaEntry 9 }
|
|
|
|
swFwCustLow OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "A custom low threshold value."
|
|
::= { swFwClassAreaEntry 10 }
|
|
|
|
swFwCustHigh OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "A custom high threshold value."
|
|
::= { swFwClassAreaEntry 11 }
|
|
|
|
swFwCustBufSize OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "A custom buffer size value."
|
|
::= { swFwClassAreaEntry 12 }
|
|
|
|
-- swFwThLevel is used to point to current level for classArea
|
|
-- values. It is either default or custom.
|
|
swFwThLevel OBJECT-TYPE
|
|
SYNTAX SwFwLevels
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "A level where all the threshold values are set at."
|
|
::= { swFwClassAreaEntry 13 }
|
|
|
|
-- this variable is used to apply or cancel
|
|
-- changes made to swFwCustUnit, swFwCustTimebase, swFwCustLow,
|
|
-- swFwCustHigh, swFwCustBufSize.
|
|
-- read of this variable will always return cancel.
|
|
swFwWriteActVals OBJECT-TYPE
|
|
SYNTAX SwFwWriteVals
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This object is set to apply act value changes."
|
|
::= { swFwClassAreaEntry 14 }
|
|
|
|
-- {swFwDefaultChangedActs, swFwDefaultExceededActs, swFwDefaultBelowActs,
|
|
-- and swFwDefaultAboveActs} and {swFwCustChangedActs, swFwCustExceededActs,
|
|
-- swFwCustBelowActs, and swFwCustAboveActs} are grouped together to be
|
|
-- applied to give threshold areas as in default and cust. Which of
|
|
-- default, or custom groups applies depends on swFwThLevel.
|
|
swFwDefaultChangedActs OBJECT-TYPE
|
|
SYNTAX SwFwActs
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Default action matrix for changed event."
|
|
::= { swFwClassAreaEntry 15 }
|
|
|
|
swFwDefaultExceededActs OBJECT-TYPE
|
|
SYNTAX SwFwActs
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Default action matrix for exceeded event."
|
|
::= { swFwClassAreaEntry 16 }
|
|
|
|
swFwDefaultBelowActs OBJECT-TYPE
|
|
SYNTAX SwFwActs
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Default action matrix for below event."
|
|
::= { swFwClassAreaEntry 17 }
|
|
|
|
swFwDefaultAboveActs OBJECT-TYPE
|
|
SYNTAX SwFwActs
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Default action matrix for above event."
|
|
::= { swFwClassAreaEntry 18 }
|
|
|
|
swFwDefaultInBetweenActs OBJECT-TYPE
|
|
SYNTAX SwFwActs
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Default action matrix for in-between event."
|
|
::= { swFwClassAreaEntry 19 }
|
|
|
|
swFwCustChangedActs OBJECT-TYPE
|
|
SYNTAX SwFwActs
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "custom action matrix for changed event."
|
|
::= { swFwClassAreaEntry 20 }
|
|
|
|
swFwCustExceededActs OBJECT-TYPE
|
|
SYNTAX SwFwActs
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "custom action matrix for exceeded event."
|
|
::= { swFwClassAreaEntry 21 }
|
|
|
|
swFwCustBelowActs OBJECT-TYPE
|
|
SYNTAX SwFwActs
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "custom action matrix for below event."
|
|
::= { swFwClassAreaEntry 22 }
|
|
|
|
swFwCustAboveActs OBJECT-TYPE
|
|
SYNTAX SwFwActs
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "custom action matrix for above event."
|
|
::= { swFwClassAreaEntry 23 }
|
|
|
|
swFwCustInBetweenActs OBJECT-TYPE
|
|
SYNTAX SwFwActs
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "custom action matrix for in-between event."
|
|
::= { swFwClassAreaEntry 24 }
|
|
|
|
swFwValidActs OBJECT-TYPE
|
|
SYNTAX SwFwActs
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "matrix of valid acts for an class/area."
|
|
::= { swFwClassAreaEntry 25 }
|
|
|
|
-- swFwActLevel is used to point to current level for classArea
|
|
-- action matrix. It is either default or custom.
|
|
swFwActLevel OBJECT-TYPE
|
|
SYNTAX SwFwLevels
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "A level where all the actions are set at."
|
|
::= { swFwClassAreaEntry 26 }
|
|
|
|
-- table for individual threshold
|
|
swFwThresholdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwFwThresholdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The table of individual thresholds."
|
|
::= { swFwSystem 3 }
|
|
|
|
swFwThresholdEntry OBJECT-TYPE
|
|
SYNTAX SwFwThresholdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry of an individual threshold."
|
|
INDEX { swFwClassAreaIndex, swFwThresholdIndex }
|
|
::= { swFwThresholdTable 1 }
|
|
|
|
SwFwThresholdEntry ::= SEQUENCE {
|
|
swFwThresholdIndex Integer32,
|
|
swFwStatus SwFwStatus,
|
|
swFwName DisplayString,
|
|
swFwLabel DisplayString,
|
|
swFwCurVal Integer32,
|
|
swFwLastEvent SwFwEvent,
|
|
swFwLastEventVal Integer32,
|
|
swFwLastEventTime DisplayString,
|
|
swFwLastState SwFwState,
|
|
swFwBehaviorType SwFwBehavior,
|
|
swFwBehaviorInt Integer32,
|
|
swFwLastSeverityLevel SwSevType
|
|
}
|
|
|
|
swFwThresholdIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the element index of
|
|
an threshold."
|
|
::= { swFwThresholdEntry 1 }
|
|
|
|
swFwStatus OBJECT-TYPE
|
|
SYNTAX SwFwStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This object identifies if an threshold is
|
|
enabled or disabled."
|
|
::= { swFwThresholdEntry 2 }
|
|
|
|
swFwName OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object is a name of the threshold."
|
|
::= { swFwThresholdEntry 3 }
|
|
|
|
swFwLabel OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(0..70))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object is a label of the threshold."
|
|
::= { swFwThresholdEntry 4 }
|
|
|
|
swFwCurVal OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object is a current counter of the threshold."
|
|
::= { swFwThresholdEntry 5 }
|
|
|
|
swFwLastEvent OBJECT-TYPE
|
|
SYNTAX SwFwEvent
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object is a last event type of the threshold."
|
|
::= { swFwThresholdEntry 6 }
|
|
|
|
swFwLastEventVal OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object is a last event value of the threshold."
|
|
::= { swFwThresholdEntry 7 }
|
|
|
|
swFwLastEventTime OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object is a last event time of the threshold."
|
|
::= { swFwThresholdEntry 8 }
|
|
|
|
swFwLastState OBJECT-TYPE
|
|
SYNTAX SwFwState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object is a last event state of the threshold."
|
|
::= { swFwThresholdEntry 9 }
|
|
|
|
swFwBehaviorType OBJECT-TYPE
|
|
SYNTAX SwFwBehavior
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "A behavior of which the thresholds generate event."
|
|
::= { swFwThresholdEntry 10 }
|
|
|
|
swFwBehaviorInt OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "A integer of which the thresholds generate continuous event."
|
|
::= { swFwThresholdEntry 11 }
|
|
|
|
swFwLastSeverityLevel OBJECT-TYPE
|
|
SYNTAX SwSevType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object is a last event severity level of the threshold."
|
|
::= { swFwThresholdEntry 12 }
|
|
|
|
-- swEndDevice Group
|
|
-- ###########################################################################
|
|
-- table for RLS of end devices.
|
|
-- swEndDevice consists of only one table.
|
|
-- swEndDeviceRlsTable contains entries of individual end devices' rls.
|
|
-- ###########################################################################
|
|
|
|
swEndDeviceRlsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwEndDeviceRlsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The table of individual end devices' rls."
|
|
::= { swEndDevice 1 }
|
|
|
|
swEndDeviceRlsEntry OBJECT-TYPE
|
|
SYNTAX SwEndDeviceRlsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry of an individual end devices' rls."
|
|
INDEX { swEndDevicePort, swEndDeviceAlpa }
|
|
::= { swEndDeviceRlsTable 1 }
|
|
|
|
SwEndDeviceRlsEntry ::= SEQUENCE {
|
|
swEndDevicePort Integer32,
|
|
swEndDeviceAlpa Integer32,
|
|
swEndDevicePortID OCTET STRING,
|
|
swEndDeviceLinkFailure Counter32,
|
|
swEndDeviceSyncLoss Counter32,
|
|
swEndDeviceSigLoss Counter32,
|
|
swEndDeviceProtoErr Counter32,
|
|
swEndDeviceInvalidWord Counter32,
|
|
swEndDeviceInvalidCRC Counter32
|
|
}
|
|
|
|
-- Since Silkworm family switches start with port # 0
|
|
-- snmp port # should be physical port # + 1.
|
|
-- i.e. snmp port # 3 translates to port # 2
|
|
swEndDevicePort OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the port of the end device."
|
|
::= { swEndDeviceRlsEntry 1 }
|
|
|
|
-- snmp alpa # should be logical alpa # + 1.
|
|
-- i.e. snmp alpa # 0xf0 translates to 0xef
|
|
swEndDeviceAlpa OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the alpa of the end device."
|
|
::= { swEndDeviceRlsEntry 2 }
|
|
|
|
swEndDevicePortID OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The object identifies the Fibre Channel port address
|
|
ID of the entry."
|
|
::= { swEndDeviceRlsEntry 3 }
|
|
|
|
swEndDeviceLinkFailure OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Link failure count for the end device."
|
|
::= { swEndDeviceRlsEntry 4 }
|
|
|
|
swEndDeviceSyncLoss OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Sync loss count for the end device."
|
|
::= { swEndDeviceRlsEntry 5 }
|
|
|
|
swEndDeviceSigLoss OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Sig loss count for the end device."
|
|
::= { swEndDeviceRlsEntry 6 }
|
|
|
|
swEndDeviceProtoErr OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Protocol err count for the end device."
|
|
::= { swEndDeviceRlsEntry 7 }
|
|
|
|
swEndDeviceInvalidWord OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Invalid word count for the end device."
|
|
::= { swEndDeviceRlsEntry 8 }
|
|
|
|
swEndDeviceInvalidCRC OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Invalid CRC count for the end device."
|
|
::= { swEndDeviceRlsEntry 9 }
|
|
|
|
-- table for displaying all the Groups
|
|
swGroupTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwGroupEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The table of groups. This may not be available
|
|
on all versions of Fabric OS."
|
|
::= { swGroup 1 }
|
|
|
|
swGroupEntry OBJECT-TYPE
|
|
SYNTAX SwGroupEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry of table of groups."
|
|
INDEX { swGroupIndex }
|
|
::= { swGroupTable 1 }
|
|
|
|
SwGroupEntry ::= SEQUENCE {
|
|
swGroupIndex Integer32,
|
|
swGroupName OCTET STRING,
|
|
swGroupType OCTET STRING
|
|
}
|
|
swGroupIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object is the group index starting from 1."
|
|
::= { swGroupEntry 1 }
|
|
|
|
swGroupName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the name of the group."
|
|
::= { swGroupEntry 2 }
|
|
|
|
swGroupType OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..15))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the type of the group."
|
|
::= { swGroupEntry 3 }
|
|
|
|
-- table for displaying group members for all the groups
|
|
|
|
swGroupMemTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwGroupMemEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The table of members of all groups. This may not
|
|
be available on all versions of Fabric OS."
|
|
::= { swGroup 2 }
|
|
|
|
swGroupMemEntry OBJECT-TYPE
|
|
SYNTAX SwGroupMemEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry for a member of a group."
|
|
INDEX { swGroupId, swGroupMemWwn }
|
|
::= { swGroupMemTable 1 }
|
|
|
|
SwGroupMemEntry ::= SEQUENCE {
|
|
swGroupId Integer32,
|
|
swGroupMemWwn FcWwn,
|
|
swGroupMemPos Integer32
|
|
}
|
|
|
|
swGroupId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the Group Id of the
|
|
member switch."
|
|
::= { swGroupMemEntry 1 }
|
|
|
|
swGroupMemWwn OBJECT-TYPE
|
|
SYNTAX FcWwn
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the WWN of the member switch."
|
|
::= { swGroupMemEntry 2 }
|
|
|
|
swGroupMemPos OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies position of the member
|
|
switch in the group. This is based on the order
|
|
that the switches were added in the group."
|
|
::= { swGroupMemEntry 3 }
|
|
|
|
-- ************************************************************************************
|
|
-- Bloom Performance counter tables. *
|
|
-- *
|
|
-- ************************************************************************************
|
|
|
|
swBlmPerfALPAMntTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwBlmPerfALPAMntEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "ALPA monitoring counter Table. "
|
|
::= { swBlmPerfMnt 1}
|
|
|
|
swBlmPerfALPAMntEntry OBJECT-TYPE
|
|
SYNTAX SwBlmPerfALPAMntEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION " ALPA monitoring counter for given ALPA."
|
|
INDEX { swBlmPerfAlpaPort,swBlmPerfAlpaIndx }
|
|
::= { swBlmPerfALPAMntTable 1}
|
|
|
|
SwBlmPerfALPAMntEntry ::= SEQUENCE {
|
|
swBlmPerfAlpaPort SwPortIndex,
|
|
swBlmPerfAlpaIndx Integer32,
|
|
swBlmPerfAlpa Integer32,
|
|
swBlmPerfAlpaCRCCnt OCTET STRING
|
|
}
|
|
|
|
swBlmPerfAlpaPort OBJECT-TYPE
|
|
SYNTAX SwPortIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " This Object identifies the port index of the switch."
|
|
::= { swBlmPerfALPAMntEntry 1}
|
|
|
|
swBlmPerfAlpaIndx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..126)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " This Object identifies the ALPA index. There can be 126 ALPA values"
|
|
::= { swBlmPerfALPAMntEntry 2}
|
|
|
|
swBlmPerfAlpa OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " This Object identifies the ALPA values. These values
|
|
range between x'01' and x'EF'(1 to 239). ALPA value x'00'
|
|
is reserved for FL_Port
|
|
If Alpa device is invalid, then it will have -1 value. "
|
|
::= { swBlmPerfALPAMntEntry 3}
|
|
|
|
swBlmPerfAlpaCRCCnt OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Get CRC count for given ALPA and port. This monitoring
|
|
provides information on the number of CRC errors
|
|
occurred on the frames destined to each possible ALPA
|
|
attached to a specific port."
|
|
|
|
::= { swBlmPerfALPAMntEntry 4}
|
|
|
|
swBlmPerfEEMntTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwBlmPerfEEMntEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION " End-to-End monitoring counter Table"
|
|
::= { swBlmPerfMnt 2}
|
|
|
|
swBlmPerfEEMntEntry OBJECT-TYPE
|
|
SYNTAX SwBlmPerfEEMntEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "End-to-End monitoring counter for given port."
|
|
INDEX { swBlmPerfEEPort, swBlmPerfEERefKey}
|
|
::= { swBlmPerfEEMntTable 1}
|
|
|
|
SwBlmPerfEEMntEntry ::= SEQUENCE{
|
|
swBlmPerfEEPort SwPortIndex,
|
|
swBlmPerfEERefKey Integer32,
|
|
swBlmPerfEECRC OCTET STRING,
|
|
swBlmPerfEEFCWRx OCTET STRING,
|
|
swBlmPerfEEFCWTx OCTET STRING,
|
|
swBlmPerfEESid Integer32,
|
|
swBlmPerfEEDid Integer32
|
|
}
|
|
|
|
swBlmPerfEEPort OBJECT-TYPE
|
|
SYNTAX SwPortIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " This object identifies the port number of the switch."
|
|
::= { swBlmPerfEEMntEntry 1}
|
|
|
|
swBlmPerfEERefKey OBJECT-TYPE
|
|
SYNTAX Integer32 (1..8)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the reference number
|
|
of the counter. This reference is number assigned
|
|
when a filter is created. In SNMP Index start one
|
|
instead of 0, add one to actual ref key"
|
|
::= { swBlmPerfEEMntEntry 2}
|
|
|
|
swBlmPerfEECRC OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Get End to End CRC error for the frames that matched
|
|
the SID-DID pair."
|
|
::= { swBlmPerfEEMntEntry 3}
|
|
|
|
|
|
swBlmPerfEEFCWRx OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Get End to End count of Fibre Channel words (FCW),
|
|
received by the port, that matched
|
|
the SID-DID pair. "
|
|
::= { swBlmPerfEEMntEntry 4 }
|
|
|
|
swBlmPerfEEFCWTx OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Get End to End count of Fibre Channel words (FCW),
|
|
transmitted by the port, that matched the SID-DID pair. "
|
|
::= { swBlmPerfEEMntEntry 5}
|
|
|
|
swBlmPerfEESid OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Gets SID info by reference number. SID (Source Identifier)
|
|
is a 3-byte field in the frame header used to indicate the
|
|
address identifier of the N-Port from which the frame was sent."
|
|
::= { swBlmPerfEEMntEntry 6 }
|
|
|
|
swBlmPerfEEDid OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Gets DID info by reference number.
|
|
DID (Destination Identifier) is a 3-byte field in the
|
|
frame header used to indicate the address identifier of
|
|
the N-Port to which the frame was sent."
|
|
::= { swBlmPerfEEMntEntry 7 }
|
|
|
|
swBlmPerfFltMntTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwBlmPerfFltMntEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Filter based monitoring counter."
|
|
::= { swBlmPerfMnt 3}
|
|
|
|
swBlmPerfFltMntEntry OBJECT-TYPE
|
|
SYNTAX SwBlmPerfFltMntEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION " Filter base monitoring counter for given port."
|
|
INDEX { swBlmPerfFltPort,swBlmPerfFltRefkey}
|
|
::= { swBlmPerfFltMntTable 1}
|
|
|
|
SwBlmPerfFltMntEntry ::= SEQUENCE{
|
|
swBlmPerfFltPort SwPortIndex,
|
|
swBlmPerfFltRefkey Integer32,
|
|
swBlmPerfFltCnt OCTET STRING,
|
|
swBlmPerfFltAlias DisplayString
|
|
}
|
|
|
|
swBlmPerfFltPort OBJECT-TYPE
|
|
SYNTAX SwPortIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the port number of the switch."
|
|
::= { swBlmPerfFltMntEntry 1}
|
|
|
|
swBlmPerfFltRefkey OBJECT-TYPE
|
|
SYNTAX Integer32 (1..8)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " This object identifies the reference number of the filter.
|
|
This reference number is assigned when a filter is created.
|
|
In SNMP Index start one instead of 0, add one to actual ref key"
|
|
::= { swBlmPerfFltMntEntry 2}
|
|
|
|
swBlmPerfFltCnt OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Get statistics of filter based monitor.
|
|
Filter based monitoring provides information
|
|
about a filter hit count such as
|
|
1. Read command
|
|
2. SCSI or IP traffic
|
|
3. SCSI Read/Write"
|
|
::= { swBlmPerfFltMntEntry 3 }
|
|
|
|
swBlmPerfFltAlias OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(0..20))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Alias name for the filter."
|
|
::= { swBlmPerfFltMntEntry 4}
|
|
|
|
swSwitchTrunkable OBJECT-TYPE
|
|
SYNTAX INTEGER { yes ( 8 ) , no ( 0 ) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The trunking status of the switch - whether the switch supports the trunking feature or not. The values are
|
|
yes(8) - the trunking feature is supported
|
|
no(0). - the trunking feature is not supported. "
|
|
|
|
::= { swTrunk 1}
|
|
|
|
swTrunkTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwTrunkEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION " Table to display trunking information for the switch. "
|
|
::= { swTrunk 2}
|
|
|
|
swTrunkEntry OBJECT-TYPE
|
|
SYNTAX SwTrunkEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Entry for the trunking table."
|
|
INDEX { swTrunkPortIndex }
|
|
::= { swTrunkTable 1}
|
|
|
|
SwTrunkEntry ::= SEQUENCE{
|
|
swTrunkPortIndex SwPortIndex,
|
|
swTrunkGroupNumber Integer32,
|
|
swTrunkMaster SwTrunkMaster,
|
|
swPortTrunked INTEGER
|
|
}
|
|
|
|
swTrunkPortIndex OBJECT-TYPE
|
|
SYNTAX SwPortIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the switch port index.
|
|
Note that the value of a port index is 1 higher than the
|
|
port number labeled on the front panel.
|
|
e.g. port index 1 correspond to port number 0. "
|
|
::= { swTrunkEntry 1 }
|
|
|
|
swTrunkGroupNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object is a logical entity which specifies
|
|
the Group Number to which the port belongs to.
|
|
If this value is Zero it means the port is not Trunked."
|
|
::= { swTrunkEntry 2}
|
|
|
|
swTrunkMaster OBJECT-TYPE
|
|
SYNTAX SwTrunkMaster
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Port number that is the trunk master of the group.
|
|
The trunk master implicitly defines the group.
|
|
All ports with the same master are considered to be part of the same group."
|
|
::= { swTrunkEntry 3 }
|
|
|
|
swPortTrunked OBJECT-TYPE
|
|
SYNTAX INTEGER {disabled(0), enabled(1)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The active trunk status for a member port.
|
|
Values are enabled(1) or disabled(0)."
|
|
::= { swTrunkEntry 4 }
|
|
|
|
|
|
swTrunkGrpTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwTrunkGrpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table to display trunking Performance
|
|
information for the switch."
|
|
::= { swTrunk 3}
|
|
|
|
swTrunkGrpEntry OBJECT-TYPE
|
|
SYNTAX SwTrunkGrpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Entry for the trunking Group table."
|
|
INDEX { swTrunkGrpNumber}
|
|
::= { swTrunkGrpTable 1}
|
|
|
|
SwTrunkGrpEntry ::= SEQUENCE{
|
|
swTrunkGrpNumber Integer32,
|
|
swTrunkGrpMaster SwTrunkMaster,
|
|
swTrunkGrpTx OCTET STRING,
|
|
swTrunkGrpRx OCTET STRING
|
|
}
|
|
|
|
swTrunkGrpNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object is a logical entity which
|
|
specifies the Group Number to which port
|
|
belongs to."
|
|
::= { swTrunkGrpEntry 1 }
|
|
|
|
swTrunkGrpMaster OBJECT-TYPE
|
|
SYNTAX SwTrunkMaster
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object gives the master port id
|
|
for the TrunkGroup."
|
|
::= { swTrunkGrpEntry 2 }
|
|
|
|
swTrunkGrpTx OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Gives the aggregate value of the
|
|
transmitted words from this TrunkGroup."
|
|
::= { swTrunkGrpEntry 3}
|
|
|
|
swTrunkGrpRx OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Gives the aggregate value of the
|
|
received words by this TrunkGroup."
|
|
::= { swTrunkGrpEntry 4 }
|
|
|
|
swTopTalkerMntMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
fabricmode (1),
|
|
fportmode (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Gives the mode in which toptalker
|
|
is installed"
|
|
::= { swTopTalker 1}
|
|
|
|
swTopTalkerMntNumEntries OBJECT-TYPE
|
|
SYNTAX Integer32 (1..32)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Gives the number of toptalking
|
|
flows"
|
|
::= { swTopTalker 2}
|
|
|
|
swTopTalkerMntTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwTopTalkerMntEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table to display toptalkingflows"
|
|
::= { swTopTalker 3}
|
|
|
|
swTopTalkerMntEntry OBJECT-TYPE
|
|
SYNTAX SwTopTalkerMntEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Entry for the toptalker table"
|
|
INDEX{ swTopTalkerMntIndex}
|
|
::= { swTopTalkerMntTable 1}
|
|
|
|
SwTopTalkerMntEntry ::= SEQUENCE{
|
|
swTopTalkerMntIndex Integer32,
|
|
swTopTalkerMntPort Integer32,
|
|
swTopTalkerMntSpid Integer32,
|
|
swTopTalkerMntDpid Integer32,
|
|
swTopTalkerMntflow Integer32,
|
|
swTopTalkerMntSwwn FcWwn,
|
|
swTopTalkerMntDwwn FcWwn
|
|
}
|
|
|
|
swTopTalkerMntIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..32)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the list/object
|
|
entry"
|
|
::= { swTopTalkerMntEntry 1}
|
|
|
|
|
|
swTopTalkerMntPort OBJECT-TYPE
|
|
SYNTAX Integer32 (1..32)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the switch port
|
|
number on which the f-port mode toptalker
|
|
is added."
|
|
::= { swTopTalkerMntEntry 2}
|
|
|
|
swTopTalkerMntSpid OBJECT-TYPE
|
|
SYNTAX Integer32 (1..32)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the SID of the host"
|
|
::= { swTopTalkerMntEntry 3}
|
|
|
|
swTopTalkerMntDpid OBJECT-TYPE
|
|
SYNTAX Integer32 (1..32)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the DID of the SID-DID pair"
|
|
::= { swTopTalkerMntEntry 4}
|
|
|
|
swTopTalkerMntflow OBJECT-TYPE
|
|
SYNTAX Integer32 (1..32)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the traffic flow in MB/sec"
|
|
::= { swTopTalkerMntEntry 5}
|
|
|
|
swTopTalkerMntSwwn OBJECT-TYPE
|
|
SYNTAX FcWwn
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the SID in WWN format of the host"
|
|
::= { swTopTalkerMntEntry 6}
|
|
|
|
swTopTalkerMntDwwn OBJECT-TYPE
|
|
SYNTAX FcWwn
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the DID in WWN format of the SID-DID pair"
|
|
::= { swTopTalkerMntEntry 7}
|
|
|
|
|
|
swCpuUsage OBJECT-TYPE
|
|
SYNTAX Integer32(0..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "System's cpu usage."
|
|
::= { swCpuOrMemoryUsage 1 }
|
|
|
|
swCpuNoOfRetries OBJECT-TYPE
|
|
SYNTAX Integer32 (1..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Number of times system should take cpu utilization sample before sending the CPU utilization trap."
|
|
::= { swCpuOrMemoryUsage 2 }
|
|
|
|
swCpuUsageLimit OBJECT-TYPE
|
|
SYNTAX Integer32 (1..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "CPU usage limit"
|
|
::= { swCpuOrMemoryUsage 3 }
|
|
|
|
swCpuPollingInterval OBJECT-TYPE
|
|
SYNTAX Integer32 (10..3600)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Time interval between two memory samples."
|
|
::= { swCpuOrMemoryUsage 4 }
|
|
|
|
swCpuAction OBJECT-TYPE
|
|
SYNTAX Integer32 (0..3)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Specifies the actions to be taken if system
|
|
resources exceed the specified threshold."
|
|
::= { swCpuOrMemoryUsage 5 }
|
|
|
|
swMemUsage OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "System's memory usage."
|
|
::= { swCpuOrMemoryUsage 6 }
|
|
|
|
swMemNoOfRetries OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Number of times system should take memory usage sample before sending the memory usage trap."
|
|
::= { swCpuOrMemoryUsage 7 }
|
|
|
|
swMemUsageLimit OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Memory usage limit"
|
|
::= { swCpuOrMemoryUsage 8 }
|
|
|
|
swMemPollingInterval OBJECT-TYPE
|
|
SYNTAX Integer32 (10..3600)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Time interval between two memory samples."
|
|
::= { swCpuOrMemoryUsage 9 }
|
|
|
|
swMemAction OBJECT-TYPE
|
|
SYNTAX Integer32 (0..3)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Specifies the actions to be taken if system
|
|
resources exceed the specified threshold."
|
|
::= { swCpuOrMemoryUsage 10 }
|
|
|
|
|
|
swMemUsageLimit1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Low memory usage limit"
|
|
::= { swCpuOrMemoryUsage 11 }
|
|
|
|
|
|
swMemUsageLimit3 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "High memory usage limit"
|
|
::= { swCpuOrMemoryUsage 12 }
|
|
|
|
|
|
swConnUnitPortStatEntry OBJECT-TYPE
|
|
SYNTAX SwConnUnitPortStatEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This represents the Conn unit Port Stats"
|
|
AUGMENTS {connUnitPortStatEntry}
|
|
::= { swConnUnitPortStatExtentionTable 1 }
|
|
|
|
SwConnUnitPortStatEntry ::= SEQUENCE {
|
|
swConnUnitCRCWithBadEOF OCTET STRING,
|
|
swConnUnitZeroTenancy OCTET STRING,
|
|
swConnUnitFLNumOfTenancy OCTET STRING,
|
|
swConnUnitNLNumOfTenancy OCTET STRING,
|
|
swConnUnitStopTenancyStarVation OCTET STRING,
|
|
swConnUnitOpend OCTET STRING,
|
|
swConnUnitTransferConnection OCTET STRING,
|
|
swConnUnitOpen OCTET STRING,
|
|
swConnUnitInvalidARB OCTET STRING,
|
|
swConnUnitFTB1Miss OCTET STRING,
|
|
swConnUnitFTB2Miss OCTET STRING,
|
|
swConnUnitFTB6Miss OCTET STRING,
|
|
swConnUnitZoneMiss OCTET STRING,
|
|
swConnUnitLunZoneMiss OCTET STRING,
|
|
swConnUnitBadEOF OCTET STRING,
|
|
swConnUnitLCRX OCTET STRING,
|
|
swConnUnitRDYPriority OCTET STRING,
|
|
swConnUnitLli OCTET STRING
|
|
}
|
|
swConnUnitCRCWithBadEOF OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of frames with CRC error with Bad EOF."
|
|
::= { swConnUnitPortStatEntry 1 }
|
|
|
|
swConnUnitZeroTenancy OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This counter is incremented when the FL_port acquires the loop but does not transmit a frame."
|
|
::= { swConnUnitPortStatEntry 2 }
|
|
swConnUnitFLNumOfTenancy OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This counter is incremented when the FL_port acquires the loop."
|
|
::= { swConnUnitPortStatEntry 3 }
|
|
|
|
swConnUnitNLNumOfTenancy OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This counter is incremented when the NL_port acquires the loop."
|
|
::= { swConnUnitPortStatEntry 4 }
|
|
|
|
swConnUnitStopTenancyStarVation OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This counter is incremented when the FL_port can not transmit a frame because of lack of credit."
|
|
::= { swConnUnitPortStatEntry 5 }
|
|
|
|
swConnUnitOpend OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of times FC port entered OPENED state."
|
|
::= { swConnUnitPortStatEntry 6 }
|
|
|
|
swConnUnitTransferConnection OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of times FC port entered TRANSFER state."
|
|
::= { swConnUnitPortStatEntry 7 }
|
|
|
|
swConnUnitOpen OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of times FC port entered OPEN state."
|
|
::= { swConnUnitPortStatEntry 8 }
|
|
|
|
swConnUnitInvalidARB OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of times FC port received invalid ARB."
|
|
::= { swConnUnitPortStatEntry 9 }
|
|
|
|
swConnUnitFTB1Miss OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This counter is incremented when the port receives a frame with a DID that can not be routed by FCR.. Applicable to 8G platforms only."
|
|
::= { swConnUnitPortStatEntry 10 }
|
|
|
|
swConnUnitFTB2Miss OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This counter is incremented when the port receives a frame with an SID/DID combination that can not be routed by the VF module.Applicable to 8G platforms only."
|
|
::= { swConnUnitPortStatEntry 11 }
|
|
|
|
swConnUnitFTB6Miss OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This counter is incremented when port receives a frame with an SID that can not be routed by FCR. Applicable to 8G platforms."
|
|
::= { swConnUnitPortStatEntry 12 }
|
|
|
|
swConnUnitZoneMiss OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This counter is incremented when the port receives a frame with an SID and DID that are not zoned together."
|
|
::= { swConnUnitPortStatEntry 13 }
|
|
|
|
swConnUnitLunZoneMiss OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This counter is incremented when the port receives a frame with an SID, DID and LUN that are not zoned together( This is not currently used )."
|
|
::= { swConnUnitPortStatEntry 14 }
|
|
|
|
swConnUnitBadEOF OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of frames with bad end-of-frame."
|
|
::= { swConnUnitPortStatEntry 15 }
|
|
|
|
swConnUnitLCRX OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of link control frames received."
|
|
::= { swConnUnitPortStatEntry 16 }
|
|
|
|
swConnUnitRDYPriority OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of times that sending R_RDY or VC_RDY primitive signals was a higher priority than sending frames, due to diminishing credit reserves in the transmitter at the other end of the fibre."
|
|
::= { swConnUnitPortStatEntry 17 }
|
|
|
|
swConnUnitLli OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number low level interrupts generated by the physical and link layer."
|
|
::= { swConnUnitPortStatEntry 18 }
|
|
--
|
|
-- Enterprise Specific Traps for Fibre Channel Switch (sw).
|
|
--
|
|
|
|
swTrapsV2 OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "The Traps for Brocade's Fibre Channel Switch."
|
|
::= { sw 0 }
|
|
|
|
swFault NOTIFICATION-TYPE
|
|
OBJECTS { swDiagResult, swSsn , swGroupName, swGroupType, swGroupMemPos
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION "Obsoleted this trap as firmware doesn't support this trap.
|
|
A swFault(1) is generated whenever the diagnostics
|
|
detects a fault with the switch."
|
|
--#TYPE "Switch is faulty."
|
|
--#SUMMARY "Faulty reason: %d and SSN is #%s,GroupName %s,GroupType %s,GroupMemPosition %d""
|
|
--#ARGUMENTS { 0, 1, 2, 3, 4}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 1
|
|
--#STATE NONOPERATIONAL
|
|
::= { swTrapsV2 1 }
|
|
|
|
swSensorScn NOTIFICATION-TYPE
|
|
OBJECTS { swSensorStatus, swSensorIndex, swSensorType,
|
|
swSensorValue, swSensorInfo, swSsn,
|
|
swGroupName, swGroupType, swGroupMemPos
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "A swSensorScn(2) is generated whenever an
|
|
environment sensor changes its operational state. For instance,
|
|
a fan stop working. The VarBind in the Trap Data Unit shall
|
|
contain the corresponding instance of the sensor
|
|
status, sensor index, sensor type, sensor value (reading)
|
|
and sensor information. Note that the sensor information contains the type of sensor
|
|
and its number in textual format."
|
|
--#TYPE "A sensor (temperature, fan, etc.) changed its operational state."
|
|
--#SUMMARY "%s: is currently in state %d and SSN is #%s"
|
|
--#ARGUMENTS { 4, 0, 5 }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#STATE OPERATIONAL
|
|
::= { swTrapsV2 2 }
|
|
|
|
swFCPortScn NOTIFICATION-TYPE
|
|
OBJECTS { swFCPortOpStatus, swFCPortIndex, swFCPortName,
|
|
swSsn, swFCPortFlag, swGroupName, swGroupType,
|
|
swGroupMemPos, swVfId }
|
|
STATUS current
|
|
DESCRIPTION "A swFCPortScn(3) is generated whenever an FC_Port
|
|
changes its operational state. For instance, the FC_Port
|
|
goes from on-line to offline. The VarBind in the Trap Data
|
|
Unit shall contain the corresponding instance of the
|
|
FC_Port's operational status, index, swFCPortName,swSsn and
|
|
swFCPortFlag. swSsn is optional varbind sent when swExtTrap
|
|
is also enabled.swVfId is optional if VF is enabled.
|
|
The three arguments swGroupName, swGroupType,
|
|
swGroupMemPos belong to swGroup table which is obsolete
|
|
and not implemented."
|
|
--#TYPE "A Fibre Channel Port changed its operational state."
|
|
--#SUMMARY "Port Index %d changed state to %d Port Name: %s and SSN is #%s"
|
|
--#ARGUMENTS { 1, 0, 2, 3 }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#STATE OPERATIONAL
|
|
::= { swTrapsV2 3 }
|
|
|
|
swEventTrap NOTIFICATION-TYPE
|
|
OBJECTS { swEventIndex, swEventTimeInfo, swEventLevel,
|
|
swEventRepeatCount, swEventDescr, swSsn,
|
|
swGroupName,swGroupType,swGroupMemPos,swVfId }
|
|
STATUS current
|
|
DESCRIPTION "This trap is generated when an event whose
|
|
level at or below swEventTrapLevel occurs."
|
|
--#TYPE "A firmware event has been logged"
|
|
--#SUMMARY "Event %d: %s (severity level %d) - %s SSN is #%s"
|
|
--#ARGUMENTS { 0, 1, 2, 4, 5 }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#STATE OPERATIONAL
|
|
::= { swTrapsV2 4 }
|
|
|
|
-- traps for Fabric Watch subsystem
|
|
|
|
swFabricWatchTrap NOTIFICATION-TYPE
|
|
OBJECTS { swFwClassAreaIndex,
|
|
swFwThresholdIndex,
|
|
swFwName,
|
|
swFwLabel,
|
|
swFwLastEventVal,
|
|
swFwLastEventTime,
|
|
swFwLastEvent,
|
|
swFwLastState,
|
|
swFwLastSeverityLevel,
|
|
swSsn,
|
|
swGroupName,
|
|
swGroupType,
|
|
swGroupMemPos,
|
|
swVfId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "trap to be sent by Fabric Watch to notify of an event"
|
|
--#TYPE "Fabric Watch has generated an event"
|
|
--#SUMMARY "Threshold %s in Class/Area %d at index %d has generated event %d with %d on %s. This event is %d. This event label is %d, event severity level is %d and SSN is #%s"
|
|
--#ARGUMENTS { 2, 0, 1, 6, 4, 5, 7, 3, 8, 9 }
|
|
--#SEVERITY WARNING
|
|
--#TIMEINDEX 1
|
|
--#STATE OPERATIONAL
|
|
::= { swTrapsV2 5 }
|
|
|
|
-- traps for track changes subsystem
|
|
|
|
swTrackChangesTrap NOTIFICATION-TYPE
|
|
OBJECTS { swTrackChangesInfo, swSsn,
|
|
swGroupName, swGroupType, swGroupMemPos,
|
|
swVfId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "trap to be sent for tracking login/logout/config changes"
|
|
--#TYPE "Track changes has generated a trap"
|
|
--#SUMMARY "%s and SSN is #%s"
|
|
--#ARGUMENTS { 0, 1 }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#STATE OPERATIONAL
|
|
::= { swTrapsV2 6 }
|
|
|
|
swIPv6ChangeTrap NOTIFICATION-TYPE
|
|
OBJECTS { swIPv6Address, swIPv6Status }
|
|
STATUS current
|
|
DESCRIPTION "This trap is generated when an ipv6 address
|
|
status change event occurs."
|
|
--#TYPE "IPv6 address status change has generated a trap"
|
|
--#SUMMARY
|
|
--#ARGUMENTS
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#STATE OPERATIONAL
|
|
::= { swTrapsV2 7 }
|
|
|
|
swPmgrEventTrap NOTIFICATION-TYPE
|
|
OBJECTS { swPmgrEventType, swPmgrEventTime, swPmgrEventDescr, swSsn, swVfId }
|
|
STATUS current
|
|
DESCRIPTION "This trap is generated when any partition manager
|
|
change happens."
|
|
--#TYPE "Partition manager status change has generated a trap"
|
|
--#SUMMARY "pmgr event of type %d occured on %d swVfId and SSN is #%s. Time is %s and the description is %s"
|
|
--#ARGUMENTS { 0, 4, 3, 1, 2 }
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#STATE OPERATIONAL
|
|
::= { swTrapsV2 8 }
|
|
|
|
swFabricReconfigTrap NOTIFICATION-TYPE
|
|
OBJECTS { swDomainID }
|
|
STATUS current
|
|
DESCRIPTION "trap to be sent for tracking fabric reconfiguration"
|
|
--#TYPE "Fabric reconfiguration has generated a trap"
|
|
--#SUMMARY
|
|
--#ARGUMENTS
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#STATE OPERATIONAL
|
|
::= { swTrapsV2 9 }
|
|
|
|
swFabricSegmentTrap NOTIFICATION-TYPE
|
|
OBJECTS { swFCPortIndex, swFCPortName, swSsn,
|
|
swFCPortFlag, swVfId }
|
|
STATUS current
|
|
DESCRIPTION "trap to be sent for tracking segmentation"
|
|
--#TYPE "Fabric segmentation has generated a trap"
|
|
--#SUMMARY
|
|
--#ARGUMENTS
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 1
|
|
--#STATE OPERATIONAL
|
|
::= { swTrapsV2 10 }
|
|
|
|
swExtTrap NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "THIS IS INTERNAL TRAP"
|
|
::= { swTrapsV2 11 }
|
|
|
|
-- end of Enterprise Specific Traps for Fibre Channel Switch (sw)
|
|