Fixes #7304: Require explicit values for all required choice fields during CSV import

This commit is contained in:
jeremystretch
2021-09-28 12:04:54 -04:00
parent 16f5e233d0
commit 71449b3414
9 changed files with 21 additions and 29 deletions

View File

@@ -70,7 +70,6 @@ class SiteGroupCSVForm(CustomFieldModelCSVForm):
class SiteCSVForm(CustomFieldModelCSVForm):
status = CSVChoiceField(
choices=SiteStatusChoices,
required=False,
help_text='Operational status'
)
region = CSVModelChoiceField(
@@ -156,7 +155,6 @@ class RackCSVForm(CustomFieldModelCSVForm):
)
status = CSVChoiceField(
choices=RackStatusChoices,
required=False,
help_text='Operational status'
)
role = CSVModelChoiceField(
@@ -929,22 +927,18 @@ class PowerFeedCSVForm(CustomFieldModelCSVForm):
)
status = CSVChoiceField(
choices=PowerFeedStatusChoices,
required=False,
help_text='Operational status'
)
type = CSVChoiceField(
choices=PowerFeedTypeChoices,
required=False,
help_text='Primary or redundant'
)
supply = CSVChoiceField(
choices=PowerFeedSupplyChoices,
required=False,
help_text='Supply type (AC/DC)'
)
phase = CSVChoiceField(
choices=PowerFeedPhaseChoices,
required=False,
help_text='Single or three-phase'
)

View File

@@ -322,10 +322,10 @@ class RackTestCase(ViewTestCases.PrimaryObjectViewTestCase):
}
cls.csv_data = (
"site,location,name,width,u_height",
"Site 1,,Rack 4,19,42",
"Site 1,Location 1,Rack 5,19,42",
"Site 2,Location 2,Rack 6,19,42",
"site,location,name,status,width,u_height",
"Site 1,,Rack 4,active,19,42",
"Site 1,Location 1,Rack 5,active,19,42",
"Site 2,Location 2,Rack 6,active,19,42",
)
cls.bulk_edit_data = {
@@ -1991,10 +1991,10 @@ class PowerFeedTestCase(ViewTestCases.PrimaryObjectViewTestCase):
}
cls.csv_data = (
"site,power_panel,name,voltage,amperage,max_utilization",
"Site 1,Power Panel 1,Power Feed 4,120,20,80",
"Site 1,Power Panel 1,Power Feed 5,120,20,80",
"Site 1,Power Panel 1,Power Feed 6,120,20,80",
"site,power_panel,name,status,type,supply,phase,voltage,amperage,max_utilization",
"Site 1,Power Panel 1,Power Feed 4,active,primary,ac,single-phase,120,20,80",
"Site 1,Power Panel 1,Power Feed 5,active,primary,ac,single-phase,120,20,80",
"Site 1,Power Panel 1,Power Feed 6,active,primary,ac,single-phase,120,20,80",
)
cls.bulk_edit_data = {