# Default Value Parameters ## DEFAULT_USER_PREFERENCES !!! tip "Dynamic Configuration Parameter" This is a dictionary defining the default preferences to be set for newly-created user accounts. For example, to set the default page size for all users to 100, define the following: ```python DEFAULT_USER_PREFERENCES = { "pagination": { "per_page": 100 } } ``` For a complete list of available preferences, log into NetBox and navigate to `/user/preferences/`. A period in a preference name indicates a level of nesting in the JSON data. The example above maps to `pagination.per_page`. --- ## PAGINATE_COUNT !!! tip "Dynamic Configuration Parameter" Default: 50 The default maximum number of objects to display per page within each list of objects. --- ## POWERFEED_DEFAULT_AMPERAGE !!! tip "Dynamic Configuration Parameter" Default: 15 The default value for the `amperage` field when creating new power feeds. --- ## POWERFEED_DEFAULT_MAX_UTILIZATION !!! tip "Dynamic Configuration Parameter" Default: 80 The default value (percentage) for the `max_utilization` field when creating new power feeds. --- ## POWERFEED_DEFAULT_VOLTAGE !!! tip "Dynamic Configuration Parameter" Default: 120 The default value for the `voltage` field when creating new power feeds. --- ## RACK_ELEVATION_DEFAULT_UNIT_HEIGHT !!! tip "Dynamic Configuration Parameter" Default: 22 Default height (in pixels) of a unit within a rack elevation. For best results, this should be approximately one tenth of `RACK_ELEVATION_DEFAULT_UNIT_WIDTH`. --- ## RACK_ELEVATION_DEFAULT_UNIT_WIDTH !!! tip "Dynamic Configuration Parameter" Default: 220 Default width (in pixels) of a unit within a rack elevation.