# Circuit Terminations
|
|
|
|
Each circuit may have up to two terminations, designated A and Z. At either termination, a circuit may connect to a site, device interface (via a cable), or to a provider network.
|
|
|
|
In adherence with NetBox's philosophy of closely modeling the real world, a circuit may be connected only to a physical interface. For example, circuits may not terminate to LAG interfaces, which are virtual in nature. In such cases, a separate physical circuit is associated with each LAG member interface and each needs to be modeled discretely.
|
|
|
|
!!! note
|
|
A circuit in NetBox represents a physical link, and cannot have more than two endpoints. When modeling a multi-point topology, each leg of the topology must be defined as a discrete circuit, with one end terminating within the provider's infrastructure. The provider network model is ideal for representing these networks.
|
|
|
|
## Fields
|
|
|
|
### Circuit
|
|
|
|
The [circuit](./circuit.md) to which this termination belongs.
|
|
|
|
### Termination Side
|
|
|
|
Designates the termination as forming either the A or Z end of the circuit.
|
|
|
|
### Mark Connected
|
|
|
|
If selected, the circuit termination will be considered "connected" even if no cable has been connected to it in NetBox.
|
|
|
|
### Site
|
|
|
|
The [site](../dcim/site.md) with which this circuit termination is associated. Once created, a cable can be connected between the circuit termination and a device interface (or similar component).
|
|
|
|
### Provider Network
|
|
|
|
Circuits which do not connect to a site modeled by NetBox can instead be terminated to a [provider network](./providernetwork.md) representing an unknown network operated by a [provider](./provider.md).
|
|
|
|
### Port Speed
|
|
|
|
The operating speed of the terminated interface, in kilobits per second. This is useful for documenting the speed of a circuit when the actual interface to which it terminates is not being modeled in NetBox.
|
|
|
|
### Upstream Speed
|
|
|
|
The upstream speed of the terminated interface (in kilobits per second), if different from the downstream speed (a common scenario with e.g. DOCSIS cable modems).
|
|
|
|
### Cross-connect ID
|
|
|
|
In a data center environment, circuits are often delivered via a local cross-connect. While it may not be appropriate to model the cross-connect itself in NetBox, it's a good idea to record its ID for reference where applicable.
|
|
|
|
### Patch Panel & Port(s)
|
|
|
|
Similar to the cross-connect ID, this field can be used to track physical connection details which may be outside the scope of what is being modeled in NetBox.
|