Update device_component_down_junos macro (#12898)

Detect state changes in sensors in both jnxFruState and jnxFruTable
This commit is contained in:
Thom Seddon
2021-06-09 08:47:59 +01:00
committed by GitHub
parent 4ee1abb1d4
commit 1066ee404a

View File

@@ -6,7 +6,7 @@
"component_normal": "(%component.status = 0 && %macros.component)",
"component_warning": "(%component.status = 1 && %macros.component)",
"device": "(%devices.disabled = 0 && %devices.ignore = 0)",
"device_component_down_junos": "%sensors.sensor_class = \"state\" && %sensors.sensor_current != \"6\" && %sensors.sensor_type = \"jnxFruState\" && %sensors.sensor_current != \"2\" && %sensors.sensor_alert = \"1\"",
"device_component_down_junos": "%sensors.sensor_class = \"state\" && %sensors.sensor_current != \"6\" && (%sensors.sensor_type = \"jnxFruState\" || %sensors.sensor_type = \"jnxFruTable\") && %sensors.sensor_current != \"2\" && %sensors.sensor_alert = \"1\"",
"device_component_down_cisco": "%sensors.sensor_current != \"1\" && %sensors.sensor_current != \"5\" && %sensors.sensor_type REGEXP \"^cisco.*State$\" && %sensors.sensor_alert = \"1\"",
"device_up": "(%devices.status = 1 && %macros.device)",
"device_down": "(%devices.status = 0 && %macros.device)",