@@ -1,121 +1,140 @@
|
||||
mib: PRIMEKEY-APPLIANCE-MIB
|
||||
modules:
|
||||
pre-cache:
|
||||
oids:
|
||||
- PRIMEKEY-APPLIANCE-MIB::pkSfp
|
||||
- PRIMEKEY-APPLIANCE-MIB::pkVhsm
|
||||
os:
|
||||
version: 'PRIMEKEY-APPLIANCE-MIB::pkAVersion'
|
||||
serial: 'PRIMEKEY-APPLIANCE-MIB::pkAHsmSerialNumber'
|
||||
# The Appliance S/N is not available via SNMP,
|
||||
# but we can retrieve the S/N for the Hardware Security Module.
|
||||
# but we can retrieve the S/N for the Hardware Security Module.
|
||||
sensors:
|
||||
count:
|
||||
options:
|
||||
skip_value_lt: 0
|
||||
data:
|
||||
-
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkASfpLoad1m
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkSfp
|
||||
value: PRIMEKEY-APPLIANCE-MIB::pkASfpLoad1m
|
||||
num_oid: '.1.3.6.1.4.1.22408.1.1.2.1.5.108.111.97.100.50.1{{ $index }}'
|
||||
descr: ' 1m CPU load'
|
||||
group: 'CPU'
|
||||
index: 1
|
||||
index: pkASfpLoad1m
|
||||
-
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkASfpLoad5m
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkSfp
|
||||
value: PRIMEKEY-APPLIANCE-MIB::pkASfpLoad5m
|
||||
num_oid: '.1.3.6.1.4.1.22408.1.1.2.1.5.108.111.97.100.51.1{{ $index }}'
|
||||
descr: ' 5m CPU load'
|
||||
group: 'CPU'
|
||||
index: 2
|
||||
index: pkASfpLoad5m
|
||||
-
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkASfpLoad15m
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkSfp
|
||||
value: PRIMEKEY-APPLIANCE-MIB::pkASfpLoad15m
|
||||
num_oid: '.1.3.6.1.4.1.22408.1.1.2.1.5.108.111.97.100.52.1{{ $index }}'
|
||||
descr: '15m CPU load'
|
||||
group: 'CPU'
|
||||
index: 3
|
||||
index: pkASfpLoad15m
|
||||
-
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkAClusterLocalNodeID
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkSfp
|
||||
value: PRIMEKEY-APPLIANCE-MIB::pkAClusterLocalNodeID
|
||||
num_oid: '.1.3.6.1.4.1.22408.1.1.2.1.8.99.108.117.115.116.101.114.49.1{{ $index }}'
|
||||
descr: 'Node ID'
|
||||
group: 'Database'
|
||||
index: 4
|
||||
index: pkAClusterLocalNodeID
|
||||
-
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkAClusterSize
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkSfp
|
||||
value: PRIMEKEY-APPLIANCE-MIB::pkAClusterSize
|
||||
num_oid: '.1.3.6.1.4.1.22408.1.1.2.1.8.99.108.117.115.116.101.114.50.1{{ $index }}'
|
||||
descr: 'Node Count'
|
||||
group: 'Database'
|
||||
index: 5
|
||||
index: pkAClusterSize
|
||||
-
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkAClusterActiveNodes
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkSfp
|
||||
value: PRIMEKEY-APPLIANCE-MIB::pkAClusterActiveNodes
|
||||
num_oid: '.1.3.6.1.4.1.22408.1.1.2.1.8.99.108.117.115.116.101.114.51.1{{ $index }}'
|
||||
descr: 'Nodes Active'
|
||||
group: 'Database'
|
||||
index: 6
|
||||
index: pkAClusterActiveNodes
|
||||
-
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkASfpRaidTotalDevices
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkSfp
|
||||
value: PRIMEKEY-APPLIANCE-MIB::pkASfpRaidTotalDevices
|
||||
num_oid: '.1.3.6.1.4.1.22408.1.1.2.1.5.114.97.105.100.52.1{{ $index }}'
|
||||
descr: 'RAID Devices'
|
||||
group: 'RAID'
|
||||
index: 7
|
||||
index: pkASfpRaidTotalDevices
|
||||
-
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkASfpRaidActiveDevices
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkSfp
|
||||
value: PRIMEKEY-APPLIANCE-MIB::pkASfpRaidActiveDevices
|
||||
num_oid: '.1.3.6.1.4.1.22408.1.1.2.1.5.114.97.105.100.54.1{{ $index }}'
|
||||
descr: 'RAID Active'
|
||||
group: 'RAID'
|
||||
index: 8
|
||||
index: pkASfpRaidActiveDevices
|
||||
fanspeed:
|
||||
options:
|
||||
skip_value_lt: 0
|
||||
data:
|
||||
-
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkASfpCpuFan
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkSfp
|
||||
value: PRIMEKEY-APPLIANCE-MIB::pkASfpCpuFan
|
||||
num_oid: '.1.3.6.1.4.1.22408.1.1.2.1.4.102.97.110.49.1{{ $index }}'
|
||||
descr: 'CPU Fan'
|
||||
group: 'CPU'
|
||||
index: 49
|
||||
index: pkASfpCpuFan
|
||||
-
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkASfpSysFan1
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkSfp
|
||||
value: PRIMEKEY-APPLIANCE-MIB::pkASfpSysFan1
|
||||
num_oid: '.1.3.6.1.4.1.22408.1.1.2.1.4.102.97.110.50.1{{ $index }}'
|
||||
descr: 'System Fan 1'
|
||||
group: 'System'
|
||||
index: 50
|
||||
index: pkASfpSysFan1
|
||||
-
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkASfpSysFan2
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkSfp
|
||||
value: PRIMEKEY-APPLIANCE-MIB::pkASfpSysFan2
|
||||
num_oid: '.1.3.6.1.4.1.22408.1.1.2.1.4.102.97.110.51.1{{ $index }}'
|
||||
descr: 'System Fan 2'
|
||||
group: 'System'
|
||||
index: 51
|
||||
index: pkASfpSysFan2
|
||||
-
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkASfpSysFan3
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkSfp
|
||||
value: PRIMEKEY-APPLIANCE-MIB::pkASfpSysFan3
|
||||
num_oid: '.1.3.6.1.4.1.22408.1.1.2.1.4.102.97.110.52.1{{ $index }}'
|
||||
descr: 'System Fan 3'
|
||||
group: 'System'
|
||||
index: 52
|
||||
index: pkASfpSysFan3
|
||||
percent:
|
||||
options:
|
||||
skip_value_lt: 0
|
||||
data:
|
||||
-
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkAVdbUsagePercent
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkSfp
|
||||
value: PRIMEKEY-APPLIANCE-MIB::pkAVdbUsagePercent
|
||||
num_oid: '.1.3.6.1.4.1.22408.1.1.2.1.4.118.100.98.49.1{{ $index }}'
|
||||
descr: 'DB Usage %'
|
||||
group: 'Database'
|
||||
index: 1
|
||||
index: pkAVdbUsagePercent
|
||||
warn_limit: 80
|
||||
high_limit: 100
|
||||
state:
|
||||
data:
|
||||
-
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkASfpVmStatus
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkSfp
|
||||
value: PRIMEKEY-APPLIANCE-MIB::pkASfpVmStatus
|
||||
num_oid: '.1.3.6.1.4.1.22408.1.1.2.1.2.118.109.1{{ $index }}'
|
||||
descr: 'Health VMs'
|
||||
group: 'Health of VMs'
|
||||
index: 1
|
||||
index: pkASfpVmStatus
|
||||
state_name: HealthVMs
|
||||
states:
|
||||
- { value: 0, generic: 0, graph: 0, descr: 'All OK' }
|
||||
- { value: 1, generic: 2, graph: 1, descr: 'Some Inactive' }
|
||||
-
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkAEJBCAHealth
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkSfp
|
||||
value: PRIMEKEY-APPLIANCE-MIB::pkAEJBCAHealth
|
||||
num_oid: '.1.3.6.1.4.1.22408.1.1.2.1.8.104.101.97.108.116.104.101.50.1{{ $index }}'
|
||||
descr: 'Health EJBCA'
|
||||
group: 'Health of VMs'
|
||||
index: 2
|
||||
index: pkAEJBCAHealth
|
||||
state_name: HealthEjbca
|
||||
states:
|
||||
- { value: 0, generic: 0, graph: 0, descr: 'All OK' }
|
||||
@@ -125,48 +144,52 @@ modules:
|
||||
num_oid: '.1.3.6.1.4.1.22408.1.1.2.1.8.104.101.97.108.116.104.115.50.1{{ $index }}'
|
||||
descr: 'Health SignServer'
|
||||
group: 'Health of VMs'
|
||||
index: 3
|
||||
state_name: HealthSignserver
|
||||
index: pkASignServerHealth
|
||||
snmp_flags: ['-OteQUS', '-Ci'] # Workaround to prevent walking off the end of the MiB
|
||||
state_name: HealthSignserver
|
||||
states:
|
||||
- { value: 0, generic: 0, graph: 0, descr: 'All OK' }
|
||||
- { value: 1, generic: 3, graph: 1, descr: 'Not Running or Unhealthy' }
|
||||
-
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkASfpCpuFanStatus
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkSfp
|
||||
value: PRIMEKEY-APPLIANCE-MIB::pkASfpCpuFanStatus
|
||||
num_oid: '.1.3.6.1.4.1.22408.1.1.2.1.4.102.97.110.53.1{{ $index }}'
|
||||
descr: 'Fan CPU'
|
||||
group: 'Fans'
|
||||
index: 4
|
||||
index: pkASfpCpuFanStatus
|
||||
state_name: FansCpu
|
||||
states:
|
||||
- { value: 0, generic: 0, graph: 0, descr: 'OK' }
|
||||
- { value: 1, generic: 2, graph: 1, descr: 'Fail' }
|
||||
-
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkASfpSysFansStatus
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkSfp
|
||||
value: PRIMEKEY-APPLIANCE-MIB::pkASfpSysFansStatus
|
||||
num_oid: '.1.3.6.1.4.1.22408.1.1.2.1.4.102.97.110.54.1'
|
||||
descr: 'Fans System'
|
||||
group: 'Fans'
|
||||
index: 5
|
||||
index: pkASfpSysFansStatus
|
||||
state_name: FansSystem
|
||||
states:
|
||||
- { value: 0, generic: 0, graph: 0, descr: 'All OK' }
|
||||
- { value: 1, generic: 1, graph: 1, descr: 'Fail' }
|
||||
-
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkAVdbStatus
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkSfp
|
||||
value: PRIMEKEY-APPLIANCE-MIB::pkAVdbStatus
|
||||
num_oid: '.1.3.6.1.4.1.22408.1.1.2.1.4.118.100.98.50.1{{ $index }}'
|
||||
descr: 'DB Storage'
|
||||
group: 'Database'
|
||||
index: 6
|
||||
index: pkAVdbStatus
|
||||
state_name: DbStorage
|
||||
states:
|
||||
- { value: 0, generic: 0, graph: 0, descr: '< 80% full' }
|
||||
- { value: 1, generic: 2, graph: 1, descr: '> 80% full' }
|
||||
-
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkAClusterLocalGaleraState
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkSfp
|
||||
value: PRIMEKEY-APPLIANCE-MIB::pkAClusterLocalGaleraState
|
||||
num_oid: '.1.3.6.1.4.1.22408.1.1.2.1.8.99.108.117.115.116.101.114.52.1{{ $index }}'
|
||||
descr: 'DB Enum'
|
||||
group: 'Database'
|
||||
index: 7
|
||||
index: pkAClusterLocalGaleraState
|
||||
state_name: DbEnum
|
||||
# Galera node status can be reported as a number or a comment:
|
||||
# - wsrep_local_state
|
||||
@@ -188,21 +211,23 @@ modules:
|
||||
- { value: 5, generic: 2, graph: 5, descr: 'Error' } # this and above is provider-specific error code
|
||||
- { value: 6, generic: 2, graph: 6, descr: 'Max' }
|
||||
-
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkASfpRaidStatus
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkSfp
|
||||
value: PRIMEKEY-APPLIANCE-MIB::pkASfpRaidStatus
|
||||
num_oid: '.1.3.6.1.4.1.22408.1.1.2.1.5.114.97.105.100.49.1{{ $index }}'
|
||||
descr: 'RAID Health'
|
||||
group: 'RAID'
|
||||
index: 8
|
||||
index: pkASfpRaidStatus
|
||||
state_name: RaidHealth
|
||||
states:
|
||||
- { value: 0, generic: 0, graph: 0, descr: 'Clean or Active' }
|
||||
- { value: 1, generic: 2, graph: 1, descr: 'Degraded' }
|
||||
-
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkAHsmStatusEnum
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkVhsm
|
||||
value: PRIMEKEY-APPLIANCE-MIB::pkAHsmStatusEnum
|
||||
num_oid: '.1.3.6.1.4.1.22408.1.1.2.2.4.104.115.109.50.1{{ $index }}'
|
||||
descr: 'HSM Enum'
|
||||
group: 'HSM'
|
||||
index: 9
|
||||
index: pkAHsmStatusEnum
|
||||
state_name: HsmEnum
|
||||
states:
|
||||
- { value: 0, generic: 0, graph: 0, descr: 'STATUS_is_OPER' }
|
||||
@@ -213,21 +238,23 @@ modules:
|
||||
- { value: 5, generic: 2, graph: 5, descr: 'STATUS_is_FAIL' }
|
||||
- { value: 5, generic: 3, graph: 6, descr: 'STATUS_is_OTHER' }
|
||||
-
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkAHsmStatusBool
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkVhsm
|
||||
value: PRIMEKEY-APPLIANCE-MIB::pkAHsmStatusBool
|
||||
num_oid: '.1.3.6.1.4.1.22408.1.1.2.2.4.104.115.109.51.1{{ $index }}'
|
||||
descr: 'HSM Healthy'
|
||||
group: 'HSM'
|
||||
index: 10
|
||||
index: pkAHsmStatusBool
|
||||
state_name: HsmHealthy
|
||||
states:
|
||||
- { value: 0, generic: 0, graph: 0, descr: 'OK' }
|
||||
- { value: 1, generic: 2, graph: 1, descr: 'Fail' }
|
||||
-
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkAHsmBatteryIntStatus
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkVhsm
|
||||
value: PRIMEKEY-APPLIANCE-MIB::pkAHsmBatteryIntStatus
|
||||
num_oid: '.1.3.6.1.4.1.22408.1.1.2.2.4.104.115.109.53.1{{ $index }}'
|
||||
descr: 'Battery Int'
|
||||
group: 'HSM'
|
||||
index: 11
|
||||
index: pkAHsmBatteryIntStatus
|
||||
state_name: BatteryInt
|
||||
states:
|
||||
- { value: 0, generic: 0, graph: 0, descr: 'OK' }
|
||||
@@ -237,35 +264,38 @@ modules:
|
||||
num_oid: '.1.3.6.1.4.1.22408.1.1.2.2.4.104.115.109.56.1{{ $index }}'
|
||||
descr: 'Battery Ext'
|
||||
group: 'HSM'
|
||||
index: 12
|
||||
state_name: BatteryExt
|
||||
index: pkAHsmBatteryExtStatus
|
||||
snmp_flags: ['-OteQUS', '-Ci'] # Workaround to prevent walking off the end of the MiB
|
||||
state_name: BatteryExt
|
||||
states:
|
||||
- { value: 0, generic: 0, graph: 0, descr: 'Ok or Absent' }
|
||||
- { value: 1, generic: 2, graph: 1, descr: 'Low or Fail' }
|
||||
temperature:
|
||||
data:
|
||||
-
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkASfpCpuTemp
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkSfp
|
||||
value: PRIMEKEY-APPLIANCE-MIB::pkASfpCpuTemp
|
||||
num_oid: '.1.3.6.1.4.1.22408.1.1.2.1.3.99.112.117.1{{ $index }}'
|
||||
descr: 'CPU Temp'
|
||||
group: 'CPU'
|
||||
index: 1
|
||||
index: pkASfpCpuTemp
|
||||
voltage:
|
||||
options:
|
||||
skip_value_lt: 0
|
||||
data:
|
||||
-
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkAHsmBatteryInt
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkVhsm
|
||||
value: PRIMEKEY-APPLIANCE-MIB::pkAHsmBatteryInt
|
||||
num_oid: '.1.3.6.1.4.1.22408.1.1.2.2.4.104.115.109.52.1{{ $index }}'
|
||||
descr: 'Int Battery'
|
||||
group: 'HSM'
|
||||
index: 52
|
||||
index: pkAHsmBatteryInt
|
||||
user_func: Number::cast
|
||||
-
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkAHsmBatteryExt
|
||||
oid: PRIMEKEY-APPLIANCE-MIB::pkVhsm
|
||||
value: PRIMEKEY-APPLIANCE-MIB::pkAHsmBatteryExt
|
||||
num_oid: '.1.3.6.1.4.1.22408.1.1.2.2.4.104.115.109.55.1{{ $index }}'
|
||||
descr: 'Ext Battery'
|
||||
group: 'HSM'
|
||||
index: 55
|
||||
index: pkAHsmBatteryExt
|
||||
user_func: Number::cast
|
||||
|
||||
@@ -4,7 +4,6 @@ type: appliance
|
||||
icon: primekey
|
||||
group: primekey
|
||||
mib_dir: primekey
|
||||
snmp_bulk: false
|
||||
over:
|
||||
- { graph: device_percent, text: "Database Usage" }
|
||||
- { graph: device_voltage, text: "HSM Voltage" }
|
||||
|
||||
@@ -27,62 +27,14 @@
|
||||
"sensor_deleted": 0,
|
||||
"sensor_class": "count",
|
||||
"poller_type": "snmp",
|
||||
"sensor_oid": ".1.3.6.1.4.1.22408.1.1.2.1.5.108.111.97.100.50.1",
|
||||
"sensor_index": "1",
|
||||
"sensor_oid": ".1.3.6.1.4.1.22408.1.1.2.1.8.99.108.117.115.116.101.114.51.1",
|
||||
"sensor_index": "pkAClusterActiveNodes",
|
||||
"sensor_type": "primekey",
|
||||
"sensor_descr": " 1m CPU load",
|
||||
"group": "CPU",
|
||||
"sensor_descr": "Nodes Active",
|
||||
"group": "Database",
|
||||
"sensor_divisor": 1,
|
||||
"sensor_multiplier": 1,
|
||||
"sensor_current": 0.36,
|
||||
"sensor_limit": null,
|
||||
"sensor_limit_warn": null,
|
||||
"sensor_limit_low": null,
|
||||
"sensor_limit_low_warn": null,
|
||||
"sensor_alert": 1,
|
||||
"sensor_custom": "No",
|
||||
"entPhysicalIndex": null,
|
||||
"entPhysicalIndex_measured": null,
|
||||
"sensor_prev": null,
|
||||
"user_func": null,
|
||||
"state_name": null
|
||||
},
|
||||
{
|
||||
"sensor_deleted": 0,
|
||||
"sensor_class": "count",
|
||||
"poller_type": "snmp",
|
||||
"sensor_oid": ".1.3.6.1.4.1.22408.1.1.2.1.5.108.111.97.100.51.1",
|
||||
"sensor_index": "2",
|
||||
"sensor_type": "primekey",
|
||||
"sensor_descr": " 5m CPU load",
|
||||
"group": "CPU",
|
||||
"sensor_divisor": 1,
|
||||
"sensor_multiplier": 1,
|
||||
"sensor_current": 0.34,
|
||||
"sensor_limit": null,
|
||||
"sensor_limit_warn": null,
|
||||
"sensor_limit_low": null,
|
||||
"sensor_limit_low_warn": null,
|
||||
"sensor_alert": 1,
|
||||
"sensor_custom": "No",
|
||||
"entPhysicalIndex": null,
|
||||
"entPhysicalIndex_measured": null,
|
||||
"sensor_prev": null,
|
||||
"user_func": null,
|
||||
"state_name": null
|
||||
},
|
||||
{
|
||||
"sensor_deleted": 0,
|
||||
"sensor_class": "count",
|
||||
"poller_type": "snmp",
|
||||
"sensor_oid": ".1.3.6.1.4.1.22408.1.1.2.1.5.108.111.97.100.52.1",
|
||||
"sensor_index": "3",
|
||||
"sensor_type": "primekey",
|
||||
"sensor_descr": "15m CPU load",
|
||||
"group": "CPU",
|
||||
"sensor_divisor": 1,
|
||||
"sensor_multiplier": 1,
|
||||
"sensor_current": 0.37,
|
||||
"sensor_current": 1,
|
||||
"sensor_limit": null,
|
||||
"sensor_limit_warn": null,
|
||||
"sensor_limit_low": null,
|
||||
@@ -100,7 +52,7 @@
|
||||
"sensor_class": "count",
|
||||
"poller_type": "snmp",
|
||||
"sensor_oid": ".1.3.6.1.4.1.22408.1.1.2.1.8.99.108.117.115.116.101.114.49.1",
|
||||
"sensor_index": "4",
|
||||
"sensor_index": "pkAClusterLocalNodeID",
|
||||
"sensor_type": "primekey",
|
||||
"sensor_descr": "Node ID",
|
||||
"group": "Database",
|
||||
@@ -124,7 +76,7 @@
|
||||
"sensor_class": "count",
|
||||
"poller_type": "snmp",
|
||||
"sensor_oid": ".1.3.6.1.4.1.22408.1.1.2.1.8.99.108.117.115.116.101.114.50.1",
|
||||
"sensor_index": "5",
|
||||
"sensor_index": "pkAClusterSize",
|
||||
"sensor_type": "primekey",
|
||||
"sensor_descr": "Node Count",
|
||||
"group": "Database",
|
||||
@@ -147,14 +99,14 @@
|
||||
"sensor_deleted": 0,
|
||||
"sensor_class": "count",
|
||||
"poller_type": "snmp",
|
||||
"sensor_oid": ".1.3.6.1.4.1.22408.1.1.2.1.8.99.108.117.115.116.101.114.51.1",
|
||||
"sensor_index": "6",
|
||||
"sensor_oid": ".1.3.6.1.4.1.22408.1.1.2.1.5.108.111.97.100.52.1",
|
||||
"sensor_index": "pkASfpLoad15m",
|
||||
"sensor_type": "primekey",
|
||||
"sensor_descr": "Nodes Active",
|
||||
"group": "Database",
|
||||
"sensor_descr": "15m CPU load",
|
||||
"group": "CPU",
|
||||
"sensor_divisor": 1,
|
||||
"sensor_multiplier": 1,
|
||||
"sensor_current": 1,
|
||||
"sensor_current": 0.37,
|
||||
"sensor_limit": null,
|
||||
"sensor_limit_warn": null,
|
||||
"sensor_limit_low": null,
|
||||
@@ -171,10 +123,58 @@
|
||||
"sensor_deleted": 0,
|
||||
"sensor_class": "count",
|
||||
"poller_type": "snmp",
|
||||
"sensor_oid": ".1.3.6.1.4.1.22408.1.1.2.1.5.114.97.105.100.52.1",
|
||||
"sensor_index": "7",
|
||||
"sensor_oid": ".1.3.6.1.4.1.22408.1.1.2.1.5.108.111.97.100.50.1",
|
||||
"sensor_index": "pkASfpLoad1m",
|
||||
"sensor_type": "primekey",
|
||||
"sensor_descr": "RAID Devices",
|
||||
"sensor_descr": " 1m CPU load",
|
||||
"group": "CPU",
|
||||
"sensor_divisor": 1,
|
||||
"sensor_multiplier": 1,
|
||||
"sensor_current": 0.36,
|
||||
"sensor_limit": null,
|
||||
"sensor_limit_warn": null,
|
||||
"sensor_limit_low": null,
|
||||
"sensor_limit_low_warn": null,
|
||||
"sensor_alert": 1,
|
||||
"sensor_custom": "No",
|
||||
"entPhysicalIndex": null,
|
||||
"entPhysicalIndex_measured": null,
|
||||
"sensor_prev": null,
|
||||
"user_func": null,
|
||||
"state_name": null
|
||||
},
|
||||
{
|
||||
"sensor_deleted": 0,
|
||||
"sensor_class": "count",
|
||||
"poller_type": "snmp",
|
||||
"sensor_oid": ".1.3.6.1.4.1.22408.1.1.2.1.5.108.111.97.100.51.1",
|
||||
"sensor_index": "pkASfpLoad5m",
|
||||
"sensor_type": "primekey",
|
||||
"sensor_descr": " 5m CPU load",
|
||||
"group": "CPU",
|
||||
"sensor_divisor": 1,
|
||||
"sensor_multiplier": 1,
|
||||
"sensor_current": 0.34,
|
||||
"sensor_limit": null,
|
||||
"sensor_limit_warn": null,
|
||||
"sensor_limit_low": null,
|
||||
"sensor_limit_low_warn": null,
|
||||
"sensor_alert": 1,
|
||||
"sensor_custom": "No",
|
||||
"entPhysicalIndex": null,
|
||||
"entPhysicalIndex_measured": null,
|
||||
"sensor_prev": null,
|
||||
"user_func": null,
|
||||
"state_name": null
|
||||
},
|
||||
{
|
||||
"sensor_deleted": 0,
|
||||
"sensor_class": "count",
|
||||
"poller_type": "snmp",
|
||||
"sensor_oid": ".1.3.6.1.4.1.22408.1.1.2.1.5.114.97.105.100.54.1",
|
||||
"sensor_index": "pkASfpRaidActiveDevices",
|
||||
"sensor_type": "primekey",
|
||||
"sensor_descr": "RAID Active",
|
||||
"group": "RAID",
|
||||
"sensor_divisor": 1,
|
||||
"sensor_multiplier": 1,
|
||||
@@ -195,10 +195,10 @@
|
||||
"sensor_deleted": 0,
|
||||
"sensor_class": "count",
|
||||
"poller_type": "snmp",
|
||||
"sensor_oid": ".1.3.6.1.4.1.22408.1.1.2.1.5.114.97.105.100.54.1",
|
||||
"sensor_index": "8",
|
||||
"sensor_oid": ".1.3.6.1.4.1.22408.1.1.2.1.5.114.97.105.100.52.1",
|
||||
"sensor_index": "pkASfpRaidTotalDevices",
|
||||
"sensor_type": "primekey",
|
||||
"sensor_descr": "RAID Active",
|
||||
"sensor_descr": "RAID Devices",
|
||||
"group": "RAID",
|
||||
"sensor_divisor": 1,
|
||||
"sensor_multiplier": 1,
|
||||
@@ -220,7 +220,7 @@
|
||||
"sensor_class": "fanspeed",
|
||||
"poller_type": "snmp",
|
||||
"sensor_oid": ".1.3.6.1.4.1.22408.1.1.2.1.4.102.97.110.49.1",
|
||||
"sensor_index": "49",
|
||||
"sensor_index": "pkASfpCpuFan",
|
||||
"sensor_type": "primekey",
|
||||
"sensor_descr": "CPU Fan",
|
||||
"group": "CPU",
|
||||
@@ -244,7 +244,7 @@
|
||||
"sensor_class": "fanspeed",
|
||||
"poller_type": "snmp",
|
||||
"sensor_oid": ".1.3.6.1.4.1.22408.1.1.2.1.4.102.97.110.50.1",
|
||||
"sensor_index": "50",
|
||||
"sensor_index": "pkASfpSysFan1",
|
||||
"sensor_type": "primekey",
|
||||
"sensor_descr": "System Fan 1",
|
||||
"group": "System",
|
||||
@@ -268,7 +268,7 @@
|
||||
"sensor_class": "fanspeed",
|
||||
"poller_type": "snmp",
|
||||
"sensor_oid": ".1.3.6.1.4.1.22408.1.1.2.1.4.102.97.110.51.1",
|
||||
"sensor_index": "51",
|
||||
"sensor_index": "pkASfpSysFan2",
|
||||
"sensor_type": "primekey",
|
||||
"sensor_descr": "System Fan 2",
|
||||
"group": "System",
|
||||
@@ -292,7 +292,7 @@
|
||||
"sensor_class": "fanspeed",
|
||||
"poller_type": "snmp",
|
||||
"sensor_oid": ".1.3.6.1.4.1.22408.1.1.2.1.4.102.97.110.52.1",
|
||||
"sensor_index": "52",
|
||||
"sensor_index": "pkASfpSysFan3",
|
||||
"sensor_type": "primekey",
|
||||
"sensor_descr": "System Fan 3",
|
||||
"group": "System",
|
||||
@@ -316,7 +316,7 @@
|
||||
"sensor_class": "percent",
|
||||
"poller_type": "snmp",
|
||||
"sensor_oid": ".1.3.6.1.4.1.22408.1.1.2.1.4.118.100.98.49.1",
|
||||
"sensor_index": "1",
|
||||
"sensor_index": "pkAVdbUsagePercent",
|
||||
"sensor_type": "primekey",
|
||||
"sensor_descr": "DB Usage %",
|
||||
"group": "Database",
|
||||
@@ -340,7 +340,7 @@
|
||||
"sensor_class": "state",
|
||||
"poller_type": "snmp",
|
||||
"sensor_oid": ".1.3.6.1.4.1.22408.1.1.2.2.4.104.115.109.56.1",
|
||||
"sensor_index": "12",
|
||||
"sensor_index": "pkAHsmBatteryExtStatus",
|
||||
"sensor_type": "BatteryExt",
|
||||
"sensor_descr": "Battery Ext",
|
||||
"group": "HSM",
|
||||
@@ -364,7 +364,7 @@
|
||||
"sensor_class": "state",
|
||||
"poller_type": "snmp",
|
||||
"sensor_oid": ".1.3.6.1.4.1.22408.1.1.2.2.4.104.115.109.53.1",
|
||||
"sensor_index": "11",
|
||||
"sensor_index": "pkAHsmBatteryIntStatus",
|
||||
"sensor_type": "BatteryInt",
|
||||
"sensor_descr": "Battery Int",
|
||||
"group": "HSM",
|
||||
@@ -388,7 +388,7 @@
|
||||
"sensor_class": "state",
|
||||
"poller_type": "snmp",
|
||||
"sensor_oid": ".1.3.6.1.4.1.22408.1.1.2.1.8.99.108.117.115.116.101.114.52.1",
|
||||
"sensor_index": "7",
|
||||
"sensor_index": "pkAClusterLocalGaleraState",
|
||||
"sensor_type": "DbEnum",
|
||||
"sensor_descr": "DB Enum",
|
||||
"group": "Database",
|
||||
@@ -412,7 +412,7 @@
|
||||
"sensor_class": "state",
|
||||
"poller_type": "snmp",
|
||||
"sensor_oid": ".1.3.6.1.4.1.22408.1.1.2.1.4.118.100.98.50.1",
|
||||
"sensor_index": "6",
|
||||
"sensor_index": "pkAVdbStatus",
|
||||
"sensor_type": "DbStorage",
|
||||
"sensor_descr": "DB Storage",
|
||||
"group": "Database",
|
||||
@@ -436,7 +436,7 @@
|
||||
"sensor_class": "state",
|
||||
"poller_type": "snmp",
|
||||
"sensor_oid": ".1.3.6.1.4.1.22408.1.1.2.1.4.102.97.110.53.1",
|
||||
"sensor_index": "4",
|
||||
"sensor_index": "pkASfpCpuFanStatus",
|
||||
"sensor_type": "FansCpu",
|
||||
"sensor_descr": "Fan CPU",
|
||||
"group": "Fans",
|
||||
@@ -460,7 +460,7 @@
|
||||
"sensor_class": "state",
|
||||
"poller_type": "snmp",
|
||||
"sensor_oid": ".1.3.6.1.4.1.22408.1.1.2.1.4.102.97.110.54.1",
|
||||
"sensor_index": "5",
|
||||
"sensor_index": "pkASfpSysFansStatus",
|
||||
"sensor_type": "FansSystem",
|
||||
"sensor_descr": "Fans System",
|
||||
"group": "Fans",
|
||||
@@ -484,7 +484,7 @@
|
||||
"sensor_class": "state",
|
||||
"poller_type": "snmp",
|
||||
"sensor_oid": ".1.3.6.1.4.1.22408.1.1.2.1.8.104.101.97.108.116.104.101.50.1",
|
||||
"sensor_index": "2",
|
||||
"sensor_index": "pkAEJBCAHealth",
|
||||
"sensor_type": "HealthEjbca",
|
||||
"sensor_descr": "Health EJBCA",
|
||||
"group": "Health of VMs",
|
||||
@@ -508,7 +508,7 @@
|
||||
"sensor_class": "state",
|
||||
"poller_type": "snmp",
|
||||
"sensor_oid": ".1.3.6.1.4.1.22408.1.1.2.1.8.104.101.97.108.116.104.115.50.1",
|
||||
"sensor_index": "3",
|
||||
"sensor_index": "pkASignServerHealth",
|
||||
"sensor_type": "HealthSignserver",
|
||||
"sensor_descr": "Health SignServer",
|
||||
"group": "Health of VMs",
|
||||
@@ -532,7 +532,7 @@
|
||||
"sensor_class": "state",
|
||||
"poller_type": "snmp",
|
||||
"sensor_oid": ".1.3.6.1.4.1.22408.1.1.2.1.2.118.109.1",
|
||||
"sensor_index": "1",
|
||||
"sensor_index": "pkASfpVmStatus",
|
||||
"sensor_type": "HealthVMs",
|
||||
"sensor_descr": "Health VMs",
|
||||
"group": "Health of VMs",
|
||||
@@ -556,7 +556,7 @@
|
||||
"sensor_class": "state",
|
||||
"poller_type": "snmp",
|
||||
"sensor_oid": ".1.3.6.1.4.1.22408.1.1.2.2.4.104.115.109.50.1",
|
||||
"sensor_index": "9",
|
||||
"sensor_index": "pkAHsmStatusEnum",
|
||||
"sensor_type": "HsmEnum",
|
||||
"sensor_descr": "HSM Enum",
|
||||
"group": "HSM",
|
||||
@@ -580,7 +580,7 @@
|
||||
"sensor_class": "state",
|
||||
"poller_type": "snmp",
|
||||
"sensor_oid": ".1.3.6.1.4.1.22408.1.1.2.2.4.104.115.109.51.1",
|
||||
"sensor_index": "10",
|
||||
"sensor_index": "pkAHsmStatusBool",
|
||||
"sensor_type": "HsmHealthy",
|
||||
"sensor_descr": "HSM Healthy",
|
||||
"group": "HSM",
|
||||
@@ -604,7 +604,7 @@
|
||||
"sensor_class": "state",
|
||||
"poller_type": "snmp",
|
||||
"sensor_oid": ".1.3.6.1.4.1.22408.1.1.2.1.5.114.97.105.100.49.1",
|
||||
"sensor_index": "8",
|
||||
"sensor_index": "pkASfpRaidStatus",
|
||||
"sensor_type": "RaidHealth",
|
||||
"sensor_descr": "RAID Health",
|
||||
"group": "RAID",
|
||||
@@ -628,7 +628,7 @@
|
||||
"sensor_class": "temperature",
|
||||
"poller_type": "snmp",
|
||||
"sensor_oid": ".1.3.6.1.4.1.22408.1.1.2.1.3.99.112.117.1",
|
||||
"sensor_index": "1",
|
||||
"sensor_index": "pkASfpCpuTemp",
|
||||
"sensor_type": "primekey",
|
||||
"sensor_descr": "CPU Temp",
|
||||
"group": "CPU",
|
||||
@@ -652,7 +652,7 @@
|
||||
"sensor_class": "voltage",
|
||||
"poller_type": "snmp",
|
||||
"sensor_oid": ".1.3.6.1.4.1.22408.1.1.2.2.4.104.115.109.52.1",
|
||||
"sensor_index": "52",
|
||||
"sensor_index": "pkAHsmBatteryInt",
|
||||
"sensor_type": "primekey",
|
||||
"sensor_descr": "Int Battery",
|
||||
"group": "HSM",
|
||||
|
||||
Reference in New Issue
Block a user