feature: Added more rules for the alert collection (#7430)

This commit is contained in:
FTBZ
2017-10-04 22:02:17 +02:00
committed by Neil Lathwood
parent d46df1770e
commit 2e849e1b02

View File

@@ -186,15 +186,15 @@
"rule": "%sensors.sensor_current ~ \"[3-4]\" && %sensors.sensor_oid = \".1.3.6.1.4.1.232.3.2.5.1.1.37.\"",
"name": "HPE iLo Server drive degraded/failure"
},
{
{
"rule": "%sensors.sensor_current ~ \"[3-4]\" && %sensors.sensor_oid = \".1.3.6.1.4.1.232.6.2.9.3.1.4.\"",
"name": "HPE iLo Server Power Supply degraded/failure"
},
{
{
"rule": "%sensors.sensor_current ~ \"[3-4]\" && %sensors.sensor_oid = \".1.3.6.1.4.1.232.6.2.6.7.1.9.\"",
"name": "HPE iLo Server Fan degraded/failure"
},
{
{
"rule": "%sensors.sensor_current ~ \"[3-4]\" && %sensors.sensor_oid = \".1.3.6.1.4.1.232.1.2.2.1.1.6.\"",
"name": "HPE iLo Server CPU degraded/failure"
},
@@ -202,8 +202,68 @@
"rule": "%sensors.sensor_current ~ \"[3-4]\" && %sensors.sensor_oid = \".1.3.6.1.4.1.232.6.2.14.13.1.20.\"",
"name": "HPE iLo Server Memory degraded/failure"
},
{
{
"rule": "%applications.app_type = \"os-updates\" && %applications.app_status >= \"10\"",
"name": "Applications OS-Updates, New Updates Available"
},
{
"rule": "%devices.os = \"hpblmos\" && %sensors.sensor_type = \"hpblmos_psustate\" && %sensors.sensor_current = \"[3-4]\"",
"name": "HPE BladeSystem has a bad power supply"
},
{
"rule": "%devices.os = \"hpblmos\" && %sensors.sensor_type = \"hpblmos_fanstate\" && %sensors.sensor_current = \"[3-4]\"",
"name": "HPE BladeSystem has a bad fan"
},
{
"rule": "%devices.os = \"axiscam\" && %sensors.sensor_type = \"tempSensorStatusState\" && %sensors.sensor_current = \"2\"",
"name": "AXIS camera has a failed temperature sensor"
},
{
"rule": "%devices.os = \"rittal-lcp\" && %sensors.sensor_type = \"cmcIIIUnitStatus\" && %sensors.sensor_current = \"2\"",
"name": "RITTAL LCP has a failed status"
},
{
"rule": "%devices.os = \"rittal-lcp\" && %sensors.sensor_type = \"cmcIIIUnitStatus\" && %sensors.sensor_current = \"3\"",
"name": "RITTAL LCP has an overloaded status"
},
{
"rule": "%devices.os = \"dsm\" && %sensors.sensor_type = \"systemStatusState\" && %sensors.sensor_current = \"2\"",
"name": "Synology NAS has a failed status"
},
{
"rule": "%devices.os = \"dsm\" && %sensors.sensor_type = \"powerStatusState\" && %sensors.sensor_current = \"2\"",
"name": "Synology NAS has a failed power status"
},
{
"rule": "%devices.os = \"dsm\" && %sensors.sensor_type = \"systemFanStatusState\" && %sensors.sensor_current = \"2\"",
"name": "Synology NAS has a failed fan status"
},
{
"rule": "%devices.os = \"dsm\" && %sensors.sensor_type = \"cpuFanStatusState\" && %sensors.sensor_current = \"2\"",
"name": "Synology NAS has a failed CPU fan status"
},
{
"rule": "%devices.os = \"dsm\" && %sensors.sensor_type = \"upgradeAvailableState\" && %sensors.sensor_current = \"1\"",
"name": "Synology NAS has a new upgrade available"
},
{
"rule": "%devices.os = \"dsm\" && %sensors.sensor_type = \"raidStatusState\" && %sensors.sensor_current = \"[11-12]\"",
"name": "Synology NAS has a bad RAID status"
},
{
"rule": "%devices.os = \"dsm\" && %sensors.sensor_type = \"diskStatusState\" && %sensors.sensor_current = \"[4-5]\"",
"name": "Synology NAS has a bad disk status"
},
{
"rule": "%devices.os = \"f5\" && %sensors.sensor_type = \"sysChassisPowerSupplyStatus\" && %sensors.sensor_current = \"0\"",
"name": "F5 appliance has a bad power supply"
},
{
"rule": "%devices.os = \"f5\" && %sensors.sensor_type = \"sysChassisFanStatus\" && %sensors.sensor_current = \"0\"",
"name": "F5 appliance has a bad fan"
},
{
"rule": "%devices.os = \"nxos\" && %sensors.sensor_type = \"cefcFanTrayOperStatus\" && %sensors.sensor_current = \"[3-4]\"",
"name": "Cisco NX-OS device has a bad fan"
}
]