mirror of
				https://github.com/librenms/librenms.git
				synced 2024-10-07 16:52:45 +00:00 
			
		
		
		
	move RADLAN mibs to mib root
git-svn-id: http://www.observium.org/svn/observer/trunk@1570 61d68cd4-352d-0410-923a-c4978735b2b8
This commit is contained in:
		
										
											
												File diff suppressed because it is too large
												Load Diff
											
										
									
								
							@@ -1,439 +0,0 @@
 | 
			
		||||
ENTITY-SENSOR-MIB DEFINITIONS ::= BEGIN
 | 
			
		||||
 | 
			
		||||
-- draft-ietf-entmib-sensor-mib-02.txt
 | 
			
		||||
 | 
			
		||||
IMPORTS
 | 
			
		||||
        rlEnv   FROM RADLAN-MIB
 | 
			
		||||
        MODULE-IDENTITY, OBJECT-TYPE,
 | 
			
		||||
        Integer32, Unsigned32, mib-2
 | 
			
		||||
                FROM SNMPv2-SMI
 | 
			
		||||
        MODULE-COMPLIANCE, OBJECT-GROUP
 | 
			
		||||
                FROM SNMPv2-CONF
 | 
			
		||||
        TEXTUAL-CONVENTION, TimeStamp
 | 
			
		||||
                FROM SNMPv2-TC
 | 
			
		||||
        entPhysicalIndex, entityPhysicalGroup
 | 
			
		||||
                FROM ENTITY-MIB
 | 
			
		||||
        SnmpAdminString
 | 
			
		||||
                FROM SNMP-FRAMEWORK-MIB;
 | 
			
		||||
 | 
			
		||||
entitySensorMIB MODULE-IDENTITY
 | 
			
		||||
    LAST-UPDATED    "200210160000Z"
 | 
			
		||||
    ORGANIZATION    "IETF Entity MIB Working Group"
 | 
			
		||||
    CONTACT-INFO
 | 
			
		||||
            "        Andy Bierman
 | 
			
		||||
                     Cisco Systems, Inc.
 | 
			
		||||
                Tel: +1 408-527-3711
 | 
			
		||||
             E-mail: abierman@cisco.com
 | 
			
		||||
             Postal: 170 West Tasman Drive
 | 
			
		||||
                     San Jose, CA USA 95134
 | 
			
		||||
 | 
			
		||||
                     Dan Romascanu
 | 
			
		||||
                     Avaya Communication
 | 
			
		||||
                Tel: +972-3-645-8414
 | 
			
		||||
              Email: dromasca@avaya.com
 | 
			
		||||
             Postal: Atidim technology Park, Bldg. #3
 | 
			
		||||
                     Tel Aviv, Israel, 61131
 | 
			
		||||
 | 
			
		||||
                     K.C. Norseth
 | 
			
		||||
                     L-3 Communications
 | 
			
		||||
                Tel: +1 801-594-2809
 | 
			
		||||
              Email: kenyon.c.norseth@L-3com.com
 | 
			
		||||
             Postal: 640 N. 2200 West.
 | 
			
		||||
                     Salt Lake City, Utah 84116-0850
 | 
			
		||||
 | 
			
		||||
             Send comments to <entmib@ietf.org>
 | 
			
		||||
             Mailing list subscription info:
 | 
			
		||||
               http://www.ietf.org/mailman/listinfo/entmib "
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "This module defines Entity MIB extensions for physical
 | 
			
		||||
            sensors."
 | 
			
		||||
    REVISION        "200210160000Z"
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "Initial version of the Entity Sensor MIB module, published
 | 
			
		||||
            as RFC xxxx." -- RFC Editor assigns xxxx
 | 
			
		||||
--  ::= { mib-2 xxx } ## IANA needs to assign xxx
 | 
			
		||||
    ::= { rlEnv 2 }
 | 
			
		||||
 | 
			
		||||
entitySensorObjects              OBJECT IDENTIFIER
 | 
			
		||||
     ::= { entitySensorMIB 1 }
 | 
			
		||||
-- entitySensorNotifications        OBJECT IDENTIFIER
 | 
			
		||||
--     ::= { entitySensorMIB 2 }
 | 
			
		||||
entitySensorConformance          OBJECT IDENTIFIER
 | 
			
		||||
     ::= { entitySensorMIB 3 }
 | 
			
		||||
 | 
			
		||||
--
 | 
			
		||||
-- Textual Conventions
 | 
			
		||||
--
 | 
			
		||||
 | 
			
		||||
EntitySensorDataType ::= TEXTUAL-CONVENTION
 | 
			
		||||
    STATUS       current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "An object using this data type represents the Entity Sensor
 | 
			
		||||
            measurement data type associated with a physical sensor
 | 
			
		||||
            value. The actual data units are determined by examining an
 | 
			
		||||
            object of this type together with the associated
 | 
			
		||||
            EntitySensorDataScale object.
 | 
			
		||||
 | 
			
		||||
            An object of this type SHOULD be defined together with
 | 
			
		||||
            objects of type EntitySensorDataScale and
 | 
			
		||||
            EntitySensorPrecision.  Together, associated objects of
 | 
			
		||||
            these three types are used to identify the semantics of an
 | 
			
		||||
            object of type EntitySensorValue.
 | 
			
		||||
 | 
			
		||||
            Valid values are:
 | 
			
		||||
 | 
			
		||||
               other(1):        a measure other than those listed below
 | 
			
		||||
               unknown(2):      unknown measurement, or arbitrary,
 | 
			
		||||
                                relative numbers
 | 
			
		||||
               voltsAC(3):      electric potential
 | 
			
		||||
               voltsDC(4):      electric potential
 | 
			
		||||
               amperes(5):      electric current
 | 
			
		||||
               watts(6):        power
 | 
			
		||||
               hertz(7):        frequency
 | 
			
		||||
               celsius(8):      temperature
 | 
			
		||||
               percentRH(9):    percent relative humidity
 | 
			
		||||
               rpm(10):         shaft revolutions per minute
 | 
			
		||||
               cmm(11),:        cubic meters per minute (airflow)
 | 
			
		||||
               truthvalue(12):  value takes { true(1), false(2) }
 | 
			
		||||
 | 
			
		||||
            "
 | 
			
		||||
    SYNTAX INTEGER {
 | 
			
		||||
        other(1),
 | 
			
		||||
        unknown(2),
 | 
			
		||||
        voltsAC(3),
 | 
			
		||||
        voltsDC(4),
 | 
			
		||||
        amperes(5),
 | 
			
		||||
        watts(6),
 | 
			
		||||
        hertz(7),
 | 
			
		||||
        celsius(8),
 | 
			
		||||
        percentRH(9),
 | 
			
		||||
        rpm(10),
 | 
			
		||||
        cmm(11),
 | 
			
		||||
        truthvalue(12)
 | 
			
		||||
    }
 | 
			
		||||
 | 
			
		||||
EntitySensorDataScale ::= TEXTUAL-CONVENTION
 | 
			
		||||
    STATUS       current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "An object using this data type represents a data scaling
 | 
			
		||||
            factor, represented with an International System of Units
 | 
			
		||||
            (SI) prefix.  The actual data units are determined by
 | 
			
		||||
            examining an object of this type together with the
 | 
			
		||||
            associated EntitySensorDataType object.
 | 
			
		||||
 | 
			
		||||
            An object of this type SHOULD be defined together with
 | 
			
		||||
            objects of type EntitySensorDataType and
 | 
			
		||||
            EntitySensorPrecision.  Together, associated objects of
 | 
			
		||||
            these three types are used to identify the semantics of an
 | 
			
		||||
            object of type EntitySensorValue."
 | 
			
		||||
    REFERENCE
 | 
			
		||||
            "TBD"
 | 
			
		||||
    SYNTAX INTEGER {
 | 
			
		||||
        yocto(1),   -- 10^-24
 | 
			
		||||
        zepto(2),   -- 10^-21
 | 
			
		||||
        atto(3),    -- 10^-18
 | 
			
		||||
        femto(4),   -- 10^-15
 | 
			
		||||
        pico(5),    -- 10^-12
 | 
			
		||||
        nano(6),    -- 10^-9
 | 
			
		||||
        micro(7),   -- 10^-6
 | 
			
		||||
        milli(8),   -- 10^-3
 | 
			
		||||
        units(9),   -- 10^0
 | 
			
		||||
        kilo(10),   -- 10^3
 | 
			
		||||
        mega(11),   -- 10^6
 | 
			
		||||
        giga(12),   -- 10^9
 | 
			
		||||
        tera(13),   -- 10^12
 | 
			
		||||
        exa(14),    -- 10^15
 | 
			
		||||
        peta(15),   -- 10^18
 | 
			
		||||
        zetta(16),  -- 10^21
 | 
			
		||||
        yotta(17)   -- 10^24
 | 
			
		||||
    }
 | 
			
		||||
 | 
			
		||||
EntitySensorPrecision ::= TEXTUAL-CONVENTION
 | 
			
		||||
    STATUS       current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "An object using this data type represents a sensor
 | 
			
		||||
            precision range.
 | 
			
		||||
 | 
			
		||||
            An object of this type SHOULD be defined together with
 | 
			
		||||
            objects of type EntitySensorDataType and
 | 
			
		||||
            EntitySensorDataScale.  Together, associated objects of
 | 
			
		||||
            these three types are used to identify the semantics of an
 | 
			
		||||
            object of type EntitySensorValue.
 | 
			
		||||
 | 
			
		||||
            If an object of this type contains a value in the range 1 to
 | 
			
		||||
            9, it represents the number of decimal places in the
 | 
			
		||||
            fractional part of an associated EntitySensorValue fixed-
 | 
			
		||||
            point number.
 | 
			
		||||
 | 
			
		||||
            If an object of this type contains a value in the range -8
 | 
			
		||||
            to -1, it represents the number of accurate digits in the
 | 
			
		||||
            associated EntitySensorValue fixed-point number.
 | 
			
		||||
 | 
			
		||||
            The value zero indicates the associated EntitySensorValue
 | 
			
		||||
            object is not a fixed-point number.
 | 
			
		||||
 | 
			
		||||
            Agent implementors must choose a value for the associated
 | 
			
		||||
            EntitySensorPrecision object so that the precision and
 | 
			
		||||
            accuracy of the associated EntitySensorValue object is
 | 
			
		||||
            correctly indicated.
 | 
			
		||||
 | 
			
		||||
            For example, a physical entity representing a temperature
 | 
			
		||||
            sensor that can measure 0 degrees to 100 degrees C in 0.1
 | 
			
		||||
            degree increments, +/- 0.05 degrees, would have an
 | 
			
		||||
            EntitySensorPrecision value of '1', an EntitySensorDataScale
 | 
			
		||||
            value of 'units(9)', and an EntitySensorValue ranging from
 | 
			
		||||
            '0' to '1000'.  The EntitySensorValue would be interpreted
 | 
			
		||||
            as 'degrees C * 10'."
 | 
			
		||||
    SYNTAX Integer32 (-8..9)
 | 
			
		||||
 | 
			
		||||
EntitySensorValue ::= TEXTUAL-CONVENTION
 | 
			
		||||
    STATUS       current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "An object using this data type represents an Entity Sensor
 | 
			
		||||
            value.
 | 
			
		||||
            An object of this type SHOULD be defined together with
 | 
			
		||||
            objects of type EntitySensorDataType, EntitySensorDataScale
 | 
			
		||||
            and EntitySensorPrecision.  Together, associated objects of
 | 
			
		||||
            those three types are used to identify the semantics of an
 | 
			
		||||
            object of this data type.
 | 
			
		||||
 | 
			
		||||
            The semantics of an object using this data type are
 | 
			
		||||
            determined by the value of the associated
 | 
			
		||||
            EntitySensorDataType object.
 | 
			
		||||
 | 
			
		||||
            If the associated EntitySensorDataType object is equal to
 | 
			
		||||
            'voltsAC(3)', 'voltsDC(4)', 'amperes(5)', 'watts(6),
 | 
			
		||||
            'hertz(7)', 'celsius(8)', or 'cmm(11)', then an object of
 | 
			
		||||
            this type MUST contain a fixed point number ranging from
 | 
			
		||||
            -999,999,999 to +999,999,999.  The value -1000000000
 | 
			
		||||
            indicates an underflow error. The value +1000000000
 | 
			
		||||
            indicates an overflow error.  The EntitySensorPrecision
 | 
			
		||||
            indicates how many fractional digits are represented in the
 | 
			
		||||
            associated EntitySensorValue object.
 | 
			
		||||
 | 
			
		||||
            If the associated EntitySensorDataType object is equal to
 | 
			
		||||
            'percentRH(9)', then an object of this type MUST contain a
 | 
			
		||||
            number ranging from 0 to 100.
 | 
			
		||||
 | 
			
		||||
            If the associated EntitySensorDataType object is equal to
 | 
			
		||||
            'rpm(10)', then an object of this type MUST contain a number
 | 
			
		||||
            ranging from -999,999,999 to +999,999,999.
 | 
			
		||||
 | 
			
		||||
            If the associated EntitySensorDataType object is equal to
 | 
			
		||||
            'truthvalue(12)', then an object of this type MUST contain
 | 
			
		||||
            either the value 'true(1)' or the value 'false(2)'.
 | 
			
		||||
 | 
			
		||||
            If the associated EntitySensorDataType object is equal to
 | 
			
		||||
            'other(1)' or unknown(2)', then an object of this type MUST
 | 
			
		||||
            contain a number ranging from -1000000000 to 1000000000."
 | 
			
		||||
    SYNTAX Integer32 (-1000000000..1000000000)
 | 
			
		||||
 | 
			
		||||
EntitySensorStatus ::= TEXTUAL-CONVENTION
 | 
			
		||||
    STATUS       current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "An object using this data type represents the operational
 | 
			
		||||
            status of a physical sensor.
 | 
			
		||||
 | 
			
		||||
            The value 'ok(1)' indicates that the agent can obtain the
 | 
			
		||||
            sensor value.
 | 
			
		||||
 | 
			
		||||
            The value 'unavailable(2)' indicates that the agent
 | 
			
		||||
            presently cannot obtain the sensor value.
 | 
			
		||||
 | 
			
		||||
            The value 'nonoperational(3)' indicates that the agent
 | 
			
		||||
            believes the sensor is broken.  The sensor could have a hard
 | 
			
		||||
            failure (disconnected wire), or a soft failure such as out-
 | 
			
		||||
            of-range, jittery, or wildly fluctuating readings."
 | 
			
		||||
    SYNTAX INTEGER {
 | 
			
		||||
        ok(1),
 | 
			
		||||
        unavailable(2),
 | 
			
		||||
        nonoperational(3)
 | 
			
		||||
    }
 | 
			
		||||
 | 
			
		||||
--
 | 
			
		||||
-- Entity Sensor Table
 | 
			
		||||
--
 | 
			
		||||
 | 
			
		||||
entPhySensorTable OBJECT-TYPE
 | 
			
		||||
    SYNTAX        SEQUENCE OF EntPhySensorEntry
 | 
			
		||||
    MAX-ACCESS    not-accessible
 | 
			
		||||
    STATUS        current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "This table contains one row per physical sensor represented
 | 
			
		||||
            by an associated row in the entPhysicalTable."
 | 
			
		||||
    ::= { entitySensorObjects 1 }
 | 
			
		||||
 | 
			
		||||
entPhySensorEntry OBJECT-TYPE
 | 
			
		||||
    SYNTAX        EntPhySensorEntry
 | 
			
		||||
    MAX-ACCESS    not-accessible
 | 
			
		||||
    STATUS        current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "Information about a particular physical sensor.
 | 
			
		||||
 | 
			
		||||
            An entry in this table describes the present reading of a
 | 
			
		||||
            sensor, the measurement units and scale, and sensor
 | 
			
		||||
            operational status.
 | 
			
		||||
 | 
			
		||||
            Entries are created in this table by the agent.  An entry
 | 
			
		||||
            for each physical sensor SHOULD be created at the same time
 | 
			
		||||
            as the associated entPhysicalEntry.  An entry SHOULD be
 | 
			
		||||
            destroyed if the associated entPhysicalEntry is destroyed."
 | 
			
		||||
    INDEX  { entPhysicalIndex }    -- SPARSE-AUGMENTS
 | 
			
		||||
    ::= { entPhySensorTable 1 }
 | 
			
		||||
 | 
			
		||||
EntPhySensorEntry ::= SEQUENCE {
 | 
			
		||||
        entPhySensorType            EntitySensorDataType,
 | 
			
		||||
        entPhySensorScale           EntitySensorDataScale,
 | 
			
		||||
        entPhySensorPrecision       EntitySensorPrecision,
 | 
			
		||||
        entPhySensorValue           EntitySensorValue,
 | 
			
		||||
        entPhySensorOperStatus      EntitySensorStatus,
 | 
			
		||||
        entPhySensorUnitsDisplay    SnmpAdminString,
 | 
			
		||||
        entPhySensorValueTimeStamp  TimeStamp,
 | 
			
		||||
        entPhySensorValueUpdateRate Unsigned32
 | 
			
		||||
}
 | 
			
		||||
 | 
			
		||||
entPhySensorType OBJECT-TYPE
 | 
			
		||||
    SYNTAX        EntitySensorDataType
 | 
			
		||||
    MAX-ACCESS    read-only
 | 
			
		||||
    STATUS        current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "The type of data returned by the associated
 | 
			
		||||
            entPhySensorValue object.
 | 
			
		||||
 | 
			
		||||
            This object SHOULD be set by the agent during entry
 | 
			
		||||
            creation, and the value SHOULD NOT change during operation."
 | 
			
		||||
    ::= { entPhySensorEntry 1 }
 | 
			
		||||
 | 
			
		||||
entPhySensorScale OBJECT-TYPE
 | 
			
		||||
    SYNTAX        EntitySensorDataScale
 | 
			
		||||
    MAX-ACCESS    read-only
 | 
			
		||||
    STATUS        current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "The exponent to apply to values returned by the associated
 | 
			
		||||
            entPhySensorValue object.
 | 
			
		||||
 | 
			
		||||
            This object SHOULD be set by the agent during entry
 | 
			
		||||
            creation, and the value SHOULD NOT change during operation."
 | 
			
		||||
    ::= { entPhySensorEntry 2 }
 | 
			
		||||
 | 
			
		||||
entPhySensorPrecision OBJECT-TYPE
 | 
			
		||||
    SYNTAX        EntitySensorPrecision
 | 
			
		||||
    MAX-ACCESS    read-only
 | 
			
		||||
    STATUS        current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "The number of decimal places of precision in fixed-point
 | 
			
		||||
            sensor values returned by the associated entPhySensorValue
 | 
			
		||||
            object.
 | 
			
		||||
 | 
			
		||||
            This object SHOULD be set to '0' when the associated
 | 
			
		||||
            entPhySensorType value is not a fixed-point type: e.g.,
 | 
			
		||||
            'percentRH(9)', 'rpm(10)', 'cmm(11)', or 'truthvalue(12)'.
 | 
			
		||||
 | 
			
		||||
            This object SHOULD be set by the agent during entry
 | 
			
		||||
            creation, and the value SHOULD NOT change during operation."
 | 
			
		||||
    ::= { entPhySensorEntry 3 }
 | 
			
		||||
 | 
			
		||||
entPhySensorValue OBJECT-TYPE
 | 
			
		||||
    SYNTAX        EntitySensorValue
 | 
			
		||||
    MAX-ACCESS    read-only
 | 
			
		||||
    STATUS        current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "The most recent measurement obtained by the agent for this
 | 
			
		||||
            sensor.
 | 
			
		||||
 | 
			
		||||
            To correctly interpret the value of this object, the
 | 
			
		||||
            associated entPhySensorType, entPhySensorScale, and
 | 
			
		||||
            entPhySensorPrecision objects must also be examined."
 | 
			
		||||
    ::= { entPhySensorEntry 4 }
 | 
			
		||||
 | 
			
		||||
entPhySensorOperStatus OBJECT-TYPE
 | 
			
		||||
    SYNTAX        EntitySensorStatus
 | 
			
		||||
    MAX-ACCESS    read-only
 | 
			
		||||
    STATUS        current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "The operational status of the sensor."
 | 
			
		||||
    ::= { entPhySensorEntry 5 }
 | 
			
		||||
 | 
			
		||||
entPhySensorUnitsDisplay OBJECT-TYPE
 | 
			
		||||
    SYNTAX      SnmpAdminString
 | 
			
		||||
    MAX-ACCESS  read-only
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "A textual description of the data units that should be used
 | 
			
		||||
            in the display of entPhySensorValue."
 | 
			
		||||
    ::= { entPhySensorEntry 6 }
 | 
			
		||||
 | 
			
		||||
entPhySensorValueTimeStamp OBJECT-TYPE
 | 
			
		||||
    SYNTAX        TimeStamp
 | 
			
		||||
    MAX-ACCESS    read-only
 | 
			
		||||
    STATUS        current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "The value of sysUpTime at the time the status and/or value
 | 
			
		||||
            of this sensor was last obtained by the agent."
 | 
			
		||||
    ::= { entPhySensorEntry 7 }
 | 
			
		||||
 | 
			
		||||
entPhySensorValueUpdateRate  OBJECT-TYPE
 | 
			
		||||
    SYNTAX        Unsigned32
 | 
			
		||||
    UNITS         "milliseconds"
 | 
			
		||||
    MAX-ACCESS    read-only
 | 
			
		||||
    STATUS        current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "An indication of the frequency that the agent updates the
 | 
			
		||||
            associated entPhySensorValue object, representing in
 | 
			
		||||
            milliseconds.
 | 
			
		||||
 | 
			
		||||
            The value zero indicates:
 | 
			
		||||
 | 
			
		||||
                - the sensor value is updated on demand (e.g.,
 | 
			
		||||
                  when polled by the agent for a get-request),
 | 
			
		||||
                - the sensor value is updated when the sensor
 | 
			
		||||
                  value changes (event-driven),
 | 
			
		||||
                - the agent does not know the update rate.
 | 
			
		||||
 | 
			
		||||
            "
 | 
			
		||||
    ::= { entPhySensorEntry 8 }
 | 
			
		||||
 | 
			
		||||
--
 | 
			
		||||
-- Conformance Section
 | 
			
		||||
--
 | 
			
		||||
 | 
			
		||||
entitySensorCompliances OBJECT IDENTIFIER
 | 
			
		||||
    ::= { entitySensorConformance 1 }
 | 
			
		||||
entitySensorGroups      OBJECT IDENTIFIER
 | 
			
		||||
    ::= { entitySensorConformance 2 }
 | 
			
		||||
 | 
			
		||||
entitySensorCompliance MODULE-COMPLIANCE
 | 
			
		||||
    STATUS  current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "Describes the requirements for conformance to the Entity
 | 
			
		||||
            Sensor MIB module."
 | 
			
		||||
    MODULE  -- this module
 | 
			
		||||
        MANDATORY-GROUPS { entitySensorValueGroup }
 | 
			
		||||
 | 
			
		||||
    MODULE ENTITY-MIB
 | 
			
		||||
        MANDATORY-GROUPS { entityPhysicalGroup }
 | 
			
		||||
 | 
			
		||||
    ::= { entitySensorCompliances 1 }
 | 
			
		||||
 | 
			
		||||
-- Object Groups
 | 
			
		||||
 | 
			
		||||
entitySensorValueGroup OBJECT-GROUP
 | 
			
		||||
    OBJECTS {
 | 
			
		||||
             entPhySensorType,
 | 
			
		||||
             entPhySensorScale,
 | 
			
		||||
             entPhySensorPrecision,
 | 
			
		||||
             entPhySensorValue,
 | 
			
		||||
             entPhySensorOperStatus,
 | 
			
		||||
             entPhySensorUnitsDisplay,
 | 
			
		||||
             entPhySensorValueTimeStamp,
 | 
			
		||||
             entPhySensorValueUpdateRate
 | 
			
		||||
    }
 | 
			
		||||
    STATUS  current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "A collection of objects representing physical entity sensor
 | 
			
		||||
            information."
 | 
			
		||||
    ::= { entitySensorGroups 1 }
 | 
			
		||||
 | 
			
		||||
END
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
		Reference in New Issue
	