mirror of
https://github.com/librenms/librenms.git
synced 2024-10-07 16:52:45 +00:00
alert rules: added Dell iDRAC alert rules (#8010)
* alert rules: added Dell idrac alert rules to the alerts collection. * Update alert_rules.json * added iDRAC fixed iDRAC naming. * added iDRAC Global System Status Alert
This commit is contained in:
@@ -296,6 +296,14 @@
|
||||
"rule": "%sensors.sensor_current ~ \"[2|5]\" && %sensors.sensor_oid = \".1.3.6.1.4.1.674.10893.1.20.130.4.1.4\"",
|
||||
"name": "Dell Server Disk Array State Failed/Degraded"
|
||||
},
|
||||
{
|
||||
"rule": "%sensors.sensor_current ~ \"[5|6]\" && %sensors.sensor_oid = \".1.3.6.1.4.1.674.10892.1.600.12.1.5\"",
|
||||
"name": "Dell Server PSU State Critical/NonRecvoverable"
|
||||
},
|
||||
{
|
||||
"rule": "%sensors.sensor_current ~ \"[2|6]\" && %sensors.sensor_oid = \".1.3.6.1.4.1.674.10893.1.20.140.1.1.4\"",
|
||||
"name": "Dell Server Virtual Disk Failed/Degraded"
|
||||
},
|
||||
{
|
||||
"rule": "%sensors.sensor_current = \"2\" && %sensors.sensor_oid = \".1.3.6.1.4.1.25506.8.35.9.1.1.1.2\"",
|
||||
"name": "Comware Fan Status failed"
|
||||
@@ -315,6 +323,34 @@
|
||||
{
|
||||
"rule": "%sensors.sensor_current = \"3\" && %sensors.sensor_oid = \".1.3.6.1.4.1.4413.1.1.43.1.15.1.2.1\"",
|
||||
"name": "UBNT EdgeSwitch Chassis state failed"
|
||||
}
|
||||
|
||||
},
|
||||
{
|
||||
"rule": "%sensors.sensor_current ~ \"[3|4]\" && %sensors.sensor_oid = \".1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.4\"",
|
||||
"name": "Dell iDRAC Virtual Disk Failed/Degraded"
|
||||
},
|
||||
{
|
||||
"rule": "%sensors.sensor_current ~ \"5\" && %sensors.sensor_oid = \".1.3.6.1.4.1.674.10892.5.4.1100.30.1.5\"",
|
||||
"name": "Dell iDRAC Processor Status Critical"
|
||||
},
|
||||
{
|
||||
"rule": "%sensors.sensor_current ~ \"5\" && %sensors.sensor_oid = \".1.3.6.1.4.1.674.10892.5.4.1100.50.1.5\"",
|
||||
"name": "Dell iDRAC Memory Status Critical"
|
||||
},
|
||||
{
|
||||
"rule": "%sensors.sensor_current ~ \"10\" && %sensors.sensor_oid = \".1.3.6.1.4.1.674.10892.5.4.600.20.1.5\"",
|
||||
"name": "Dell iDRAC Voltage Probe Status Failed"
|
||||
},
|
||||
{
|
||||
"rule": "%sensors.sensor_current ~ \"10\" && %sensors.sensor_oid = \".1.3.6.1.4.1.674.10892.5.4.600.30.1.5\"",
|
||||
"name": "Dell iDRAC Amperage Probe Status Failed"
|
||||
},
|
||||
{
|
||||
"rule": "%sensors.sensor_current ~ \"10\" && %sensors.sensor_oid = \".1.3.6.1.4.1.674.10892.5.4.600.50.1.5\"",
|
||||
"name": "Dell iDRAC Battery Status Failed"
|
||||
},
|
||||
{
|
||||
"rule": "%sensors.sensor_current ~ \"[5|6]\" && %sensors.sensor_oid = \".1.3.6.1.4.1.674.10892.2.2.1\"",
|
||||
"name": "Dell iDRAC Global System Status Critical/NonRecoverable"
|
||||
}
|
||||
|
||||
]
|
||||
|
||||
Reference in New Issue