Add generic PSU status failed alert rule template (#13821)

* Add Juniper PSU status failed alert rule template

* Converting Juniper PSU failed default alert into a more generic one (Thanks ottorei)
This commit is contained in:
geg347
2022-03-13 17:23:04 +01:00
committed by GitHub
parent 379627243a
commit a7019bf8f1

View File

@@ -353,6 +353,10 @@
"rule": "sensors.sensor_current = \"8\" && sensors.sensor_oid = \".1.3.6.1.4.1.9.9.13.1.5.1.3\"",
"name": "Cisco PSU status failed"
},
{
"builder": {"condition":"AND","rules":[{"id":"sensors.sensor_alert","field":"sensors.sensor_alert","type":"string","input":"text","operator":"equal","value":"1"},{"condition":"OR","rules":[{"id":"sensors.sensor_descr","field":"sensors.sensor_descr","type":"string","input":"text","operator":"regex","value":".*Power Supply.*"},{"id":"sensors.sensor_descr","field":"sensors.sensor_descr","type":"string","input":"text","operator":"regex","value":".*PEM.*"},{"id":"sensors.sensor_descr","field":"sensors.sensor_descr","type":"string","input":"text","operator":"regex","value":".*PSU.*"}]},{"condition":"OR","rules":[{"id":"macros.state_sensor_warning","field":"macros.state_sensor_warning","type":"boolean","input":"radio","operator":"equal","value":"1"},{"id":"macros.state_sensor_critical","field":"macros.state_sensor_critical","type":"boolean","input":"radio","operator":"equal","value":"1"}]}],"valid":true},
"name": "Generic PSU status failed"
},
{
"rule": "sensors.sensor_current = \"3\" && sensors.sensor_oid = \".1.3.6.1.4.1.4413.1.1.43.1.15.1.2.1\"",
"name": "UBNT EdgeSwitch Chassis state failed"