split database update file again to cut down on the churn of adding the index every time again (yes, apparently mysql does that even if the index is already there)

git-svn-id: http://www.observium.org/svn/observer/trunk@1531 61d68cd4-352d-0410-923a-c4978735b2b8
This commit is contained in:
Tom Laermans
2010-07-29 19:27:47 +00:00
parent 0e7561e56f
commit ac8b98e9a0
2 changed files with 7 additions and 44 deletions

View File

@ -1,45 +1,3 @@
CREATE TABLE IF NOT EXISTS `toner` ( `toner_id` int(11) NOT NULL auto_increment, `device_id` int(11) NOT NULL default '0', `toner_index` int(11) NOT NULL, `toner_type` varchar(64) NOT NULL, `toner_oid` varchar(64) NOT NULL, `toner_descr` varchar(32) NOT NULL default '', `toner_capacity` int(11) NOT NULL default '0', `toner_current` int(11) NOT NULL default '0', PRIMARY KEY (`toner_id`), KEY `device_id` (`device_id`)) ENGINE=InnoDB DEFAULT CHARSET=latin1;
ALTER TABLE `mempools` CHANGE `mempool_descr` `mempool_descr` VARCHAR( 64 ) CHARACTER SET latin1 COLLATE latin1_swedish_ci NOT NULL;
ALTER TABLE `processors` CHANGE `processor_descr` `processor_descr` VARCHAR( 64 ) CHARACTER SET latin1 COLLATE latin1_swedish_ci NOT NULL;
DROP TABLE `cempMemPool`;
DROP TABLE `cpmCPU`;
DROP TABLE `cmpMemPool`;
ALTER TABLE `mempools` CHANGE `mempool_used` `mempool_used` BIGINT( 16 ) NOT NULL ,CHANGE `mempool_free` `mempool_free` BIGINT( 16 ) NOT NULL ,CHANGE `mempool_total` `mempool_total` BIGINT( 16 ) NOT NULL ,CHANGE `mempool_largestfree` `mempool_largestfree` BIGINT( 16 ) NULL DEFAULT NULL ,CHANGE `mempool_lowestfree` `mempool_lowestfree` BIGINT( 16 ) NULL DEFAULT NULL ;
ALTER TABLE `ports` ADD `port_descr_type` VARCHAR( 32 ) NULL DEFAULT NULL AFTER `device_id` ,ADD `port_descr_descr` VARCHAR( 64 ) NULL DEFAULT NULL AFTER `port_descr_type` ,ADD `port_descr_circuit` VARCHAR( 64 ) NULL DEFAULT NULL AFTER `port_descr_descr` ,ADD `port_descr_speed` VARCHAR( 32 ) NULL DEFAULT NULL AFTER `port_descr_circuit` ,ADD `port_descr_notes` VARCHAR( 128 ) NULL DEFAULT NULL AFTER `port_descr_speed`;
CREATE TABLE IF NOT EXISTS `frequency` ( `freq_id` int(11) NOT NULL auto_increment, `device_id` int(11) NOT NULL default '0', `freq_oid` varchar(64) NOT NULL, `freq_index` varchar(8) NOT NULL, `freq_type` varchar(32) NOT NULL, `freq_descr` varchar(32) NOT NULL default '', `freq_precision` int(11) NOT NULL default '1', `freq_current` float default NULL, `freq_limit` float default NULL, `freq_limit_low` float default NULL, PRIMARY KEY (`freq_id`), KEY `freq_host` (`device_id`)) ENGINE=MyISAM AUTO_INCREMENT=189 DEFAULT CHARSET=latin1;
ALTER TABLE `temperature` CHANGE `temp_index` `temp_index` int(11) NOT NULL;
CREATE TABLE IF NOT EXISTS `current` ( `current_id` int(11) NOT NULL auto_increment, `device_id` int(11) NOT NULL default '0', `current_oid` varchar(64) NOT NULL, `current_index` varchar(8) NOT NULL, `current_type` varchar(32) NOT NULL, `current_descr` varchar(32) NOT NULL default '', `current_precision` int(11) NOT NULL default '1', `current_current` float default NULL, `current_limit` float default NULL, `current_limit_warn` float default NULL, `current_limit_low` float default NULL, PRIMARY KEY (`current_id`), KEY `current_host` (`device_id`)) ENGINE=MyISAM AUTO_INCREMENT=189 DEFAULT CHARSET=latin1;
ALTER TABLE `devices` ADD `serial` text default NULL;
ALTER TABLE `temperature` CHANGE `temp_index` `temp_index` VARCHAR(32) NOT NULL;
ALTER TABLE `ports` CHANGE `ifDescr` `ifDescr` VARCHAR(255) NOT NULL;
CREATE TABLE IF NOT EXISTS `ucd_diskio` ( `diskio_id` int(11) NOT NULL AUTO_INCREMENT, `device_id` int(11) NOT NULL, `diskio_index` int(11) NOT NULL, `diskio_descr` varchar(32) NOT NULL, PRIMARY KEY (`diskio_id`)) ENGINE=MyISAM DEFAULT CHARSET=latin1 AUTO_INCREMENT=11 ;
ALTER TABLE `eventlog` CHANGE `type` `type` VARCHAR( 64 ) CHARACTER SET latin1 COLLATE latin1_swedish_ci NULL DEFAULT NULL;
ALTER TABLE `bills` ADD `bill_custid` VARCHAR( 64 ) NOT NULL ,ADD `bill_ref` VARCHAR( 64 ) NOT NULL ,ADD `bill_notes` VARCHAR( 256 ) NOT NULL;
CREATE TABLE IF NOT EXISTS `applications` ( `app_id` int(11) NOT NULL AUTO_INCREMENT, `device_id` int(11) NOT NULL, `app_type` varchar(64) NOT NULL, PRIMARY KEY (`app_id`)) ENGINE=MyISAM DEFAULT CHARSET=latin1 AUTO_INCREMENT=5 ;
## 0.10.6
CREATE TABLE IF NOT EXISTS `sensors` ( `sensor_id` int(11) NOT NULL auto_increment, `sensor_class` varchar(64) NOT NULL, `device_id` int(11) NOT NULL default '0', `sensor_oid` varchar(64) NOT NULL, `sensor_index` varchar(8) NOT NULL, `sensor_type` varchar(32) NOT NULL, `sensor_descr` varchar(32) NOT NULL default '', `sensor_precision` int(11) NOT NULL default '1', `sensor_current` float default NULL, `sensor_limit` float default NULL, `sensor_limit_warn` float default NULL, `sensor_limit_low` float default NULL, `sensor_limit_low_warn` float default NULL, PRIMARY KEY (`sensor_id`), KEY `sensor_host` (`device_id`)) ENGINE=MyISAM AUTO_INCREMENT=189 DEFAULT CHARSET=latin1;
ALTER TABLE `devices` CHANGE `type` `type` VARCHAR(20) NOT NULL;
ALTER TABLE `voltage` CHANGE `volt_index` `volt_index` VARCHAR(10) NOT NULL;
ALTER TABLE `frequency` CHANGE `freq_index` `freq_index` VARCHAR(10) NOT NULL;
ALTER TABLE `sensors` CHANGE `sensor_index` `sensor_index` VARCHAR(10) NOT NULL;
DROP TABLE `fanspeed`;
DROP TABLE `temperature`;
DROP TABLE `voltage`;
DROP TABLE `current`;
ALTER TABLE `sensors` ADD `entPhysicalIndex` VARCHAR( 16 ) NULL;
ALTER TABLE `sensors` ADD `entPhysicalIndex_measured` VARCHAR(16) NULL;
ALTER TABLE `processors` DROP INDEX `cpuCPU_id`;
ALTER TABLE `processors` ADD INDEX ( `device_id` );
ALTER TABLE `ucd_diskio` ADD INDEX ( `device_id` );
ALTER TABLE `storage` ADD INDEX ( `device_id` );
ALTER TABLE `mac_accounting` ADD INDEX ( `interface_id` );
ALTER TABLE `ipv4_addresses` ADD INDEX ( `interface_id` );
ALTER TABLE `ipv6_addresses` ADD INDEX ( `interface_id` );
ALTER TABLE `ipv4_mac` ADD INDEX ( `interface_id` );
CREATE TABLE IF NOT EXISTS `ports_adsl` ( `interface_id` int(11) NOT NULL, `port_adsl_updated` timestamp NOT NULL DEFAULT CURRENT_TIMESTAMP, `adslLineCoding` varchar(8) COLLATE utf8_bin NOT NULL, `adslLineType` varchar(16) COLLATE utf8_bin NOT NULL, `adslAtucInvVendorID` varchar(8) COLLATE utf8_bin NOT NULL, `adslAtucInvVersionNumber` varchar(8) COLLATE utf8_bin NOT NULL, `adslAtucCurrSnrMgn` decimal(5,1) NOT NULL, `adslAtucCurrAtn` decimal(5,1) NOT NULL, `adslAtucCurrOutputPwr` decimal(5,1) NOT NULL, `adslAtucCurrAttainableRate` int(11) NOT NULL, `adslAtucChanCurrTxRate` int(11) NOT NULL, `adslAturInvSerialNumber` varchar(8) COLLATE utf8_bin NOT NULL, `adslAturInvVendorID` varchar(8) COLLATE utf8_bin NOT NULL, `adslAturInvVersionNumber` varchar(8) COLLATE utf8_bin NOT NULL, `adslAturChanCurrTxRate` int(11) NOT NULL, `adslAturCurrSnrMgn` decimal(5,1) NOT NULL, `adslAturCurrAtn` decimal(5,1) NOT NULL, `adslAturCurrOutputPwr` decimal(5,1) NOT NULL, `adslAturCurrAttainableRate` int(11) NOT NULL, UNIQUE KEY `interface_id` (`interface_id`)) ENGINE=InnoDB DEFAULT CHARSET=utf8 COLLATE=utf8_bin;
## 0.10.7
ALTER TABLE `devices` ADD `last_polled_timetaken` DOUBLE( 5, 2 ) NOT NULL AFTER `last_polled` , ADD `last_discovered_timetaken` DOUBLE( 5, 2 ) NOT NULL AFTER `last_polled_timetaken`;
CREATE TABLE IF NOT EXISTS `perf_times` ( `type` varchar(8) NOT NULL, `doing` varchar(64) NOT NULL, `start` int(11) NOT NULL, `duration` double(5,2) NOT NULL, `devices` int(11) NOT NULL, KEY `type` (`type`)) ENGINE=InnoDB DEFAULT CHARSET=utf8 COLLATE=utf8_bin;
## 0.10.7.1
ALTER TABLE `bills` ADD `bill_autoadded` BOOLEAN NOT NULL DEFAULT '0';
ALTER TABLE `bill_ports` ADD `bill_port_autoadded` BOOLEAN NOT NULL DEFAULT '0';

View File

@ -69,11 +69,16 @@ if (file_exists('.svn'))
if ($dbu_rev+0 > $db_rev)
{
echo "SVN revision changed.\n";
if($db_rev+0 < "1000") {
echo("SVN revision changed.\nRunning pre-revision 1000 SQL update script...\n");
echo("Running pre-revision 1000 SQL update script...\n");
shell_exec("scripts/update-sql.php database-update-pre1000.sql");
}
echo("SVN revision changed.\nRunning development SQL update script from r$db_rev to r" . trim($dbu_rev) . "...\n");
if($db_rev+0 < "1435") {
echo("Running pre-revision 1435 SQL update script...\n");
shell_exec("scripts/update-sql.php database-update-pre1435.sql");
}
echo("Running development SQL update script to update from r$db_rev to r" . trim($dbu_rev) . "...\n");
shell_exec("scripts/update-sql.php database-update.sql");
if ($db_rev == 0)
{