correct getTypes - remove change to lower case

This commit is contained in:
SourceDoctor
2020-04-17 22:49:59 +02:00
parent fbfce501a2
commit cdbf8e98e4
3 changed files with 21 additions and 21 deletions
@@ -89,7 +89,7 @@ class EventlogController extends TableController
return '<b>' . Url::portLink($port, $port->getShortLabel()) . '</b>';
}
}
} elseif (in_array(strtolower($eventlog->type), \App\Models\Sensor::getTypes())) {
} elseif (in_array($eventlog->type, \App\Models\Sensor::getTypes())) {
if (is_numeric($eventlog->reference)) {
$sensor = $eventlog->related;
if (isset($sensor)) {
+18 -18
View File
@@ -6,7 +6,6 @@ class Sensor extends DeviceRelatedModel
{
public $timestamps = false;
protected $primaryKey = 'sensor_id';
protected static $icons = array(
'airflow' => 'angle-double-right',
'ber' => 'sort-amount-desc',
@@ -56,31 +55,32 @@ class Sensor extends DeviceRelatedModel
public static function getTypes()
{
return ['airflow',
return ['Airflow',
'ber',
'Battery Charge',
'chromatic_dispersion',
'cooling',
'Cooling',
'count',
'current',
'dbm',
'Current',
'dBm',
'delay',
'eer',
'fanspeed',
'frequency',
'humidity',
'load',
'Energy Efficiency Ratio',
'Fanspeed',
'Frequency',
'Humidity',
'Load',
'power_consumed',
'power_factor',
'power',
'pressure',
'Power',
'Pressure',
'quality_factor',
'runtime',
'signal',
'Runtime',
'Wireless',
'snr',
'state',
'temperature',
'voltage',
'waterflow',
'State',
'Temperature',
'Voltage',
'Water Flow Rate',
];
}
+2 -2
View File
@@ -76,8 +76,8 @@ class AppServiceProvider extends ServiceProvider
private function configureMorphAliases()
{
$sensor_types = [];
foreach (Sensor::getTypes() as $type) {
$sensor_types[ucwords($type)] = \App\Models\Sensor::class;
foreach (Sensor::getTypes() as $sensor_type) {
$sensor_types[$sensor_type] = \App\Models\Sensor::class;
};
Relation::morphMap(array_merge([
'interface' => \App\Models\Port::class,