CTRON-BDG-MIB DEFINITIONS ::= BEGIN
 | 
						|
 | 
						|
        --  ctron-bdg-mib.txt
 | 
						|
        --  Part Number: 2170561-01
 | 
						|
        --  Revision: 1.01.01
 | 
						|
        --  Date: June 22, 1996
 | 
						|
 | 
						|
        --  Cabletron Systems, Inc.
 | 
						|
        --  35 Industrial Way, P.O. Box 5005
 | 
						|
        --  Rochester, NH 03867-0505
 | 
						|
        --  (603) 332-9400
 | 
						|
        --  support@ctron.com
 | 
						|
 | 
						|
        --  This module provides authoritative definitions for Cabletron's
 | 
						|
        --  enterprise-specific common MIB.
 | 
						|
        --
 | 
						|
        --  This module will be extended, as required.
 | 
						|
        --
 | 
						|
 | 
						|
        --  Cabletron Systems reserves the right to make changes in 
 | 
						|
        --  specification and other information contained in this document 
 | 
						|
        --  without prior notice.  The reader should consult Cabletron Systems
 | 
						|
        --  to determine whether any such changes have been made.
 | 
						|
        --
 | 
						|
        --  In no event shall Cabletron Systems be liable for any incidental, 
 | 
						|
        --  indirect, special, or consequential damages whatsoever (including 
 | 
						|
        --  but not limited to lost profits) arising out of or related to this
 | 
						|
        --  document or the information contained in it, even if Cabletron
 | 
						|
        --  Systems has been advised of, known, or should have known, the 
 | 
						|
        --  possibility of such damages.
 | 
						|
        --
 | 
						|
        --  Cabletron grants vendors, end-users, and other interested parties
 | 
						|
        --  a non-exclusive license to use this Specification in connection
 | 
						|
        --  with the management of Cabletron products.
 | 
						|
 | 
						|
        --  Copyright August 95 Cabletron Systems
 | 
						|
 | 
						|
 | 
						|
        IMPORTS
 | 
						|
                OBJECT-TYPE     FROM RFC-1212
 | 
						|
                bridge, layerMgmt
 | 
						|
                        FROM IRM-OIDS
 | 
						|
                Counter     FROM RFC1155-SMI;
 | 
						|
 | 
						|
 | 
						|
bridgeRev1  OBJECT IDENTIFIER ::= { bridge 1 }
 | 
						|
bdgdevice      OBJECT IDENTIFIER ::= { bridgeRev1 1 }
 | 
						|
 | 
						|
bdgPort        OBJECT IDENTIFIER ::= { bridgeRev1 2 }
 | 
						|
 | 
						|
filterDB    OBJECT IDENTIFIER ::= { bridgeRev1 3 }
 | 
						|
 | 
						|
trapTypes   OBJECT IDENTIFIER ::= { bridgeRev1 4 }
 | 
						|
 | 
						|
bdgTables   OBJECT IDENTIFIER ::= { bridgeRev1 5 }
 | 
						|
 | 
						|
acqDB       OBJECT IDENTIFIER ::= { filterDB 1 }
 | 
						|
 | 
						|
permDB      OBJECT IDENTIFIER ::= { filterDB 2 }
 | 
						|
 | 
						|
specialDB   OBJECT IDENTIFIER ::= { filterDB 3 }
 | 
						|
 | 
						|
acqStats    OBJECT IDENTIFIER ::= { acqDB 1 }
 | 
						|
 | 
						|
acqOptions  OBJECT IDENTIFIER ::= { acqDB 2 }
 | 
						|
 | 
						|
permStats   OBJECT IDENTIFIER ::= { permDB 1 }
 | 
						|
 | 
						|
permOptions OBJECT IDENTIFIER ::= { permDB 2 }
 | 
						|
 | 
						|
specStats   OBJECT IDENTIFIER ::= { specialDB 1 }
 | 
						|
 | 
						|
specFilters OBJECT IDENTIFIER ::= { specialDB 2 }
 | 
						|
 | 
						|
 | 
						|
-- Device Object Definitions
 | 
						|
--
 | 
						|
--      This section defines the objects under the Device node.
 | 
						|
--
 | 
						|
-- Instance Identifiers for Device Objects
 | 
						|
--
 | 
						|
--      There is only one instance of a Device object, thus the Instance
 | 
						|
--      Identifier is 0.
 | 
						|
--
 | 
						|
-- Device Objects
 | 
						|
 | 
						|
 | 
						|
bdgdeviceDisableBdg OBJECT-TYPE 
 | 
						|
SYNTAX INTEGER 
 | 
						|
     {
 | 
						|
          disableBridge (0),
 | 
						|
          enableBridge  (1)
 | 
						|
     }
 | 
						|
ACCESS read-write
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
     "Indicates if the bridge will be disabled."
 | 
						|
::= { bdgdevice 1 }
 | 
						|
 | 
						|
 | 
						|
bdgdeviceRestoreSettings OBJECT-TYPE
 | 
						|
SYNTAX INTEGER 
 | 
						|
        {
 | 
						|
                restoreSettings (0)
 | 
						|
        }
 | 
						|
ACCESS read-write
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "Restore the following settings to their default values:
 | 
						|
                Bridge Name to ETHERNET_BRIDGE,
 | 
						|
                Location to LOCAL,
 | 
						|
                Port 1 Name to PORT_1,
 | 
						|
                Port 2 Name to PORT_2,
 | 
						|
                Port 1 Network Name to LAN_1,
 | 
						|
                Port 2 Network Name to LAN_2,
 | 
						|
                Ageing Time for Acquired Database to 300 seconds,
 | 
						|
                Erase the acquired database,
 | 
						|
                Erase the permanent database,
 | 
						|
                Place sixteen default multicast addresses into
 | 
						|
                the permanent and acquired databases,
 | 
						|
                Type of Spanning Tree to 802.1,
 | 
						|
                Type of Filtering to IEEE 802.1,
 | 
						|
                Bridge Max Age to 20 seconds,
 | 
						|
                Bridge Forward Delay to 15 seconds,
 | 
						|
                Bridge Hello Time to 2 seconds,
 | 
						|
                Bridge Priority to 8000,
 | 
						|
                Port 1 Priority to 80,
 | 
						|
                Port 2 Priority to 80,
 | 
						|
                Port 1 Path Cost to 100,
 | 
						|
                Port 2 Path Cost to 100,
 | 
						|
                Restart the bridge."
 | 
						|
::= { bdgdevice 2 }
 | 
						|
 | 
						|
 | 
						|
bdgdeviceBdgName OBJECT-TYPE
 | 
						|
SYNTAX OCTET STRING
 | 
						|
ACCESS read-write
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The user-defined name (up to 32 characters long) of the bridge.
 | 
						|
        The default bridge name is ETHERNET_BRIDGE."
 | 
						|
::=     { bdgdevice 4 }
 | 
						|
 | 
						|
 | 
						|
bdgdeviceNumPorts OBJECT-TYPE
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The number of ports present on the bridge."
 | 
						|
::= { bdgdevice 5 }
 | 
						|
 | 
						|
 | 
						|
bdgdeviceType OBJECT-TYPE
 | 
						|
SYNTAX OCTET STRING
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The type of bridge, NB25E, IRBM, or NB20E."
 | 
						|
::= { bdgdevice 6 }
 | 
						|
 | 
						|
 | 
						|
bdgdeviceVersion OBJECT-TYPE
 | 
						|
SYNTAX OCTET STRING
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The release version of the firmware installed in the bridge."
 | 
						|
::= { bdgdevice 7 }
 | 
						|
 | 
						|
 | 
						|
bdgdeviceLocation OBJECT-TYPE
 | 
						|
SYNTAX OCTET STRING
 | 
						|
ACCESS read-write
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The user-defined name to indicate the location of the bridge on
 | 
						|
        the network. The default location name is LOCAL."
 | 
						|
::= { bdgdevice 8 }
 | 
						|
 | 
						|
 | 
						|
bdgdeviceStatus OBJECT-TYPE
 | 
						|
SYNTAX OCTET STRING
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The status of the bridge, ON-LINE, STAND BY or DISABLED."
 | 
						|
::= { bdgdevice 9 }
 | 
						|
 | 
						|
 | 
						|
bdgdeviceRestartBdg OBJECT-TYPE
 | 
						|
SYNTAX INTEGER 
 | 
						|
        {
 | 
						|
                restartBridge (0)
 | 
						|
        }
 | 
						|
ACCESS read-write
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "Force the bridge to undergo a software reset."
 | 
						|
::= { bdgdevice 10 }
 | 
						|
 | 
						|
 | 
						|
bdgdeviceFrFwd OBJECT-TYPE
 | 
						|
SYNTAX Counter
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The number of frames forwarded by the bridge."
 | 
						|
::= { bdgdevice 11 }
 | 
						|
 | 
						|
 | 
						|
bdgdeviceFrRx OBJECT-TYPE
 | 
						|
SYNTAX Counter
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The number of frames received by the bridge."
 | 
						|
::= { bdgdevice 12 }
 | 
						|
 | 
						|
 | 
						|
bdgdeviceFrFlt OBJECT-TYPE
 | 
						|
SYNTAX Counter
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The number of frames filtered by the bridge."
 | 
						|
::= { bdgdevice 13 }
 | 
						|
 | 
						|
 | 
						|
bdgdeviceErr OBJECT-TYPE
 | 
						|
SYNTAX Counter
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The total number of network errors that have occurred."
 | 
						|
::= { bdgdevice 14 }
 | 
						|
 | 
						|
 | 
						|
bdgdeviceSwitchSetting OBJECT-TYPE
 | 
						|
SYNTAX OCTET STRING
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "Indicates the current switch settings read from the bridge
 | 
						|
        hardware."
 | 
						|
::= { bdgdevice 15 }
 | 
						|
 | 
						|
 | 
						|
bdgdeviceNumRestarts OBJECT-TYPE
 | 
						|
SYNTAX Counter
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The number of times the bridge has been powered up or restarted."
 | 
						|
::= { bdgdevice 16 }
 | 
						|
 | 
						|
 | 
						|
bdgdeviceTypeFiltering OBJECT-TYPE
 | 
						|
SYNTAX INTEGER 
 | 
						|
        {
 | 
						|
                ieee8021 (0),
 | 
						|
                specialDB (1),
 | 
						|
                both      (2)
 | 
						|
        }
 | 
						|
ACCESS read-write
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The type of filtering to be performed by the bridge. The default
 | 
						|
        is IEEE 802.1."
 | 
						|
::= { bdgdevice 17 }
 | 
						|
 | 
						|
 | 
						|
bdgdeviceSTAProtocol OBJECT-TYPE
 | 
						|
SYNTAX INTEGER 
 | 
						|
        {
 | 
						|
                ieee8021 (0),
 | 
						|
                dec   (1),
 | 
						|
                none  (2)
 | 
						|
        }
 | 
						|
ACCESS read-write
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The spanning tree algorithm under which the bridge is operating.
 | 
						|
        The selections are as follows:
 | 
						|
                - IEEE 802.1 compliant spanning tree algorithm
 | 
						|
                  environment (802.1)
 | 
						|
                - DEC LAN Bridge 100 environment (DEC)
 | 
						|
                - Without the spanning tree algorithm enabled (NONE)
 | 
						|
        The default is 802.1."
 | 
						|
::= { bdgdevice 18 }
 | 
						|
 | 
						|
 | 
						|
bdgdeviceBridgeID OBJECT-TYPE
 | 
						|
SYNTAX OCTET STRING
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The unique identifier of the bridge. The first two bytes of the
 | 
						|
        identifier are the bridge priority and the last six bytes are the
 | 
						|
        Ethernet address."
 | 
						|
::= { bdgdevice 19 }
 | 
						|
 | 
						|
 | 
						|
bdgdeviceTopChgCnt OBJECT-TYPE
 | 
						|
SYNTAX Counter
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The number of times the bridge's Topology Change Flag has been
 | 
						|
        changed since the bridge was powered up or initialized."
 | 
						|
::= { bdgdevice 20 }
 | 
						|
 | 
						|
 | 
						|
bdgdeviceRootCost OBJECT-TYPE
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The cost of the path to the root from this bridge."
 | 
						|
::= { bdgdevice 21 }
 | 
						|
 | 
						|
 | 
						|
bdgdeviceRootPort OBJECT-TYPE
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The port identifier for the port which offers the lowest cost
 | 
						|
        path to the root, i.e. that port for which the sum of the values
 | 
						|
        of the designated cost and path cost parameters held for the port
 | 
						|
        is lowest."
 | 
						|
::= { bdgdevice 22 }
 | 
						|
 | 
						|
 | 
						|
bdgdeviceHelloTime OBJECT-TYPE
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The time interval between the transmission of Configuration
 | 
						|
        BPDU's by a bridge which is attempting to become the root or is
 | 
						|
        the root."
 | 
						|
::= { bdgdevice 23 }
 | 
						|
 | 
						|
 | 
						|
bdgdeviceBdgMaxAge OBJECT-TYPE
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-write
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The value of the Max Age parameter when the bridge is the root
 | 
						|
        or is attempting to become the root. A time of 6 to 40 seconds is
 | 
						|
        allowed. The default is 20 seconds."
 | 
						|
::= { bdgdevice 24 }
 | 
						|
 | 
						|
 | 
						|
bdgdeviceBdgFwdDly OBJECT-TYPE
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-write
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The value of the forward delay parameter when the bridge is the
 | 
						|
        root or is attempting to become the root. A time of 4 to 30
 | 
						|
        seconds is allowed."
 | 
						|
::= { bdgdevice 25 }
 | 
						|
 | 
						|
 | 
						|
bdgdeviceTimeTopChg OBJECT-TYPE
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The time in seconds that has elapsed since the bridge's Topology
 | 
						|
        Change Flag last recorded the value of a topology change."
 | 
						|
::= { bdgdevice 26 }
 | 
						|
 | 
						|
 | 
						|
bdgdeviceTopChg OBJECT-TYPE
 | 
						|
SYNTAX INTEGER 
 | 
						|
{
 | 
						|
        noTopologyChangeInProgress (0),
 | 
						|
        topologyChangeInProgress   (1)
 | 
						|
}
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "Indicates if a bridge topology change is in progress."
 | 
						|
::= { bdgdevice 27 }
 | 
						|
 | 
						|
 | 
						|
bdgdeviceDesigRoot OBJECT-TYPE
 | 
						|
SYNTAX OCTET STRING
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The unique identifier of the bridge recorded as the root."
 | 
						|
::= { bdgdevice 28 }
 | 
						|
 | 
						|
 | 
						|
bdgdeviceMaxAge OBJECT-TYPE
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The maximum age of received protocol information before it is
 | 
						|
        discarded."
 | 
						|
::= { bdgdevice 29 }
 | 
						|
 | 
						|
 | 
						|
bdgdeviceHoldTime OBJECT-TYPE
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The minimum time period elapsing between the transmission of
 | 
						|
        configuration BPDU's through a given bridge port."
 | 
						|
::= { bdgdevice 30 }
 | 
						|
 | 
						|
 | 
						|
bdgdeviceFwdDly OBJECT-TYPE
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The time spent in the listening state while moving from the
 | 
						|
        blocking state to the learning state, or the time spent in the
 | 
						|
        learning state while moving from the listening state to the
 | 
						|
        forwarding state."
 | 
						|
::= { bdgdevice 31 }
 | 
						|
 | 
						|
 | 
						|
bdgdeviceBdgHello OBJECT-TYPE
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-write
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The value of the Hello Time parameter when the bridge is the
 | 
						|
        root or is attempting to become the root. A time of 1 to 10
 | 
						|
        seconds is allowed. The default is 2 seconds."
 | 
						|
::= { bdgdevice 32 }
 | 
						|
 | 
						|
 | 
						|
bdgdeviceBdgPriority OBJECT-TYPE
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-write
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The part of the bridge address that contains the identifier used
 | 
						|
        in the spanning tree for priority comparisons. Allowed range is 0
 | 
						|
        through FFFF. The default is 8000."
 | 
						|
::= { bdgdevice 33 }
 | 
						|
 | 
						|
 | 
						|
bdgdeviceResetCounts OBJECT-TYPE
 | 
						|
SYNTAX INTEGER 
 | 
						|
        {
 | 
						|
                resetCounts (0)
 | 
						|
        }
 | 
						|
ACCESS read-write
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "Reset all counters to zero."
 | 
						|
::= { bdgdevice 34 }
 | 
						|
 | 
						|
 | 
						|
bdgdeviceUptime OBJECT-TYPE
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The time, in seconds, that has elapsed since the bridge was last
 | 
						|
        reset or initialized."
 | 
						|
::= { bdgdevice 35 }
 | 
						|
 | 
						|
 | 
						|
bdgdeviceTrapType OBJECT-TYPE
 | 
						|
SYNTAX OBJECT IDENTIFIER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "Contains the object identifier of the first VarBinding in the
 | 
						|
        last trap generated by the bridge."
 | 
						|
::= { bdgdevice 36 }
 | 
						|
 | 
						|
 | 
						|
-- Port Object Definitions
 | 
						|
--
 | 
						|
--      This section defines the objects under the Port node.
 | 
						|
--
 | 
						|
-- Instance Identifiers for Port Objects
 | 
						|
--
 | 
						|
--      The Instance Identifier for port objects is the number of the port on
 | 
						|
--      the bridge. Valid instance identifiers for the ports on the IRBM,
 | 
						|
--      NB25E, and NB20E bridges are 1 and 2.
 | 
						|
--
 | 
						|
-- Port Objects
 | 
						|
 | 
						|
 | 
						|
bdgPortAddress OBJECT-TYPE
 | 
						|
SYNTAX OCTET STRING
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The Ethernet address of the port."
 | 
						|
::= { bdgPort 1 }
 | 
						|
 | 
						|
bdgPortName OBJECT-TYPE
 | 
						|
SYNTAX OCTET STRING
 | 
						|
ACCESS read-write
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The user-defined name assigned to the port. The default port 1
 | 
						|
        name is PORT_1 and the default Port 2 name is PORT_2."
 | 
						|
::= { bdgPort 2 }
 | 
						|
 | 
						|
bdgPortType OBJECT-TYPE
 | 
						|
SYNTAX OCTET STRING
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The IEEE specification the port meets, e.g. 802.3."
 | 
						|
::= { bdgPort 3 }
 | 
						|
 | 
						|
bdgPortStatus OBJECT-TYPE
 | 
						|
SYNTAX OCTET STRING
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The status in which the port is operating. The status messages
 | 
						|
        for Ports 1 and 2 are:
 | 
						|
 | 
						|
                OFF - The port is off, due to a failed network interface
 | 
						|
                chip associated with that port.
 | 
						|
 | 
						|
                OK/SQE ON - The port is communicating with the network
 | 
						|
                and the transceiver making the connection to the network
 | 
						|
                has SQE enabled.
 | 
						|
 | 
						|
                OK/SQE OFF - The port is communicating with the network
 | 
						|
                and the transceiver making the connection to the network
 | 
						|
                has SQE disabled.
 | 
						|
 | 
						|
                CARRIER LOST - Communication with the network has not
 | 
						|
                been established or has been lost."
 | 
						|
::= { bdgPort 4 }
 | 
						|
 | 
						|
bdgPortNetName OBJECT-TYPE
 | 
						|
SYNTAX OCTET STRING
 | 
						|
ACCESS read-write
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The user-defined name assigned to a network segment connected to
 | 
						|
        the port. The default network name for Port 1 is LAN_1 and the
 | 
						|
        default network name for Port 2 is LAN_2."
 | 
						|
::= { bdgPort 5 }
 | 
						|
 | 
						|
bdgPortFrRx OBJECT-TYPE
 | 
						|
SYNTAX Counter
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The number of frames received at the specified port."
 | 
						|
::= { bdgPort 6 }
 | 
						|
 | 
						|
bdgPortDisInb OBJECT-TYPE
 | 
						|
SYNTAX Counter
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The total number of valid frames that were received at the port
 | 
						|
        but then discarded by the bridge in the forwarding process."
 | 
						|
::= { bdgPort 7 }
 | 
						|
 | 
						|
bdgPortFwdOutb OBJECT-TYPE
 | 
						|
SYNTAX Counter
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The number of frames forwarded successfully to the appropriate
 | 
						|
        port."
 | 
						|
::= { bdgPort 8 }
 | 
						|
 | 
						|
bdgPortDisLOB OBJECT-TYPE
 | 
						|
SYNTAX Counter
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The number of packets that were discarded by the bridge because
 | 
						|
        of a lack of buffer space to maintain the data."
 | 
						|
::= { bdgPort 9 }
 | 
						|
 | 
						|
bdgPortDisTDE OBJECT-TYPE
 | 
						|
SYNTAX Counter
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The number of frames that were intended for forwarding but were
 | 
						|
        discarded when the maximum time period set for transmission was
 | 
						|
        exceeded before forwarding was possible."
 | 
						|
::= { bdgPort 10 }
 | 
						|
 | 
						|
bdgPortDisErr OBJECT-TYPE
 | 
						|
SYNTAX Counter
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The number of frames that could not be transmitted because the
 | 
						|
        frame was too large for the attached network (1526 bytes,
 | 
						|
        including preamble, for 802.3 networks)."
 | 
						|
::= { bdgPort 11 }
 | 
						|
 | 
						|
bdgPortColl OBJECT-TYPE
 | 
						|
SYNTAX Counter
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The number of collisions that have occurred on the network at
 | 
						|
        the specified port."
 | 
						|
::= { bdgPort 12 }
 | 
						|
 | 
						|
bdgPortTxAbrt OBJECT-TYPE
 | 
						|
SYNTAX Counter
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The number of transmissions that have been aborted due to
 | 
						|
        excessive collisions (over 16 attempts to transmit the same
 | 
						|
        packet)."
 | 
						|
::= { bdgPort 13 }
 | 
						|
 | 
						|
bdgPortOowColl OBJECT-TYPE
 | 
						|
SYNTAX Counter
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The number of collisions out of the standard collision window
 | 
						|
        (51.2 uS). This indicates a network problem."
 | 
						|
::= { bdgPort 14 }
 | 
						|
 | 
						|
bdgPortCRCErr OBJECT-TYPE
 | 
						|
SYNTAX Counter
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The number of packets detected with Cyclical Redundancy Check
 | 
						|
        failures."
 | 
						|
::= { bdgPort 15 }
 | 
						|
 | 
						|
bdgPortFrAlErr OBJECT-TYPE
 | 
						|
SYNTAX Counter
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The number of errors due to misaligned packets."
 | 
						|
::= { bdgPort 16 }
 | 
						|
 | 
						|
bdgPortPriority OBJECT-TYPE
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-write
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The part of the port identifier which is used with the spanning
 | 
						|
        tree algorithm when determining which port in a LAN segment has
 | 
						|
        priority. The default is 80."
 | 
						|
::= { bdgPort 17 }
 | 
						|
 | 
						|
bdgPortState OBJECT-TYPE
 | 
						|
SYNTAX OCTET STRING
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The current state of the port, DISABLED, LISTENING, LEARNING,
 | 
						|
        FORWARDING or BLOCKING."
 | 
						|
::= { bdgPort 18 }
 | 
						|
 | 
						|
bdgPortPathCost OBJECT-TYPE
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-write
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The contributory cost of the applicable port to the overall cost
 | 
						|
        of the path when the specified port is the root port. Allowable
 | 
						|
        range is 1 to 65535. The default is 100."
 | 
						|
::= { bdgPort 19 }
 | 
						|
 | 
						|
bdgPortDesigCost OBJECT-TYPE
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The cost of the path of this port to the root bridge on the
 | 
						|
        network."
 | 
						|
::= { bdgPort 20 }
 | 
						|
 | 
						|
bdgPortDesigBrdg OBJECT-TYPE
 | 
						|
SYNTAX OCTET STRING
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The network address of the bridge that is assumed to be the root
 | 
						|
        bridge on the network."
 | 
						|
::= { bdgPort 21 }
 | 
						|
 | 
						|
bdgPortDesigPort OBJECT-TYPE
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The port identifier of the bridge port believed to be the
 | 
						|
        designated port for the LAN associated with the port."
 | 
						|
::= { bdgPort 22 }
 | 
						|
 | 
						|
bdgPortTopChgAck OBJECT-TYPE
 | 
						|
SYNTAX INTEGER 
 | 
						|
        {
 | 
						|
                noTopologyChangeIsOccurring (0),
 | 
						|
                topologyChangeIsOccurring   (1)
 | 
						|
        }
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The value of the topology change acknowledgement flag in the
 | 
						|
        next configuration BPDU to be transmitted on the associated port."
 | 
						|
::= { bdgPort 23 }
 | 
						|
 | 
						|
bdgPortDesigRoot OBJECT-TYPE
 | 
						|
SYNTAX OCTET STRING
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The unique bridge identifier of the bridge that is assumed to be
 | 
						|
        the root bridge on the network."
 | 
						|
::= { bdgPort 24 }
 | 
						|
 | 
						|
bdgPortRuntPackets OBJECT-TYPE
 | 
						|
SYNTAX Counter
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The number of packets received at the indicated bdgPort that were
 | 
						|
        less than the IEEE 802.3 minimum Ethernet frame size of 64 bytes."
 | 
						|
::= { bdgPort 25 }
 | 
						|
 | 
						|
bdgPortOversizePackets OBJECT-TYPE
 | 
						|
SYNTAX Counter
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The number of packets received at the indicated port that were
 | 
						|
        greater than the IEEE 802.3 maximum Ethernet frame size of 1518
 | 
						|
        bytes."
 | 
						|
::= { bdgPort 26 }
 | 
						|
 | 
						|
bdgPortFrFilt OBJECT-TYPE
 | 
						|
SYNTAX Counter
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The number of frames received at the indicated port that were
 | 
						|
        filtered by the bridge."
 | 
						|
::= { bdgPort 27 }
 | 
						|
 | 
						|
 | 
						|
-- Acquired Database Statistical Object Definitions
 | 
						|
--
 | 
						|
--      This section defines the objects under the Acquired Database
 | 
						|
--      Statistics node.
 | 
						|
--
 | 
						|
-- Instance Identifiers for Acquired Database Statistical Objects
 | 
						|
--
 | 
						|
--      There is only one instance of an Acquired Database Statistical object,
 | 
						|
--      thus the Instance Identifier is 0.
 | 
						|
--
 | 
						|
--  Acquired Database Statistical Objects
 | 
						|
 | 
						|
 | 
						|
acqTotalEntries OBJECT-TYPE
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The total number of entries in the acquired database."
 | 
						|
::= { acqStats 1 }
 | 
						|
 | 
						|
acqMaxEntries OBJECT-TYPE
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The maximum number of entries allowed in the acquired database."
 | 
						|
::= { acqStats 2 }
 | 
						|
 | 
						|
acqStaticEntries OBJECT-TYPE
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS  read-only
 | 
						|
STATUS  mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The number of addresses added to the Acquired database by the
 | 
						|
        user or network manager."
 | 
						|
::= { acqStats 3 }
 | 
						|
 | 
						|
acqStaticAgeTime OBJECT-TYPE
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The length of time allowed for a static entry in the Acquired
 | 
						|
        database to be inactive before it is dropped from the database.
 | 
						|
        This time is fixed at zero."
 | 
						|
::= { acqStats 4 }
 | 
						|
 | 
						|
acqDynEntries OBJECT-TYPE
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The number of entries that have been accumulated in the Acquired
 | 
						|
        database through the bridge's learning process."
 | 
						|
::= { acqStats 5 }
 | 
						|
 | 
						|
acqDynAgeTime OBJECT-TYPE
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-write
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The length of time allowed for a dynamic entry in the acquired
 | 
						|
        database to be inactive before it is dropped from the database. A
 | 
						|
        time from 10 - 1,000,000 seconds is allowed. The default is 300
 | 
						|
        seconds."
 | 
						|
::= { acqStats 6 }
 | 
						|
 | 
						|
acqEraseDatabase OBJECT-TYPE
 | 
						|
SYNTAX INTEGER 
 | 
						|
        {
 | 
						|
                eraseAcquiredDatabase (0)
 | 
						|
        }
 | 
						|
ACCESS read-write
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "Set to zero to erase all entries in the acquired database."
 | 
						|
::= { acqStats 7 }
 | 
						|
 | 
						|
 | 
						|
-- Acquired Database Option Object Definitions
 | 
						|
--
 | 
						|
--      This section defines the objects under the Acquired Database
 | 
						|
--      Option node.
 | 
						|
--
 | 
						|
-- Instance Identifiers for Acquired Database Option Objects
 | 
						|
--
 | 
						|
--      The instance identifier for the acquired database option objects is
 | 
						|
--      the 6-byte Ethernet address of the device to be added, deleted or
 | 
						|
--      displayed to/from the acquired database.
 | 
						|
--
 | 
						|
--  Acquired Database Option Objects
 | 
						|
 | 
						|
 | 
						|
acqCreate00 OBJECT-TYPE
 | 
						|
SYNTAX INTEGER 
 | 
						|
        {
 | 
						|
                createAcquiredEntryFilterPort1FilterPort2  (0)
 | 
						|
        }
 | 
						|
ACCESS read-write
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "Add an entry to the acquired database to filter packets entering
 | 
						|
        ports 1 and 2 if those packets are destined for the specified
 | 
						|
        address."
 | 
						|
::= { acqOptions 1 }
 | 
						|
 | 
						|
acqCreate20 OBJECT-TYPE
 | 
						|
SYNTAX INTEGER 
 | 
						|
        {
 | 
						|
                createAcquiredEntryForwardPort1FilterPort2  (0)
 | 
						|
        }
 | 
						|
ACCESS read-write
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "Add an entry to the acquired database to forward packets
 | 
						|
        entering port1 to port2 and filter packets entering port2 if
 | 
						|
        those packets are destined for the specified address."
 | 
						|
::= { acqOptions 2 }
 | 
						|
 | 
						|
acqCreate01 OBJECT-TYPE
 | 
						|
SYNTAX INTEGER 
 | 
						|
        {
 | 
						|
                createAcquiredEntryFilterPort1ForwardPort2  (0)
 | 
						|
        }
 | 
						|
ACCESS read-write
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "Add an entry to the acquired database to filter packets entering
 | 
						|
        port 1 and forward packets entering port 2 to port 1 if those
 | 
						|
        packets are destined for the specified address."
 | 
						|
::= { acqOptions 3 }
 | 
						|
 | 
						|
acqCreate21 OBJECT-TYPE
 | 
						|
SYNTAX INTEGER 
 | 
						|
        {
 | 
						|
                createAcquiredEntryForwardPort1ForwardPort2 (0)
 | 
						|
        }
 | 
						|
ACCESS read-write
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "Add an entry to the acquired database to forward packets
 | 
						|
        entering port 1 to port 2 and to forward packets entering port 2
 | 
						|
        to port 1 if those packets are destined for the specified
 | 
						|
        address."
 | 
						|
::= { acqOptions 4 }
 | 
						|
 | 
						|
acqDelete OBJECT-TYPE
 | 
						|
SYNTAX INTEGER 
 | 
						|
        {
 | 
						|
                deleteAcquiredEntry (0)
 | 
						|
        }
 | 
						|
ACCESS read-write
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "Delete an entry from the acquired database."
 | 
						|
::= { acqOptions 5 }
 | 
						|
 | 
						|
acqDispType OBJECT-TYPE
 | 
						|
SYNTAX OCTET STRING
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "Display the entry type, STATIC or DYNAMIC."
 | 
						|
::= { acqOptions 6 }
 | 
						|
 | 
						|
acqDispOutp1 OBJECT-TYPE
 | 
						|
SYNTAX INTEGER 
 | 
						|
        {
 | 
						|
                filter (0),
 | 
						|
                relay  (2)
 | 
						|
        }
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The outbound port for packets entering port 1."
 | 
						|
::= { acqOptions 7 }
 | 
						|
 | 
						|
acqDispOutp2 OBJECT-TYPE
 | 
						|
SYNTAX INTEGER 
 | 
						|
        {
 | 
						|
                filter (0),
 | 
						|
                relay  (1)
 | 
						|
        }
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The outbound port for packets entering port 2."
 | 
						|
::= { acqOptions 8 }
 | 
						|
 | 
						|
acqSrcAddress OBJECT-TYPE
 | 
						|
SYNTAX OCTET STRING
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The source address of this acquired database entry, i.e. the
 | 
						|
        instance."
 | 
						|
::= { acqOptions 9 }
 | 
						|
 | 
						|
-- Permanent Database Statistical Object Definitions
 | 
						|
--
 | 
						|
--      This section defines the objects under the Permanent Database
 | 
						|
--      Statistics node.
 | 
						|
--
 | 
						|
-- Instance Identifiers for Permanent Database Statistical Objects
 | 
						|
--
 | 
						|
--      There is only one instance of an Permanent Database Statistical
 | 
						|
--      object, thus the Instance Identifier is 0.
 | 
						|
--
 | 
						|
--  Permanent Database Statistical Objects
 | 
						|
 | 
						|
 | 
						|
permMaxEntries OBJECT-TYPE
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The maximum number of entries allowed in the permanent database."
 | 
						|
::= { permStats 1 }
 | 
						|
 | 
						|
permCurrEntries OBJECT-TYPE
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The number of entries currently recorded in the bridge's
 | 
						|
        permanent database."
 | 
						|
::= { permStats 2 }
 | 
						|
 | 
						|
permEraseDatabase OBJECT-TYPE
 | 
						|
SYNTAX INTEGER 
 | 
						|
        {
 | 
						|
                erasePermanentDatabase (0)
 | 
						|
        }
 | 
						|
ACCESS read-write
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "Erase all entries in the permanent database."
 | 
						|
::= { permStats 3 }
 | 
						|
 | 
						|
-- Permanent Database Option Object Definitions
 | 
						|
--
 | 
						|
--      This section defines the objects under the Permanent Database
 | 
						|
--      Option node.
 | 
						|
--
 | 
						|
-- Instance Identifiers for Permanent Database Option Objects
 | 
						|
--
 | 
						|
--      The instance identifier for the permanent database option objects is
 | 
						|
--      the 6-byte Ethernet address of the device to be added, deleted or
 | 
						|
--      displayed to/from the permanent database.
 | 
						|
--
 | 
						|
--  Permanent Database Option Objects
 | 
						|
 | 
						|
permCreate00 OBJECT-TYPE
 | 
						|
SYNTAX INTEGER 
 | 
						|
        {
 | 
						|
                createPermanentEntryFilterPort1FilterPort2 (0)
 | 
						|
        }
 | 
						|
ACCESS read-write
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "Add an entry to the permanent database to filter packets
 | 
						|
        entering ports 1 and 2 if those packets are destined for the
 | 
						|
        specified address."
 | 
						|
::= { permOptions 1 }
 | 
						|
 | 
						|
permCreate20 OBJECT-TYPE
 | 
						|
SYNTAX INTEGER 
 | 
						|
        {
 | 
						|
                createPermanentEntryForwardPort1FilterPort2 (0)
 | 
						|
        }
 | 
						|
ACCESS read-write
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "Add an entry to the permanent database to forward packets
 | 
						|
        entering port 1 and filter packets entering port 2 if those
 | 
						|
        packets are destined for the specified address."
 | 
						|
::= { permOptions 2 }
 | 
						|
 | 
						|
permCreate01 OBJECT-TYPE
 | 
						|
SYNTAX INTEGER 
 | 
						|
        {
 | 
						|
                createPermanentEntryFilterPort1ForwardPort2 (0)
 | 
						|
        }
 | 
						|
ACCESS read-write
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "Add an entry to the permanent database to filter packets
 | 
						|
        entering port 1 and forward packets entering port 2 if those
 | 
						|
        packets are destined for the specified address."
 | 
						|
::= { permOptions 3 }
 | 
						|
 | 
						|
permCreate21 OBJECT-TYPE
 | 
						|
SYNTAX INTEGER
 | 
						|
        {
 | 
						|
                createPermanentEntryForwardPort1ForwardPort2 (0)
 | 
						|
        }
 | 
						|
ACCESS read-write
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "Add an entry to the permanent database to forward packets
 | 
						|
        entering ports 1 and 2 if those packets are destined for the
 | 
						|
        specified address."
 | 
						|
::= { permOptions 4 }
 | 
						|
 | 
						|
permDelete OBJECT-TYPE
 | 
						|
SYNTAX INTEGER 
 | 
						|
        {
 | 
						|
                deletePermanentEntry (0)
 | 
						|
        }
 | 
						|
ACCESS read-write
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "Delete an entry from the permanent database."
 | 
						|
::= { permOptions 5 }
 | 
						|
 | 
						|
permDispType OBJECT-TYPE
 | 
						|
SYNTAX OCTET STRING
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "Display the entry type, STATIC or DYNAMIC."
 | 
						|
::= { permOptions 6 }
 | 
						|
 | 
						|
permDispOutp1 OBJECT-TYPE
 | 
						|
SYNTAX INTEGER 
 | 
						|
        {
 | 
						|
                filter (0),
 | 
						|
                relay  (2)
 | 
						|
        }
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The outbound port for packets entering port 1."
 | 
						|
::= { permOptions 7 }
 | 
						|
 | 
						|
permDispOutp2 OBJECT-TYPE
 | 
						|
SYNTAX INTEGER 
 | 
						|
        {
 | 
						|
                filter (0),
 | 
						|
                relay  (1)
 | 
						|
        }
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The outbound port for packets entering port 2."
 | 
						|
::= { permOptions 8 }
 | 
						|
 | 
						|
permSrcAddress OBJECT-TYPE
 | 
						|
SYNTAX OCTET STRING
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The source address in this permanent database entry, i.e. the
 | 
						|
        instance."
 | 
						|
::= { permOptions 9 }
 | 
						|
 | 
						|
-- Special Database Statistical Object Definitions
 | 
						|
--
 | 
						|
--      This section defines the objects under the Special Database
 | 
						|
--      Statistical node.
 | 
						|
--
 | 
						|
-- Instance Identifiers for Special Database Statistical Objects
 | 
						|
--
 | 
						|
--      There is only one instance of a Special Database Statistical object,
 | 
						|
--      thus the Instance Identifier is 0.
 | 
						|
--
 | 
						|
-- Special Database Statistical Objects
 | 
						|
 | 
						|
specNumEntries OBJECT-TYPE
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The number of filters in the special database."
 | 
						|
::= { specStats 1 }
 | 
						|
 | 
						|
specMaxEntries OBJECT-TYPE
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The maximum number of filters the special database can contain."
 | 
						|
::= { specStats 2 }
 | 
						|
 | 
						|
specNextFilterNum OBJECT-TYPE
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "The number of the next available filter that can be added to the
 | 
						|
        special database."
 | 
						|
::= { specStats 3 }
 | 
						|
 | 
						|
-- Special Database Filter Object Definitions
 | 
						|
--
 | 
						|
--      This section defines the objects under the Special Database
 | 
						|
--      Filter node.
 | 
						|
--
 | 
						|
-- Instance Identifiers for Special Database Filter Objects
 | 
						|
--
 | 
						|
--      The instance identifier of the special database filter objects
 | 
						|
--      is the filter number, values from 1 through 10 are allowed.
 | 
						|
--
 | 
						|
-- Special Database Filter Objects
 | 
						|
 | 
						|
specEnable OBJECT-TYPE
 | 
						|
SYNTAX INTEGER 
 | 
						|
        {
 | 
						|
                disableFilter (0),
 | 
						|
                enableFilter  (1)
 | 
						|
        }
 | 
						|
ACCESS read-write
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "Enable or disable the filter."
 | 
						|
::= { specFilters 1 }
 | 
						|
 | 
						|
specPort1 OBJECT-TYPE
 | 
						|
SYNTAX INTEGER 
 | 
						|
        {
 | 
						|
                filter (0),
 | 
						|
                relay  (2)
 | 
						|
        }
 | 
						|
ACCESS read-write
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "Set port 1 to filter or forward packets."
 | 
						|
::= { specFilters 2 }
 | 
						|
 | 
						|
specPort2 OBJECT-TYPE
 | 
						|
SYNTAX INTEGER 
 | 
						|
        {
 | 
						|
                filter (0),
 | 
						|
                relay  (1)
 | 
						|
        }
 | 
						|
ACCESS read-write
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "Set port 2 to filter or forward packets."
 | 
						|
::= { specFilters 3 }
 | 
						|
 | 
						|
specDestAddress OBJECT-TYPE
 | 
						|
SYNTAX OCTET STRING
 | 
						|
ACCESS read-write
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "Set the special database to filter packets with a specific
 | 
						|
        destination address."
 | 
						|
::= { specFilters 4 }
 | 
						|
 | 
						|
specSrcAddress OBJECT-TYPE
 | 
						|
SYNTAX OCTET STRING
 | 
						|
ACCESS read-write
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "Set the special database to filter packets with a specific
 | 
						|
        source address."
 | 
						|
::= { specFilters 5 }
 | 
						|
 | 
						|
specType OBJECT-TYPE
 | 
						|
SYNTAX OCTET STRING
 | 
						|
ACCESS read-write
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "Set the special database to filter packets with a specific type
 | 
						|
        field."
 | 
						|
::= { specFilters 6 }
 | 
						|
 | 
						|
specDataField OBJECT-TYPE
 | 
						|
SYNTAX OCTET STRING
 | 
						|
ACCESS read-write
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "Set the special database to filter packets based on the first
 | 
						|
        sixteen bytes of data in the packet."
 | 
						|
::= { specFilters 7 }
 | 
						|
 | 
						|
specDeleteFilter OBJECT-TYPE
 | 
						|
SYNTAX INTEGER 
 | 
						|
        {
 | 
						|
                deleteFilter (0)
 | 
						|
        }
 | 
						|
ACCESS read-write
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
        "Delete a filter from the special database."
 | 
						|
::= { specFilters 8 }
 | 
						|
 | 
						|
 | 
						|
-- TRAP TYPES OBJECT DEFINITIONS
 | 
						|
--
 | 
						|
-- This section describes the trap types that the bridge can generate. These
 | 
						|
-- are not objects, but Object Identifiers used to indicate the specific trap.
 | 
						|
-- They are taken from the object space and are thus documented here.
 | 
						|
--
 | 
						|
-- The SNMP trap messages are composed of two user definable areas: 
 | 
						|
--     a) the specific trap type and 
 | 
						|
--     b) the VarBindings (e.g. the interesting information)
 | 
						|
--
 | 
						|
-- The specific trap type is an integer that is used to determine the
 | 
						|
-- specific trap which has occurred. The "interesting information" contains
 | 
						|
-- a group of object identifiers and their values that provide information
 | 
						|
-- about the trap.
 | 
						|
--
 | 
						|
-- Trap Decription
 | 
						|
--
 | 
						|
--      BridgeStatus
 | 
						|
--
 | 
						|
--      Specific Trap Type Code - 0x0301
 | 
						|
--
 | 
						|
--      When the bridge status changes, a trap will be generated. The
 | 
						|
--   interesting information includes the current status of the bridge.
 | 
						|
--
 | 
						|
--
 | 
						|
-- Trap Description
 | 
						|
--
 | 
						|
--      AcqDbaseFull
 | 
						|
--
 | 
						|
--      Specific Trap Type Code - 0x0302
 | 
						|
--
 | 
						|
--      When the acquired portion of the bridge's filtering database is full, a
 | 
						|
--   trap is generated. The interesting information included with this trap
 | 
						|
--   is the number of entries in the acquired database.
 | 
						|
          
 | 
						|
-- Formal definition of the Layer Management MIB. (e.g. PC cards )
 | 
						|
 | 
						|
     lmcommon         OBJECT IDENTIFIER ::= { layerMgmt 1 }
 | 
						|
          
 | 
						|
     mAC            OBJECT IDENTIFIER ::= { layerMgmt 2 }          
 | 
						|
 | 
						|
     ieee8023      OBJECT IDENTIFIER ::= {  mAC 1 }
 | 
						|
          
 | 
						|
     pcIF           OBJECT IDENTIFIER ::= { ieee8023 1 }
 | 
						|
 | 
						|
     pcIfRev        OBJECT IDENTIFIER ::= { pcIF 1 }
 | 
						|
 | 
						|
          
 | 
						|
                        
 | 
						|
pcDeviceName OBJECT-TYPE   
 | 
						|
          
 | 
						|
SYNTAX OCTET STRING
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
    "Name of the PC device"
 | 
						|
::= { pcIfRev 1 }
 | 
						|
 | 
						|
 | 
						|
pcBoardType   OBJECT-TYPE
 | 
						|
 | 
						|
SYNTAX OBJECT IDENTIFIER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
     "An object  Identifier that  indicates the  type of  the  PC
 | 
						|
     board. This will include MAC type and Media type."
 | 
						|
 | 
						|
 | 
						|
::= { pcIfRev 2  }
 | 
						|
 | 
						|
pcOwnerName    OBJECT-TYPE
 | 
						|
 | 
						|
SYNTAX OCTET STRING
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
     "The owner of this PC."
 | 
						|
 | 
						|
 | 
						|
::= { pcIfRev 3 }
 | 
						|
 | 
						|
pcLocation    OBJECT-TYPE
 | 
						|
 | 
						|
SYNTAX OCTET STRING
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
     "A text description of the location of this PC."
 | 
						|
 | 
						|
::= { pcIfRev 4 }
 | 
						|
 | 
						|
pcMMACAddr    OBJECT-TYPE
 | 
						|
 | 
						|
SYNTAX OCTET STRING
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
     "The MAC address of the MMAC that this PC is connected to."
 | 
						|
 | 
						|
 | 
						|
::= { pcIfRev 5 }
 | 
						|
 | 
						|
pcMMACBoard    OBJECT-TYPE
 | 
						|
 | 
						|
SYNTAX OCTET STRING
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
     "The slot  number of  the board  in the MMAC that this PC is
 | 
						|
connected to."
 | 
						|
 | 
						|
 | 
						|
::= { pcIfRev 6  }
 | 
						|
 | 
						|
pcMMACPort    OBJECT-TYPE
 | 
						|
 | 
						|
SYNTAX OCTET STRING
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
     "The number  of the  port on the board of the MMAC that this
 | 
						|
PC is connected to."
 | 
						|
::= { pcIfRev 7 }
 | 
						|
 | 
						|
pcApplication    OBJECT-TYPE
 | 
						|
 | 
						|
SYNTAX OCTET STRING
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
     "A text  description of  the network  application running on
 | 
						|
this PC."
 | 
						|
 | 
						|
 | 
						|
::= { pcIfRev 8 }
 | 
						|
 | 
						|
pcDriverRev    OBJECT-TYPE
 | 
						|
 | 
						|
SYNTAX OCTET STRING
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
     "The revision of the LAN card driver."
 | 
						|
::= { pcIfRev 9 }
 | 
						|
 | 
						|
pcOnboardMemory    OBJECT-TYPE
 | 
						|
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
     "The number  of Kilobytes  of memory  (eg. a 16K board would
 | 
						|
reply 16)"
 | 
						|
 | 
						|
::= { pcIfRev 10 }
 | 
						|
 | 
						|
pcComment    OBJECT-TYPE
 | 
						|
 | 
						|
SYNTAX OCTET STRING
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
     "A user-defined character string."
 | 
						|
 | 
						|
 | 
						|
::= { pcIfRev 11 }
 | 
						|
 
 | 
						|
pcMACAddr   OBJECT-TYPE
 | 
						|
 | 
						|
SYNTAX OCTET STRING
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
     "The MAC address of the PC card."
 | 
						|
 | 
						|
 | 
						|
::= { pcIfRev 12  }
 | 
						|
 | 
						|
pcFramesXmit   OBJECT-TYPE
 | 
						|
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
     "The number of MAC frames transmitted by this PC card."
 | 
						|
 | 
						|
 | 
						|
::= { pcIfRev 13  }
 | 
						|
 | 
						|
pcBytesXmit    OBJECT-TYPE
 | 
						|
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
     "The number bytes transmitted by this PC card."
 | 
						|
 | 
						|
 | 
						|
::= { pcIfRev 14 }
 | 
						|
 | 
						|
pcMcastXmit    OBJECT-TYPE
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
     "The number of multicasted frames sent by this PC card."
 | 
						|
 | 
						|
::= { pcIfRev 15 }
 | 
						|
 | 
						|
pcBcastXmit    OBJECT-TYPE
 | 
						|
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
     "The number of broadcast frames from this PC card."
 | 
						|
 | 
						|
 | 
						|
::= { pcIfRev 16 }
 | 
						|
 | 
						|
pcDeferXmit    OBJECT-TYPE
 | 
						|
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
     "The number  of transmit  packets that  were deferred due to
 | 
						|
busy media."
 | 
						|
 | 
						|
::= { pcIfRev 17 }
 | 
						|
 | 
						|
pcSglColl     OBJECT-TYPE
 | 
						|
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
     "The  number   of  transmit  packet  experiencing  a  single
 | 
						|
collision."
 | 
						|
 | 
						|
::= { pcIfRev 18 }
 | 
						|
 | 
						|
pcMultiColl    OBJECT-TYPE
 | 
						|
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
     "The  number  of  transmit  packets  that  have  experienced
 | 
						|
multiple collisions."
 | 
						|
 | 
						|
::= { pcIfRev 19 }
 | 
						|
 | 
						|
pcTotXmitErrs    OBJECT-TYPE
 | 
						|
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
     "The total number of transmit errors."
 | 
						|
 | 
						|
::= { pcIfRev 20 }
 | 
						|
 | 
						|
pcLateColls   OBJECT-TYPE
 | 
						|
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
     "The  number  of  transmit  packets  that  experienced  late
 | 
						|
collisions."
 | 
						|
 | 
						|
 | 
						|
::= { pcIfRev 21 }
 | 
						|
 | 
						|
pcXcessColls    OBJECT-TYPE
 | 
						|
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
     "The number  of  transmit  packets  aborted  due  to  excess
 | 
						|
collisions."
 | 
						|
 | 
						|
::= { pcIfRev 22 }
 | 
						|
 | 
						|
pcCarrErr   OBJECT-TYPE
 | 
						|
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
     "The number  of transmit  packets  that  experience  carrier
 | 
						|
sense errors (ie. lose carrier during transmission)."
 | 
						|
 | 
						|
::= { pcIfRev 23 }
 | 
						|
 | 
						|
pcFramesRec   OBJECT-TYPE
 | 
						|
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
     "The number of frames received."
 | 
						|
 | 
						|
::= { pcIfRev 24 }
 | 
						|
 | 
						|
pcBytesRec    OBJECT-TYPE
 | 
						|
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
     "The number of bytes received by this station."
 | 
						|
 | 
						|
 | 
						|
::= { pcIfRev 25 }
 | 
						|
 | 
						|
pcMcastRec    OBJECT-TYPE
 | 
						|
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
     "The number of multicasted frames received."
 | 
						|
 | 
						|
::= { pcIfRev 26 }
 | 
						|
 | 
						|
pcBcastRec    OBJECT-TYPE
 | 
						|
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
     "The number of broadcast packets received."
 | 
						|
 | 
						|
::= { pcIfRev 27 }
 | 
						|
 | 
						|
pcTotRecErrs    OBJECT-TYPE
 | 
						|
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
     "The total number of receive errors."
 | 
						|
 | 
						|
::= { pcIfRev 28 }
 | 
						|
 | 
						|
pcTooLong   OBJECT-TYPE
 | 
						|
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
     "The number of packets received that are too long (over 1518
 | 
						|
bytes)."
 | 
						|
 | 
						|
::= { pcIfRev 29 }
 | 
						|
 | 
						|
pcTooShort    OBJECT-TYPE
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
     "The number  of packets  that are too short. (under 64 bytes
 | 
						|
long)."
 | 
						|
 | 
						|
::= { pcIfRev 30 }
 | 
						|
 | 
						|
pcAlignErrs    OBJECT-TYPE
 | 
						|
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
     "The number of alignment errors in receive packets."
 | 
						|
 | 
						|
 | 
						|
::= { pcIfRev 31 }
 | 
						|
 | 
						|
pcCRCErrs     OBJECT-TYPE
 | 
						|
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
     "The number of receive packets with CRC errors."
 | 
						|
 | 
						|
::= { pcIfRev 32  }
 | 
						|
 | 
						|
pcLenErrs    OBJECT-TYPE
 | 
						|
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
     "The number  of packets  whose length  is not  equal to  the
 | 
						|
number of bytes received."
 | 
						|
 | 
						|
::= { pcIfRev 33 }
 | 
						|
 | 
						|
pcIntRecErr    OBJECT-TYPE
 | 
						|
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
     "The number  of receive  packets that  experienced  internal
 | 
						|
errors (eg. no receive buffers)."
 | 
						|
 | 
						|
::= { pcIfRev 34 }
 | 
						|
 | 
						|
pcSqeErr    OBJECT-TYPE
 | 
						|
 | 
						|
SYNTAX INTEGER
 | 
						|
ACCESS read-only
 | 
						|
STATUS mandatory
 | 
						|
DESCRIPTION
 | 
						|
     "The number of SQE errors."
 | 
						|
 | 
						|
::= { pcIfRev 35 }
 | 
						|
 | 
						|
END
 |