mirror of
				https://github.com/librenms/librenms.git
				synced 2024-10-07 16:52:45 +00:00 
			
		
		
		
	git-svn-id: http://www.observium.org/svn/observer/trunk@1645 61d68cd4-352d-0410-923a-c4978735b2b8
		
			
				
	
	
		
			630 lines
		
	
	
		
			21 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
			
		
		
	
	
			630 lines
		
	
	
		
			21 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
-- *****************************************************************
 | 
						|
-- POWER-ETHERNET-MIB
 | 
						|
--
 | 
						|
-- This mib was extracted from RFC 3621
 | 
						|
--
 | 
						|
-- Copyright (c) 2006, 2009 by Cisco Systems, Inc.
 | 
						|
-- All rights reserved.
 | 
						|
-- *****************************************************************
 | 
						|
POWER-ETHERNET-MIB DEFINITIONS ::= BEGIN
 | 
						|
 | 
						|
IMPORTS
 | 
						|
           MODULE-IDENTITY, mib-2, OBJECT-TYPE, Integer32,
 | 
						|
           Gauge32, Counter32, NOTIFICATION-TYPE
 | 
						|
                   FROM SNMPv2-SMI
 | 
						|
           TruthValue
 | 
						|
                   FROM SNMPv2-TC
 | 
						|
           MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
 | 
						|
                   FROM SNMPv2-CONF
 | 
						|
 | 
						|
            SnmpAdminString
 | 
						|
                    FROM SNMP-FRAMEWORK-MIB;
 | 
						|
 | 
						|
    powerEthernetMIB MODULE-IDENTITY
 | 
						|
 | 
						|
         LAST-UPDATED    "200311240000Z"  -- November 24, 2003
 | 
						|
         ORGANIZATION "IETF Ethernet Interfaces and Hub MIB
 | 
						|
                       Working Group"
 | 
						|
 | 
						|
         CONTACT-INFO
 | 
						|
         "
 | 
						|
          WG Charter:
 | 
						|
          http://www.ietf.org/html.charters/hubmib-charter.html
 | 
						|
 | 
						|
         Mailing lists:
 | 
						|
          General Discussion: hubmib@ietf.org
 | 
						|
          To Subscribe: hubmib-requests@ietf.org
 | 
						|
          In Body: subscribe your_email_address
 | 
						|
 | 
						|
         Chair: Dan Romascanu
 | 
						|
          Avaya
 | 
						|
          Tel:  +972-3-645-8414
 | 
						|
          Email: dromasca@avaya.com
 | 
						|
 | 
						|
         Editor: Avi Berger
 | 
						|
          PowerDsine Inc.
 | 
						|
          Tel:    972-9-7755100 Ext 307
 | 
						|
          Fax:    972-9-7755120
 | 
						|
          E-mail: avib@PowerDsine.com
 | 
						|
         "
 | 
						|
 | 
						|
        DESCRIPTION
 | 
						|
              "The MIB module for managing Power Source Equipment
 | 
						|
               (PSE) working according to the IEEE 802.af Powered
 | 
						|
               Ethernet (DTE Power via MDI) standard.
 | 
						|
 | 
						|
                The following terms are used throughout this
 | 
						|
                MIB module.  For complete formal definitions,
 | 
						|
                the IEEE 802.3 standards should be consulted
 | 
						|
                wherever possible:
 | 
						|
 | 
						|
                Group - A recommended, but optional, entity
 | 
						|
                defined by the IEEE 802.3 management standard,
 | 
						|
                in order to support a modular numbering scheme.
 | 
						|
                The classical example allows an implementor to
 | 
						|
                represent field-replaceable units as groups of
 | 
						|
                ports, with the port numbering matching the
 | 
						|
                modular hardware implementation.
 | 
						|
 | 
						|
              Port - This entity identifies the port within the group
 | 
						|
              for which this entry contains information.  The numbering
 | 
						|
              scheme for ports is implementation specific.
 | 
						|
 | 
						|
             Copyright (c) The Internet Society (2003).  This version
 | 
						|
             of this MIB module is part of RFC 3621; See the RFC
 | 
						|
             itself for full legal notices."
 | 
						|
 | 
						|
       REVISION    "200311240000Z"  -- November 24, 2003
 | 
						|
       DESCRIPTION "Initial version, published as RFC 3621."
 | 
						|
       ::= { mib-2 105 }
 | 
						|
 | 
						|
pethNotifications OBJECT IDENTIFIER ::= { powerEthernetMIB 0 }
 | 
						|
pethObjects       OBJECT IDENTIFIER ::= { powerEthernetMIB 1 }
 | 
						|
pethConformance   OBJECT IDENTIFIER ::= { powerEthernetMIB 2 }
 | 
						|
 | 
						|
-- PSE Objects
 | 
						|
 | 
						|
  pethPsePortTable OBJECT-TYPE
 | 
						|
       SYNTAX      SEQUENCE OF PethPsePortEntry
 | 
						|
       MAX-ACCESS  not-accessible
 | 
						|
       STATUS      current
 | 
						|
       DESCRIPTION
 | 
						|
           "A table of objects that display and control the power
 | 
						|
            characteristics of power Ethernet ports on a Power Source
 | 
						|
            Entity (PSE) device.  This group will be implemented in
 | 
						|
            managed power Ethernet switches and mid-span devices.
 | 
						|
            Values of all read-write objects in this table are
 | 
						|
            persistent at restart/reboot."
 | 
						|
       ::= { pethObjects 1 }
 | 
						|
 | 
						|
   pethPsePortEntry OBJECT-TYPE
 | 
						|
       SYNTAX      PethPsePortEntry
 | 
						|
       MAX-ACCESS  not-accessible
 | 
						|
       STATUS      current
 | 
						|
       DESCRIPTION
 | 
						|
               "A set of objects that display and control the power
 | 
						|
               characteristics of a power Ethernet PSE port."
 | 
						|
       INDEX    { pethPsePortGroupIndex , pethPsePortIndex  }
 | 
						|
       ::= { pethPsePortTable 1 }
 | 
						|
 | 
						|
   PethPsePortEntry ::= SEQUENCE {
 | 
						|
       pethPsePortGroupIndex
 | 
						|
          Integer32,
 | 
						|
       pethPsePortIndex
 | 
						|
          Integer32,
 | 
						|
       pethPsePortAdminEnable
 | 
						|
          TruthValue,
 | 
						|
       pethPsePortPowerPairsControlAbility
 | 
						|
          TruthValue,
 | 
						|
       pethPsePortPowerPairs
 | 
						|
          INTEGER,
 | 
						|
       pethPsePortDetectionStatus
 | 
						|
          INTEGER,
 | 
						|
       pethPsePortPowerPriority
 | 
						|
          INTEGER,
 | 
						|
       pethPsePortMPSAbsentCounter
 | 
						|
          Counter32,
 | 
						|
       pethPsePortType
 | 
						|
          SnmpAdminString,
 | 
						|
       pethPsePortPowerClassifications
 | 
						|
          INTEGER,
 | 
						|
       pethPsePortInvalidSignatureCounter
 | 
						|
          Counter32,
 | 
						|
       pethPsePortPowerDeniedCounter
 | 
						|
          Counter32,
 | 
						|
       pethPsePortOverLoadCounter
 | 
						|
          Counter32,
 | 
						|
       pethPsePortShortCounter
 | 
						|
          Counter32
 | 
						|
  }
 | 
						|
 | 
						|
     pethPsePortGroupIndex OBJECT-TYPE
 | 
						|
       SYNTAX      Integer32 (1..2147483647)
 | 
						|
       MAX-ACCESS  not-accessible
 | 
						|
       STATUS      current
 | 
						|
       DESCRIPTION
 | 
						|
           "This variable uniquely identifies the group
 | 
						|
            containing the port to which a power Ethernet PSE is
 | 
						|
            connected.  Group means box in the stack, module in a
 | 
						|
            rack and the value 1 MUST be used for non-modular devices.
 | 
						|
            Furthermore, the same value MUST be used in this variable,
 | 
						|
            pethMainPseGroupIndex, and pethNotificationControlGroupIndex
 | 
						|
            to refer to a given box in a stack or module in the rack."
 | 
						|
       ::= { pethPsePortEntry 1 }
 | 
						|
 | 
						|
     pethPsePortIndex OBJECT-TYPE
 | 
						|
       SYNTAX      Integer32 (1..2147483647)
 | 
						|
       MAX-ACCESS  not-accessible
 | 
						|
       STATUS      current
 | 
						|
       DESCRIPTION
 | 
						|
           "This variable uniquely identifies the power Ethernet PSE
 | 
						|
            port within group pethPsePortGroupIndex to which the
 | 
						|
            power Ethernet PSE entry is connected."
 | 
						|
       ::= { pethPsePortEntry 2 }
 | 
						|
 | 
						|
     pethPsePortAdminEnable OBJECT-TYPE
 | 
						|
    SYNTAX TruthValue
 | 
						|
    MAX-ACCESS read-write
 | 
						|
    STATUS current
 | 
						|
    DESCRIPTION
 | 
						|
        "true (1) An interface which can provide the PSE functions.
 | 
						|
         false(2) The interface will act as it would if it had no PSE
 | 
						|
         function."
 | 
						|
    REFERENCE
 | 
						|
      "IEEE Std 802.3af Section 30.9.1.1.2 aPSEAdminState"
 | 
						|
    ::= { pethPsePortEntry 3 }
 | 
						|
 | 
						|
     pethPsePortPowerPairsControlAbility OBJECT-TYPE
 | 
						|
    SYNTAX TruthValue
 | 
						|
    MAX-ACCESS read-only
 | 
						|
    STATUS current
 | 
						|
    DESCRIPTION
 | 
						|
        "Describes the capability of controlling the power pairs
 | 
						|
         functionality to switch pins for sourcing power.
 | 
						|
         The value true indicate that the device has the capability
 | 
						|
         to control the power pairs.  When false the PSE Pinout
 | 
						|
         Alternative used cannot be controlled through the
 | 
						|
         PethPsePortAdminEnable attribute."
 | 
						|
    REFERENCE
 | 
						|
      "IEEE Std 802.3af Section 30.9.1.1.3
 | 
						|
       aPSEPowerPairsControlAbility"
 | 
						|
    ::= { pethPsePortEntry 4 }
 | 
						|
 | 
						|
    pethPsePortPowerPairs OBJECT-TYPE
 | 
						|
    SYNTAX INTEGER   {
 | 
						|
               signal(1),
 | 
						|
               spare(2)
 | 
						|
     }
 | 
						|
    MAX-ACCESS read-write
 | 
						|
    STATUS current
 | 
						|
    DESCRIPTION
 | 
						|
        "Describes or controls the pairs in use.  If the value of
 | 
						|
         pethPsePortPowerPairsControl is true, this object is
 | 
						|
         writable.
 | 
						|
         A value of signal(1) means that the signal pairs
 | 
						|
         only are in use.
 | 
						|
         A value of spare(2) means that the spare pairs
 | 
						|
         only are in use."
 | 
						|
    REFERENCE
 | 
						|
      "IEEE Std 802.3af Section 30.9.1.1.4 aPSEPowerPairs"
 | 
						|
    ::= { pethPsePortEntry 5 }
 | 
						|
 | 
						|
     pethPsePortDetectionStatus OBJECT-TYPE
 | 
						|
    SYNTAX INTEGER   {
 | 
						|
             disabled(1),
 | 
						|
             searching(2),
 | 
						|
               deliveringPower(3),
 | 
						|
               fault(4),
 | 
						|
               test(5),
 | 
						|
               otherFault(6)
 | 
						|
     }
 | 
						|
    MAX-ACCESS read-only
 | 
						|
    STATUS current
 | 
						|
    DESCRIPTION
 | 
						|
        "Describes the operational status of the port PD detection.
 | 
						|
         A value of disabled(1)- indicates that the PSE State diagram
 | 
						|
         is in the state DISABLED.
 | 
						|
         A value of deliveringPower(3) - indicates that the PSE State
 | 
						|
         diagram is in the state POWER_ON for a duration greater than
 | 
						|
         tlim max (see IEEE Std 802.3af Table 33-5 tlim).
 | 
						|
         A value of fault(4) - indicates that the PSE State diagram is
 | 
						|
         in the state TEST_ERROR.
 | 
						|
         A value of test(5) - indicates that the PSE State diagram is
 | 
						|
         in the state TEST_MODE.
 | 
						|
         A value of otherFault(6) - indicates that the PSE State
 | 
						|
         diagram is in the state IDLE due to the variable
 | 
						|
         error_conditions.
 | 
						|
         A value of searching(2)- indicates the PSE State diagram is
 | 
						|
         in a state other than those listed above."
 | 
						|
    REFERENCE
 | 
						|
      "IEEE Std 802.3af Section 30.9.1.1.5
 | 
						|
       aPSEPowerDetectionStatus"
 | 
						|
    ::= { pethPsePortEntry 6 }
 | 
						|
 | 
						|
     pethPsePortPowerPriority OBJECT-TYPE
 | 
						|
    SYNTAX INTEGER   {
 | 
						|
               critical(1),
 | 
						|
               high(2),
 | 
						|
               low(3)
 | 
						|
     }
 | 
						|
    MAX-ACCESS read-write
 | 
						|
    STATUS current
 | 
						|
    DESCRIPTION
 | 
						|
        "This object controls the priority of the port from the point
 | 
						|
         of view of a power management algorithm.  The priority that
 | 
						|
         is set by this variable could be used by a control mechanism
 | 
						|
         that prevents over current situations by disconnecting first
 | 
						|
         ports with lower power priority.  Ports that connect devices
 | 
						|
         critical to the operation of the network - like the E911
 | 
						|
         telephones ports - should be set to higher priority."
 | 
						|
    ::= { pethPsePortEntry 7 }
 | 
						|
 | 
						|
   pethPsePortMPSAbsentCounter OBJECT-TYPE
 | 
						|
    SYNTAX Counter32
 | 
						|
    MAX-ACCESS read-only
 | 
						|
    STATUS current
 | 
						|
    DESCRIPTION
 | 
						|
          "This counter is incremented when the PSE state diagram
 | 
						|
             transitions directly from the state POWER_ON to the
 | 
						|
             state IDLE due to tmpdo_timer_done being asserted."
 | 
						|
    REFERENCE
 | 
						|
      "IEEE Std 802.3af Section 30.9.1.1.11
 | 
						|
       aPSEMPSAbsentCounter"
 | 
						|
    ::= { pethPsePortEntry 8 }
 | 
						|
 | 
						|
   pethPsePortType OBJECT-TYPE
 | 
						|
    SYNTAX SnmpAdminString
 | 
						|
    MAX-ACCESS read-write
 | 
						|
    STATUS current
 | 
						|
    DESCRIPTION
 | 
						|
        "A manager will set the value of this variable to indicate
 | 
						|
         the type of powered device that is connected to the port.
 | 
						|
         The default value supplied by the agent if no value has
 | 
						|
         ever been set should be a zero-length octet string."
 | 
						|
    ::= { pethPsePortEntry 9 }
 | 
						|
 | 
						|
    pethPsePortPowerClassifications OBJECT-TYPE
 | 
						|
     SYNTAX INTEGER   {
 | 
						|
               class0(1),
 | 
						|
               class1(2),
 | 
						|
               class2(3),
 | 
						|
               class3(4),
 | 
						|
               class4(5)
 | 
						|
     }
 | 
						|
    MAX-ACCESS read-only
 | 
						|
    STATUS current
 | 
						|
    DESCRIPTION
 | 
						|
        "Classification is a way to tag different terminals on the
 | 
						|
        Power over LAN network according to their power consumption.
 | 
						|
        Devices such as IP telephones, WLAN access points and others,
 | 
						|
        will be classified according to their power requirements.
 | 
						|
 | 
						|
        The meaning of the classification labels is defined in the
 | 
						|
        IEEE specification.
 | 
						|
 | 
						|
       This variable is valid only while a PD is being powered,
 | 
						|
        that is, while the attribute pethPsePortDetectionStatus
 | 
						|
        is reporting the enumeration deliveringPower."
 | 
						|
    REFERENCE
 | 
						|
      "IEEE Std 802.3af Section 30.9.1.1.6
 | 
						|
       aPSEPowerClassification"
 | 
						|
   ::= { pethPsePortEntry 10 }
 | 
						|
 | 
						|
   pethPsePortInvalidSignatureCounter OBJECT-TYPE
 | 
						|
    SYNTAX Counter32
 | 
						|
    MAX-ACCESS read-only
 | 
						|
    STATUS current
 | 
						|
    DESCRIPTION
 | 
						|
       "This counter is incremented when the PSE state diagram
 | 
						|
         enters the state SIGNATURE_INVALID."
 | 
						|
    REFERENCE
 | 
						|
          "IEEE Std 802.3af Section 30.9.1.1.7
 | 
						|
           aPSEInvalidSignatureCounter"
 | 
						|
    ::= { pethPsePortEntry 11 }
 | 
						|
 | 
						|
   pethPsePortPowerDeniedCounter OBJECT-TYPE
 | 
						|
    SYNTAX Counter32
 | 
						|
    MAX-ACCESS read-only
 | 
						|
    STATUS current
 | 
						|
    DESCRIPTION
 | 
						|
          "This counter is incremented when the PSE state diagram
 | 
						|
             enters the state POWER_DENIED."
 | 
						|
    REFERENCE
 | 
						|
      "IEEE Std 802.3af Section 30.9.1.1.8
 | 
						|
       aPSEPowerDeniedCounter"
 | 
						|
    ::= { pethPsePortEntry 12 }
 | 
						|
 | 
						|
   pethPsePortOverLoadCounter OBJECT-TYPE
 | 
						|
    SYNTAX Counter32
 | 
						|
    MAX-ACCESS read-only
 | 
						|
    STATUS current
 | 
						|
    DESCRIPTION
 | 
						|
          "This counter is incremented when the PSE state diagram
 | 
						|
             enters the state ERROR_DELAY_OVER."
 | 
						|
    REFERENCE
 | 
						|
      "IEEE Std 802.3af Section 30.9.1.1.9
 | 
						|
       aPSEOverLoadCounter"
 | 
						|
    ::= { pethPsePortEntry 13 }
 | 
						|
 | 
						|
   pethPsePortShortCounter OBJECT-TYPE
 | 
						|
    SYNTAX Counter32
 | 
						|
    MAX-ACCESS read-only
 | 
						|
    STATUS current
 | 
						|
    DESCRIPTION
 | 
						|
          "This counter is incremented when the PSE state diagram
 | 
						|
             enters the state ERROR_DELAY_SHORT."
 | 
						|
    REFERENCE
 | 
						|
      "IEEE Std 802.3af Section 30.9.1.1.10
 | 
						|
       aPSEShortCounter"
 | 
						|
    ::= { pethPsePortEntry 14 }
 | 
						|
 | 
						|
-- Main PSE Objects
 | 
						|
 | 
						|
pethMainPseObjects       OBJECT IDENTIFIER ::= { pethObjects 3 }
 | 
						|
 | 
						|
pethMainPseTable OBJECT-TYPE
 | 
						|
       SYNTAX      SEQUENCE OF PethMainPseEntry
 | 
						|
       MAX-ACCESS  not-accessible
 | 
						|
       STATUS      current
 | 
						|
       DESCRIPTION
 | 
						|
           "A table of objects that display and control attributes
 | 
						|
            of the main power source in a PSE  device.  Ethernet
 | 
						|
            switches are one example of boxes that would support
 | 
						|
            these objects.
 | 
						|
            Values of all read-write objects in this table are
 | 
						|
            persistent at restart/reboot."
 | 
						|
       ::= { pethMainPseObjects 1 }
 | 
						|
 | 
						|
   pethMainPseEntry OBJECT-TYPE
 | 
						|
       SYNTAX      PethMainPseEntry
 | 
						|
       MAX-ACCESS  not-accessible
 | 
						|
       STATUS      current
 | 
						|
       DESCRIPTION
 | 
						|
            "A set of objects that display and control the Main
 | 
						|
             power of a PSE. "
 | 
						|
       INDEX    { pethMainPseGroupIndex }
 | 
						|
       ::= { pethMainPseTable 1 }
 | 
						|
 | 
						|
   PethMainPseEntry ::= SEQUENCE {
 | 
						|
       pethMainPseGroupIndex
 | 
						|
           Integer32,
 | 
						|
       pethMainPsePower
 | 
						|
           Gauge32 ,
 | 
						|
       pethMainPseOperStatus
 | 
						|
           INTEGER,
 | 
						|
       pethMainPseConsumptionPower
 | 
						|
           Gauge32,
 | 
						|
       pethMainPseUsageThreshold
 | 
						|
           Integer32
 | 
						|
   }
 | 
						|
     pethMainPseGroupIndex OBJECT-TYPE
 | 
						|
       SYNTAX       Integer32 (1..2147483647)
 | 
						|
       MAX-ACCESS  not-accessible
 | 
						|
       STATUS      current
 | 
						|
       DESCRIPTION
 | 
						|
           "This variable uniquely identifies the group to which
 | 
						|
           power Ethernet PSE is connected.  Group means (box in
 | 
						|
           the stack, module in a rack) and the value 1 MUST be
 | 
						|
           used for non-modular devices.  Furthermore, the same
 | 
						|
           value MUST be used in this variable, pethPsePortGroupIndex,
 | 
						|
           and pethNotificationControlGroupIndex to refer to a
 | 
						|
           given box in a stack or module in a rack."
 | 
						|
       ::= { pethMainPseEntry 1 }
 | 
						|
 | 
						|
     pethMainPsePower OBJECT-TYPE
 | 
						|
       SYNTAX      Gauge32  (1..65535)
 | 
						|
       UNITS      "Watts"
 | 
						|
       MAX-ACCESS  read-only
 | 
						|
       STATUS      current
 | 
						|
       DESCRIPTION
 | 
						|
               "The nominal power of the PSE expressed in Watts."
 | 
						|
       ::= { pethMainPseEntry 2 }
 | 
						|
 | 
						|
     pethMainPseOperStatus OBJECT-TYPE
 | 
						|
       SYNTAX INTEGER   {
 | 
						|
               on(1),
 | 
						|
               off(2),
 | 
						|
               faulty(3)
 | 
						|
          }
 | 
						|
       MAX-ACCESS  read-only
 | 
						|
       STATUS      current
 | 
						|
       DESCRIPTION
 | 
						|
               "The operational status of the main PSE."
 | 
						|
       ::= { pethMainPseEntry 3 }
 | 
						|
 | 
						|
     pethMainPseConsumptionPower OBJECT-TYPE
 | 
						|
       SYNTAX      Gauge32
 | 
						|
       UNITS      "Watts"
 | 
						|
       MAX-ACCESS  read-only
 | 
						|
       STATUS      current
 | 
						|
       DESCRIPTION
 | 
						|
               "Measured usage power expressed in Watts."
 | 
						|
       ::= { pethMainPseEntry 4 }
 | 
						|
 | 
						|
     pethMainPseUsageThreshold OBJECT-TYPE
 | 
						|
       SYNTAX      Integer32  (1..99)
 | 
						|
       UNITS      "%"
 | 
						|
       MAX-ACCESS  read-write
 | 
						|
       STATUS      current
 | 
						|
       DESCRIPTION
 | 
						|
               "The usage threshold expressed in percents for
 | 
						|
                comparing the measured power and initiating
 | 
						|
                an alarm if the threshold is exceeded."
 | 
						|
       ::= { pethMainPseEntry 5 }
 | 
						|
 | 
						|
-- Notification  Control  Objects
 | 
						|
 | 
						|
pethNotificationControl        OBJECT IDENTIFIER ::= { pethObjects 4 }
 | 
						|
 | 
						|
pethNotificationControlTable OBJECT-TYPE
 | 
						|
       SYNTAX      SEQUENCE OF PethNotificationControlEntry
 | 
						|
       MAX-ACCESS  not-accessible
 | 
						|
       STATUS      current
 | 
						|
       DESCRIPTION
 | 
						|
           "A table of objects that display and control the
 | 
						|
            Notification on a PSE  device.
 | 
						|
            Values of all read-write objects in this table are
 | 
						|
            persistent at restart/reboot."
 | 
						|
       ::= { pethNotificationControl 1 }
 | 
						|
 | 
						|
   pethNotificationControlEntry OBJECT-TYPE
 | 
						|
       SYNTAX      PethNotificationControlEntry
 | 
						|
       MAX-ACCESS  not-accessible
 | 
						|
       STATUS      current
 | 
						|
       DESCRIPTION
 | 
						|
            "A set of objects that control the Notification events."
 | 
						|
       INDEX    { pethNotificationControlGroupIndex }
 | 
						|
       ::= { pethNotificationControlTable 1 }
 | 
						|
 | 
						|
   PethNotificationControlEntry ::= SEQUENCE {
 | 
						|
       pethNotificationControlGroupIndex
 | 
						|
           Integer32,
 | 
						|
       pethNotificationControlEnable
 | 
						|
           TruthValue
 | 
						|
   }
 | 
						|
     pethNotificationControlGroupIndex OBJECT-TYPE
 | 
						|
       SYNTAX      Integer32 (1..2147483647)
 | 
						|
       MAX-ACCESS  not-accessible
 | 
						|
       STATUS      current
 | 
						|
       DESCRIPTION
 | 
						|
           "This variable uniquely identifies the group.  Group
 | 
						|
            means box in the stack, module in a rack and the value
 | 
						|
            1 MUST be used for non-modular devices.  Furthermore,
 | 
						|
            the same value MUST be used in this variable,
 | 
						|
            pethPsePortGroupIndex, and
 | 
						|
            pethMainPseGroupIndex to refer to a given box in a
 | 
						|
            stack or module in a rack. "
 | 
						|
       ::= { pethNotificationControlEntry 1 }
 | 
						|
 | 
						|
      pethNotificationControlEnable  OBJECT-TYPE
 | 
						|
       SYNTAX             TruthValue
 | 
						|
       MAX-ACCESS         read-write
 | 
						|
       STATUS             current
 | 
						|
       DESCRIPTION
 | 
						|
          "This object controls, on a per-group basis, whether
 | 
						|
             or not notifications from the agent are enabled.  The
 | 
						|
             value true(1) means that notifications are enabled; the
 | 
						|
             value false(2) means that they are not."
 | 
						|
       ::= { pethNotificationControlEntry 2 }
 | 
						|
 | 
						|
--
 | 
						|
-- Notifications Section
 | 
						|
--
 | 
						|
--
 | 
						|
 | 
						|
     pethPsePortOnOffNotification NOTIFICATION-TYPE
 | 
						|
         OBJECTS     { pethPsePortDetectionStatus }
 | 
						|
         STATUS      current
 | 
						|
         DESCRIPTION
 | 
						|
             " This Notification indicates if Pse Port is delivering or
 | 
						|
               not power to the PD.  This Notification SHOULD be sent on
 | 
						|
               every status change except in the searching mode.
 | 
						|
               At least 500 msec must elapse between notifications
 | 
						|
               being emitted by the same object instance."
 | 
						|
          ::= { pethNotifications 1 }
 | 
						|
 | 
						|
     pethMainPowerUsageOnNotification NOTIFICATION-TYPE
 | 
						|
         OBJECTS     { pethMainPseConsumptionPower  }
 | 
						|
         STATUS      current
 | 
						|
         DESCRIPTION
 | 
						|
           " This Notification indicate PSE Threshold usage
 | 
						|
               indication is on, the usage power is above the
 | 
						|
               threshold.  At least 500 msec must elapse between
 | 
						|
               notifications being emitted by the same object
 | 
						|
               instance."
 | 
						|
         ::= { pethNotifications 2 }
 | 
						|
 | 
						|
      pethMainPowerUsageOffNotification NOTIFICATION-TYPE
 | 
						|
         OBJECTS     { pethMainPseConsumptionPower }
 | 
						|
         STATUS      current
 | 
						|
         DESCRIPTION
 | 
						|
           " This Notification indicates PSE Threshold usage indication
 | 
						|
               off, the usage power is below the threshold.
 | 
						|
               At least 500 msec must elapse between notifications being
 | 
						|
               emitted by the same object instance."
 | 
						|
         ::= { pethNotifications 3 }
 | 
						|
 | 
						|
--
 | 
						|
-- Conformance Section
 | 
						|
--
 | 
						|
pethCompliances OBJECT IDENTIFIER ::= { pethConformance 1 }
 | 
						|
pethGroups      OBJECT IDENTIFIER ::= { pethConformance 2 }
 | 
						|
 | 
						|
pethCompliance MODULE-COMPLIANCE
 | 
						|
       STATUS  current
 | 
						|
       DESCRIPTION
 | 
						|
               "Describes the requirements for conformance to the
 | 
						|
               Power Ethernet MIB."
 | 
						|
 | 
						|
       MODULE  -- this module
 | 
						|
           MANDATORY-GROUPS { pethPsePortGroup,
 | 
						|
                              pethPsePortNotificationGroup,
 | 
						|
                              pethNotificationControlGroup
 | 
						|
                            }
 | 
						|
           GROUP   pethMainPseGroup
 | 
						|
           DESCRIPTION
 | 
						|
               "The pethMainPseGroup is mandatory for PSE systems
 | 
						|
                that implement a main power supply."
 | 
						|
           GROUP   pethMainPowerNotificationGroup
 | 
						|
           DESCRIPTION
 | 
						|
               "The pethMainPowerNotificationGroup is mandatory for
 | 
						|
               PSE systems that implement a main power supply."
 | 
						|
       ::= { pethCompliances 1 }
 | 
						|
 | 
						|
pethPsePortGroup OBJECT-GROUP
 | 
						|
    OBJECTS {
 | 
						|
       pethPsePortAdminEnable,
 | 
						|
       pethPsePortPowerPairsControlAbility,
 | 
						|
       pethPsePortPowerPairs,
 | 
						|
       pethPsePortDetectionStatus,
 | 
						|
       pethPsePortPowerPriority,
 | 
						|
       pethPsePortMPSAbsentCounter,
 | 
						|
       pethPsePortInvalidSignatureCounter,
 | 
						|
       pethPsePortPowerDeniedCounter,
 | 
						|
       pethPsePortOverLoadCounter,
 | 
						|
       pethPsePortShortCounter,
 | 
						|
       pethPsePortType,
 | 
						|
       pethPsePortPowerClassifications
 | 
						|
    }
 | 
						|
    STATUS  current
 | 
						|
    DESCRIPTION
 | 
						|
          "PSE Port objects."
 | 
						|
    ::= { pethGroups 1 }
 | 
						|
 | 
						|
pethMainPseGroup OBJECT-GROUP
 | 
						|
    OBJECTS {
 | 
						|
       pethMainPsePower,
 | 
						|
       pethMainPseOperStatus,
 | 
						|
       pethMainPseConsumptionPower,
 | 
						|
       pethMainPseUsageThreshold
 | 
						|
    }
 | 
						|
    STATUS  current
 | 
						|
    DESCRIPTION
 | 
						|
            "Main PSE Objects. "
 | 
						|
    ::= { pethGroups 2 }
 | 
						|
 | 
						|
pethNotificationControlGroup OBJECT-GROUP
 | 
						|
    OBJECTS {
 | 
						|
       pethNotificationControlEnable
 | 
						|
    }
 | 
						|
    STATUS  current
 | 
						|
    DESCRIPTION
 | 
						|
            "Notification Control  Objects. "
 | 
						|
    ::= { pethGroups 3 }
 | 
						|
 | 
						|
pethPsePortNotificationGroup NOTIFICATION-GROUP
 | 
						|
    NOTIFICATIONS { pethPsePortOnOffNotification}
 | 
						|
    STATUS           current
 | 
						|
    DESCRIPTION  "Pse Port Notifications."
 | 
						|
    ::= { pethGroups 4 }
 | 
						|
 | 
						|
  pethMainPowerNotificationGroup NOTIFICATION-GROUP
 | 
						|
     NOTIFICATIONS { pethMainPowerUsageOnNotification,
 | 
						|
                      pethMainPowerUsageOffNotification}
 | 
						|
    STATUS           current
 | 
						|
    DESCRIPTION  "Main PSE Notifications."
 | 
						|
      ::= { pethGroups 5 }
 | 
						|
 | 
						|